• Title/Summary/Keyword: Volumetric measurement

Search Result 240, Processing Time 0.031 seconds

A Study on the Measurement Uncertainty of Pipe Prover (파이프 프루버의 측정불확도에 관한 연구)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

Basic Study on Monitoring System of Reservoir and Leeve Using Wireless Sensor Network (무선센서 네트워크 계측을 이용한 저수지 및 제방 계측시스템 구축에 관한 기초연구)

  • Yoo, Chanho;Kim, IkHoon;Lee, Seungjoo;Hwang, Jungsoon;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.1
    • /
    • pp.25-30
    • /
    • 2018
  • Conventional monitoring method is used for evaluation of the reservoir and levee at the highest height sections. In recent years, automated measurement technology has been developed, and the measurement results are transmitted, collected and stored in real time into management office. Despite the development of real time monitoring technology, the measurement results are not used directly or indirectly with facility management at real time. Recently, as wireless sensor network measurement technology has been developed based on internet of things, this study proposed a real - time measurement and evaluation system based on wireless sensor network technology in the reservoir structure. As a result of the seepage analysis for the application, it was confirmed that the volumetric water content changes together with the change of the seepage line inside the embankment body according to the change of the water level of the embankment. In other words, the applicability of the measurement system with the volumetric water ratio set as the sensor node was verified.

A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION (복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고-)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

A Study on the Flow Characteristics and Pressure Loss of a Muffler for the Variation of Volumetric Rate and Offset (체적비와 오프셋 변화에 의한 소음기내의 유동특성과 압력손실에 관한 연구)

  • 김민호;정우인;천인범
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.93-99
    • /
    • 2000
  • It is well known that an automotive muffle strongly influences engine efficiency and noise reduction. The performance of a muffler system is determined by the geometrical parameters such as the relative location of an inlet and outlet pipe size and cross sectional geometry of a chamber. In this study numerical analysis was performed to examine the flow characteristics in the simple automotive muffler for the variation of volumetric rate and offset. The computational grid generation was carried out. The RNG k-$\varepsilon$ turbulence model was applied. To provide the boundary condition for numerical analysis the experimental measurement wes carried out. As a result of this study we could understand that there was a recirculation flow inside muffler and pressure loss depends on the variation of volumetric rate and offset.

  • PDF

Error Identification and Compensation for NC Machine Tools Using the Reference Artifact (기준물을 이용한 NC 공작기계의 오차규명 및 보상제어)

  • 정성종
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.2
    • /
    • pp.102-111
    • /
    • 2000
  • Methodology of volumetric error identification and compensation is presented to improve the accuracy of NC machine tools by using a reference artifact and a touch trigger probe. Homogeneous transformation matrix and kinematic chain are used for modeling the geo-metric and thermal errors of a three-axis vertical machining center. The reference artifact is designed and fabricated to identify the model parameters by machine tool metrology. Parameters in the error model are able to be identified and updated by direct measurement of the reference artifact on the machine tool under the actual conditions which include the thermal interactions of error sources. A volumetric error compensation system based on IBM/PC is linked with a FANUC CNC controller to compensate for the identified volumetric error in machining workspace.

  • PDF

Volumetric Error Identification for NC Machine Tools Using the Reference Artifact (기준물을 이용한 NC 공작기계의 체적오차 규명)

  • Kim, Gyeong-Don;Jeong, Seong-Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.12
    • /
    • pp.2899-2908
    • /
    • 2000
  • Methodology of volumetric error identification is presented to improve the accuracy of NC machine tools by using a reference artifact and a touch trigger probe. Homogeneous transformation matrix and kinematic chain are used for modeling the geometric and thermal errors of a three-axis vertical machining center. The reference artifact is designed and fabricated to identify the model parameters by machine tool metrology. Parameters in the error model are able to be identified and updated by direct measurement of the reference artifact on the machine tool under the actual conditions which include the thermal interactions of error sources. The proposed method can speed up and simplify volumetric error identification processes.

The performance improvement of the volumetric interferometer with multi-CCDs (다중 CCD를 이용한 부피 간섭계의 성능 개선)

  • 주지영;이혁교;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.268-271
    • /
    • 2003
  • The Volumetric Interferometer using two spherical wavefronts emitted from the ends of two single mode fibers has been suggested to measure 3-dimensional absolute coordinates. In this paper, we try to improve the performance of the volumetric interferometer using multi-CCDs. We get coordinates matching matrixes between CCDs and can obtain more information in the space with multi-CCDs. Also we find out the best arrangement of multi-CCDs by computer simulations. In the simulation we can know that it will be better to increase the distance between CCDs to improve performance. For the performance test, we do a repeatability test, a comparison test with 2-D stage and the self-calibration using artifact.

  • PDF

Error analysis and Performance test of the Volumetric interferometer for Absolute distance measurement (삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가)

  • Rhee, H.G.;Chu, J.Y.;Kim, S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.387-390
    • /
    • 2002
  • In this paper, we accomplish uncertainty evaluation and performance test of the volumetric interferometer using two spherical wavefronts emitted from the ends of two single mode fibers. We verify that the volumetric interferometer has the volume uncertainty of 690nm through the error analysis and it has the resolution of 0.1 0.1$\mu\textrm{m}$ for x axis which is the same order of repeatability for x axis. Also, we obtain the systematic error of $1\mu\textrm{m}$ for $60\times 60\times 20 mm^3$ working volume using self-calibration with an artifact plate.

  • PDF

Volumetric Bone Mineral Density Measurement: for Surgery Specific Bone Volumes (체적골밀도 측정법 동향: 수술부위 골밀도 분석)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.53-59
    • /
    • 2022
  • DEXA, as the standard areal bone mineral density (aBMD) measurement method, often shows an insuficient correlation between aBMDs of the measured bones and referring bones and is inaccurate due to the mass effect. In contrast, quantitative computer tomography (QCT), as a volumetric BMD (vBMD) measurement method, is being advanced so that it uses less radiation before, owing to improved CT device and computer imaging technology. Because dual-energy CTs can modulate the image signals showing tumor or specific chemicals as well as the ability to measure vBMD, they are expanding their application. For pre-checking vBMD of surgeon-specific bone volume at implantation candidate sites, a finite element creation-based local vBMD measurement technique was developed. The local vBMD measurement function for surgeon-specific shape volumes will be added to clinical imaging systems.