Performance Analysis of Orbiter Vacuum Pump (오비터 진공펌프 성능해석)

  • Shim, Jae-Hwi;Kim, Hyun-Jin
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.287-290
    • /
    • 2006
  • Orbiter mechanism has been applied to vacuum pump design for small oxygen generator where low vacuum of about 200mmHg is required. Performance of the designed vacuum pump has been numerically investigated: calculated volumetric and adiabatic efficiencies were 69.7% and 83.9%, respectively for leakage clearance of $10{\mu}m$. Total efficiency of the orbiter vacuum pump was 77.5%. At the shaft speed of 1700 rpm suction displacement volume of 6.3cc provided discharge flow at the rate of 2.3 liter/min with power consumption of 10.1Watt. Torque variation of the orbiter pump was only about 20% of that of diaphragm pump.

  • PDF

Effect of elasticity of aqueous colloidal silica solution on chemical absorption of carbon dioxide with 2-amino-2-methyl-1-propanol

  • Park, Sang-Wook;Choi, Byoung-Sik;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.3
    • /
    • pp.133-141
    • /
    • 2006
  • Carbon dioxide was absorbed into the aqueous nanometer sized colloidal silica solution of 0-31 wt% and 2-amino-2-methyl-1-propanol of $0-2kmol/m^3$ in a flat-stirred vessel with the impeller of various sizes and speeds at $25^{\circ}C$ and 0.101 MPa to measure the absorption rate of $CO_2$. The volumetric liquid-side mass transfer coefficient$(k_La)\;of\;CO_2$ was used to obtain the empirical correlation formula containing the rheological behavior of the aqueous colloidal silica solution. Reduction of the measured $k_La$ was explained by the viscoelastic properties of the aqueous colloidal silica solution. The theoretical value of the absorption rate of $CO_2$ was estimated from the model based on the film theory accompanied by chemical reaction and compared with the measured value.

Anaerobic Treatment of High Strength Organic Wastewater by Granulated Microorganism (입상미생물을 이용한 고농도 유기성폐수의 혐기성처리)

  • Rim, Jay-Myoung;Han, Dong-Joon;Jun, Tae-Sung;Lee, Hyun-Joo
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.61-70
    • /
    • 1996
  • This research aims to find granulation and organic removal of the piggery wastewater with the upflow blanket filter(UBF) reactor. UASB process had the effect of high pH on the granulation phase. But teh effect was decreased after the granule formation. The filter zone of the UBF reactor had the function of GSS and contributed to removing the organic because of its biofilm formation. The removal rates of total COD and soluble COD were 70% ~ 80% and 60 ~ 80% at an influent organic loading range of $2{\sim}17.4kgCOD/m^3{\cdot}d$, respectively. The methane production rate with the organic removal was $0.21{\sim}0.34{\ell}CH_4/gCOD_{rem}$ and the maximum methan production rate was $0.34CH_4{\ell}/gCOD_{rem}$ at the volumetric loading $5kgCOD/m^3{\cdot}d$.

  • PDF

Treatment of Dyeing Wastewater by Magnetic-Biological Treatment System (자화-생물처리 시스템에 의한 염색폐수의 처리)

  • Lee, Seon-Ha
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.371-377
    • /
    • 2010
  • The purpose of this study is to investigate treatment efficiency in dyeing wastewater treatment by the high rate aeration system(HRA) and a combination of the HRA with magnetized wastewater treatment system(MWS). At the hydraulic retention time of 16hr, 24hr, 30hr, BOD removal efficiencies of HRA system were 93%, 96% and 98%, combination of the HRA with MWS system were 94%, 96.8% and 98.2%, respectively. In ease of COD, at the hydraulic retention time of 16hr, 24hr, 30hr, COD removal efficiencies of HRA system were 66%, 77.1% and 83.1%, combination of the HRA with MWS system were 70.2%, 80.1% and 86.6%, respectively. The comparison of the HRA and combination of the HRA with MWS, effluent BOD of the former was 22.7mg/${\ell}$ and the latter was 19.4mg/${\ell}$, theretore biological treatment efficiency identified to increase by the MWS.

Comparison of Infiltration Rate of Slope in Model Test and Finite Element Analysis (모형시험과 유한요소해석에서 비탈면 강우의 침투량 비교)

  • Yu, Yong-Jae;Kim, Jae-Hong
    • Land and Housing Review
    • /
    • v.9 no.2
    • /
    • pp.51-57
    • /
    • 2018
  • The causes of landslides are dependant on rainfall events and the soil characteristics of a slope. For the conventional slope stability, the slope stability analysis has been carried out assuming the saturated soil theory. But, in order to clearly explain a proper soil slope condition by rainfall, the research should be performed using the unsaturated soil mechanism suitable for a soil slope in the field. In the study, by using two major categories of soils in Korea, such as granite and gneiss weathered soils, landslide model test and finite element method have been compared with the difference of seepage and soil stability analysis. The hydraulic conductivity of gneiss weathered soil is slower than that of granite weathered soil, and the gneiss weathered soil contains much finer soils than the granite weathered soil. It was confirmed that the instability of the slope was progressing slowly due to the slow rate of volumetric water content of the surface layer.

Nitrogen Removal in the Multi-stage Bed Attached Growth Process of $A^2/O$ System with Interanal Recycle Ratio (다단층 부착성장 공법($A^2/O$향)에서 순환비에 따른 질소제거)

  • 최규철;윤용수;정일현
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.95-102
    • /
    • 1997
  • The process which can stabilize water quality of treatment and improve nitrogen removal rate under the condition of high organic loading was developed by charging fibrous HBC media to single sludge nitrification-denitrification process. This process was operated easier, minimized the treatment cost, and shortened the retention time. To improve T-N removal rate, a part of nitrifing liquid at aerobic zone was recycled to anoxic zone by approximate internal recycle ratio. The experimental results are as follows ; T-N removal efficiency in the organic volumetric loading 0.14-0.19 kg/COD/m$^{3}$·d was obtained asmaxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.

  • PDF

Development of experimental apparatus to evaluate frost heave and pressure (토사의 동상량 및 동상력 측정을 위한 실내 실험장치 개발)

  • Ko, Sung-Gyu;Choi, Chang-Ho;Chae, Jong-Gil
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.131-137
    • /
    • 2010
  • `Frost heave' is volumetric extension behavior of soil due to freezing. It could have a bad effect to foundations of infrastructures like building, road, railroad and bridge. Therefore, it is considered as a primary design parameter with 'adfreeze bond' and 'creep deformation' for foundation design in cold region. In some countries, studies for analyzing frost heave in many ways have being performed, however, only a few studies for evaluating frost susceptibility of soils by measuring frost heave rate of frozen soils in Korea. For analyzing frost heave as a foundation design parameter, both frost heaving rate and heaving pressure are should be addressed in study. Hence, in this study, development of experimental apparatus to evaluate frost heave and pressure is suggested.

  • PDF

Performance Analysis of Variable Valve for Diesel Engine with Cam-in-Cam System (디젤엔진용 Cam-in-Cam시스템 적용 가변밸브 성능해석)

  • Jeong, S.C.;Park, J.M.;Kim, T.K.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.22 no.1
    • /
    • pp.22-28
    • /
    • 2017
  • In this study, the effects of intake valve closing timing by using Cam-in-Cam system on combustion and emission characteristics for diesel engine were investigated under GT-POWER simulation environment. As a result, it was found that volumetric efficiency and effective compression ratio were decreased as the intake valve closing(IVC) timing is retarded due to its backflow effect. Also, we found that in-cylinder pressure, heat release rate and NOx emission were decreased as IVC timing was retarded. These show that the LIVC(late intake valve closing) can be effective to control AFR and mixing rate in diffusion combustion of diesel engine.

Performance Analysis of Orbiter Vacuum Pump (오비터 진공펌프 성능해석)

  • Kim, Hyun-Jin;Shim, Jae-Hwi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.5 s.38
    • /
    • pp.28-35
    • /
    • 2006
  • Orbiter mechanism has been applied to vacuum pump design for small oxygen generator where low vacuum of about 200 mmHg is required. Performance of the designed vacuum pump has been numerically investigated: calculated volumetric and adiabatic efficiencies were 69.7% and 83.9%, respectively for leakage clearance of $10{\mu}m$. Total efficiency of the orbiter vacuum pump was 77.5%. At the shaft speed of 1700 rpm suction displacement volume of 6.3cc provided discharge flow at the rate of 2.3 liter/min with power consumption of 10.1Watt. Torque variation of the orbiter pump was only about 20% of that of diaphragm pump.

Diagnosing Plant Pipeline System Performance Using Radiotracer Techniques

  • Kasban, H.;Ali, Elsayed H.;Arafa, H.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.196-208
    • /
    • 2017
  • This study presents an experimental work in a petrochemical company for scanning a buried pipeline using $Tc^{99m}$ radiotracer based on the measured velocity changes, in order to determine the flow reduction along a pipeline. In this work, $Tc^{99m}$ radiotracer was injected into the pipeline and monitored by sodium iodide scintillation detectors located at several positions along the pipeline. The flow velocity has been calculated between every two consecutive detectors along the pipeline. Practically, six experiments have been carried out using two different data acquisition systems, each of them being connected to four detectors. During the fifth experiment, a bypass was discovered between the scanned pipeline and another buried parallel pipeline connected after the injection point. The results indicate that the bypass had a bad effect on the volumetric flow rate in the scanned pipeline.