• Title/Summary/Keyword: Volume control unit

Search Result 160, Processing Time 0.024 seconds

SHIHMEN SEDIMENT PREVENTION DIVERSION TUNNEL PLANNING AND DESIGN

  • Ho-Shong Hou;Ming-Shun Lee;Percy Hou
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.168-172
    • /
    • 2009
  • Shihmen reservoir was started in May 1963. The main purposes of Shihmen reservoir are for agriculture, power supply, flood control and tourism. Shihme Asn dam is an earth dam. Its crown height is 133m above mean sea level, with length 360 m, watershed 763.4 km2, and maximum volume 309 million cms. Turbidity in Shihmen dam was severely affected by typhoons Aere (2004) and Masa (2005). Increased deposition after Aere was 28 million cms. Turbidity at Shihmen Canal Inlet is 3000 NTU (Nephelometry Turbidity Unit). Sediment sluicing strategies for downstream channel are demanded. Therefore, diversionary sediment preventing channel is planned in the upstream of Shihmen reservoir. Finally, turbid flow in tunnel channel is bypassed and diverted its flow down to downstream.

  • PDF

Investigation of Transient Performance of An Auxiliary Power Unit Microturbine Engine (보조동력용 마이크로터빈 엔진에 대한 과도성능 해석)

  • Son, Ho-Jae;Kim, Soo-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.3
    • /
    • pp.20-28
    • /
    • 2007
  • The easiest way to see the phenomena of compressor surge is to show the static and dynamic operation characteristic on the map. Its operation zone will be restricted by the surge limit and, static and transient process must have some margin for it. Effect of rotor moment of inertia, air/gas volumes and heat transfer are factors to cause the transition from the static line. In case a large volume such as heat exchanger exists in the system it will exert a substantial influence to dynamic characteristics. In the present paper, influence of air volume bled from the compressor exit on transient process is investigated with an example of an auxiliary power unit micro-turbine engine. Turbine mass, pressure ratio, rotation speed, power and moment are calculated based on mass and work conservation. Result from the present study can give guidance to design the control system. A computer program is developed to calculate the dynamic process using the MathCAD commercial software.

The Pharmacokinetics of Nimodipine After Oral Administration in Rabbits with Hepatic Failure

  • Choi, Jun-Shik;Choi, In;Burm, Jin-Pil
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.1
    • /
    • pp.19-22
    • /
    • 2006
  • The pharmacokinetics of nimodipine, following a single 16 mg/kg oral dose, was investigated in rabbits with hepatic failure induced by 0.5 mL/kg (mild), 1.0 mL/kg (moderate) and 2.0 mL/kg (severe) of carbon tetrachloride $(CCl_{4}$ : olive oil = 20 : 80, v/v). The plasma concentrations of nimodipine were determined by a high performance liquid chromatographic assay. The levels of sGOT and sGPT in rabbits with mild $(86.2{\pm}29.0\;and\;98.5{\pm}33.1\;unit/dL)$, moderate $(168.1{\pm}61.2\;and\;196.2{\pm}66.0\;unit/dL)$ and severe $(292.7{\pm}82.2\;and\;314.2{\pm}99.8\;unit/dL)$ hepatic failure were significantly increased compared to the control $(38.0{\pm}10.1\;and\;32.4{\pm}10.2\;unit/dL)$. The area under the plasma concentration-time curve (AUC) of nimodipine was significantly increased in mild $(131.7{\pm}28.1%)$, moderate $(168.8{\pm}32.8%)$ and severe $(204.6{\pm}58.3%)$ carbon tetrachloride-induced hepatic failure rabbits compared to the control (100%) rabbits. The volume of distribution $(V_{d})$ and the total body clearance $(CL_{t})$ of nimodipine were significantly decreased in all hepatic failure groups. The elimination rate constant $(K_{el})$ of nimodipine was significantly decreased in moderate and severe carbon tetrachloride-induced hepatic failure rabbits. There was a correlation between sGOT (y= 1.01x+241, r=0.993) or sGPT (y=0.92x +243, r=0.997) value and the AUC of nimodipine in the rabbits with hepatic failure. These findings suggest that the hepatic metabolism of nimodipine was inhibited by carbon tetrachloride-induced hepatic failure rabbits, resulting in the decrese in $V_{d}$ and $CL_{t}$ of nimodipine in the rabbits with mild, moderate and severe hepatic failure.

가변 풍량 유닛에 의한 실내 공간의 온도제어를 위한 공간의 분할 모델과 상태궤환 제어기의 개발에 관한 연구

  • 박세화;신승철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.947-959
    • /
    • 2001
  • We propose a control scheme to control the indoor zone temperature via variable air volume (VAV) unit. To control the room temperature, state space model of the conditioned zone which is partitioned into nine artificial sectional regions is derived. The nonlinearity of the damper motion and actuator are considered for the practical use in the state space system description. The temperature control of the room temperature is performed by manipulating the degree of openness of the damper in relation to the local room temperature and the supplied air flow rate. In general, since a local temperature in the conditioned zone is measured, it is required to estimate the temperature values in each regions for the precise temperature control. We thus design a state observer to estimate the regional temperature, and use these values in the controller. The overall control system consists of the state observer based state feedback with the integral control. We compared the control results of the proposed scheme with those of cascade proportional and integral (PI) control, and showed that the scheme achieved precise control of the conditioned system.

  • PDF

A Development Tendency and Feature Study of Generator for Small Aircraft Engine (소형 항공엔진용 발전기 개발동향 및 특성고찰)

  • Kim, In-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.491-494
    • /
    • 2010
  • This paper describes the characteristics of Permanent Magnet Generator(PMG) and Homo-Polar Gnerator(HPG) applied in small aircraft engine. PMG has a advantage of miniaturization and fast bandwidth if it is using the DC/DC converter for power conversion which increases a volume and cost although. On the other hand, HPG has a advantage of simple voltage control accomplished by flux control of field coil. Recently, it is recommended the PMG without DC/DC converter module by reason of the wide range of input voltage of electronic loads and system efficiency.

  • PDF

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

Performance Evaluation of Artificial Lightweight Aggregate Mortar Manufactured with Waste Glass (폐유리로 제조된 인공경량골재를 이용한 모르타르의 물리적 성능에 대한 평가)

  • Kim, Seong-Soo;Lee, Jeong-Bae;Nam, Ba-Reum;Park, Kwang-Pil
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.147-152
    • /
    • 2009
  • The compressive strength test, bulk density and mortar absorption ratio were carried out to utilize the data as the basic sources for the lightweight mortar and the lightweight concrete, through the study on the physical characteristics of the artificial lightweight aggregate (ALA) made of waste glasses, which was developed for the first time in the country. On the basis of these experiments, the density and the unit volume weight of the ALA showed the value less than 50% of the common aggregate due to the independent pore structure, and the mortar that contains ALA had no big difference from the Control mortar in the test of the absorption ratio. It is judged that this happens based on the internal independent pore structure of the ALA. In case of the mortar containing ALA, there was a tendency of declination in the compressive strength and the bending strength as the mixing rate is increasing, but all mortar showed more than 70% of the Control mortar compressive strength except for the La50 mortar. Hereafter, it is judged that according to the control of the mixing ratio of mineral admixing agent, water and cement, it will realize the equal strength to the control mortar, and the long term edurance is needed to be considered together.

Drive Controller System in PM Motor with Independently Excited Winding for an Electric Bicycle (전기자전거용 독립여자권선 영구자석 전동기의 구동제어기 설계)

  • Choi, Jin-Wook;Son, Young-Dae;Kang, Gyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.175-177
    • /
    • 2007
  • This paper presents for the torque characteristics and improving the efficiency of driving system of electric bicycle which applied IEWPM(Independently Excited Winding Permanent Magnet) motor. IEWPM motor can expand the number of phase from 3 phases to multiphase like SRM motor because stator windings are unconnected directly. BLDC motor raise rotor'-s electromagnetic torque per unit volume by using Spoke type permanent magnet. By using two photo sensor per phase and applying excited width, advance angle and bipolar control, we confirmed higher torque at a low speed, higher out-put at a high speed, and efficiency improvement at a wide speed control area.

  • PDF

A Study of Rule-based Fault Detection Algorithm in the HVAC System (규칙기반 고장진단 알고리즘의 실험적 연구)

  • Cho, Soo;Tae, Choon-Seob;Jang, Cheol-Yong;Yang, Hoon-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.241-246
    • /
    • 2005
  • The objective of this study is to develop a rule-based fault detection and diagnosis algorithm and an experimental verification using air handling unit. To develop an analytical algorithm which precisely detects a faulted component, energy equations at each control volume of AHU were applied. An experimental verification was conducted in the AHU at Green Building in KIER. In the experiment conducted in hot summer condition, the rule based FDD algorithm isolated a faulted sensor from HVAC components.

  • PDF

An Experimental Study on Fault Detection in the HVAC Simulator (공조 시뮬레이터를 이용한 고장진단 실험 연구)

  • Tae, Choon-Seob;Yang, Hoon-Cheul;Cho, Soo;Jang, Cheol-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.807-813
    • /
    • 2006
  • The objective of this study is to develop a rule-based fault detection algorithm and an experimental verification using an artificial air handling unit. To develop an analytical algorithm which precisely detects a tendency of faulty component, energy equations at each control volume of AHU were applied. An experimental verification was conducted on the HVAC simulator. The rule based FDD algorithm isolated a faulted sensor from HVAC components in summer and winter conditions.

  • PDF