• Title/Summary/Keyword: Volume rendering technique

Search Result 68, Processing Time 0.03 seconds

A Study on the Usefulness of 3D Imaging in Micro-CT for Observing the Microstructure of Mice (흰쥐 미세구조 관찰을 위한 Micro-CT 3D 영상의 유용성에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Lim, Cheong-Hwan;Jung, Hong-Ryang;Chai, Kyu-Yun;Han, Beom-Hee;Han, Sang-Hyun;Hong, Dong-Hee;Han, Tae-Jong;Park, Sung-Hoon;Mo, Eun-Hee;Jun, Hong-Young
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.367-375
    • /
    • 2014
  • In this thesis we observe microvascular structure in mice by using micro-computed tomography (CT), which is high-resolution X-ray imaging equipment that can acquire Real-time dynamic image, and it aims to investigate the usefulness of micro-CT developed by Institute for Radiological Imaging Science Wonkwang University School of Medicine. After acquiring the systemic images of rats, contrast-enhanced 3D images of vascular structures could be acquired by using Maximum Intensity Projection (MIP) and Volume Rending Technique (VRT), This was divided into each vascular system of head, abdomen and heart and systemic vascular system.

A Study on Minimal Expression Techniques Depicted in Modern Fashion Design (현대패션에 나타난 최소표현기법에 관한 연구)

  • 김은덕;김민자
    • Journal of the Korean Society of Costume
    • /
    • v.24
    • /
    • pp.157-176
    • /
    • 1995
  • The purpose of this treatise is to study external form and internal meaning of minimal expression fashion which appeared as a major stream in modern fashion trends to understand one aspect of modernism in fashion and also to gain insight into internal value of human beings through fashion. The results can be summarized as follows : Firstly , minimalism is a trend in art attempting to seek essence of the object by presenting simple and disciplined expressions by minimal formative means and minimal production process. Secondly, minimal expression in fashion means seeking simplicity an dpurity by using minimum design elements and minimal productive process. Thirdly, external from of minimal expression fashion can be created through application of following minimal expression techniques. 1. Minimal expression techniques in terms of line mean smooth curve flowing along body contours, straight lines of diagonal lines into desciplined silhouette or rendering internal contour lines. 2. Minimum expression techniques in terms of forms mean forms of smooth curves flowing along boyd or forms with simple geometric forms from qualitative aspects, In terms of volume it means quest for essence of pure body itself by revealing body as it is by minimizing the size of dress or its area and herein is contained using simple geometric pattern or utilizing textiles without any patterns.3. Minimal expression techniques by colors mean simple colors such as primary colors, colors without clear distinctions or natural colors and in terms of quantity it means quest for one color within one item of dress or combination of each items when getting dressed. 4. Minimal expression techniques in terms of fabrics mean fabrics with simple surfaced. In terms of quantity it means quest for essence of tight fitting thin textiles to human body or using transparent materials to human body thus exposing body contours as it is. 5. Minimal expression techniques in terms of productive process mean minimizing process of tailoring , sewing or ornamenting and seeking for simplicity and purity. 6. Minimal expression techniques in terms of manufacturing process mean selection of technique conveying simple image with disciplined simple image. Fourthly, minimal expression fashion with external expression as mentioned in the above lay body-priority style and its internal meaning can be asummed as quest for essence and purity of human body.

  • PDF

Verification of Dose Evaluation of Human Phantom using Geant4 Code (Geant4 코드를 사용한 인체팬텀 선량평가 검증)

  • Jang, Eun-Sung;Choi, Ji-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.529-535
    • /
    • 2020
  • Geant4 is compatible with the Windows operating system in C++ language use, enabling interface functions that link DICOM or software. It was simulated to address the basic structure of the simulation using Geant4/Gate code and to specifically verify the density composition and lung cancer process in the human phantom. It was visualized using the Gate Graphic System, i.e. openGL, Ray Tracer: Ray Tracing by Geant4 Tracing, and using Geant4/Gate code, lung cancer is modeled in the human phantom area in 3D, 4D to verify the simulation progress. Therefore, as a large number of new functions are added to the Gate Code, it is easy to implement accurate human structure and moving organs.

A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife (입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.149-158
    • /
    • 1996
  • Purpose : To get an accute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic trans-multiarc beam mode based on linear accelerator photon beam. Materials and methods : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. The dose distribution from the combined two trans-multiarcs (2M 2TM) was compared to that of four non-coplanar multiarcs (4M) with same collimator size of 25 mm in a diameter and total gantry movements. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusions : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments, the absorbed dose has been decreased to $27%$ / mm in maximum at the interval of $50\%$ to $80\%$ of isodose line.

  • PDF

Automatic Lower Extremity Vessel Extraction based on Bone Elimination Technique in CT Angiography Images (CT 혈관 조영 영상에서 뼈 소거법 기반의 하지 혈관 자동 추출)

  • Kim, Soo-Kyung;Hong, Helen
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.12
    • /
    • pp.967-976
    • /
    • 2009
  • In this paper, we propose an automatic lower extremity vessel extraction based on rigid registration and bone elimination techniques in CT and CT angiography images. First, automatic partitioning of the lower extremity based on the anatomy is proposed to consider the local movement of the bone. Second, rigid registration based on distance map is performed to estimate the movement of the bone between CT and CT angiography images. Third, bone elimination and vessel masking techniques are proposed to remove bones in CT angiography image and to prevent the vessel near to bone from eroding. Fourth, post-processing based on vessel tracking is proposed to reduce the effect of misalignment and noises like a cartilage. For the evaluation of our method, we performed the visual inspection, accuracy measures and processing time. For visual inspection, the results of applying general subtraction, registered subtraction and proposed method are compared using volume rendering and maximum intensity projection. For accuracy evaluation, intensity distributions of CT angiography image, subtraction based method and proposed method are analyzed. Experimental result shows that bones are accurately eliminated and vessels are robustly extracted without the loss of other structure. The total processing time of thirteen patient datasets was 40 seconds on average.

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.

A Study on the Frequency of Occurrence of the Aortic Dissection using CT (CT 검사에서 대동맥박리(aortic dissection)의 발생빈도에 관한 고찰)

  • Dong, Kyung-Rae;Choi, Sung-Kwan;Jang, Young-Ill;Ro, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.115-121
    • /
    • 2008
  • Purpose: Aortic Dissection is very dangerous, prognostic disease, which the bloodstream flow out of the true lumen of the aorta by the bursting of aortic intima resulting in a rapid dissociation of inner and outer layer from the media. It is difficult to diagnose aortic dissection clinically by normal X-ray. This study was to investigate the occurrence frequency by age and number of patients who are identified to be aortic dissection by CT (Computed Tomography) scan. Materials and methods: We investigated the trend of yearly fluctuation, gender, age, and department of clinical research of the 112 patients who conducted CT scan in C- University Hospital for two years from January 2005 to December 2006. The MIP and SSD which reconstructed CT image and the VRT image were obtained for the accurate observation. The result was investigated by comparing normal X-ray and CT scan. Results and Conclusion: 1. The yearly check of 112 patients conducted CT scan showed 37 people (41.9%) in 2005, and it was increased to 65 (58.1%) in 2006 by 1.4 times. 2. The gender distribution of patients given a CT scan showed 45 males (40.1%), and female 67 (59.9 %). The aortic dissection patients were 9 (20%) out of 45 males, 21 (31.3%) out of 67 females and women were 1.6 times more than men. Women are also 1.5 times more than men in the number of examinee. 3. The age distribution of patient's who conducted CT scan revealed that there was no patient under 30 years old while 88.3% of all patients were through 41 to 80 years old. The higher the age was, the higher the occurrence of aortic dissection was. The difference in the occurrence frequency of age was statistically significant (p<0.01). 4. The departments that requested CT scan were the emergency department 46 (41.1%), circulatory internal medicine 37 (33.0%), chest surgery 13 (11.6%), and others 6 (14.3%). The combined ratio of emergency medicine and circulatory internal medicine was 74.1% of all. The results show that the aortic dissection is a very dangerous disease whose patients visit mainly via the emergency room. 5. The aortic dissection patients had normal X-ray readings in 22 (73.3%) out of 30, and only 8 (26.7 percent) are abnormal in the X-ray diagnosis. Therefore, the CT scan needs to be enforced in order to assess accurately the disease of aortic dissection.

  • PDF

Measurement of the Mucosal Surface Distance in the Early Gastric Cancer Using CT Gastrography (조기 위암에서 CT Gastrography를 이용한 위점막 표면 거리 측정)

  • Choi, Hyang-Hee;Yu, Wan-Sik;Ryeom, Hun-Kyu;Lee, Jae-Hyuk;Choi, Jae-Jeong;Kim, Hee-Su;Cleary, Kevin;Mun, Seong-Ki;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.161-166
    • /
    • 2006
  • Purpose: Recently, the incidence of early gastric cancer (EGC) patients is rapidly increased in Korea. However, they're often not perceptible by surgical palpation or inspection. The aim of this study is 1) to develope a software that can locate the tumor and measure the mucosal distance from an anatomic landmark to the tumor using CT gastrography and 2) to compare the distance measured by the developed software with the distance measured by the pathologic findings. Materials and Methods: Between January 2004 and September 2005, sixty patients (male=45, female=15, mean 57.8 years old) estimated for EGC with preoperative CT scans and undergone gastrectomies in Kyungpook National University Hospital were enrolled in this study. Preoperative CT scans were performed after insufflations of room air via 5 Fr NG tube. The scans included the following parameters: (slice thickness/reconstruction interval: 0.625 mm, kVp: 120, mAs: 200). 3D volume rendering and measurement of the surface distance from the pylorus to the EGC were performed using the developed software. Results: The average difference between the lesion to pylorus distances measured from pathologic specimens and CT gastrography was $5.3{\pm}2.9\;mm(range,\;0{\sim}23\;mm)$. The lesion to pylorus distance measured from CT gastrography was well correlated with that measured from the pathologic specimens (r=0.9843, P<0.001). Conclusion: These results suggest that the surface distance from an anatomic landmark to the EGC can be measured accurately by CT gastrography. This technique could be used for preoperative localization of early gastric carcinomas to determine the optimal extent of surgical resection.

  • PDF