• Title/Summary/Keyword: Volume reconstruction

Search Result 400, Processing Time 0.031 seconds

The effect of early arm exercise on drainage volume after total mastectomy and tissue expander insertion in breast cancer patients: a prospective study

  • Joo, Oh Young;Moon, Seung Jin;Lee, Dong Won;Lew, Dae Hyun;Lee, Won Jai;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.583-589
    • /
    • 2021
  • Background In prosthesis-based breast reconstruction patients, the drain tends to be kept in place longer than in patients who undergo only mastectomy. Postoperative arm exercise also increases the drainage volume. However, to preserve shoulder function, early exercise is recommended. In this study, we investigated the effect of early exercise on the total drainage volume and drain duration in these patients. Methods We designed a prospective randomized trial involving 56 patients who underwent immediate breast reconstruction following mastectomy using tissue expanders. In each group, the patients were randomized either to perform early arm exercises using specific shoulder movement guidelines 2 days after surgery or to restrict arm movement above the shoulder height until drain removal. The drain duration and the total amount of drainage were the primary endpoints. Results There were no significant differences in age, height, weight, body mass index, or mastectomy specimen weight between the two groups. The total amount of drainage was 1,497 mL in the early exercise group and 1,336 mL in the exercise restriction group. The duration until complete removal of the drains was 19.71 days in the early exercise group and 17.11 days in the exercise restriction group. Conclusions Exercise restriction after breast reconstruction did not lead to a significant difference in the drainage volume or the average time until drain removal. Thus, early exercise is recommended for improved shoulder mobility postoperatively. More long-term studies are needed to determine the effect of early exercise on shoulder mobility in prosthesis-based breast reconstruction patients.

Assessment of Breast Volume Change after Transverse Rectus Abdominis Myocutaneous Flap

  • Park, Sang Uk;Shim, Jeong Su
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.631-635
    • /
    • 2012
  • Background The evaluation of a breast after breast reconstruction depends on a surgeon's subjective criteria. We used computed tomography (CT) scans to obtain an objective evaluation of the postoperative results by measuring the breast volume of patients who had undergone breast reconstruction using pedicled transverse rectus abdominis myocutaneous (TRAM) flaps. This research will help in the objective postoperative evaluation of reconstructed breasts, and also in the preoperative flap size designs. Methods A total of 27 patients underwent breast reconstruction using pedicled TRAM flaps after mastectomy from September 2007 to July 2010. Of these, 10 patients who were followed up and underwent CT scans 2 or more times during the follow-up period were included in this study. We evaluated the change in breast volume over time using CT scans, and the interval breast volume change between CT scans. Results All of the 10 patients' reconstructed breasts showed a volume decrease over time. The breast volume changes in the intervals between CT scans were as follows: 5.65% decrease between the first CT and second CT scan, 2.3% decrease between the second CT and third CT scan, (statistically significant) and 1.89% decrease between the third CT and forth CT scan. (not statistically significant). Conclusions This research shows the possibility of objectively evaluating the postoperative breast volume changes. The findings will be helpful in designing the size of TRAM flaps to use on defects after mastectomy. Based on these results, we should also closely observe the reconstructed breast volume for at least 2 years.

Hybrid Model Representation for Progressive Indoor Scene Reconstruction (실내공간의 점진적 복원을 위한 하이브리드 모델 표현)

  • Jung, Jinwoong;Jeon, Junho;Yoo, Daehoon;Lee, Seungyong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.21 no.5
    • /
    • pp.37-44
    • /
    • 2015
  • This paper presents a novel 3D model representation, called hybrid model representation, to overcome existing 3D volume-based indoor scene reconstruction mechanism. In indoor 3D scene reconstruction, volume-based model representation can reconstruct detailed 3D model for the narrow scene. However it cannot reconstruct large-scale indoor scene due to its memory consumption. This paper presents a memory efficient plane-hash model representation to enlarge the scalability of the indoor scene reconstruction. Also, the proposed method uses plane-hash model representation to reconstruct large, structural planar objects, and at the same time it uses volume-based model representation to recover small detailed region. Proposed method can be implemented in GPU to accelerate the computation and reconstruct the indoor scene in real-time.

Cell-Based Wavelet Compression Method for Volume Data (볼륨 데이터를 위한 셀 기반 웨이브릿 압축 기법)

  • Kim, Tae-Yeong;Sin, Yeong-Gil
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.26 no.11
    • /
    • pp.1285-1295
    • /
    • 1999
  • 본 논문은 방대한 크기의 볼륨 데이타를 효율적으로 렌더링하기 위한 셀 기반 웨이브릿 압축 방법을 제시한다. 이 방법은 볼륨을 작은 크기의 셀로 나누고, 셀 단위로 웨이브릿 변환을 한 다음 복원 순서에 따른 런-길이(run-length) 인코딩을 수행하여 높은 압축율과 빠른 복원을 제공한다. 또한 최근 복원 정보를 캐쉬 자료 구조에 효율적으로 저장하여 복원 시간을 단축시키고, 에러 임계치의 정규화로 비정규화된 웨이브릿 압축보다 빠른 속도로 정규화된 압축과 같은 고화질의 이미지를 생성하였다. 본 연구의 성능을 평가하기 위하여 {{}} 해상도의 볼륨 데이타를 압축하여 쉬어-? 분해(shear-warp factorization) 알고리즘에 적용한 결과, 손상이 거의 없는 상태로 약 27:1의 압축율이 얻어졌고, 약 3초의 렌더링 시간이 걸렸다.Abstract This paper presents an efficient cell-based wavelet compression method of large volume data. Volume data is divided into individual cell of {{}} voxels, and then wavelet transform is applied to each cell. The transformed cell is run-length encoded according to the reconstruction order resulting in a fairly good compression ratio and fast reconstruction. A cache structure is used to speed up the process of reconstruction and a threshold normalization scheme is presented to produce a higher quality rendered image. We have combined our compression method with shear-warp factorization, which is an accelerated volume rendering algorithm. Experimental results show the space requirement to be about 27:1 and the rendering time to be about 3 seconds for {{}} data sets while preserving the quality of an image as like as using original data.

Tomographic Reconstruction of Asymmetric Soot Structure from Multi-angular Scanning (다각 주사법을 이용한 비대칭 매연분포의 재구성)

  • Lee, Sang-Min;Hwang, Jun-Young;Chung, Suk-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.3
    • /
    • pp.24-30
    • /
    • 2003
  • A convolution algorithm combined with Fourier transformation has been applied to the tomographic reconstruction of asymmetric soot structure to identify the local soot volume fraction distribution. Line-of-sight integrated data from light extinction measurement with multi-angular scanning formed basic information for the deconvolution. Multi-peak following interpolation technique was applied to obtain the effect of increasing number of scanning angles. Height-by-height reconstructed soot volume fraction distribution was compared with laser-induced incandescence signals.

  • PDF

Light-Microscopy-Based Sparse Neural Circuit Reconstruction: Array Tomography and Other Methods

  • Rah, Jong-Cheol
    • Applied Microscopy
    • /
    • v.46 no.4
    • /
    • pp.176-178
    • /
    • 2016
  • Efficient neural circuit reconstruction requires sufficient lateral and axial resolution to resolve individual synapses and map a large enough volume of brain tissue to reveal the molecular identity and origin of these synapses. Sparse circuit reconstruction using array tomography meets many of these requirements but also has some limitations. In this minireview, the advantages and disadvantages of applicable imaging techniques will be discussed.

Breast Reconstruction Using Free TRAM Flap in Korean Women (유리 횡복직근 근피판술에 의한 한국여성의 유방재건술)

  • Ahn, Hee-Chang;Kim, Jeong-Cheol
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.84-91
    • /
    • 1999
  • The female breast is a potent symbol of maternity, sexuality, and feminity. Unfortunately, the frequency of breast cancer and mastectomy are increasing in Korea, so the reconstruction of breast becomes a important surgical procedure. The purpose of this study is to analyze the results of breast reconstruction using free TRAM flap and to suggest the operative techniques for more successful results. This study is based on a series of 39 cases of breast reconstruction using free TRAM flap in mastectomized patients. Among these cases, 21 patients underwent immediate reconstruction and 18 patients underwent delayed reconstruction. 2 patients underwent immediate bilateral reconstruction. The postoperative courses of these cases are uneventful. Breast reconstruction following mastectomy is one of the most challenging problems in plastic surgery. Nowadays the free TRAM flap is accepted as an excellent method of autogenous tissue breast reconstruction. We conclude that this technique has advantages as follows. The free TRAM flap has not associated with the complications of implant-based reconstruction. It provides sufficient volume for ptotic and natural breast, easily concealed donor site, and secondary aesthetic benefit of abdominoplasty. Unlike conventional pedicled TRAM flap, it has superiority in blood supply, and can make liberal setting of flap and sparing of rectus muscle. So it can provide more satisfaction about the final result of breast reconstruction.

  • PDF

A Volume Reconstruction Algorithm and a Coordinate Calibration of an X-ray Three Dimensional Imaging System

  • Roh, Young-Jun;Cho, Hyung-Suck;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.63.3-63
    • /
    • 2001
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. In this paper, we propose a three dimensional volume reconstruction method, which is an iterative method and as uniform and simulated algebraic reconstruction technique (USART). In this method, two or more x-ray images projected from different views are needed, and also the geometry of the imaging system need to be a priori identified well. That is to say, the relative locations between the x-ray source, imaging plane and the object should be determined exactly by calibration. To achieve this, we propose a series of coordinate calibration methods of the x-ray imaging system using grid pattern images. Some experimental results of these calibrations is presented and discussed in detail ...

  • PDF

Total Tongue Reconstruction with Reinnervated Rectus Abdominis Musculocutaneous Flap (재신경화된 복직근 근피판을 이용한 혀 전체 재건술)

  • Kim, Cheol Hann;Tark, Min Sung
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.161-167
    • /
    • 2006
  • After total glossectomy, recovery of swallowing and speech function can greatly improve quality of life. The reconstructed tongue must be thick enough to contact with the hard palate for articulation. If the free flap is denervation, it may procede to have atrophy postoperatively. Therefor it is difficult to maintain the tongue volume for a long period of time. To resolve this problem, we have used a innervated rectus abdominis musculocutaneous flap and maintaining the volume through a neurorrhaphy. 7 patients underwent immediate reconstruction using a reinnervated rectus abdominis musculocutaneous free flap in which included intercostal nerve was anastomosed to the remaining hypoglossal nerve. The reinnervated rectus abdominis musculocutaneous free flap has provided good tongue contour with sufficient bulk and shown no obvious atrophy in all patients even though postoperative 9 months later. Considering swallowing and articulation, we concluded that reinnervated rectus abdominis musculocutaneous flap is a viable method after total glossectomy

ASPPMVSNet: A high-receptive-field multiview stereo network for dense three-dimensional reconstruction

  • Saleh Saeed;Sungjun Lee;Yongju Cho;Unsang Park
    • ETRI Journal
    • /
    • v.44 no.6
    • /
    • pp.1034-1046
    • /
    • 2022
  • The learning-based multiview stereo (MVS) methods for three-dimensional (3D) reconstruction generally use 3D volumes for depth inference. The quality of the reconstructed depth maps and the corresponding point clouds is directly influenced by the spatial resolution of the 3D volume. Consequently, these methods produce point clouds with sparse local regions because of the lack of the memory required to encode a high volume of information. Here, we apply the atrous spatial pyramid pooling (ASPP) module in MVS methods to obtain dense feature maps with multiscale, long-range, contextual information using high receptive fields. For a given 3D volume with the same spatial resolution as that in the MVS methods, the dense feature maps from the ASPP module encoded with superior information can produce dense point clouds without a high memory footprint. Furthermore, we propose a 3D loss for training the MVS networks, which improves the predicted depth values by 24.44%. The ASPP module provides state-of-the-art qualitative results by constructing relatively dense point clouds, which improves the DTU MVS dataset benchmarks by 2.25% compared with those achieved in the previous MVS methods.