• 제목/요약/키워드: WAS

검색결과 588,723건 처리시간 0.222초

에폭시 수지 모르터의 특성에 관한 실험적 연구 (Experimental Studies on the Properties of Epoxy Resin Mortars)

  • 연규석;강신업
    • 한국농공학회지
    • /
    • 제26권1호
    • /
    • pp.52-72
    • /
    • 1984
  • This study was performed to obtain the basic data which can be applied to the use of epoxy resin mortars. The data was based on the properties of epoxy resin mortars depending upon various mixing ratios to compare those of cement mortar. The resin which was used at this experiment was Epi-Bis type epoxy resin which is extensively being used as concrete structures. In the case of epoxy resin mortar, mixing ratios of resin to fine aggregate were 1: 2, 1: 4, 1: 6, 1: 8, 1:10, 1 :12 and 1:14, but the ratio of cement to fine aggregate in cement mortar was 1 : 2.5. The results obtained are summarized as follows; 1.When the mixing ratio was 1: 6, the highest density was 2.01 g/cm$^3$, being lower than 2.13 g/cm$^3$ of that of cement mortar. 2.According to the water absorption and water permeability test, the watertightness was shown very high at the mixing ratios of 1: 2, 1: 4 and 1: 6. But then the mixing ratio was less than 1 : 6, the watertightness considerably decreased. By this result, it was regarded that optimum mixing ratio of epoxy resin mortar for watertight structures should be richer mixing ratio than 1: 6. 3.The hardening shrinkage was large as the mixing ratio became leaner, but the values were remarkably small as compared with cement mortar. And the influence of dryness and moisture was exerted little at richer mixing ratio than 1: 6, but its effect was obvious at the lean mixing ratio, 1: 8, 1:10,1:12 and 1:14. It was confirmed that the optimum mixing ratio for concrete structures which would be influenced by the repeated dryness and moisture should be rich mixing ratio higher than 1: 6. 4.The compressive, bending and splitting tensile strenghs were observed very high, even the value at the mixing ratio of 1:14 was higher than that of cement mortar. It showed that epoxy resin mortar especially was to have high strength in bending and splitting tensile strength. Also, the initial strength within 24 hours gave rise to high value. Thus it was clear that epoxy resin was rapid hardening material. The multiple regression equations of strength were computed depending on a function of mixing ratios and curing times. 5.The elastic moduli derived from the compressive stress-strain curve were slightly smaller than the value of cement mortar, and the toughness of epoxy resin mortar was larger than that of cement mortar. 6.The impact resistance was strong compared with cement mortar at all mixing ratios. Especially, bending impact strength by the square pillar specimens was higher than the impact resistance of flat specimens or cylinderic specimens. 7.The Brinell hardness was relatively larger than that of cement mortar, but it gradually decreased with the decline of mixing ratio, and Brinell hardness at mixing ratio of 1 :14 was much the same as cement mortar. 8.The abrasion rate of epoxy resin mortar at all mixing ratio, when Losangeles abation testing machine revolved 500 times, was very low. Even mixing ratio of 1 :14 was no more than 31.41%, which was less than critical abrasion rate 40% of coarse aggregate for cement concrete. Consequently, the abrasion rate of epoxy resin mortar was superior to cement mortar, and the relation between abrasion rate and Brinell hardness was highly significant as exponential curve. 9.The highest bond strength of epoxy resin mortar was 12.9 kg/cm$^2$ at the mixing ratio of 1:2. The failure of bonded flat steel specimens occurred on the part of epoxy resin mortar at the mixing ratio of 1: 2 and 1: 4, and that of bonded cement concrete specimens was fond on the part of combained concrete at the mixing ratio of 1 : 2 ,1: 4 and 1: 6. It was confirmed that the optimum mixing ratio for bonding of steel plate, and of cement concrete should be rich mixing ratio above 1 : 4 and 1 : 6 respectively. 10.The variations of color tone by heating began to take place at about 60˚C, and the ultimate change occurred at 120˚C. The compressive, bending and splitting tensile strengths increased with rising temperature up to 80˚ C, but these rapidly decreased when temperature was above 800 C. Accordingly, it was evident that the resistance temperature of epoxy resin mortar was about 80˚C which was generally considered lower than that of the other concrete materials. But it is likely that there is no problem in epoxy resin mortar when used for unnecessary materials of high temperature resistance. The multiple regression equations of strength were computed depending on a function of mixing ratios and heating temperatures. 11.The susceptibility to chemical attack of cement mortar was easily affected by inorganic and organic acid. and that of epoxy resin mortar with mixing ratio of 1: 4 was of great resistance. On the other hand, when mixing ratio was lower than 1 : 8 epoxy resin mortar had very poor resistance, especially being poor resistant to organicacid. Therefore, for the structures requiring chemical resistance optimum mixing of epoxy resin mortar should be rich mixing ratio higher than 1: 4.

  • PDF

발통점(發通點)을 이용(利用)한 두통(頭痛) 치험례(治驗例) 보고(報告) (The clinical observation of patient with Headache Treated by Trigger point acupuncture therapy)

  • 이승연;김장현
    • 대한한방소아과학회지
    • /
    • 제12권1호
    • /
    • pp.133-143
    • /
    • 1998
  • Myofascial pain syndrome is one of the pain syndrome resulted from myofascia which covered muscles and clinically characteristic feature by sensitive trigger point in skeletal muscles and referred pain reactivated by stimulating each trigger point. The origin of headache are local lesion such as head, chest, abdominal organ, systemic lesion with fever or in toxic state. the other factors are consciousness, personality, anxiety, depression, which cause muscle strain in physiological environment. The Oriental Medical therapy for headache has herb medication and acupuncture. especially acupuncture therapy has not only classical systemic acupuncture(體鍼) but also neo-acupuncture(新鍼) such as commonly using auricular acupuncture(耳鍼) and manual acupuncture (手鍼), recently trigger point acupuncture is used. The author analyzed 27 cases of patient with headache treated by trigger point acupuncture therapy in Dong-yu Oriental Medical Hospital from March 1st 1997 to February 28th 1998. The following results were obtained. 1. The sex ratio of the female was 59.26%(16 cases) and male was 40.74%(11 cases), the ratio of high school student was 62.96%(17cases) as first. 2. The headache duration ratio of 2-3 years was 37.04%(10 cases) as first, 1-2 years was 25.93%(7 cases) as second. 3. The portion ratio of whole headache was 33.33%(9 cases) as first, lateral headache was 29.63%(8 cases) as second 4. The combined symptoms ratio of anorexia was 40.74%(11 cases) as first, fatigue was 33.33%(9 cases) as second, neck stiffness and dizziness was each 25.93%(7 cases) as third. 5. The therapeutic duration ratio of below 1 week was 29.63%(8 cases) as first, 2-3 weeks was 22.22%(6 cases) as second, 1-2 weeks and 3-4 weeks was each 18.52%(5 cases) as third. 6. The ratio of family history was 11 cases(40.74%). mother with headache was 6 cases, father was 3 cases, and brothers & sisters was 2 cases. 7. The herb medication ratio of Chungsanggyuntongtang(淸上?痛湯) was 37.04%(10 cases), Kamiondamtang(加味溫膽湯) was 22.22%(6 cases), Hyangsapyunguisan(香砂平胃散) was 18.25%(5 cases) etc. 8. The remedial effect ratio of good was 25.93%(7 cases), fair was 48.15%(13 cases), not improved was 7.41%(2 cases), side effect was 3.70%(1 cases), and unknown was 14.81%(4 cases).

  • PDF

Influence on Autonomic Function Before, During, and After Transcutaneous Electrical Nerve Stimulation in Senile Patients with Chronic Low Back Pain

  • Lee Mun-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • 제14권3호
    • /
    • pp.174-202
    • /
    • 2002
  • Twenty five patients, 14 males and 11 females with an average age of 75years with chronic Low Back Pain were tested before, during, and after 10minutes transcutaneous electrical nerve stimulation. It is important to consider the effect of TENS on the autonomic function because the pain pathway and the ANS pathway are somehow correlated to each other. There is still controversy among researchers who have reported the effect of TENS on autonomic function. So the purpose of this study is to measure the effect of TENS on the ANS and to see the relation of the pain control mechanism and the change in the ANS. The results were as follows : 1) Systolic blood pressure between before and during the experiment was apt to be a little increased, but statistically there was no significant change(P>.05). 2) Systolic blood pressure between during and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 3) Systolic blood pressure between before and after 10 minutes experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 4) Diastolic blood pressure between before and during experiment was apt to be a little increased, but statistically there was no significant change(P>.05). 5) Diastolic blood pressure between during and after 10 minutes experiment was significantly decreased(P<.05). 6) Diastolic blood pressure between before and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 7) Heart rate between before and during the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 8) Heart rate between during and after 10 minutes the experiment was significantly decreased(P<.05). 9) Heart rate between before and after 10 minutes the experiment was significantly decreased(P<.05). 10) Skin temperature between before and during the experiment was significantly increased(P<.05). 11) Skin temperature between during and after 10 minutes the experiment was apt to be a little increased, but statistically there was no significant change(P>.05). 12) Skin temperature between before and after 10 minutes the experiment was significantly increased(P>.05). 13) Respiratory rate between before and during the experiment was apt to be a little increased, but statistically there was no significant change(Pgt;.05). 14) Respiratory rate between during and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(Pgt;.05). 15) Respiratory rate between before and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05).

  • PDF

OBSERVATION OF THE SWEATING IN LIPSTICK BY SCANNING ELECTION MICROSCOPY

  • Seo, Su-Youn;Lee, In-Sook;Sin, Hyeon-Jong;Choi, Kyu-Yeol;Kang, She-Hoon;Ahn, Ho-Jeong
    • 대한화장품학회지
    • /
    • 제22권2호
    • /
    • pp.182-192
    • /
    • 1996
  • In this study, the relationship between wax matrix in lipstick and sweating was investigated by observing the change of size and shape of wax matrix with sweating by Scanning Electron Microscopy (SEM). For observation by SEM, a lipstick sample was frozen in liquid nitrogen, then the oil in the lipstick was extracted out in cold isopropanol($-70^{\circ}C$) for 1-3days. After isopropanol was evaporated, the sample was sputtered with gold, and examined by SEM. When examined the sweated sample by SEM, the change of wax matrix underneath the surface from fine, uniform structure to coarse, nonuniform structure was observed, which was resulted from the caking of surrounding wax matrix. That is, the oil underneath the surface was migrated to the surface of lipstick with sweating, consequently the wax matrix at that region was rearranged into the coarse matrix. In case of flamed lipstick, sweating was delayed and the wax matrix was much coarser than that of unflamed one. Its larger wax matrix at surface region was good for including oil. The effect of molding temperature on sweating was also studied. As the molding temperature was increased, sweating was greatly reduced and the size of wax matrix was increased. It was also found that sweating was influenced with the compatinility of wax and oil. A formula consisting of wax and oil which have good compatibility has a tendency of reduced sweating and increased size of wax matrix. When pigment was added to wax and oil. It was also found that sweating was influenced with the passage of time by observing a thick membrane of wax on surface of lipstick after a month from molding. In case of some lipsticks, the size of wax matrix was altered to bigger or smaller. In conclusion, the structure of wax matrix at the surface region of lipstick was changed with the process of foaming, molding temperature, compatibility of wax and oil, addition of pigment, and the passage of time. In most cases, as the size of wax matrix was increased, sweating was reduced and delayed.

  • PDF

DEXA사에 의한 일부 남자농구선수들의 체구성에 관한 연구 -체지방량, 체구성, 비율, 체조직 구성 비율, 골광물질함량과 골밀도를 중심으로- (A Study on the Body Composition in Korean Basketball Players by Dual Energy X -ray Absorptiometry)

  • 박경래;강동원;최중명;박순영
    • 보건교육건강증진학회지
    • /
    • 제15권1호
    • /
    • pp.179-194
    • /
    • 1998
  • This study focused on the body composition of Korean Basketball Players in Dual X -ray Absorptiometry. The principal subjects of this study were 10 Basketball Players who participated in the process of Dual Energy X -ray Absorptiometry at K.H. University Hospital for 8 months from Sept. 1. 1996 to April, 30. 1997. On the basis of the these measurements, the authors calculated physical indices and total fat percent. On the results of bone densitometry, the author analyzed body fat weight, body composition according to body position, bone mineral density and discerned the difference between the fatness which was calculated indirectly and which gained from the bone densitometry. 1. General Characteristics The mean age of the subjects was 20.4$\times$1.35 year. 2. Physical. Measurement The mean physical growth and development of the subjects were superior to standard value of the average Koreans 3. Body Fat by Physical Measurement Body surface area was 2.019$\times$0.111$m^2$, body volume was 74.4$\times$7.2$\ell$, body density was 1.041$\times$0.007$\ell$/kg, and body fat percent was 24.9$\times$2.9%. 4. Body Fat by Bone Densitometry Total body fat percent was 15.17$\times$2.19% and according to body position that of upper limb was 1.62%, that of lower limb was 5.55%, that of trunk was 7.06% and that of head was 1.05%. There was significant difference between the amounts of body fat from the methods used in this study; that from physical measurements and from bone densitometry method could be said most desirable. 5. Body composition According to Body Position Trunk was highest at 46.7%, lower limb was 36.0%, upper limb was 10.6%, and head was 6.7% in order. 6. Bone Mineral Content and Bone Density In bone mineral amount by body position, that of upper limb was 466.9$\times$46.4g, that of lower limb was 1,424.1$\times$154.0g, that of trunk was 1,343.0$\times$150.3g, and total bone mineral content was 3,786.8$\times$348.4g(4.78$\times$0.13%). Bone mineral density by body position, that of upper limb was 0.758$\times$0.072g/$\textrm{cm}^2$, that of lower limb was 1,342$\times$0.095g/$\textrm{cm}^2$, that of trunk was 1,169$\textrm{cm}^2$0.082g/$\textrm{cm}^2$, that of head was 1,742$\times$0.154g/$\textrm{cm}^2$ and total bone mineral density was 1,204$\times$0.077g/$\textrm{cm}^2$.

  • PDF

대한핵의학기술학회 투고 논문 분류 (Classification of submitted KSNMT dissertation)

  • 한동찬;이혁;홍건철;안병호;최성욱
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.65-69
    • /
    • 2017
  • 1977년 첫걸음을 시작한 대한핵의학기술학회의 영상관련 학술활동은 1985년 창간호를 발간하며 비로소 학회지의 형식을 갖추게 되었다. 지금까지 학회지에 게재된 방사분과 논문을 세부분야 별로 분류하여 연구논문의 동향을 알아보고자 한다. 1985년부터 2016년 상반기까지 학회지에 수록된 논문을 제출형식 별, 검사장비 별, 검사분야 별로 분류하고 엑셀(Microsoft Office 2010)프로그램을 이용하여 데이터베이스화 하였다. 이 자료를 통해 각 연도별 학회지 게재 논문 수, 세부분야별(detail) 제출 논문 수, 그리고 시대별 핵심어(keyword) 분포 등을 분석하였다. 학회지에 게재된 논문은 방사분과 1151편, 방사분과와 임상분과 두 분과의 공통주제 28편이였다. 방사분과 연대별 게재 논문 수는 1980년대 46, 1990년대 149, 2000년대 467, 2010~2016년 상반기까지 517편이였다. 제출형식별 논문 수는 원저 571, 초록 529, 심포지움 31, 특강25, 종설 11, 흥미영상 7, 포스터 3, 증례보고 2편이였다. 이중 심포지움과 특강 56편을 제외한 논문에서 검사장비 별 논문 수는 PET 319, Planar 302, SPECT 172, 방사성의약품 113, 방호 및 안전관리 103, 골밀도 28, 기타 86편이였다. 검사분야별 논문 수는 종양학 201, 장비 179, 심혈관 및 순환계 102, 환경안전 82, 골격계 76, 신경 핵의학 66, 정도관리 61, 비뇨 생식기계 56, 내분비계 49, 소화기계 44, 치료 34, 산업안전 24, 분자영상 15, 감염 및 염증 9, 호흡기계 9, 소아 핵의학 8, 기타 108편 이였다. 시대별 가장 많이 기재된 키워드(keyword)는 1999~2005년 PET, 2006~2016년 PET/CT였다. 보다 다양한 분야의 논문제출을 권장하기 위해서 대한핵의학기술학회에 게재된 논문뿐만 아니라 다양한 형태의 자료들을 데이터베이스화 하는 과정이 필요 할 것이다. 또한 많은 회원들이 영향력지표(Impact factor)가 높은 논문을 발표 할 수 있도록 대한핵의학기술학회 홈페이지를 통한 빅 데이터 자료제공 등과 같은 학회차원의 기술적, 제도적 보완과 함께 연구자 개인의 지속적인 노력과 다 기관 간의 협력하는 노력이 필요 할 것이다.

  • PDF

임상도 작성시 정밀 영급분석기법 연구 (Analysis Methology of Detailed Stand Age Classes in Forest Type Map)

  • 김정호
    • 한국환경과학회지
    • /
    • 제17권6호
    • /
    • pp.647-655
    • /
    • 2008
  • The purpose of the study is to find the problems related to the current state of the stand age classes and the method of calculating it defined in the existing forest type map and propose the more accurate method of calculating the stand age classes. The object for the study was selected as the forest scattered around the Geesan village Paju city in Kyunggi province. For the accurate method of calculating the stand age classes, such items as, the type of actual vegetation, establishment of grid-type standard area scaled down at the level of the 5% of the actual area, the types, number, DBH and age of tree found by the plots, were investigated. It was found out actual vegetation was divided into the total 24 types and the 20 types of them belonged to the growing tree areas. As the plots, the 125 places(unit area: $400m^2$) were established the types of the trees found were distributed in the range where the minimum was 1 type, the maximum was 9, the mean was $4.4{\pm}1.5$, and the mode was 4 types. The number of the trees found was distributed in the range where the minimum was 17, the maximum was 125, the mean was $4.4{\pm}1.5$, and the mode was 70. In the DBH, the minimum was 6 cm, the maximum was 30 cm, the mean was 13 cm and the mode was 10 cm. As the result of measuring the age of the 5 trees corresponding to the value of the mode in DBH, selected among the dominant species by the plots, less than 20 years was 17 places, the 115 places were included in the range from 21 to 30 years, and more than 31 years was the 6 places.

과산화수소를 이용한 몰리브덴(Mo) 용해 반응과 이에대한 청정기술 개발에 관한 연구 (A clean technology development and the molybdenum dissolution reaction with hydrogen peroxide)

  • 김재우;강수정;김남기
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.1-8
    • /
    • 2003
  • The advantages of hydrogen peroxide dissolution method were no discharge of noxious matter when dissolution of molybdenum wire which used as the center supporter, reactions occur in room temperature. The results were as follows : 1. In the FL/10-A type: Dissolution-reaction Time was 50Min., C.R.(Coil resistance) was $9.27{\Omega}(St.{\;}:{\;}9.2{\pm}0.22{\Omega})$, P.W.(Piece weight) was $10.59mg(St.{\;}:{\;}10.5{\pm}0.26mg)$. In the FL/15-D type: Dissolution-reaction Time was 55Min., C.R. was $6.39{\Omega}(St.{\;}:{\;}6.38{\pm}0.02{\Omega})$, P.W. was $16.7mg(St.{\;}:{\;}16.5{\pm}0.3mg)$. In the FL/20-H type: Dissolution-reaction Time was 45Min., C.R. was $4.7{\Omega}(St.{\;}:{\;}4.6{\pm}0.3{\Omega})$, P.W. was $20.8mg(St.{\;}:{\;}20{\pm}1.5mg)$. In the FL/20-C type: Dissolution-reaction Time was 60Min., C.R. was $4.5{\Omega}(St.{\;}:{\;}4.6{\pm}0.3{\Omega})$, P.W. was $19.8mg(St.{\;}:{\;}19{\pm}1.0mg)$. 2. In the GLS-230/40-B type: Dissolutiona-reaction Time was 45Min., C.R. was $105.1{\Omega}(St.{\;}:{\;}104{\pm}2.6{\Omega})$, P.W was $6.37mg(St.{\;}:{\;}6.3{\pm}0.16mg)$. In the GLS-230/60-F type: Dissolution- reaction Time was 45Min., C.R. was $65.92{\Omega}(St.{\;}:{\;}65{\pm}1.62{\Omega})$, P.W. was $11.91mg(St.{\;}:{\;}11.8{\pm}0.29mg)$.

성인의 우울경향 및 스트레스와 식생활 태도와의 관계 (A Survey on the Relation between Depressive Trends, Stress and Attitudes of Food Intake in Adults)

  • 김경희
    • 한국식생활문화학회지
    • /
    • 제13권4호
    • /
    • pp.327-337
    • /
    • 1998
  • A Survey was carried out to investigate relation between depressive trends, stress and attitudes of food intake in adults. In the assessing of Body Mass Index (BMI), the normal weight was 80.1%, overweight was 19.1%, obese was 0.7% in men, but normal weight was 90.3%, overweight was 9.4%, obese was 0.3% in women (p<0.001). It was represented increasing trends of obesity by the increasing of ages. Women thought their health condition was worse than men (p<0.001) 15.1% of all women tried to weight control. In changes of food intake by stress, 37.8% was increased to eat, 33.7% was reduced in women. It seems that women was significantly influenced by stress than men (p<0.01). In changes of food intake by stress in ages, 39.7% was increased of 20 years but over the 30 years was decreased or no changes of food intake (p<0.0001). All subjects wanted hot and sweet taste when stress-induced eating. 56.1% of men preferred to alcohol and beverages but 33.5% of women preferred to chocolate, cookies and breads of carbohydrate foods at the stressful conditions. But stress-induced eating dose not seems to be helpful for coping with stress in adults. In the distribution of depressive trends, the level of depression was higher in women (50.7%), whereas 34.3% in men (p<0.001). The most of 3li subjects represented attitudes of food intake below 60 scores that was needed improve and counseling of professional nutritionist. It was represented inferior to attitudes of food intake by the increasing of depressive trends and stress in women. It was higher level of overweight and obese in the below 60 scores of attitudes of food intake and higher depressive groups.

  • PDF

비만도와 실루엣(Silhouette) 분류에 따른 20대 여성의 체형 연구 (A Study on the Somatotype of Women in Their Twenties by Degree of Obesity and Classification of Silhouette)

  • 김진아;이정란
    • 한국지역사회생활과학회지
    • /
    • 제19권3호
    • /
    • pp.419-429
    • /
    • 2008
  • This study was conducted to analyze the characteristics of women's body somatotypes by direct measurements. Through the classification of degree of obesity and silhouette, women in their 20s who have a great interest in body somatotype can grasp their real somatotype and recognize their obesity rate and silhouette easily. The results are as follows: 1. Average sizes of subjects for this study were: height 160.3cm, weight 52.2kg, bust 83.7cm, waist 65.7cm, hips 91.1cm. And average values of each body mass index were: BMI 20.3, Rohrer Index 1.27, Vervaeck Index 84.8. 2. For the BMI value, the Average Numeric Index of normal somatotype was the highest, 76.9%. The Rohrer Index of underweight somatotype was 34.3% and the Average Numeric Index was 1.12. In the Vervaeck Index, underweight somatotype was 35.7%, and the average Numeric Index was 79.1, while the overweight somatotype was 7.4% of the Vervaeck Index and 100.8 of the Average Numeric Index. So the index which had the largest range of normal values from the same subjects, was the BMI, then the Rohrer Index, and finally, the Vervaeck Index in that order. 3. In the result of sorting bodies with silhouettes, when drop value were used to sort, N type (normal somatotype) was 69.4%, H type (one has similar sizes in waist size and hips) was 20.4% and A type (one has big hips) was 10.2% in that order. Among people in their early 20s, A type was 12.1%. H type was high, 22.8%, among women in their late 20s. When Sinozaki's method of classifying body types was used, ideal somatotype was 86.6%, A type was 7.4%, I type was 5.6% and X type was 0.5%. Women in their late 20s showed higher rates of ideal somatotype, the rates of A type and I type were lower than women in their early 20s.

  • PDF