• Title/Summary/Keyword: Volume of the building

Search Result 814, Processing Time 0.021 seconds

혼화재 다량치환 상태에서 FA 및 BS의 혼합비율에 따른 모르타르의 품질특성 (Performance Characteristics of Mortar with High Volume SCM Depending on Combinations of FA and BS)

  • 김민상;송원루;박성배;한동엽;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.126-127
    • /
    • 2016
  • In this research, the optimum combination of fly ash (FA) and blast furnace slag (BS) was deduced by analyzing the performance of high volume supplementary cementitious materials (SCMs) cement mortar depending on various combinations of cement, FA, and BS. As a result, increased workability was shown with increased the portion of FA, while air content, setting time, and compressive strength were decreased.

  • PDF

고로슬래그를 대량 활용한 비정질 금속 섬유보강 투수블럭의 시제품 성능평가 (Performance Evaluation of Trial Product of Amorphous Metallic Fiber Reinforced Porous Block Using High Volume Blast Furnace Slag Powder)

  • 김도빈;김영욱;김성진;김혜정;정수빈;최세진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.81-82
    • /
    • 2017
  • This study analyzed the compressive and flexural strength characteristics and the permeability coefficient of the trial product of amorphous metallic fiber reinforced porous block using high volume blast furnace slag powder.

  • PDF

구조물 건전도 평가를 위한 모르타르 내 공극 초음파 탐상 (Ultrasonic Testing of Voids inside Mortar for Structural Integrity Evaluation)

  • 조윤진;임홍철;김대유
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.91-92
    • /
    • 2016
  • Structural integrity of reinforced concrete structures including nuclear power plants needs to be evaluated on a regular basis. Deterioration inside the concrete structures can be represented by voids. In this study, the varied volume fraction of voids inside mortar specimens was studied as a parameter using ultrasonic testing equipments. Both direct and indirect measurement methods were employed. The results show that there is a clear distinction between the specimens with different void volume fractions.

  • PDF

Image analysis를 통한 다공성 시멘트 모르타르 복합체 내 공극량 산출 (An Analysis of the Air Void Volume Image Analysis of Porous Cement Mortar Composites)

  • 손다솜;이종구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.211-212
    • /
    • 2021
  • This study was conducted to derive quantitative air void volume calculation techniques in various complexes with porosity. Calculation of voids in a complex is an essential factor in improving mechanical properties, and quantitative measurement techniques are needed because the environment is not constant to apply the currently used ASTM criteria. Using the analysis technique obtained through 2D image analysis, it is believed that meaningful results can be derived through Micro CT analysis results and cross-check later.

  • PDF

Citic Tower Construction Key Technology

  • Xu, Lishan
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.185-192
    • /
    • 2019
  • Citic Tower is the first over-500 m-tall super highrise building in the world, located in the high seismic intensity area with paek ground acceleration over 0.2g in 475 years. This project is unique in its complexity, large volume, and challenging site conditions (zero site for construction). The traditional techniques can hardly meet safty, quality and schedule requirements of the construction. This article introduces the key construction technologies that are innovatively developed and applied in Citic Tower project construction, including intelligent super-high-rise building integrated construction platform system, independently developed by the CCTEB; Jump-Lift Elevator, which is the first of the kind with service height over 500 meters; combined temporary-and-permanent fire protection systems. The BIM technology is also applied in this project. Through technical innovation, and utilization of technologies, construction speed and safety had been greatly improved.

화학혼화제의 성분함유율 변화에 따른 콘크리트의 특성분석 (Analysis of concrete characteristic depending on chemical admixtures changing component content ratio)

  • 류현기
    • 한국건축시공학회지
    • /
    • 제9권2호
    • /
    • pp.85-91
    • /
    • 2009
  • W/C and unit volume, which significantly affect quality of concrete related to strength and durability, are regulated at below $185kg/m^3$ for regular concrete generally used in standard specification for constructions. The aim of this research is to develop chemical admixture and find out its potential use by identifying characteristics of admixtures added to soft concrete and hardening concrete, of which content ratio of component for each type of admixtures is subject to change in accordance with unit volume within KS' allowable range. Sodium gluconate, polyoxyethylene nonylphenyl ether, poly carboxylic copolymer in slump, which is characteristic of soft concrete, are deemed highly sensitive while there is no air entrainment except for $10\sim70%$ in WE, WR component content ratio and NP. In hardening concrete, strength in general showed higher action in compressive strength and tensile strength than in plain strength. Use of proper AE agent and AE water reducing agent at the same time is deemed to be used as chemical admixtures capable of manufacturing high-quality, high-quantity concrete.

3차원 포인트 클라우드 기반 Alpha Shape와 Voxel을 활용한 단일 식생 부피 산정 (Estimation of Single Vegetation Volume Using 3D Point Cloud-based Alpha Shape and Voxel)

  • 장은경;안명희
    • Ecology and Resilient Infrastructure
    • /
    • 제8권4호
    • /
    • pp.204-211
    • /
    • 2021
  • 본 연구에서는 3차원 지상 라이다 스캐너를 통해 수집되는 포인트 클라우드를 활용하여 식생의 정보를 수집하였으며, 수집된 데이터를 기반으로 객체를 재구현하여 물리적 형상을 분석하였다. 이를 위해 원시 데이터의 필터링 단계별 최적의 데이터를 구축하였으며, 구축된 데이터를 활용하여 실제 부피와 Alpha Shape 및 Voxel 기법을 활용한 부피 산정 결과를 산정한 후 각각 비교하였다. 분석 결과, Alpha Shape를 적용하여 부피를 산정한 경우 데이터 필터링과 관계없이 실제 부피보다 과다 산정되는 것으로 나타났다. 또한 Voxel 기법을 활용할 경우 8차 필터링 후 실제 부피와 가장 유사한 것으로 나타났으며, 이후 필터링이 진행될수록 실제 부피에 비해 과소 산정되는 것을 알 수 있었다. 따라서 포인트 클라우드를 활용하여 객체를 재구현 할 경우, 대상이 되는 객체의 복잡한 형상으로 인한 내부 공극을 고려해야 하며, 필터링 과정에서 최적의 데이터 구축을 위한 필터링 과정에 반드시 주의할 필요가 있다.

복합섬유를 혼입한 초고강도 콘크리트의 폭렬 특성 평가 (Evaluation on Spalling Properties of Ultra High Strength Concrete with Combined Fiber)

  • 손명학;김규용;민충식;이태규;구경모;윤용상
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.209-210
    • /
    • 2011
  • This study is aimed to draw a optimum combined fiber mix condition to improve spalling resistance and flowability of ultra high-strength concrete. As a result, W/B 12.5% concrete specimens were prevented spalling with PE0.05+ PP0.1, PE0.05+NY0.1 and W/B 12.5% concrete specimens were prevented spalling with all of combined organic fiber mix condition. But There is no significant influence of steel fiber under 5% volume ratios to prevent spalling. In the scope of this study, we suggest that condition of optimum volume ratio PE0.05+NY0.1 is to improve spalling resistance, flowability and residual compressive strength.

  • PDF

고로슬래그 미분말을 다량 치환한 모르타르의 압축강도 평가 (Evaluation of Compressive Strength of Mortar Replaced to High Volume Blast Furnace Slag)

  • 이보경;김규용;이세범;이병천;신경수;김홍섭
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.103-105
    • /
    • 2012
  • With blast-furnace slag is a by-product generated when pig iron is produced. It has been used as the concrete admixture due to high reactivity. However, It causes low strength development during early age. In order to make up for this drawback, in this study, we evaluated compressive strength of mortar replaced with high volume blast-furnace slag. Experimental results, Compressive strength of mortar based on blast-furnace slag is affected by cement type, substitution rate of blast-furnace slag and pH after mixing.

  • PDF

산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화 (Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator)

  • 김만구;권영진;정영림
    • 한국대기환경학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF