• Title/Summary/Keyword: Volume resistance

Search Result 1,037, Processing Time 0.032 seconds

Electrical and Mechanical Properties of Semiconductive Composites for DC Power Cable (직류 전력케이블용 반도전 복합체의 전기적·기계적 특성)

  • Lee, Ki-Joung;Seo, Bum-Sik;Yang, Jong-Seok;Seong, Baeg-Yong;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.2
    • /
    • pp.119-125
    • /
    • 2013
  • In this paper, semiconducting shield specimens for a DC cable is fabricated and characterized by measurement of volume resistance, tensile strength, and the coefficient of expansion to show the electrical and mechanical characteristics of the semiconducting shield. Due to the PTC phenomenon, the volume resistance at $25^{\circ}C$ increases rapidly in comparison to the volume resistance at $90^{\circ}C$. Since the compounding ratio of carbon black is low, the tensile strength and density become lower and the coefficient of expansion is increased. As the general specification of the tensile strength and density is $0.8kgf/mm^2$ and 150%, respectively, the fabricated specimen in this paper has excellent mechanical characteristic.

Study of Corrosion Resistance in Super-Duplex, Tungsten-Containing Stainless Steel (텅스텐이 첨가된 슈퍼 2상 스테인리스강의 내부식성에 관한 연구)

  • Choi, Han-Gul;Park, Hyung-Gyun;Jung, Byung-Ho;Han, Hyun-Sung;Bae, Dong-Su;Kang, Chang-Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.55-59
    • /
    • 2010
  • The effect of aging on the precipitation of the $\sigma$ phase and corrosion resistance in W-substituted, super-duplex stainless steel was investigated. The volume fraction of the $\sigma$ phase and the current density increased as the aging temperature increased up to $750^{\circ}C$, and, then, they decreased. As aging time increased, the volume fraction of the $\sigma$ phase and the current density also increased. The $\sigma$ phase considerably influenced to corrosion resistance. When Mo was substituted for W in super-duplex stainless steel, the volume fraction of the $\sigma$ phase and the current density both decreased markedly.

The Effect of Aging Treatment on the Corrosion Resistance in Super Duplex Stainless Steel with Added W (텅스텐이 첨가된 슈퍼 2상 스테인리스강의 내식성에 미치는 시효처리의 영향)

  • Kim, Soo-Chun;Choi, Han-Gul;Kim, Yun-Kyu;Park, Young-Tae;Lee, Jong-Mun;Park, Jin-Hwan;Kang, Chang-Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.87-92
    • /
    • 2009
  • The effect of aging on the precipitation of the $\sigma$ phase and the corrosion resistance in tungsten substituted super duplex stainless steels was investigated. The volume fraction of the $\sigma$ phase and the current density increased with aging at temperatures up to $750^{\circ}C$ and then decreased. With an increase in aging time, the volume fraction of the $\sigma$ phase and the current density also increased. The $\sigma$ phase hardly influenced the corrosion resistance. With the substitution of tungsten for molybdenum in super duplex stainless steel, the volume fraction of the $\sigma$ phase and the current density decreased remarkably.

Dynamic tensile behavior of SIFRCCs at high strain rates

  • Kim, Seungwon;Park, Cheolwoo;Kim, Dong Joo
    • Computers and Concrete
    • /
    • v.26 no.3
    • /
    • pp.275-283
    • /
    • 2020
  • Reinforced concrete (RC) does not provide sufficient resistance against impacts and blast loads, and the brittle structure of RC fails to protect against fractures due to the lack of shock absorption. Investigations on improving its resistance against explosion and impact have been actively conducted on high-performance fiber-reinforced cementitious composites (HPFRCCs), such as fiber-reinforced concrete and ultra-high-performance concrete. For these HPFRCCs, however, tensile strength and toughness are still significantly lower compared to compressive strength due to their limited fiber volume fraction. Therefore, in this study, the tensile behavior of slurry-infiltrated fiber-reinforced cementitious composites (SIFRCCs), which can accommodate a large number of steel fibers, was analyzed under static and dynamic loading to improve the shortcomings of RC and to enhance its explosion and impact resistance. The fiber volume fractions of SIFRCCs were set to 4%, 5%, and 6%, and three strain rate levels (maximum strain rate: 250 s-1) were applied. As a result, the tensile strength exceeded 15 MPa under static load, and the dynamic tensile strength reached a maximum of 40 MPa. In addition, tensile characteristics, such as tensile strength, deformation capacity, and energy absorption capacity, were improved as the fiber volume fraction and strain rate increased.

온도 변화에 따른 Nano/Micro $SiO_2$ 혼합 Epoxy의 체적고유저항 특성

  • Kim, Jeong-Sik;Jeong, In-Beom;Ryu, Bu-Hyeong;Kim, Gwi-Yeol;Hong, Jin-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.153-153
    • /
    • 2009
  • In the study the volume resistivity Characteristics of epoxy resin using nano and micro filler, nano and micro filler are made from insulating material epoxy resin using for transformer equipment and molding several devices as changing amount of addition of diameter 12 [nm] and 7 [${\mu}m$] $SiO_2$, we measured volume resistivity of nano and micro filler by High Resistance Meter(4329A). As the result of measurement, When is micro filler, the volume resistivity continuously increased over 80 [$^{\circ}$].

  • PDF

The Analysis of change of insulation resistance by filler on low voltage multi core cables (저압다심케이블에서 충진물(개재물)이 절연저항에 미치는 영향 분석)

  • Ko, Young-Hoon;Park, Eui-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.71-72
    • /
    • 2007
  • The insulation is a important part of cable. In thisb paper, measured the insulation resistance for analysing of change of insulation resistance by filler on low voltage multicore cables. The insulation resistance is not effected by only insulation material, but also filler material. The insulation resistance is different with measuring before filling and after filling by filler. When develope the new filler or cable, the volume resistance of filler must be considered.

  • PDF

Low streee Abrasive Wer mechanism of the Iron/Chromium Hardfacing Alloy (저응력하의 철/크롬 올버레이합금의 긁힘마모기구)

  • 백응률
    • Journal of Welding and Joining
    • /
    • v.16 no.2
    • /
    • pp.73-83
    • /
    • 1998
  • This study investigated the relationships between the microstructure and the wear resistance of hardfaced iron/chromium alloys to examine the low stress abrasive wear mechanism. The effects of volume fraction of reinforcing phases(chromium carbide and eutectic phase) were studied. The alloys were deposited once or twice on a mild steel plate using a self-shielding flux cored arc welding process. The low stress abrasion resistance of he alloys against dry sands was measured by the Dry Sand/Ruber Wheel Abrasion Tester (RWAT). The wear resistance of hypoeutectic alloys, below 0.36 volume fraction of chromium-carbide phase (VFC), behaved as Equal Pressure Mode (EPM) for the inverse rule of mixture whereas the wear resistance of hypereutectic alloys, above 0.36 VFC, represented Equal Wear Mode (EWM) for the linear rule of mixture.

  • PDF

Permeability and abrasion resistance of concretes containing high volume fine fly ash and palm oil fuel ash

  • Homwuttiwong, S.;Jaturapitakkul, C.;Chindaprasirt, P.
    • Computers and Concrete
    • /
    • v.10 no.4
    • /
    • pp.349-360
    • /
    • 2012
  • In this paper, compressive strength, water permeability and abrasion resistance of concretes containing high volume fine fly ash (FFA) and fine ground palm oil fuel ash (GPA) were studied. Portland cement type I was replaced with FFA and GPA at dosages up to 70% by weight of binder. Ground river sand (GRS) was also used to replace Portland cement in order to indicate the level of filler effect. Results indicated that FFA was slightly more reactive than GPA. The replacement of 40-70% of FFA produced concretes with compressive strength, permeability and abrasion resistance comparable to those of normal concretes. The incorporation of GPA slightly reduced the performances of concretes as compared to those of FFA concretes. The reduction of Portland cement was partly compensated by the increase in pozzolanic activity of the fine fly ash and palm oil fuel ash and thus enabled the large replacement levels.

Effect of Smoking on Nasal Resistance (흡연이 비저항에 미치는 영향)

  • Oh, Cheon-Hwan;Kim, Jang-Wook
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.2
    • /
    • pp.113-118
    • /
    • 1999
  • Background & Objectives : Nasal resistance which is halfly responsible for airway resistance is known to be influenced by hypoxia, hypercapnia, exercise, pregnancy, alcohol, ammonia and smoking. Smoking is a common part of our sociocultural environment and we have many a times been introduced to its various adverse effects, which have usually been more focused on lung problems. The purpose of this study is to determine any relationship between smoking and nasal resistance and to evaluate it's effective sites. Materials and Methods : Acoustic rhinometry was performed in 25 smokers and 25 nonsmokers who had no nasal symptoms nor abnormal rhinoscopic findings, and used an acoustic rhinometry to measure the distance from nose-piece to the C-notch, cross sectional area at the C-notch, and volume of the nasal cavity from nose-piece to 7cm. The authors compared the data between the two groups. Results : The cross sectional area at the C-notch was significantly decreased(p<0.05) in smoking group. The distance to the C-notch and the volume of nasal cavity were decreased likely in smoking group but there were no significant difference(p>0.05). Conclusion : Smoking reduced the cross sectional area at the C-notch, so increased the nasal resistance. The underlying mechanisms seems to be decreased nasal mucosal reactivity and congestion of the nasal mucosa. The authors believe there should follow more studies on pathophysiologic mechanisms and the histopathologic changes which involve the effect of smoking on nasal structures.

  • PDF

Effect of Low-intensity Resistance Training with Blood Flow Restriction on Muscle Volume and Strength in Elderly Women (저강도의 저항성 운동 시 혈류제한 적용이 노인여성의 근 비대와 근력 향상에 미치는 영향)

  • Yeo, Hyo-Seong;Kim, Hyo-Jeong
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.1
    • /
    • pp.535-544
    • /
    • 2015
  • This study was performed to determine the effect of low-intensity resistance training with blood flow restriction (BFR) on muscle volume and strength in elderly women. Sixteen elderly women (70.9±4.6 years) were divided into low (30% 1RM) and high (75% 1RM) intense resistance training groups. Tourniquet cuff (Zimmer, Germany) for BFR was applied only to the right leg during the training period. All subjects performed unilateral leg press, leg extension and leg curl (3 sets×12 repetitions) for 10 weeks (2d/wk). Blood pressure was increased from 110 to 240 mmHg during the training period at the most proximal region of exercised leg. Muscle volume and cross-sectional area (CSA) were measured by MRI and body composition was monitored by dual-energy X-ray absorptiometry (DEXA) and isokinetic muscular strength were analyzed in both legs. The quadriceps CSA (15.2%, p<.001) and muscle volume (13.8%, p<.001) were increased in high-intense trained leg with BFR and the increased rate was highest among groups. The quadriceps CSA (9.8%, p<.001) and muscle volume (6.9%, p<.001) were increased in low-intensity training group with BFR and their increased rates were higher than control groups. The strength by exercise training was significantly improved in all groups and tended to be higher in BFR groups. These results demonstrate low-intensity resistance training with blood flow restriction could be an effective way to improve muscle volume and strength in elderly women.