• Title/Summary/Keyword: Walking Assistive Robot

Search Result 21, Processing Time 0.022 seconds

Classification of Wearable Walking-Assistive Robots for Task-Oriented Design (작업지향 설계를 위한 의복형 보행보조 로봇의 분류방법)

  • Kim, Heon-Hui;Jung, Jin-Woo;Jang, Hyo-Young;Kim, Jin-Oh;Bien, Zeung-Nam
    • The Journal of Korea Robotics Society
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • In this paper, we propose a methodology for classifying types of lower limb disability and their mechanical structure, based on extensive survey of previous developments. We also propose a task-oriented design with human-friendly and energy-efficient assistive system. The result can be used for optimal design of wearable walking-assistive robot considering the type of disability and the content of task.

  • PDF

Comfort Evaluation by Wearing a Gait-Assistive Rehabilitation Robot (보행보조 재활 로봇 착용에 따른 쾌적성 평가)

  • Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.6
    • /
    • pp.1107-1119
    • /
    • 2020
  • This study analyzed a subject's body reaction and subjective sensation when wearing a gait-assistive rehabilitation robot. The research method measured skin and clothing surface temperatures for 'seating-standing' and 'walking in place' exercises after wearing a gait-assistive rehabilitation robot. In addition, subjective sensation and satisfaction were evaluated on a 7-point Likert scale. The study results showed that the average skin temperature during exercise while wearing the gait-assistive rehabilitation robot was within a comfortable range. However, during the 'seating-standing' exercise, the skin temperature was slightly lowered. Additionally, the clothing surface temperature tended to be lower than the pre-exercise temperature after all exercises. The subjective sensation evaluation results showed that the wear comfort of the waist part was low during mobility/activity. In addition, an overall improvement in the wear comfort of the robot is necessary. The short-time movement of wearing and walking in the gait-assistive rehabilitation robot did not interfere with the thermal comfort of the body. However, the robot needs to be ergonomically improved in consideration of the long wearing time along with improved material that to satisfy overall wearing comfort.

Development of an Intelligent Ankle Assistive Robot (지능형 발목 근력 보조 로봇의 개발)

  • Jeong, Woo-Chul;Kim, Chang-Soon;Park, Jin-Yong;Hyun, Jung-Guen;Kim, Jung-Yup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.6
    • /
    • pp.538-546
    • /
    • 2015
  • This paper describes an intelligent ankle assistive robot which provides assistive power to reduce ankle torque based on an analysis of ankle motion and muscle patterns during walking on level and sloped floors. The developed robot can assist ankle muscle power by driving an electric geared motor at the exact timing through the use of an accelerometer that detects gait phase and period, and a potentiometer to measure floor slope angle. A simple muscle assistive link mechanism is proposed to convert the motor torque into the foot assistive force. In particular, this mechanism doesn't restrain the wearer's ankle joint; hence, there is no danger of injury if the motor malfunctions. During walking, the link mechanism pushes down the top of the foot to assist the ankle torque, and it can also lift the foot by inversely driving the linkage, so this robot is useful for foot drop patients. The developed robot and control algorithm are experimentally verified through walking experiments and EMG (Electromyography) measurements.

Development of Intelligent Walking Assistive Robot Using Stereo Cameras (스테레오 카메라를 이용한 지능형 보행보조로봇의 개발)

  • Park, Min-Jong;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.837-848
    • /
    • 2014
  • This paper describes the development of a walking assistive robot for effective self-rehabilitation for elderly people facing an inconvenience in walking. The main features of the developed robot are enhanced safety and mobility using the baby walker and electric wheelchair mechanisms and an accurate walking tracking control algorithm using potentiometers and stereo cameras. Specifically, a pelvis supporter is designed to prevent the user from falling down and reduce the burden on their legs, and electric motors are used for easy locomotion with low effort. Next, the walking intention and direction of the user are automatically recognized by using potentiometers attached at the pelvis supporter so that the robot can track the user, and the rapidity and accuracy of the tracking were increased by applying a lower-body motion analysis algorithm with stereo cameras. Finally, the user-tracking performance of the developed robot was experimentally verified through stepwise walking assistance experiments.

Analysis of stair walking characteristics for the development of exoskeletal walking assist robot (외골격 보행보조로봇 개발을 위한 정상인의 계단보행특성 분석)

  • Cho, H.S.;Chang, Y.H.;Ryu, J.C.;Mun, M.S.;Kim, C.B.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.15-22
    • /
    • 2012
  • The mechanical system of wearable walking assist robot needs to be optimized for adapting with human body structure and the planned control algorithm should have a secure procedure when a incongruity situation which can cause musculoskeletal injury occurs because a wearable robot is attached to a body. The understanding of walking or musculoskeletal motions characteristics must be preceeded and analyzed for developing novel wearable walking assist robot. In this study we tried to find out the capacities of powers and torques of joint actuators to design optimized performances of system and to obtain the analysis data to figure out the characteristics of joint movements during some types of walk. The major types of walk and motion are stair climbing and descending, sit-to-stand motion, and slope walking. In this study all these motions were analyzed experimentally except slope walking.

  • PDF

Gait Assist Method by Wearable Robot for Incomplete Paraplegic Patients (하지 부분마비 장애인을 위한 착용형 로봇의 보행 보조 방법)

  • Woo, Hanseung;Lee, Jangmok;Kong, Kyoungchul
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.2
    • /
    • pp.144-151
    • /
    • 2017
  • An important characteristic of people with partially impaired walking ability, such as incomplete paraplegics, is that they are able to generate voluntary motion of lower-limbs. Therefore, wearable robots for the incomplete paraplegic patients require a different assistance method compared to those of complete paraplegics. First, the wearable robot should be controlled to not resist wearer's motion. Second, it should be able to generate assistive torque accurately when needed. In this paper, a wearable robot, called EROWA, for the incomplete paraplegic patients is introduced. EROWA utilizes compact rotary series elastic actuators (cRSEAs) and a control method called the zero impedance control to reduce the mechanical resistance. An assistive torque trajectory is proposed to assist gait in this paper. The proposed method is verified by simulation and experimental studies.

Kinematic Characteristics of Walking-Assistance Robot (보행보조 로봇의 운동학적 특성)

  • Bae, Ha-Suk;Kim, Jin-Oh;Chun, Han-Yong;Park, Kwang-Hun;Lee, Kyung-Whan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.503-515
    • /
    • 2011
  • We developed a walking-assistance robot for walking rehabilitation and assessed the kinematic characteristics of a prototype. The walking-assistance robot is composed of hip, knee, and ankle joints, and each joint is driven by a motor with a decelerator. The equations of angular displacement while walking were derived by theoretically analyzing human locomotion, and the calculated angular displacements were then applied to the robot controller. The output angular displacement of each joint was measured and compared with its input angular displacement in walking experiments on a treadmill at various walking speeds and strides. The differences between the input and output angular displacements are 5.22% for the hip and 2.97% for the knee joints, and it has been confirmed that the walking-assistance robot works well.

A Study on Control of Walking Assistance Robot for Hemiplegia Patients with EMG Signal (EMG 신호로 반신불수 환자의 보행 보조로봇 제어에 관한 연구)

  • Shin, D.S.;Lee, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.55-62
    • /
    • 2013
  • The exoskeleton robot to assist walking of hemiplegia patients or disabled persons has been studied in this paper. The exoskeleton robot with degrees of freedom of 2 axis has been developed and tested for joint motion. The obtained EMG signal from normal person was analyzed and the control signal was extracted from it for convenient and automotive performance of assistance robot to help hemiplegia patient walks as normal person does. the purpose of using FES(Functional Electrical Stimulation) for hemiplegia patient's walk is to restore damaged body function by this, but this could give fatal electrical shock to patients by wrong use or cause quick fatigue in muscle by continuous stimulation. The convenient movement of hemiplegia patients with minimum muscle fatigue was looked possibly by operation of assistance robot exoskeleton using control signal. and the walking assistance exoskeleton robot seemed works more efficiently than using FES stimulator. The experiment in this study was performed based on usual motion in our life like walking, standing-up, sitting-down, and particularly feedback control system using Piezo sensor along with button switch was applied for smooth swing motion in walking. The experiment also shows that hemiplegia patients can move conveniently by using electromyogram signal of healthy leg for the operation signal of assistance robot system attached at damaged symmetrical leg.

  • PDF

Design and Control of a Novel Tendon-driven Exoskeletal Power Assistive Device (새로운 와이어 구동방식 외골격 보조기의 설계 및 제어)

  • Kong Kyoung-chul;Jeon Doyoung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.11
    • /
    • pp.936-942
    • /
    • 2005
  • Recently the exoskeletal power assistive equipment which is a kind of wearable robot has been widely developed to help the human body motion. For the elderly people and patients, however, some limits exist due to the weight and volume of the equipments. As a feasible solution, a tendon-driven exoskeletal power assistive device fur the lower body, and caster walker are proposed in this research. Since the caster walker carries the heavy items, the weight and volume of the wearable exoskeleton are minimized. The key control is used to generate the joint torque required to assist motions such as sitting, standing and walking. Experiments were performed for several motions and the EMG sensors were used to measure the magnitude of assistance. When the motion of sitting down and standing up was compared with and without wearing the proposed device, the $25\%$ assistance was acquired.

A Study on Energy Efficiency in Walking and Stair Climbing for Elderly Wearing Complex Muscle Support System

  • Jang-hoon Shin;Hye-Kang Park;Joonyoung Jung;Dong-Woo Lee;Hyung Cheol Shin;Hwang-Jae Lee;Wan-Hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.478-487
    • /
    • 2022
  • Objective: This study was conducted to analyze the effect of wearable complex muscle support system on energy efficiency during walking in elderly. Design: Cross sectional study Methods: Twenty healthy elderly participated in this study. All subjects performed a 6 minuteswalk test(6MWT) and stair climbing test in dual, slack and no suit conditions. In each condition, oxygen consumption(VO2), metabolic equivalents(METs), energy expenditure measures(EEm), physiological cost index(PCI), walking velocity and heartrate were measured. Through repeated measured ANOVA, it was investigated whether there was a statistically significant difference in the measurement results between the three conditions. Results: In over-ground walking, VO2, METs and EEm showed significant differences between no suit and slack conditions(p<0.05). In stair climbing, VO2 showed significant difference between slack and dual conditions(p<0.05). Also, METs and EEm showed significant differences between no suit and slack, and between slack and dual conditions(p<0.05). Conclusions: Wearing the wearable complex muscle support system for elderly does not have much benefit in energy metabolism efficiency in over-ground, but there is a benefit in stair walking.