• Title/Summary/Keyword: Volume of interest

Search Result 481, Processing Time 0.023 seconds

Query System for Analysis of Medical Tomography Images (의료 단층 영상의 분석을 위한 쿼리 시스템)

  • Kim, Tae-Woo;Cho, Tae-Kyung;Park, Byoung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.1
    • /
    • pp.38-43
    • /
    • 2004
  • We designed and implemented a medical image query system, including a relational database and DBMS (database management system), which can visualize image data and can achieve spatial, attribute, and mixed queries. Image data used in querying can be visualized in slice, MPR(multi-planner reformat), volume rendering, and overlapping on the query system. To reduce spatial cost and processing time in the system. brain images are spatially clustered, by an adaptive Hilbert curve filling, encoded, and stored to its database without loss for spatial query. Because the query is often applied to small image regions of interest(ROI's), the technique provides higher compression rate and less processing time in the cases.

  • PDF

Implementation of Occupant Density and Walking Pattern Measurement for Emergency Evacuation and Safety in High-Rise Multi-Purpose Facilities

  • Lee, Myung Sik
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.409-415
    • /
    • 2018
  • Recently, many countries around the world began to show interest in safety against terrorism, fire, and natural disasters. This study aimed to propose a quantitative measurement system for emergency evacuation and safety for various kinds of terrorism and fire within high-rise multi-purpose facilities, which can measure the pedestrians' ordinary walking patterns in the concourse with the highest pedestrian volume out of all the spaces within multi-story buildings, predict pedestrians' evacuation walking lines when a sudden disaster breaks out, and analyze the gait coefficient, occupant density, and evacuation behavior time.

Development of a Test Stand for Measuring Ink Jetting Performance (잉크젯 토출 특성 평가 장치 개발)

  • Kwon, Kye-Si
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.45-50
    • /
    • 2008
  • An ink jetting measurement system has been developed such that the velocity as well as the volume of ink droplets can be measured. In order to measure the ink droplet, a strobe LED light was synchronized to the droplet firing signal in order to obtain frozen droplet images. Then, a LabVIEW based software was developed for the analysis of the droplet image. For the efficient droplet analysis, a user generated rectangular shaped ROI (Region of Interest) was used. By using ROI, the ink droplet image can be easily isolated from the other structures such as printhead and the processing area can be minimized.

A Review of Electrochemical Hydrogen Compressor Technology (전기화학적 수소 압축기 기술)

  • KIM, SANG-KYUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.6
    • /
    • pp.578-586
    • /
    • 2020
  • There is growing interest worldwide in a hydrogen economy that uses hydrogen as an energy medium instead of hydrocarbon-based fossil fuels as a way to combat climate change. Since hydrogen has a very low energy density per unit volume at room temperature, hydrogen must be compressed and stored in order to use as an energy carrier. There are mechanical and non-mechanical methods for compressing hydrogen. The mechanical method has disadvantages such as high energy consumption, durability problems of moving parts, hydrogen contamination by lubricants, and noise. Among the non-mechanical compression methods, electrochemical compression consumes less energy and can compress hydrogen with high purity. In this paper, research trends are reviewed, focusing on research papers on electrochemical hydrogen compression technology, and future research directions are suggested.

Difference between Korean and Occidental Group-specific Label-based Probabilistic Brain Atlas

  • Gu, Bang-Bon;Lee, Jong-Min
    • The Magazine of the IEIE
    • /
    • v.36 no.11
    • /
    • pp.66-82
    • /
    • 2009
  • Probabilistic atlases for the human brain structure are more suitable than single brain atlases for representing population anatomy. In this study, we hypothesized the group-specific probabilistic atlas for accurate characteristic feature coding. Our proposed method for a new group comparison study, using a subpopulation specific probabilistic atlas, was based on this hypothesis. A knowledge-based automatic labeling technique using nonlinear registration was applied to encode group-specific regional probabilistic information. Direct atlas-based comparison using volume counting above the probability threshold, distance measurement and correlation analysis were performed based on the probabilistic atlas. Here, we applied this method for comparison between Korean and occidental groups. The results showed that this method could provide simple but intuitive regions of interest-based group analysis for the entire cortex area.

  • PDF

Myelin Content in Mild Traumatic Brain Injury Patients with Post-Concussion Syndrome: Quantitative Assessment with a Multidynamic Multiecho Sequence

  • Roh-Eul Yoo;Seung Hong Choi;Sung-Won Youn;Moonjung Hwang;Eunkyung Kim;Byung-Mo Oh;Ji Ye Lee;Inpyeong Hwang;Koung Mi Kang;Tae Jin Yun;Ji-hoon Kim;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.226-236
    • /
    • 2022
  • Objective: This study aimed to explore the myelin volume change in patients with mild traumatic brain injury (mTBI) with post-concussion syndrome (PCS) using a multidynamic multiecho (MDME) sequence and automatic whole-brain segmentation. Materials and Methods: Forty-one consecutive mTBI patients with PCS and 29 controls, who had undergone MRI including the MDME sequence between October 2016 and April 2018, were included. Myelin volume fraction (MVF) maps were derived from the MDME sequence. After three dimensional T1-based brain segmentation, the average MVF was analyzed at the bilateral cerebral white matter (WM), bilateral cerebral gray matter (GM), corpus callosum, and brainstem. The Mann-Whitney U-test was performed to compare MVF and myelin volume between patients with mTBI and controls. Myelin volume was correlated with neuropsychological test scores using the Spearman rank correlation test. Results: The average MVF at the bilateral cerebral WM was lower in mTBI patients with PCS (median [interquartile range], 25.2% [22.6%-26.4%]) than that in controls (26.8% [25.6%-27.8%]) (p = 0.004). The region-of-interest myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (1.87 cm3 [1.70-2.05 cm3] vs. 2.21 cm3 [1.86-3.46 cm3]; p = 0.003) and brainstem (9.98 cm3 [9.45-11.00 cm3] vs. 11.05 cm3 [10.10-11.53 cm3]; p = 0.015). The total myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (0.45 cm3 [0.39-0.48 cm3] vs. 0.48 cm3 [0.45-0.54 cm3]; p = 0.004) and brainstem (1.45 cm3 [1.28-1.59 cm3] vs. 1.54 cm3 [1.42-1.67 cm3]; p = 0.042). No significant correlation was observed between myelin volume parameters and neuropsychological test scores, except for the total myelin volume at the bilateral cerebral WM and verbal learning test (delayed recall) (r = 0.425; p = 0.048). Conclusion: MVF quantified from the MDME sequence was decreased at the bilateral cerebral WM in mTBI patients with PCS. The total myelin volumes at the corpus callosum and brainstem were decreased in mTBI patients with PCS due to atrophic changes.

Image Evaluation Via $SUV_{LBM}$ for Normal Regions of VOI by Using Whole Body Images Obtained from PET/MRI and PET/CT (F-18 FDG PET/MRI와 PET/CT 전신 영상에서 VOI를 이용한 정상부위의 $SUV_{LBM}$-최대치에 의한 영상평가)

  • Park, Jeong-Kyu;Kim, Sung-Kyu;Cho, Ihn-Ho;Kong, Eun-Jung;Park, Meyong-Hwan
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.68-75
    • /
    • 2013
  • The purpose of this research is to compare and analyze $SUV_{LBM}$-maximum of normal regions using VOI (the volume of interest) in order to enhance the diagnostic level in whole body images of PET/CT and PET/MRI for 26 health check-up participants. In particular, we try to set up $SUV_{LBM}$-maximum data that can be used in synchronous evaluation for PET/CT and PET/MRI without contrast media. The evaluation of $SUV_{LBM}$-maximum for normal regions of whole body PET/CT and whole body PET/MRI shows that the image of PET/MRI differs very significantly from the reference image of PET/CT (p<0.0001). However, they exhibit high correlations in view of statistics (R>0.8). From this research, we suggest that the decision in the evaluation of $SUV_{LBM}$-maximum for PET/MRI should be made with the reduction of about 26.3%, while one should decide with the reduction of about 29.3% when the contrast media is used. It is helpful to interpret all image of PET/CT and PET/MRI using $SUV_{LBM}$-maximum for convenience and efficiency.

Estimates on the Long-term Landform Changes Near Sinduri Beaches (신두리 해빈 장기해안지형변화 탐지 및 추정)

  • Yun, Konghyun;Lee, Chang Kyung;Kim, Gyung Soo
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1315-1328
    • /
    • 2022
  • Sinduri beach is a typical sedimentary landform that forms sand dunes due to the influence of the northwest wind in winter. Due to the its large scale and well-developed nature, it has been recognized for conservation value and is currently designated as Natural Monument No. 431, and continuous monitoring is required in terms of the preservation of topographical values. In this study, aerial images, drone images, and drone-based LiDAR data during 36 years were used for long-term topographical change observation of the Sinduri coastal sand dunes located in Taean-gun, Chungcheongnam-do. To implement this, the amount of change in elevation and volume for each period was calculated by applying the difference of Digital Elevation Model (DEM) based on raster calculation using the numerical elevation model generated from the raw data. Also, the amount of change in volume based on probability was calculated using the error propagation law for the intrinsic error of each data source. As a result, it can be seen that from 1986 to 2022, deposition of 35,119 m3 occurred in region of interest A (area: 17,960 m2) and 54,954 m3 of deposition occurred in region of interest B (area: 17,686 m2).

Dose Reduction and Image Quality Assessment of the CareDose 4D Technique on Abdomen Liver Computed Tomography (복부 간 CT 검사에서 CareDose 4D 사용에 따른 선량 감소 및 화질 평가)

  • Seok, Jong-Min;Jeon, Woo-Jin;Park, Young-Joon;Lee, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.109-115
    • /
    • 2017
  • The purpose of this study was to evaluate the clinical efficacy of 128 MDCT (multi-detector computed tomography) for reducing the CareDose 4D dose and comparing the image quality with the fixed tube current technique. For this purpose, we conducted the phantom and clinical studies to evaluate the exposure dose and image of the subject before and after applying the CareDose 4D system in abdominal examination using 128 MDCT. In the phantom study, ROI (Region of interest) was located at the center, 3, 6, 9, 12 o'clock, into two groups: group A without CareDose 4D and Group B applied were measured. In the clinical study, ROI was located at the liver 8 segments, divided into two groups too. The measured items were CT number, noise, and dose length product (DLP) dose. The result of CTDIvol (CT Dose Index volume) measurements in phantom and clinical studies were lower than those before CareDose 4D application, and dose and effective dose were also measured lower (p<.05). There was no difference in CT number before and after application (p>.05). In conclusion, using CareDose 4D, we can obtain optimal image information without deteriorating image quality while reducing patient dose.

Automatic Meniscus Segmentation from Knee MR Images using Multi-atlas-based Locally-weighted Voting and Patch-based Edge Feature Classification (무릎 MR 영상에서 다중 아틀라스 기반 지역적 가중 투표 및 패치 기반 윤곽선 특징 분류를 통한 반월상 연골 자동 분할)

  • Kim, SoonBeen;Kim, Hyeonjin;Hong, Helen;Wang, Joon Ho
    • Journal of the Korea Computer Graphics Society
    • /
    • v.24 no.4
    • /
    • pp.29-38
    • /
    • 2018
  • In this paper, we propose an automatic segmentation method of meniscus in knee MR images by automatic meniscus localization, multi-atlas-based locally-weighted voting, and patch-based edge feature classification. First, after segmenting the bone and knee articular cartilage, the volume of interest of the meniscus is automatically localized. Second, the meniscus is segmented by multi-atlas-based locally-weighted voting taking into account the weights of shape and intensity distribution in the volume of interest of the meniscus. Finally, to remove leakage to the collateral ligaments with similar intensity, meniscus is refined using patch-based edge feature classification considering shape and distance weights. Dice similarity coefficient between proposed method and manual segmentation were 80.13% of medial meniscus and 80.81 % for lateral meniscus, and showed better results of 7.25% for medial meniscus and 1.31% for lateral meniscus compared to the multi-atlas-based locally-weighted voting.