• Title/Summary/Keyword: Volume of oxygen consumption

Search Result 51, Processing Time 0.023 seconds

Development of Oxygen Combustion Burner for Industrial Gasification and Smelting Furnace (산업용 가스화 용융로를 위한 산소 버너의 개발)

  • Bae, Soo-Ho;Lee, Uen-Do;Shin, Hyun-Dong;Kim, Soung-Hyoun;Gu, Jae-Hoi;Yoo, Young-Don
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.170-178
    • /
    • 2005
  • Multi-hole type oxygen combustion burner was developed for industrial gasification and smelting furnace. We investigated characteristics of flame, radiation transfer, and soot emission in the convectional oxygen burner with respect to the feeding condition of fuel and oxygen. Regarding the results of the conventional burner, we designed new burners which have larger fuel consumption rate and radiation heat transfer. We changed the size and hole number and shape of the exit plane of the burner. In addition, the performance of the burner was tested with respect to the feeding condition of the fuel and air: Normal Diffusion flame(NDF) and Inverse Diffusion Flame(IDF). We investigated the flame configuration, radiation heat transfer, and soot formation by using a CCD camera, heat flux meter, and Laser Induced Incadescence(LII), respectively. The stable operating condition was obtained by the flame configuration and the flame of the burner which has dented exit plane was more stable in whole operating conditions. The characteristics of radiative heat transfer were sensitive to the feeding condition of reactants and the flame of 75% primary oxygen and 25% secondary oxygen of the IDF case shows maximum radiation heat transfer. The soot volume fraction of the flame was measured in the axial direction of the flame and the amount of soot volume fraction is proportion to the radiation heat transfer. As a result, we can get the optimal operating condition of the newly designed burner which enhances the characteristics of flame stabilization and radiation heat transfer.

  • PDF

Mass Production of Mammalian Cells under Chemostat Cultivation (동물세포의 연속 대량생산에 관한 연구)

  • 이현용;강재구;박형환
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.3
    • /
    • pp.173-177
    • /
    • 1989
  • Cell density was gradually decreased as the dilution rate was increased under chemostat cultivation of HeLa cells. Maxium cell density was maintained at the dilution rate of 0.020 (1/h) which was far less than the wash-out rate of 0.050 (1/h), Maxium cell productivity of 2 (mL of cells/L/h)was obtained at the dilution rate of 0.030 (1/h) by showing the culture also required maintenance period at low dilution rates, whose result meant the deviation of continuous culture theroy. Methods of indirectly measuring cell density have been introduced to represent mammalian cell growth, which are packed cell volume and oxygen uptake rate, and these values showed good linear relationship with actual cell density by having correlation factor of 0.90. Theoretical maximum oxygen yield, $Y_{O2}^{max}$ and maintenance oxygen consumption rate, m$_{O2}$, were estimated as 4.1$\times$10$^5$ (cells/mmole $O_2$) and 10.71$\times$10$^{-9}$ (mmole $O_2$/cells/h) by employing oxygen yield model.

  • PDF

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility (10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구)

  • Ryu, Sang-Hoon;Yoo, Yong-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.58-65
    • /
    • 2010
  • The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.

A study on an intermittent aeration membrane bioreactor system using ammonia sensor to decrease energy consumption and sludge concentration by tubular membrane (암모니아 센서를 이용한 간헐폭기 Membrane bioreactor공정에서의 전력비 저감과 관형막을 이용한 슬러지 농축에 관한 연구)

  • Kang, Heeseok;Lee, Euijong;Kim, Hyungsoo;Jang, Am
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.161-170
    • /
    • 2014
  • It is essential to decrease energy consumption and excess sludge to economically operate sewage treatment plant. This becomes more important along with a ban on sea dumping and exhaustion of resource. Therefore, many researchers have been study on energy consumption reduction and strategies for minimization of excess sludge production from the activated sludge process. The aeration cost account for a high proportion of maintenance cost because sufficient air is necessary to keep nitrifying bacteria activity of which the oxygen affinity is inferior to that of heterotrophic bacteria. Also, additional costs are incurred to stabilize excess sludge and decrease the volume of sludge. There were anoxic, aerobic, membrane, deairation and concentration zone in this MBR process. Continuous aeration was provided to prevent membrane fouling in membrane zone and intermittent aeration was provided in aerobic zone through ammonia sensor. So, there was the minimum oxygen to remove $NH_4-N$ below limited quantity that could be eliminated in membrane zone. As the result of this control, energy consumption of aeration system declined by between 10.4 % and 19.1 %. Besides, we could maintain high MLSS concentration in concentration zone and this induced the microorganisms to be in starved condition. Consequentially, the amount of excess sludge decrease by about 15 %.

Experimental Study of the Effects of Gyumsuyukgunjun on the Pulmonary Injury Caused by Exposure of Cigarette Smoke in Rats (김수육군전(金水六君煎)이 흡연(吸煙)한 백서(白鼠)의 폐손상(肺損傷)에 미치는 영향(影響))

  • Kam, Chul-Woo;Park, Dong-Il
    • Korean Journal of Oriental Medicine
    • /
    • v.3 no.1
    • /
    • pp.261-278
    • /
    • 1997
  • This experiment was performed in order to study the clinical effects of Gyumsuyukgunjun on the pulmonary injury caused by exposure of cigarette smoke in rats. Therefore, a writer reports on present experimental results having significant effects on the level of oxygen consumption, the lungs volume, the leukocyte, the hemoglobin level, and the $PaO_2$, $PaCO_2$ after administration of Gyumsuyukgunjun in order to study the clinical effects of Gyumsuyukgunjun on the pulmonary injury caused by exposure of cigarette smoke in rats. The results were obtained as follows: 1. In comparison with control group, The group of Gyumsuyukgunjun administration was revealed significant effects(P<0.005) of increase on the level of oxygen consumption. 2. In comparison with control group, The group of Gyumsuyukgunjun administration was revealed significant effects(P<0.005) of decrease on the lungs volume. 3. In comparison with control group, The group of Gyumsuyukgunjun administration was revealed significant effects(P<0.05) of decrease on the leukocyte counts. 4. In comparison with control group, The group of Gyumsuyukgunjun administration was revealed significant effects(P<0.05) of decrease on the hemoglobin level. 5. In comparison with control group, The group of Gyumsuyukgunjun administration was revealed significant effects(P<0.01) of increase on the $PaO_2$ level only of $PaO_2$, $PaCO_2$ level. It was concluded from the above results that Gyumsuyukgunjun has a significant effects on the pulmonary injury caused by cigarette smoke.

  • PDF

Regeneration of Exhausted Activated Carbon by a Countercurrent Oxygen Reaction

  • 류건상;김태동;김유항
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.12
    • /
    • pp.1447-1450
    • /
    • 1999
  • Countercurrent oxygen reaction (COR) was developed and evaluated for regeneration of exhausted activated carbon. Whether the regeneration technique is feasible or not is affected strongly by gradual loss and physical changes of activated carbon, energy consumption, and effective removal of adsorbed materials during the process. Various parameters such as reaction temperature, the loss of activated carbon, surface area, pore volume, surface structure, adsorptive property, etc. were examined to determine the effectiveness of COR. The results of these tests showed that the parameters were strongly dependent on oxidant flow rate, and suggest that the newly developed COR is comparable and, in some ways, possibly superior to conventional regeneration techniques because the overall process runs in a single step and is less energy intensive, and also because the adsorptive capacity of exhausted activated carbon was completely recovered.

The Effects of Pulmonary Resectional Surgery for Cavitary Tuberculosis on Ventilation and Arterial Respiratory Gases (폐결핵환자에서 폐절제술이 폐기능에 미치는 영향에 관한 연구)

  • 이현우
    • Journal of Chest Surgery
    • /
    • v.6 no.1
    • /
    • pp.7-14
    • /
    • 1973
  • Ventilatory functions and arterial respiratory gases were studied in 24 patients who underwent resectional surgery for pulmonary tuberculosis. Postoperative measurements were made 24 hours, 72 hours and 7 days after surgery and the results were compared to preoperative values. Twenty-four hours postoperatively, there occurred striking increase in respiratory rate, minute ventilation, dead space ventilation and dead space tidal volume ratio, and the increase in minute ventilation was caused primarily by the increase in respiratory rate. However, alveolar ventilation, oxygen consumption, carbon dioxide elimination and respiratory quotient showed no significant postoperative changes although two of the last values showed slight decreases 24 hours after surgery. The lowest arterial oxygen saturation level was obtained 24 hours postoperatively followed by gradual rises but not to the preoperative levels until 7 days after surgery. A decreased arterial carbon dioxide tension with elevated pit was noted 24 hours after surgery, which returned to the preoperative level on the following measurement.

  • PDF

Relationship between Total Body Fat and S/V Ratio and Body Cooling for Two Hours at $15^{\circ}C$ (한냉에 노출된 인체의 냉각과 총지방량 및 S/V 비율 사이의 관계)

  • Chung, Kwan-Ogg;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.19-28
    • /
    • 1969
  • Skin temperatures on 10 sites and rectal temperature at every 10 minutes, oxygen consumption at every 20 minutes were measured on 18 male subjects (ages between 14 and 47 years) after exposure to cold air at $15^{\circ}C$ for two hours in a climatic room. Total body fat measured by means of a skinfold method and ratio of body surface area (S) to body volume (V), S/V, were utilized as basis of observations. Surface area was calculated after DuBois equation and body volume was calculated by our original formula. In influencing on the heat loss from the body core to the cold environment, % fat showed inverse relations, whereas, S/V ratio showed direct relations. Thus these two factors acted antagonistically on the body heat loss. Local skin temperatures showed negative correlations with skinfold thickness on the same site, nemaly, on chest, r=-.567; on back, r=-.507; and on upper arm, r=-.353. The other 7 skin sites showed low correlations with % fat. Minimum mean weighted skin temperature (MWST) showed a negative correlation (r=-.443) with % fat, and showed no correlation with S/V ratio. Oxygen consumption in the cold air at $15^{\circ}C$ increased from the first measurement at 20 minutes after exposure and maintained the same increasing trend up to 120 minutes. ${\Delta}T_R$ was greater in tile lean subjects who showed a greater % change in oxygen consumption. The antagonistic actions of % fat and S/V ratio on the heat loss were manifested by observations as follows: minimum rectal temperature was higher In fat subjects (r=.600) and lower in subjects with a greater S/V ratio (=-.582), ${\Delta}T_R$ was smaller in fat subjects (r=-.738) and greater in subjects with a greater S/V ratio (r=.618). Temperature difference between body core and skin surface (minimum rectal temperature minus minimum MWST) showed a positive correlation with % fat (r=.600) and a negative correlation with S/V ratio (r=-.881). Decrease in the mean body temperature and heat debt, respectively, showed negative correlations with % fat and positive correlations with S/V ratio.

  • PDF

Studies on the Physical Fitness of the Middle and High School Boys (성장기 한국인 남녀 기초체력 향상에 관한 연구 (남자 중.고등학생을 대상으로 하여))

  • Chae, E-Up;Kim, Kyu-Soo;Choo, Young-Eun;Kim, Chong-Suck;Woo, Won-Hyung;Chung, Pock-Tuck
    • The Korean Journal of Physiology
    • /
    • v.4 no.2
    • /
    • pp.5-17
    • /
    • 1970
  • The effects of Physical exercise, gymnastics and sports on the cardiopulmonary function were studied in the middle and high school toys. The subjects were divided into 4 groups; non-training group and training group in both middle school and high school boys. In the above groups, pulmonary function studies were performed, and blood pressure and the heart rate were also checked to evaluate physical fitness during and immediately after running exercise on the tread-mill, with the speed of 5 MPH and elevation of 9% and 11.25%. The types of sports in the training group were base ball, body building, Taekwondo (Korean style boxing) and hand ball. The results obtained were as followings: 1) In the training group, cardiopulmonary function showed some tendency of the increase comparing to the non-training group. 2) The increase in cardiopulmonary function was observed according to the age became older, but the clear changes on cardiopulmonary function was not observed as the difference of the group between the training and the non-training. 3) The expiratory volume was decreased as the increase of age except 17 years of age for the value of the per kg body weight. 4) In the non-training group, the mean value of oxygen consumption under maximum work load was increased, while those in the training group was decreased. But it may be noted that oxygen consumption for the expiratory volume was increased in the training group, and that the oxygen cost in the training group was .higher than that of the non-training group. 5) The pulse pressure of the high school group during and immediately after running exercise was observed in the higher value comparing with that of the middle school group It was suggested that the changes of the pulse pressure was owing to the method of determination and that to the decrease of diastolic pressure caused by the decrease of peripheral vascular resistance up to critical closing pressure. 6) Any differences of the changes in the heart rate between the training group and non-training group was not observed during and immediately after running exercise. 7) The relative value of the expiratory volume to the heart rate was decreased in the elder age group.

  • PDF

Impact of Pulmonary Arterial Elastance on Right Ventricular Mechanics and Exercise Capacity in Repaired Tetralogy of Fallot

  • Soo-Jin Kim;Mei Hua Li;Chung Il Noh;Seong-Ho Kim;Chang-Ha Lee;Ja-Kyoung Yoon
    • Korean Circulation Journal
    • /
    • v.53 no.6
    • /
    • pp.406-417
    • /
    • 2023
  • Background and Objectives: Pathophysiological changes of right ventricle (RV) after repair of tetralogy of Fallot (TOF) are coupled with a highly compliant low-pressure pulmonary artery (PA) system. This study aimed to determine whether pulmonary vascular function was associated with RV parameters and exercise capacity, and its impact on RV remodeling after pulmonary valve replacement. Methods: In a total of 48 patients over 18 years of age with repaired TOF, pulmonary arterial elastance (Ea), RV volume data, and RV-PA coupling ratio were calculated and analyzed in relation to exercise capacity. Results: Patients with a low Ea showed a more severe pulmonary regurgitation volume index, greater RV end-diastolic volume index, and greater effective RV stroke volume (p=0.039, p=0.013, and p=0.011, respectively). Patients with a high Ea had lower exercise capacity than those with a low Ea (peak oxygen consumption [peak VO2] rate: 25.8±7.7 vs. 34.3±5.5 mL/kg/min, respectively, p=0.003), while peak VO2 was inversely correlated with Ea and mean PA pressure (p=0.004 and p=0.004, respectively). In the univariate analysis, a higher preoperative RV end-diastolic volume index and RV end-systolic volume index, left ventricular end-systolic volume index, and higher RV-PA coupling ratio were risk factors for suboptimal outcomes. Preoperative RV volume and RV-PA coupling ratio reflecting the adaptive PA system response are important factors in optimal postoperative results. Conclusions: We found that PA vascular dysfunction, presenting as elevated Ea in TOF, may contribute to exercise intolerance. However, Ea was inversely correlated with pulmonary regurgitation (PR) severity, which may prevent PR, RV dilatation, and left ventricular dilatation in the absence of significant pulmonary stenosis.