• Title/Summary/Keyword: Volumetric capacity

Search Result 144, Processing Time 0.027 seconds

Evaluation of Water Absorption Speed for Litter Materials to Improve the Water Control Ability of Livestock Litter (우사의 수분조절능력 향상을 위한 깔짚소재별 수분흡수속도 평가)

  • Rho, Jun-Suk;Lee, Jae-Hoon;Lee, Su-Lim;Park, Jong-Hwan;Seo, Dong-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.1
    • /
    • pp.24-31
    • /
    • 2022
  • BACKGROUND: The most common litter materials used in South Korea are sawdust, rice husk, etc. Recently, the cost of litter has been steadily rising, and the maturity test has been strengthened. For this reason, new litter materials are needed for better water control ability to solve the problems. The object of this study was to evaluate the water absorption properties for litter materials. METHODS AND RESULTS: The volumetric water capacity according to the addition of cow manure was investigated to calculate the water absorption speed of litter materials (sawdust, peatmoss, cocopeat, and biochar). The water absorption speed constant (-K) in the first stage was high in the order of cocopeat (0.1190), sawdust (0.0961), biochar (0.0762), and peatmoss (0.0523). The optimal period of the litter use was in the following order: peatmoss (48d), biochar (42d), sawdust (30d), and cocopeat (24d). The water absorption rate (%) of the used litters was high in the order of biochar ≈ cocopeat, sawdust, and peatmoss, which was significantly correlated with the water absorption speed of the first stage. CONCLUSION(S): Considering the water absorption speed and water absorption rate, biochar and peatmoss were found to be the best and optimal litter materials among the tested materials. These litter materials can be used as water control agents in livestock facilities.

Investigation on the Characteristics Variation According to Air Supply Capacity in Layer Manure by Composting (공기공급량에 따른 산란계분의 퇴비화 특성변화에 관한 연구)

  • Kwag, J.H.;Cho, S.H.;Jeong, K.H.;Kim, J.H.;Choi, D.Y.;Jeong, Y.S.;Jeong, M.S.;Kang, H.S.;Ra, C.S.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.2
    • /
    • pp.135-142
    • /
    • 2010
  • The composting of layer manure is economical and efficiently process. In this study, the variation of composting characteristics in layer manure was investigated according to air supply capacity. The fermented compost was added in layer manure and mixed with sawdust inside composting reactors. The level of air supply capacity was varied in the range of $50{\sim}200\;{\ell}/m^3/min$. During composting the temperature variations of composting piles was different the temperatures of composting piles for T-1 ($50\;{\ell}/m^3/min$) and T-2 ($100\;{\ell}/m^3/min$) were reached at $40^{\circ}C$ and $50^{\circ}C$ within 2 days, respectively. For T-3 ($150\;{\ell}/m^3/min$) and T-4 ($200\;{\ell}/m^3/min$), their temperatures was $60^{\circ}C$ within same days and maintained during 8 days. Water contents decreased according to the air supply capacity; 8.9%, 15.4%, 18.0% and 18.6% for T-1, T-2, T-3 and T-4. The weight ratios of T-1, T-2, T-3 and T-4 were reduced to 12.8%, 15.6%, 18.1% and 17.9%, respectively. The decreasing volumetric ratios of T-1, T-2, T-3 and T-4 were 18.0%, 21.0%, 22.3% and 22.0%. The oxygen discharge concentrations during composting were 12 ppm for T-1, T-2 and 9 ppm for T-3 and T-4. After composting, fertilizer components such as total nitrogen (TN) and phosphorous pentoxide ($P_2O_5$) were examined at each air supply capacity. Nitrogen contents of the T-1, T-2, T-3 and T-4 were 0.75%, 0.74%, 0.72% and 0.64%. Also, The contents of $P_2O_5$ were 0.35%, 0.40%, 0.38% and 0.42% for T-1, T-2, T-3 and T-4.

Evaluation of Methods Used in the Calculation of Condition Index Using the Mussel, Mytilus coruscus (Gould, 1861) Collected from Chuja Island, Cheju, Korea (추자도산 홍합, Mytilus coruscus (Gould, 1861) 의 Condition Index 산정에 대한 연구)

  • 강도형;최광식
    • The Korean Journal of Malacology
    • /
    • v.15 no.1
    • /
    • pp.57-62
    • /
    • 1999
  • Condition indices (Cl) are considered to be useful measurements of the nutritive and health status of bivalves although studies on Cl of bivalves are limited due to the lack of a standard formula for calculating Cl. This study attempts to generate Cl of the mussel, Mytilus coruscus inhabiting along the coastal area of Chuja Island in Cheju using three primary formulas. the formulas used in this study: (1) Cl-vol= [tissue dry weight (g) 1000] /shell cavity volume (ml). (2) Cl-wt= [tissue dry weight (g) 1000] / internal shell cavity capacity (g). (3) Cl-size= tissue wet weight (g)/[shell length (mm)]$\^$3/. Monthly condition indices calculated with the three formulas are compared using ANOVA, Duncan's multiple range test and Pearson correlation coefficient. In Chuja Island M. coruscus collected ranged from 50 to 180 mm in shell length. Monthly ranges of Cl-values were 67.48 to 140.61 (Cl-vol), 74.67 to 118.02 (Cl-wt) and 1.4 10$\^$-5) to 1.6 10$\^$-5/ (Cl-size). Cl-vol values in August were higher than two Cl-values in the other months. Monthly Cl-vol was significantly different from Cl-wt and Cl-size. (p<0.05). The results of this study suggest that volumetric condition index (Cl-vol) used in this study is acceptable as a standard measure to evaluate conditions of M. coruscus.

  • PDF

Evaluation of Hydrophilic Polymer on the Growth of Plants in the Extensive Green Roofs (저관리형 옥상녹화 식물생육을 위한 Hydrophilic polymer의 효용성)

  • Yang, Ji;Yoon, Yong-Han;Ju, Jin-Hee
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.3
    • /
    • pp.357-364
    • /
    • 2014
  • This study aimed to determine effects of the use of water-retention additive, hydrophilic polymer, for extensive green roofs on growth of Juniperus chinensis var. sargentii and Euonymus fortunei 'Emerald and Gold' for woody plants, and Carex kobomugi and Carex pumila for herbaceous plants. Five different contents of hydrophilic polymer including 0% (Control), 1.0%, 2.5%, 5.0%, and 10% (polymer: medium (w/w), dry weight basis) were added to each of the container filed with a 100 kg of growth medium. Ten of plants were transplanted in each of square container ($1m(L){\times}1m(W){\times}0.3m$ (H)) built on the roof platforms in randomized complete block design in the $20^{th}$ of May, 2013. In results, excessively high volumetric soil water content, about 97-98%, was found in the substrate under elevated hydrophilic polymer concentration of at least 2.5%, during the entire growing period. The moisture content of the substrate containing 1.0% of hydrophilic polymer was higher about 20% in the range between 70% and 80%, compared tho that of Control substrate in the range between 50% and 60%, for 27 days after transplanting prior to abundant rainfall, indicating that the application of hydrophilic polymer to the extensive green roof substrate is effective to eliminate drought condition by retaining water in the substrate. Euonymus fortunei 'Emerald and Gold' and Carex kobomugi resulting in higher plant growth with 2.5% than those of the other treatment plants. Juniperus chinensis var. sargentii was observed the highest growth under 1.0% hydrophilic polymer treatement, and Carex pumila was founded the best growth with Control respectively. Plants that grown in both the 1.0% and 2.5% hydrophilic polymer survived all, while the plants that grown in the 5.0% and 10% hydrophilic polymer died after 3 months. These results suggest that advantage of the addition of hydrophilic polymer may be greater in drought-tolerant plants, but the mixture proportion of hydrophilic polymer should be determined according to the different features of the plant species being grown.

Comparisons in Volumes of Irrigation and Drainage, Plant Growth and Fruit Yield under FDR Sensor-, Integrated Solar Radiation-, and Timer-Automated Irrigation Systems for Production of Tomato in a Coir Substrate Hydroponic System (토마토 코이어 수경재배에서 FDR센서, 적산일사량센서 및 타이머 급액방식에 따른 급배액량, 생육 및 과실수량 비교)

  • Choi, Eun-Young;Kim, Hee-Yong;Choi, Ki-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.25 no.1
    • /
    • pp.63-70
    • /
    • 2016
  • Water drainage from the open hydroponics often causes significant environmental pollution due to agrochemicals and loss of water and nutrients. The objectives of this study were to show the potential application of an irrigation schedule based on threshold values of volumetric substrate water content for tomato (Solanum lycopersicum L. 'Samsamgu') cultivation in a commercial hydroponic farm during spring to summer cultivation. This study was performed for minimizing effluent from coir substrate hydroponics using a frequency domain reflectometry (FDR) sensor-automated irrigation, as compared with an integrated solar-radiation (IR) and conventional timer-irrigation (TIMER) after transplanting. In results, no significant difference in daily irrigation volume was found among the treatments until 88 days after transplant (DAT). However, during the 88 to 107 DAT, the daily irrigation volume was in the order of IR (2125 mL) > TIMER (2063 mL) > FDR (1983 mL), and during the 108 to 120 DAT, it was in the order of IR (2000 mL) > TIMER (1664 mL) > FDR (1500 mL). The lowest drainage volume was observed in the FDR treatment with the order of IR (12~19%) > TIMER (4~12%) > FDR (0~7%) during the entire growing period. A lower irrigation volume in the FDR treatment after 88 DAT may be due to the sensor's detecting capacity for less water absorption by plant after completing fruit maturity with apical pruning and removal of lower leaves, while a higher irrigation volume in the IR treatment may be due to gradual increase in integrated solar-radiation amount as closer to summer season. There was no significant difference in plant growth and fruit yield among the treatments; however, a 11% and 18% of higher soluble sugar content was observed in the FDR than that of TIMER and IR treatment. respectively.

Contributors of the Severity of Airflow Limitation in COPD Patients

  • Hong, Yoon-Ki;Chae, Eun-Jin;Seo, Joon-Beom;Lee, Ji-Hyun;Kim, Eun-Kyung;Lee, Young-Kyung;Kim, Tae-Hyung;Kim, Woo-Jin;Lee, Jin-Hwa;Lee, Sang-Min;Lee, Sang-Yeub;Lim, Seong-Yong;Shin, Tae-Rim;Yoon, Ho-Il;Sheen, Seung-Soo;Ra, Seung-Won;Lee, Jae-Seung;Huh, Jin-Won;Lee, Sang-Do;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • Background: Although airway obstruction in chronic obstructive pulmonary disease (COPD) is due to pathologic processes in both the airways and the lung parenchyma, the contribution of these processes, as well as other factors, have not yet been evaluated quantitatively. We therefore quantitatively evaluated the factors contributing to airflow limitation in patients with COPD. Methods: The 213 COPD patients were aged >45 years, had smoked >10 pack-years of cigarettes, and had a post-bronchodilator forced expiratory volume in one second ($FEV_1$)/forced vital capacity (FVC) <0.7. All patients were evaluated by medical interviews, physical examination, spirometry, bronchodilator reversibility tests, lung volume, and 6-minute walk tests. In addition, volumetric computed tomography (CT) was performed to evaluate airway wall thickness, emphysema severity, and mean lung density ratio at full expiration and inspiration. Multiple linear regression analysis was performed to identify the variables independently associated with $FEV_1$ - the index of the severity of airflow limitation. Results: Multiple linear regression analysis showed that CT measurements of mean lung density ratio (standardized coefficient ${\beta}$=-0.46; p<0.001), emphysema severity (volume fraction of the lung less than -950 HU at full inspiration; ${\beta}$=-0.24; p<0.001), and airway wall thickness (mean wall area %; ${\beta}$=-0.19, p=0.001), as well as current smoking status (${\beta}$=-0.14; p=0.009) were independent contributors to $FEV_1$. Conclusion: Mean lung density ratio, emphysema severity, and airway wall thickness evaluated by volumetric CT and smoking status could independently contribute to the severity of airflow limitation in patients with COPD.

An Experimental Study on the Engineering Characteristics Analysis of Unsaturated Weathered Granite Soil (불포화된 화강풍화토에 대한 공학적 특성분석을 위한 실험적 연구)

  • Kim, Joon-Seok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.577-585
    • /
    • 2020
  • Purpose: The presence of the matric suction in unsaturated soil increases the stability of the slope, but the reduction of the matric suction due to precipitation can cause sudden slope failure, resulting in a major disaster. In this paper, engineering characteristics in unsaturated state were analyzed for granite weathering soil, which is the representative mountain soil of Korea. Method: Experiments and analysis were conducted on granulated weathering soil as unsaturated shear strength relationships for moisture characteristic curves, unsaturated injection curves, and matric suction under unsaturated conditions. Result: It was analyzed that a rapid change in the matric suction for volumetric water content occurs compared to the case where the particle size distribution is poor and the particle size distribution is good. A good case for the particle size distribution indicates a relatively small permeability coefficient at the same matric suction capacity compared to a poor case. The greater thematric suction, the greater the shear strength. Conclusion: For Korea's representative soil, granulated weathering soil, the functional characteristic curves, unsaturated permeability coefficients, unsaturated shear strength, etc., which are engineering characteristics in unsaturated state, were tested to secure each correlation.

Reduction of Odor Emission from Swine Excreta using Silver Nano Colloid (은 나노 콜로이드를 이용한 돼지분뇨의 악취 저감 효과)

  • Kim, Koo-Pil;Choi, Young-Soo;Oh, Kwang-Hyun;Koo, Kyung-Bon;Suh, Sang-Ryong;Yoo, Soo-Nam;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.342-347
    • /
    • 2011
  • The effect of SNC(silver nano colloid) on the emission reduction of odors such as ammonia ($NH_3$), hydrogen sulfide ($H_2S$), and methane ($CH_4$) from swine excreta was studied. Silver has been used as an universal antibiotic substance and can reduce the emission of some gases by sterilizing action. Therefore, an apparatus which produces SNC was developed and was conducted its performance test. Also, the SNC made by the apparatus was applied to swine excreta sampled from a piggery in oder to find the effect on the reduction of odor emission. An electrolysis apparatus was developed to produce SNC and its capacity was 0.024 ppm/$hr{\cdot}L$. The effects of SNC on the reduction of odor emission from swine excreta were tested for bad smell gases of ammonia ($NH_3$), hydrogen sulfide ($H_2S$) and methane ($CH_4$). For ammonia gas, factorial experiments were conducted to find the effects of concentration and application rate of SNC. The test results for the different concentrations of 20 ppm, 50 ppm, and 100 ppm showed that the more concentration of SNC was increased, the more emission reduction of ammonia gas increased. From the test results about the effect of application rate, the more SNC was applied, the more emission reduction of $NH_3$ increased. In order to reduce the concentration of $NH_3$ below 5 ppm, SNC of 50 ppm is recommended to be applied at an interval of 6 hours, and is mixed with swine excreta in the volumetric ratio of 4:1. For hydrogen sulfide gas, the concentration was decreased as time went by and was reduced rapidly in the first stage of the tests for all applied concentrations of SNC (20 ppm, 50 ppm, and 100 ppm). Especially, when 100 ml of SNC with 100 ppm was applied, emission of hydrogen sulfide gas was reduced rapidly during early 4 hours after the application of SNC. And, concentration of hydrogen sulfide gas was maintained below 20 ppm after 12 hours. For methane gas, t-test showed that there was no significance on the effect of its application for all applied concentrations of SNC. Therefore, it was concluded that the application of SNC on swine excreta had no effect on the emission reduction of $CH_4$.

Poly(phenanthrenequinone)-Poly(acrylic acid) Composite as a Conductive Polymer Binder for Submicrometer-Sized Silicon Negative Electrodes (서브마이크로미터 크기의 실리콘 음극용 폴리페난트렌퀴논-폴리아크릴산 전도성 고분자 복합 바인더)

  • Kim, Sang-Mo;Lee, Byeongil;Lee, Jae Gil;Lee, Jeong Beom;Ryu, Ji Heon;Kim, Hyung-Tae;Kim, Young Gyu;Oh, Seung M.
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.3
    • /
    • pp.87-94
    • /
    • 2016
  • In order to improve performances of submicrometer-sized Si negative electrode which shows larger volumetric change than nano-sized Si, composite binders are introduced by blending between poly(phenanthrenequinone) (PPQ) conductive polymer binder and poly(acrylic acid) (PAA) having good adhesion strength due to its carboxyl functional group. Blending between PPQ and PAA shows an effect that the adhesion strength of the Si electrode with the composite conductive binder is greatly improved after blending and this makes its better stable cycle performance. Blending ratios between PPQ and PAA in this work are 2:1, 1:1, 1:2 (by weight) and the best capacity retention at 50th cycle is observed in the electrode with the blending ratio 2:1 (named QA21). This is because that PPQ plays a role of conductive carbon among the Si particles or between Si particles and Cu current collector and PAA binds effectively the particles and the current collector. According to this synergetic effect, the internal resistance of the Si electrode with the blending ratio 2:1 is the smallest value. In addition, the Si electrode with PPQ-PAA composite binder shows the better stable cycle performance than the electrode with conventional super-P conductive carbon (20 wt.%).

Evaluation of various nutrients removal models by using the data collected from stormwater wetlands and considerations for improving the nitrogen removal (인공습지에서 영양소 제거 설계모델 검토 및 질소제거 개선방안에 대한 고찰)

  • Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.90-102
    • /
    • 2017
  • In this study, various types of nutrient models were tested by using two tears's water quality data collected from the stormwater wetland in Korea. Based on results, most important factor influencing nitrogen removal was hydraulic loading rate, which indicates that surface area of wetland is more important than its volumetric capacity, and model proposed by WEF was found to give a least error between measured and calculated values. For the phosphorus, in case assuming a power relationship between rate constant and temperature, the best prediction result were obtained, but temperature was most sensitive parameter affecting phosphorus removal. In addition, denitrification was always a limiting step for the nitrogen removal in this particular wetland mostly due to the lack of carbon source and high dissolved oxygen concentration. In this paper, several alternatives to improve nitrogen removal, including proper arrangement and designation of wetland elements and use of floating plants or synthetic fiber mat to control oxygen level and to capture the algal particles were proposed and discussed.