• Title/Summary/Keyword: W/C ratio

Search Result 1,772, Processing Time 0.028 seconds

Interfacial Microstructure of Diffusion-Bonded W-25Re/Ti/Graphite Joint and Its High-Temperature Stability (확산 접합에 의해 제조된 텅스텐-레늄 합금/티타늄/그래파이트 접합체의 미세구조 및 고온 안정성)

  • Kim, Joo-Hyung;Baek, Chang Yeon;Kim, Dong Seok;Lim, Seong Taek;Kim, Do Kyung
    • Korean Journal of Materials Research
    • /
    • v.26 no.12
    • /
    • pp.751-756
    • /
    • 2016
  • Graphite was diffusion-bonded by hot-pressing to W-25Re alloy using a Ti interlayer. For the joining, a uniaxial pressure of 25 MPa was applied at $1600^{\circ}C$ for 2 hrs in an argon atmosphere with a heating rate of $10^{\circ}C\;min^{-1}$. The interfacial microstructure and elemental distribution of the W-25Re/Ti/Graphite joints were analyzed by scanning electron microscopy (SEM). Hot-pressed joints appeared to form a stable interlayer without any micro-cracking, pores, or defects. To investigate the high-temperature stability of the W-25Re/Ti/Graphite joint, an oxy-acetylene torch test was conducted for 30 seconds with oxygen and acetylene at a 1.3:1 ratio. Cross-sectional analysis of the joint was performed to compare the thickness of the oxide layer and its chemical composition. The thickness of W-25Re changed from 250 to $20{\mu}m$. In the elemental analysis, a high fraction of rhenium was detected at the surface oxidation layer of W-25Re, while the W-25Re matrix was found to maintain the initial weight ratio. Tungsten was first reacted with oxygen at a torch temperature over $2500^{\circ}C$ to form a tungsten oxide layer on the surface of W-25Re. Then, the remaining rhenium was subsequently reacted with oxygen to form rhenium oxide. The interfacial microstructure of the Ti-containing interlayer was stable after the torch test at a temperature over $2500^{\circ}C$.

Fluidization characteristics of Non-sirtered cement mortar using blast furnace slag and fly ash (고로슬래그와 플라이애시를 이용한 비소성 시멘트 모르타르의 유동화 특성)

  • Byun, Hui-Jae;Na, Hyeong-Won;Hyung, Won-Gil
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.186-187
    • /
    • 2022
  • The purpose of this study was to give fluidizing properties to non-sirtered cement made using by-products that can replace Portland cement by using a fluidizing agent. Blast furnace slag, C-type fly ash, and F-type fly ash were used for non-sirtered cement, and sand was used for aggregate. The amount of fluidizing agent used was fixed at 1%, and the water-cement ratio (W/C) was different by setting the binder blending ratio of the non-sintered cement differently, and the fluidity test and flow were compared. As a result of the experiment, when the flow standard was 170mm when the fluidizing agent was used, the fluidizing properties were shown at an average water-cement ratio (W/C) of 36%. Through this study, it was confirmed that the fluidizing properties appeared when the fluidizing agent was used in non-sintered cement.

  • PDF

An Analysis on the RFI of Non-GSO/MSS System into M/W Radio Stations (M / W 무선국에 미치는 비정지궤도 이동위성 시스템의 전파간섭 분석)

  • 이성수;이형수;강영흥
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.5
    • /
    • pp.504-515
    • /
    • 1997
  • In this paper, interference of non-GSO/MSS system into M/W radio stations has been analyzed as two aspects. One is that PDF(Power Flux Density) levels, which are received by M/W radio stations from non-GSO satellites, were simulated and compared with the threshold level specified in ITU-R SF.357. The other is that C/I values, which have been utilized in estimating interference between conventional fixed services, were simulated and analyzed by means of calculating excess time percent and duration below the C/I protection ratio. As the results, it was shown that interference levels received by M/W stations from non- GSO/MSS satellites don't exceed above the threshold level at all, even if changing parameters related with M/W stations. In addition, the excess percent time below the interference protection ratio is a long term of 32% in the case of Iridium interfering into a M/W stations route, but only a short term of 1.71% in the case of Globalstar interfering into a M/W stations route.

  • PDF

Studies on the Durability of Mortars (모르타르의 내구성에 관한 연구)

  • 고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.1
    • /
    • pp.1604-1615
    • /
    • 1969
  • This experiment was carried out as one of the basic studies to improve the acid resistance of concrete and it was conducted to investigate some relations among physical properties such as basorption, ratio of water to cement, compressive strength, density and ratio of mix to weight losses of mortar when exposed to 0.1 N solution of hydrochrolic acid. The results obtained from the limited data secured so far in this experiment are summarized as follows: 1. The specimens used in the experiment were made of 5 cubic centimeters of mortar having such various ratios of mix by weight as 1 : 1, 1 : 3, 1 : 5, 1 : 7, 1 : 10. 2. Physical tests included compressive strengths at 7 days, 28 days, 3 months, and 6 month, and 5 hour boiling absorption test. 3. In acid test, every specimen was immersed into 0.1 N solution of hydrochrolic acid. The specimens exposed to the acid solution were weighed to determine the weight losses of the acid-corroded at one week interval for 7 weeks exposure, and the old acid solutions were also changed to fresh one when weighed the weight losses by acid attack at one week interval. 4. The correlative relations were found among physical properties and they are expressed by certain formulas as follows; i) Relation between ratio of mix and absorption Y = 1.036x + 13.53 where Y: absorption(%) X: ratio of mix ii) Relation between ratio of mix and ratio of water-cement Y = 0.204x + 0.214 where Y: ratio of water-cement. X: ratio of mix iii) Relation between ratio of water-cement and absorption Y = 5.01x + 12.53 where Y: absorption(%). X: ratio of water-cement iv) Relation between density and absorption Y = 50.6 - 0.0176X where Y: absorption(%). X: density($kg/m^3$) v) Relation between density and ratio of water cement Y = 7.2183 - 0.0033X where Y: ratio of water-cement . X: density($kg/m^3$) 5. After completing the acid exposure test the specimens were corroded and , the per cent ranges of weight losses varies from a minimum of 20.4 per cent at a 1 : 1 mix to a maximum of 92.0 per cent at a 1:10 mix 6. The correlative relations of physical properties of mortar to weight losses by acid attak were found and they are also expressed by certain formulas as follows: i) Relation between weight losses and ratio of mix Y = 8.59X + 8.63 where Y: weight losses(%), X: ratio of mix ii) Relation between wieght losses and absorption Y = 0.121x + 12.43 where Y: absorption(%). X: weight losses(%) iii) Relation between weight losses and ratio of w/c Y = 0.0226X + 0.07 where Y: ratio of w/c X: weight losses(%) iv) Relation between weight losses and compressive strength LogY = 3.6097 - 0.05058X + 0.00022$X^2$ where Y: compressive strength ($kg/cm^3$) X: weight losses(%) v) Relation between weight losses and density Y = 2153.1 - 6.62X where Y: density($kg/m^3$) X: weigh losses(%) 7. In order to make better acid resistant mortar, it could be concluded that a 1 : 3 mix or richer mixes, adequate mixing water to minnimize the ratio of water-cement considering the workability, 16 per cent or less absorption by 5 hour boiling water, 1,800 kilogram per cubic meter or denser density by absolute weight base and 200 kilogram per square meter or compressive strength at 20 day, etc are required so as to obtain acid-resistant mortar. In addition to the above, it might be recommonded to select the fine aggregate and to use better equipments such as a mechanical vibrator, a mechanical mixer etc. in concrete manufacturing works.

  • PDF

Strength Properies of Concrete Using Waste Slag Aggregates as the Products of Steel Industry (산업폐기물인 제강 슬래그쇄석을 이용한 콘크리트의 강도특성)

  • Lee, Bong-Hak;Kim, Tae-Kyung
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.45-50
    • /
    • 1996
  • An experimental study os performed to examine the feasibility of using wastes steel furnace slag construction materials and its utility as a replacement for the natural resources to prevent the economic loss was investigated. A half factorial exprements was performed with the variables of W/C ratio, S/A, Coarse aggrigate/Slag ratio and slump as a preliminary study for optimum mix design of concrete. The results show that the W/C ratio and Slump ratio are the most important factor to the concrete strength. The substitute of waste Slag up to 100% has little influence, saying that it can substitute the coarse aggregate without damaging the concrete properties.

  • PDF

Optimizing the mix design of pervious concrete based on properties and unit cost

  • Taheri, Bahram M.;Ramezanianpour, Amir M.
    • Advances in concrete construction
    • /
    • v.11 no.4
    • /
    • pp.285-298
    • /
    • 2021
  • This study focused on experimental evaluation of mechanical properties of pervious concrete mixtures with the aim of achieving higher values of strength while considering the associated costs. The effectiveness of key parameters, including cement content, water to cement ratio (W/C), aggregate to cement ratio (A/C), and sand replacement was statistically analyzed using paired-samples t-test, Taguchi method and one-way ANOVA. Taguchi analysis determined that in general, the role of W/C was more significant in increasing strength, both compressive and flexural, than cement content and A/C. It was found that increase in replacing percent of coarse aggregate with sand could undermine specimens to percolate water, though one-way ANOVA analysis determined statistically significant increases in values of strength of mixtures. Cost analysis revealed that higher strengths did not necessarily correspond to higher costs; in addition, increasing the cement content was not an appropriate scenario to optimize both strength and cost. In order to obtain the optimal values, response surface method (RSM) was carried out. RSM optimization helped to find out that W/C of 0.40, A/C of 4.0, cement content of about 330 kg/m3 and replacing about 12% of coarse aggregate with sand could result in the best values for strength and cost while maintaining adequate permeability.

Could a Manipulation of Dietary Nutrient Contents Including Phosphorous Affect Compensatory Growth of Juvenile Olive Flounder Paralichthys olivaceus?

  • Cho, Sung Hwoan
    • Fisheries and Aquatic Sciences
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2013
  • I hypothesized that the manipulation of dietary nutrient contents including phosphorous could affect compensatory growth of juvenile olive flounder, Paralichthys olivaceus. Thirty fish averaging 34.8 g per tank were randomly chosen and distributed into 15 flow-through 180-L tanks. Three experimental diets were prepared: the control (C) diet, high protein and lipid (HPL) diet, and HPL diet with supplementation of calcium phosphate-monobasic (HPLP). Five treatments were prepared in triplicate: fish were hand-fed daily with the C diet twice a day for 8 weeks (C-8W); fish were starved for 1 week, and then fed with the HPL or HPLP diets twice a day for 7 weeks, and referred to as HPL-7W and HPLP-7W, respectively; and fish were starved for 2 weeks, and then fed with the HPL or HPLP diets twice a day for 6 weeks, and referred to as HPL-6W and HPLP-6W, respectively. The body weight of fish with C-8W, HPL-7W and HPLP-7W treatments was higher than fish with HPL-6W and HPLP-6W treatments on week 2, 4 and 6 after an initiation of the trial. At the end of the 8-week trial, fish with HPLP-7W and HPL-7W treatments overcompensated, as compared to fish with C-8W treatment. Full compensation was not achieved in fish subjected to the 2-week feed deprivation (HPL-6W and HPLP-6W treatments). Overall feed intake by fish was proportional to weeks of feeding. Feed conversion ratio of fish with HPLP-7W, HPL-6W and HPLP-6W treatments was higher than fish with C-8W treatment. The study showed that dietary supplementation of protein and lipid resulted in overcompensation of juvenile olive flounder subjected to a 1-week feed deprivation, but not a 2-week feed deprivation. Additionally, dietary supplementation of phosphorous did not further improve compensatory growth of fish.

Factors affecting waterproof efficiency of grouting in single rock fracture

  • Lee, Hang Bok;Oh, Tae-Min;Park, Eui-Seob;Lee, Jong-Won;Kim, Hyung-Mok
    • Geomechanics and Engineering
    • /
    • v.12 no.5
    • /
    • pp.771-783
    • /
    • 2017
  • Using a transparent fracture replica with aperture size and water-cement ratio (w/c), the factors affecting the penetration behavior of rock grouting were investigated through laboratory experiments. In addition, the waterproof efficiency was estimated by the reduction of water outflow through the fractures after the grout curing process. Penetration behavior shows that grout penetration patterns present similarly radial forms in all experimental cases; however, velocity of grout penetration showed clear differences according to the aperture sizes and water-cement ratio. It can be seen that the waterproof efficiency increased as the aperture size and w/c decreased. During grout injection or curing processes, air bubbles formed and bleeding occurred, both of which affected the waterproof ability of the grouting. These two phenomena can significantly prevent the successful performance of rock grouting in field-scale underground spaces, especially at deep depth conditions. Our research can provide a foundation for improving and optimizing the innovative techniques of rock grouting.

Fundamental Study of Mix Proportions of High-Flow Cement-Based Mortar for Gravel-Fill Used in Restoration of Collapsed Roads (도로유실 복구를 위한 골재 충전 고흐름도 모르타르의 기초 배합 연구)

  • Cho, Hyun Myung;Jeon, Sang Pyo;Kim, Seung Won;Yun, Kyong Ku;Park, Cheol Woo
    • International Journal of Highway Engineering
    • /
    • v.17 no.2
    • /
    • pp.63-70
    • /
    • 2015
  • PURPOSES: As a part of our research into repair techniques for roads that have collapsed as a result of a natural disaster, this study set out to find the optimum mix proportion for gravels to be used to restore a damaged area. METHODS: This study considered flow and strength-development characteristics. The experimental variables were the W/C ratio, the usage of the admixture, the types of cement, and the quantity of fine aggregate over three different experimental stages. The compressive strength was measured at 12 hours, one day, three days, and seven days. RESULTS : The flow varied with the amount of fine aggregate and the use of a high-range water-reducing (HRWR) admixture. The compressive strength also varied with respect to the type of cement and the W/C ratios. The strength satisfied the expected requirement of 21 MPa after one day, provided the mix proportion was appropriate. CONCLUSIONS: A gravel-filling high-flow cement-based mortar exhibited strength and consistency with a W/C ratio in the range of 0.40 to 0.45, assuming the use of HRWR at 0.5 to 0.7% and a fine aggregate/cement ratio of 1.0 to 1.5.