• Title/Summary/Keyword: Volume expansion rate

Search Result 146, Processing Time 0.025 seconds

The Effect of Seasoning on the Intestinal Absorption -Absorption by Passive Transport and the Effect of Red Pepper- (조미료가 창자 운동과 흡수기능에 미치는 영향 -소장의 피동적 흡수에 대한 고추의 영향-)

  • Shin, Dong-Hoon;Kim, Joong-Soo;Koh, Jae-Pyong;Ahn, Seung-Woon
    • The Korean Journal of Physiology
    • /
    • v.7 no.1
    • /
    • pp.23-31
    • /
    • 1973
  • Numerous factors concern with the absorption of substances through the membrane of the gastrointestinal tract. To simplify the experimental condition, present work has been restricted to observe the disappearance rate of substance from the intestinal loop which was made in the jejunum, 70 cm apart from the pylorus of the adult rabbit. The purpose of the study is to clarify the absorption of urea through the jejunal wall is solely attributable to the concentration difference between the luminal fluid and plasma, and to observe the effect of adding red pepper upon the rate of absorption. The rabbits were anesthetized with nembutal, 35mg/kg I.V. Jejunal loop was made by ligating at 2 spots, 70 cm and 80cm apart from the pylorus. After rinsing with normal saline solution through the polyethylene tubing inserted from the end of the loop, 8 ml of test solution was placed through the same tubing. The test solution contained 200 mg% of urea and 150mg% of polyethylene glycol(M.W. 4,000) in normal saline solution. Right after placing the test solution the first specimen was taken through the tubing, and successive samplings were performed at 5, 10, 20, and 30 minutes. Logarithm of the difference of urea concentration between the luminal fluid and plasma was plotted against time elapsed after the onset of the experiment. If straight line is revealed, it would verify the nature of transport mechanism as diffusion, obeying the Fick's principle. The concentration of polyethylene glycol (PEG) was also measured in order to examine the change in the volume. PEG was used as the marker substance because it is not absorbable in the intestinal tract. Consequently the concentration of PEG relates inversely to the volume of the loop. Instantaneous concentration of urea in the loop times the volume will give the amount of urea remaining in the luminal fluid. The change in the amount of any substance is directly relate to the volume of the compartment and differs from the change in the concentration which is independent of the volume. After completion of the experiment without red pepper, it was added in the test solution and was centrifuged after thorough mixing. Supernatant of the mixture was placed in the loop and similar sampling were performed with the same time intervals that of previous run in order to observe the effects of the red pepper on the passive transport of the water soluble small substance, urea. The results obtained were as follows: 1. Logarithm of the concentration difference of urea between the luminal fluid and plasma was diminished exponentially as time elapsed. The decay constant in the experiment without red pepper was 0.0563/min. By adding red pepper in the test solution as much as the concentration rose to 4,000 mg% and 8,000 mg%, the decay constants were lowered to 0.0493/min and to 0.0506/min, respectively. The time interval by which the concentration difference dropped to one half of the initial value was prolonged. Without red pepper the half concentration time was 13.30 minutes, and by adding extract of red pepper, 15.31 minutes and 15.71 minutes were revealed. 2. The profile of the diminishing rate of tile amount of urea was quite different from that of the concentration because of the change in the volume of the loop during the observed period. 3. By adding the extract of red pepper, it slowed down the rate of absorption of urea in the intestinal loop, suggesting an increase in the diffusional barrier. 4. Larger dosage of red pepper brought an increase in the secretion of intestinal fluid with concomitant expansion of the luminal volume, and the retardation of the absorption of urea was noticed. This effect was largely dependent on the sensitivity of the individual animal to the red pepper, extract. The amount of urea remained after 10 minutes interval was 55.5% of the initial amount in the experiment without red pepper. On the other hand it was not consistent after administration of red pepper, showing 50.6% and 66.5% of the initial figures by adding 400 mg and 800 mg of red pepper in the test solution, respectively. It was postulated that symptom of diarrhea often encountered by taking a hot (red pepper) food might be attributable to the increase of secretion and the retardation of absorption in the intestinal tract.

  • PDF

Discussion on the Current Mortar-bar Method (ASTM 0227-90) by Experimental Study (실험적 연구에 의한 현행 모르타르봉 시험법(ASTM C227-90)의 검토)

  • 정지곤;이동영;유신애;황형중
    • The Journal of Engineering Geology
    • /
    • v.6 no.3
    • /
    • pp.155-163
    • /
    • 1996
  • The current ASTM C227-90 is a prescription on the mortar-bar method. This recornrnends that mortar-bars should be made using a mixing ratio by weight of 675 grams aggregate to 300 grams cement, and their initial lengths should be measured in $24{\pm}2$ hours. This method emphasizes that the prepare sample mortar-bars and calculate expansion rates of them. This method requires constant G values (effective gauge lengths) of denominator in the calculation formula, which are fixed either at 10 inches or 250mm. This study, based on experimental approaches, reexamines the suggestions made by those two prescriptions above and important results are summarized in the following. 1. Not only alkali-aggregate reaction but also interaction of interstitial and gel water are responsible for expansion of mortar-bars. This requires partial modification of the current ASTM C227-90. 2. A mixing ratio by volume rather than by weight of aggregate to cement is recommendable for measuring the amount of expansion resulting from alkali-aggregate reaction and from interstitial water. 3. The method of when to measure initial lengths and how to calculate expansion rate suggested by ASThI C227-90 and Cl90-93a should partly be modified for more accurate results.

  • PDF

A Numerical Study Of Flow Control Valve to Flow Characteristics by Pressure Difference for Hydrogen Station (수소충전소용 유량제어 밸브의 차압에 따른 유동특성에 대한 수치해석적 연구)

  • Nam, Chung-Woo;Kim, Rak-Min;Kim, Hyun-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.2
    • /
    • pp.28-33
    • /
    • 2021
  • With the recent growing interest in eco-friendly cars, as interest in eco-friendly cars increases, interest and purchase of hydrogen fuel cell vehicles that do not emit pollutants are increasing. Recently, the government is supporting the expansion of hydrogen charging station and localization of core parts according to the government's hydrogen energy dissemination policy. In this study, the flow characteristics of the hydrogen flow control valve were investigated. As the differential pressure increases, the mass flow rate and flow coefficient tend to be different from the volume flow rate. And it was confirmed that it affects the hydrogen temperature due to the nozzle effect in the bottleneck section, and the change in density affects the mass flow rate.

An Analysis on the Effect of Japanese Monetary Policy in 21C (21c 일본 통화정책 효과에 대한 분석)

  • Yoon, Hyung-Mo
    • International Area Studies Review
    • /
    • v.20 no.1
    • /
    • pp.105-125
    • /
    • 2016
  • The expansionary monetary policy was practiced after 2001 in Japan to treat the deflation spiral, and reduced only the nominal interest rates and domestic household demand. One of the most serious factors for this failure was the change of private sector's expectancy. This paper has studied the effect of Japanese monetary policy in 21c., with empirical research based on a renewed macroeconomic model and the VAR. The empirical analysis shows that the effect of monetary policy on the national income during 2001.01-2015.03 is weaker than that of 1985.01-1994.04. Money volume has a diminutive effect on the growth of GDP within a short term after 2001. The change in the expectations of the private sectors might have been the cause of ineffectiveness of the expansive monetary policy. Economic agents learned from the past Japanese financial crisis that an expansive monetary policy increased the inflation rate and caused the 'bubbles to burst' afterwards. The VAR analysis says that the effectiveness of monetary policy on the economic depression declined over the past 20 years and the expansion of money volume has no influence on exchange rate and net export. This means that the expansive monetary policy lost its effect on net export and national income steadily. Monetary policy makers have to recognize this fact, and to consider another anti-cycle political instrument, i.e. the fiscal policy with government debt.

Analytical model of corrosion-induced cracking of concrete considering the stiffness of reinforcement

  • Bhargava, Kapilesh;Ghosh, A.K.;Mori, Yasuhiro;Ramanujam, S.
    • Structural Engineering and Mechanics
    • /
    • v.16 no.6
    • /
    • pp.749-769
    • /
    • 2003
  • The structural deterioration of concrete structures due to reinforcement corrosion is a major worldwide problem. Service life of the age-degraded concrete structures is governed by the protective action provided by the cover concrete against the susceptibility of the reinforcement to the corrosive environment. The corrosion of steel would result in the various corrosion products, which depending on the level of the oxidation may have much greater volume than the original iron that gets consumed by the process of corrosion. This volume expansion would be responsible for exerting the expansive radial pressure at the steel-concrete interface resulting in the development of hoop tensile stresses in the surrounding cover concrete. Once the maximum hoop tensile stress exceeds the tensile strength of the concrete, cracking of cover concrete would take place. The cracking begins at the steel-concrete interface and propagates outwards and eventually resulting in the through cracking of the cover concrete. The cover cracking would indicate the loss of the service life for the corrosion-affected structures. In the present paper, analytical models have been developed considering the residual strength of the cracked concrete and the stiffness provided by the combination of the reinforcement and expansive corrosion products. The problem is modeled as a boundary value problem and the governing equations are expressed in terms of the radial displacement. The analytical solutions are presented considering a simple 2-zone model for the cover concrete viz. cracked or uncracked. A sensitivity analysis has also been carried out to show the influence of the various parameters of the proposed models. The time to cover cracking is found to be function of initial material properties of the cover concrete and reinforcement plus corrosion products combine, type of rust products, rate of corrosion and the residual strength of the cover concrete. The calculated cracking times are correlated against the published experimental and analytical reference data.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Investigation of Reinforced Distribution in Fabrication Process of Metal Matrix Composites by Combined Stirring Process (복합교반법에 의한 금속복합재료의 제조공정에 따른 강화재의 분산성 검토)

  • 이동건;강충길
    • Composites Research
    • /
    • v.14 no.5
    • /
    • pp.1-11
    • /
    • 2001
  • The particulates reinforced metal matrix composites(PMMC) have a number of interesting mechanical properties. including high strength and good resistance to wear at high temperature and low thermal expansion. The equipment structure to obtain the homogeneous distribution in composites are proposed for the continuous pouring of reinforcement at the desired temperature. The particulates reinforced metal matrix composites(A357/SiCp) were fabricated by the process of the combined stirring method with the various fabrication process. The combined stirring method to niform distribution of particle is consisted of two stirring force both electro-magnetic stirring generated from induction heating and mechanical stirring with graphite stirrer. PMMC billets were fabricated with the volume fractions ranged from 0% to 20% and particle sizes ranged from 14${\mu}{\textrm}{m}$ to 25${\mu}{\textrm}{m}$. It is important to cont the size of primary $\alpha$-Al solid particles because it could become the cause of the particle pushing or capture phenomena from the fact that secondary dendrite arm spacing size depends on the cooling rate during the solidification in hypoeutectic Al-Si alloy. Therefore, the effect of primary $\alpha$-Al on the reinforcement distribution in matrix alloys has been investigated. The microstructure of PMMC fabracated with various volume fractions(0%, 10%, and 20%) and particle size were observed.

  • PDF

Isolation of an Oocyte Stimulatory Peptide from the Ovarian Follicular Fluid of Water Buffalo (Bubalus bubalis)

  • Gupta, P.S.P.;Ravindra, J.P.;Nandi, S.;Raghu, H.M.;Ramesha, K.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.11
    • /
    • pp.1557-1563
    • /
    • 2005
  • Ovarian follicular fluid contains both stimulatory and inhibitory agents that influence the growth and maturation of oocyte. In the present study, an attempt was made to isolate and study the biological properties of ovarian follicular fluid peptide(s) in buffaloes. Bubaline ovarian follicular was made steroid- and cell-free. A protein fraction was obtained by saturation (30-35% level) of the follicular fluid with ammonium sulfate. The protein fraction was purified with Sephadex-G 50 gel filtration chromatography and a single peak was obtained in the eluant volume, which was lyophilized. SDS-PAGE of the lyophilized fraction revealed a single band and the molecular weight of the peptide was 26.6 kDa. The peptide stimulated the cumulus cell expansion and in vitro maturation rate of oocytes in buffaloes in a dose dependent manner when it was incorporated at different dose levels (0, 10, 25, 50, 100 and 1,000 ng $ml^{-1}$ of maturation medium). The basic culture medium consisted of TCM 199 with Bovine serum albumin (0.3%). The in vitro maturation rates were comparable to those obtained with a positive control medium (TCM 199+20 ng EGF $ml^{-1}$+steer serum (20%)). Further purification and biological assays may throw more light on the nature and functions of this peptide.

Fe3O4 Nanoparticles on MWCNTs Backbone for Lithium Ion Batteries

  • Lee, Kangsoo;Shin, Seo Yoon;Yoon, Young Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.3
    • /
    • pp.376-380
    • /
    • 2016
  • A composite electrode made of iron oxide nanoparticles/multi-wall carbon nanotube (iNPs/M) delivers high specific capacity and cycle durability. At a rate of $200mAg^{-1}$, the electrode shows a high discharge capacity of ${\sim}664mAhg^{-1}$ after 100 cycles, which is ~ 70% of the theoretical capacity of $Fe_3O_4$. Carbon black, carbon nanotube, and graphene as anode materials have been explored to improve the electrical conductivity and cycle stability in Li ion batteries. Herein, iron oxide nanoparticles on acid treated MWCNTs as a conductive platform are combined to enhance the drawbacks of $Fe_3O_4$ such as low electrical conductivity and volume expansion during the alloying/dealloying process. Enhanced performance was achieved due to a synergistic effect between electrically 3D networks of conductive MWCNTs and the high Li ion storage ability of $Fe_3O_4$ nanoparticles (iNPs).

Effects of Vapor Injection on a Compressor in a Transcritical CO2 Cycle (초임계 CO2 사이클에서 가스 인젝션이 압축기 성능에 미치는 영향)

  • Kim, Woo-Young;Shim, Jae-Hwi;Lee, Yong-Ho;Kim, Hyun-Jin
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.2 s.41
    • /
    • pp.16-21
    • /
    • 2007
  • Potential advantages of using vapor injection in a two stage rotary compressor for a $CO_2$ heat pump water heater system were addressed in this paper by numerical simulation. Vapor separated from a flash tank in the middle of the expansion process can be used for injection into the second stage suction plenum of the compressor to improve the system performance. Vapor injection increases the intermediate pressure between the two stages, thus increasing the first stage compressor work and reducing that of the second stage. As a whole, however, the compressor input power increases due to injected mass flow rate for the second stage. Computer simulation showed that increment of the cooling capacity by vapor injection exceeded that of the compressor work, thus improving the system performance. COP improvement by vapor injection was calculated to be about 5-14% for normal operating conditions. With vapor injection, a maximum COP was found when the displacement volume of the second stage becomes 90-95% of that of the first stage of the compressor.