• 제목/요약/키워드: Vortex center

검색결과 306건 처리시간 0.021초

폰탄 수술에서 문합방법에 따른 혈류 변화 (Blood Flow Changes by Anastomotic Method in Fontan Operation)

  • 김상현;박영환;조범구;김종훈;홍유선;김영호;김승수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.203-206
    • /
    • 1996
  • To understand the local fluid dynamics for different desists of Fontan operation, five models were made out of Pyrex glass to facilitate in-vitro study. Model I, II and III have same position of the center of the anastomosis of the IVC( inferior vena cava) with that of the SVC(superior vena cava), but Model IV and V have 10 mm offset between them. Also the anastomotic junction angles are different(Model I and $IV:90^{\circ}$, Model II and $V:70^{\circ}$, Model $III:45^{\circ}$). These models were then connected to a flow loop for flow visualization study. In Model I any dominant vortex was not seen in the central region of the juntion, but a large unstable vortex was created in the Model II and III. In Model IV and V a significant stagnation region was created in the middle of the offset region. It also showed that the flow direction from the IVC and SVC to the LPA(left pulmonary artery) and RPA(right pulmonary artery) highly depends on the offset of the junction rather than the anastomotic junction angle.

  • PDF

Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan Operating at Different Loading Conditions

  • Baek, Je-Hyun;Lee, Gong-Hee;Myung, Hwan-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권1호
    • /
    • pp.50-60
    • /
    • 2004
  • An experimental analysis using three-dimensional Laser Doppler Velocimetry(LDV) measurement and computational analysis using the Reynolds stress model in FLUENT are conducted to give a clear understanding of the effect of blade loading on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition ($\Phi$=0.25) and two off-design conditions ($\Phi$=0.21 and 0.30). As the blade loading increases, the onset position of the rolling-up of tip leakage flow moves upstream and the trajectory of tip leakage vortex center is more inclined toward the circumferential direction. Because the casing boundary layer becomes thicker and the mixing between the through-flow and the leakage jet with the different flow direction is enforced, the streamwise vorticity decays more fast with the blade loading increasing. A distinct tip leakage vortex is observed downstream of the blade trailing edge at $\Phi$=0.30, but it is not observed at $\Phi$=0.21 and 0.25.

PLIF and PIV Measurements of Jet Flames with Acoustically Forced Coaxial Air Jets

  • Han Jeong Jae;Kim Munki;Yun Sang Wook;Yoon Youngbin
    • 한국가시화정보학회지
    • /
    • 제3권2호
    • /
    • pp.51-56
    • /
    • 2005
  • Acoustic excitations were imposed to coaxial air jet of non-premixed jet flame with hydrogen gaseous injected axially in the center of the flow. The frequencies of excitation were three dominant resonant frequencies at 1L, 2L, 3L. modes including specially 514 Hz (2L-mode) which was estimated theoretically as longitudinal mode of combustor characteristics. The mixing enhancement by acoustic forcing has been investigated quantitatively using PLIF and PIV. The effect of acoustic excitation on combustion process was significant to enhance mixing rate that coincides with specific resonant frequencies. And the behavior of vortex-interaction on flame structure was a good evidence to investigate the phenomenon of shear/mixing layer of fuel-air jet structure. The results obtained in this study concludes that generated streamwise vortex by acoustic excitation has a potential to enhance the mixing rate and abating NOx emissions.

  • PDF

블레이드 하중이 축류형 팬에서의 팁 누설 유동구조에 미치는 영향 (Effect of Blade Loading on the Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan)

  • 이공희;명환주;백제현
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.294-304
    • /
    • 2003
  • An experimental analysis using three-dimensional laser Doppler velocimetry(LDV) measurement and computational analysis using the Reynolds stress model in FLUENT are conducted to give a clear understanding of the effect of blade loading on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition ($\Phi$=0.25) and two off-design conditions ($\Phi$=0.21 and 0.30). As the blade loading increases, the onset position of the rolling-up of tip leakage flow moves upstream and the trajectory of tip leakage vortex center is more inclined toward the circumferential direction. Because the casing boundary layer becomes thicker and the mixing between the through-flow and the leakage jet with the different flow direction is enforced, the streamwise vorticity decays more fast with the blade loading increasing. A distinct tip leakage vortex is observed downstream of the blade trailing edge at $\Phi$=0.30, but it is not observed at $\Phi$=0.21 and 0.25.

Topographic effects on tornado-like vortex

  • Nasir, Zoheb;Bitsuamlak, Girma T.
    • Wind and Structures
    • /
    • 제27권2호
    • /
    • pp.123-136
    • /
    • 2018
  • The effects of steep and shallow hills on a stationary tornado-like vortex with a swirl ratio of 0.4 are simulated and quantified as Fractional Speed Up Ratios (FSUR) at three different locations of the vortex with respect to the crests of the hills. Steady state Reynolds Averaged Naiver Stokes (RANS) equations closed using Reynolds Stress Turbulence model are used to simulate stationary tornadoes. The tornado wind field obtained from the numerical simulations is first validated with previous experimental and numerical studies by comparing radial and tangential velocities, and ground static pressure. A modified fractional speed-up ratio (FSUR) evaluation technique, appropriate to the complexity of the tornadic flow, is then developed. The effects of the hill on the radial, tangential and vertical flow components are assessed. It is observed that the effect of the hill on the radial and vertical component of the flow is more pronounced, compared to the tangential component. Besides, the presence of the hill is also seen to relocate the center of tornadic flow. New FSUR values are produced for shallow and steep hills.

유한요소 LES법에 의한 축류 회전차 팁 틈새의 유동해석 (Flow Analysis in the Tip Clearance of Axial Flow Rotor Using Finite-Element Large-Eddy Simulation Method)

  • 이명호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.686-695
    • /
    • 2009
  • Flow characteristics in linear axial cascade have been studied using large eddy simulation(LES) based on finite element method(FEM) to investigate details of the leakage flow in the tip clearance of axial flow rotor. STAR-CD(FVM) and PAT-Flow(FEM) have been adopted to solve the Navier-Stokes equations for the simulation of the unsteady turbulent flow. Numerical results from the present study have been compared with the existing experimental results to investigate a tip clearance effect on velocity profile and static pressure distribution on blade surface at various spanwise positions. Both simulation results agree well with the experimental data. However, it has been shown that the results of finite-element large-eddy simulation agree better with experimental data than $k-{\varepsilon}$ turbulent model based on finite volume method regarding the tip vortex geometry and static pressure distribution at the center of the tip vortex core. As a result of this study, it is shown that finite-element large-eddy simulation method can predict more exactly on the tip leakage vortex flow and behind flow field.

분무각이 다른 GDI인젝터에 대한 증발특성 (Vaporizing Characteristics of Spray from Two Different GDI Injectors)

  • 최동석;김덕줄
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.688-696
    • /
    • 2001
  • Vaporizing characteristics of two GDI injectors with different spray angles were investigated using exciplex fluorescence method. Injector I has narrower spray angle, while injector II has wider one. The exciplex system of fluorobenzene and DEMA in a non-fluorescing base fuel of hexane was employed. In quantifying concentration of fuel vapor, quenching of concentration and temperature was corrected. Droplet size and velocity were also measured by PDPA under non-vaporizing condition. From obtaining the images of liquid and vapor phases, vaporizing GDI sprays could be divided as two regions: cone and mixing regions. For injector I, vortex region was not developed. High concentration of fuel vapor due to vaporization of many fine droplets was distributed near the spray axis. For injector II, droplets with the diameter of about 10 $\mu$m were distributed in the vortex region. The vortex region had high concentration of fuel vapor due to vaporization of these droplets. Particularly, higher and lower concentrations of fuel vapor were balanced at 2ms after the start of injection for injector II.

레이놀즈 수가 와류 감쇠 및 저항 저감형 나선형 해양 구조물 주위 유동에 미치는 영향 (Reynolds number effects on flow over twisted offshore structure with drag reduction and vortex suppression)

  • 정재환;윤현식
    • 한국해양공학회지
    • /
    • 제29권1호
    • /
    • pp.9-15
    • /
    • 2015
  • We investigated the Reynolds number effects on the flow over a twisted offshore structure in the range of 3×103≤ Re ≤ 1 × 104. To analyze the effect of the twisted surface treatment, a large eddy simulation (LES) with a dynamic subgrid model was employed. A simulation of the cylindrical structure was also carried out to compare the results with those of the twisted offshore structure. As Re increased, the mean drag and lift coefficient of the twisted offshore structure increased with the same tendency as those of the cylindrical structure. However, the increases in the mean drag and lift coefficient of the twisted offshore structure were much smaller than those of the cylindrical structure. Furthermore, elongated shear layer and suppressed vortex shedding from the twisted offshore structure occurred compared to those of the cylindrical cylinder, resulting in a drag reduction and suppression of the vortex-induced vibration (VIV). In particular, the twisted offshore structure achieved a significant reduction of over 96% in VIV compared with that of the cylindrical structure, regardless of increasing Re. As a result, we concluded that the twisted offshore structure effectively controlled the flow structures with reductions in the drag and VIV compared with the cylindrical structure, irrespective of increasing Re.