In-situ 진공게이지 교정장치 개발 (Development of an Apparatus for In-situ Vacuum Gauge Calibration)

  • 홍승수;임인태;조문재;정원호
    • 한국진공학회지
    • /
    • 제15권6호
    • /
    • pp.605-611
    • /
    • 2006
  • 정적법(constant volume method)을 이용하여 $1Pa\sim100kPa$ 영역에서 진공게이지의 직접교정 (direct calibration) 장치를 개발하였다. 이 장치는 피 교정 게이지의 이동 없이 in-situ 상태에서 비교교정(comparison calibration)도 가능하다. 이 장치가 개발됨으로서 산업체 교정기관의 생산성을 높이고 개발도상국에 국가 진공표준과 교정기술을 보급할 수 있게 되었다.

극저온(20K) 수소동위원소 흡착 등온선의 온도 변화에 대한 자동 저온 부피 교정 (Automated Cold Volume Calibration of Temperature Variation in Cryogenic Hydrogen Isotope Sorption Isotherm)

  • 박재우;오현철
    • 한국재료학회지
    • /
    • 제29권5호
    • /
    • pp.336-341
    • /
    • 2019
  • The gas adsorption isotherm requires accurate measurement for the analysis of porous materials and is used as an index of surface area, pore distribution, and adsorption amount of gas. Basically, adsorption isotherms of porous materials are measured conventionally at 77K and 87K using liquid nitrogen and liquid argon. The cold volume calibration in this conventional method is done simply by splitting a sample cell into two zones (cold and warm volumes) by controlling the level sensor in a Dewar filled with liquid nitrogen or argon. As a result, BET measurement for textural properties is mainly limited to liquefied gases (i.e. $N_2$ or Ar) at atmospheric pressure. In order to independently investigate other gases (e.g. hydrogen isotopes) at cryogenic temperature, a novel temperature control system in the sample cell is required, and consequently cold volume calibration at various temperatures becomes more important. In this study, a cryocooler system is installed in a commercially available BET device to control the sample cell temperature, and the automated cold volume calibration method of temperature variation is introduced. This developed calibration method presents a reliable and reproducible method of cryogenic measurement for hydrogen isotope separation in porous materials, and also provides large flexibility for evaluating various other gases at various temperature.

도로시설 규모산정에 있어서 교통량 정산과정에 따른 경제적 편익 차이에 관한 연구 (A Study on Differences of Economic Benefits by Volume Calibration in Road Construction Projects)

  • 김상구;김근덕
    • 대한교통학회지
    • /
    • 제27권5호
    • /
    • pp.7-16
    • /
    • 2009
  • 본 연구는 도로사업의 경제적 타당성 분석시 적용되는 편익에 대한 정확성을 높이기 위한 방안을 제시하는 연구이다. 기존 경제적 평가방법의 문제점은 모형의 정산시 교통량만을 정산하기 때문에 실제 교통량과 비슷하게 모형이 정산되지만 모형에서 나오는 통행속도는 실제 속도와 차이를 나타낼 수 있다는 점이다. 실제통행속도와 다른 모형속도는 차량운행비, 통행시간, 대기오염 절감 편익들이 잘못 산정될 수 있게 한다. 따라서, 본 연구에서는 2개의 서로 다른 VDF를 가지고 도로망에서 비슷한 교통량 정산에 의해 서로 다른 속도로 산출된 후 서로 다른 모형속도 결과에 따른 경제적 편익의 차이가 크게 발생되는 문제점을 확인하였다. 이러한 문제점에 대한 개선방향으로 교통량에 따른 정확한 속도를 산출하는 VDF 함수 개발을 포함한 3가지 개선방안을 제시하여 향후 정확한 편익산정과 이로 인한 합리적인 경제성분석이 수행될 수 있는 토대를 마련하였다.

스테레오 카메라와 비균일 메시를 이용한 체적 계산 알고리즘 (Volume Calculation Using Stereo Camera and Non-uniform Mesh)

  • 이영대;조성윤
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2012년도 제46차 하계학술발표논문집 20권2호
    • /
    • pp.429-432
    • /
    • 2012
  • 이 논문에서는 쓰레기 매립의 표준화를 위한 일환으로 쓰레기 체적을 주기적으로 계산하는 알고리즘을 제시하였다. 안전하고 쾌적한 도시 환경을 조성하기 위해 폐기물 매립 시설은 필요하며 폐기물 부피 관리의 신뢰성 및 용량 정보의 정확성을 파악하는 것이 필요하다. 카메라 캘리브레이션 이후에 대상체의 표면에 대한 포인트 클라우드(point cloud)를 얻을 수 있었으며 이것을 물체의 체적 계산 알고리즘의 입력으로 선택하였다. 비균일 격자(uniformmeshing) 방법에 기초한 체적 계산 알고리즘을 제안하였으며 알고리즘의 타당성을 시뮬레이션과 실제 실험을 통해 입증하였다. 제시된 알고리즘은 쓰레기 매립의 체적 계산 뿐 만이 아니라 삼차원 객체의 일반적인 체적 계산을 위한 알고리즘으로도 사용될 수 있다.

  • PDF

복부에서 측정하는 일회 호흡용적의 정확도 평가 (Accuracy Evaluation of Tidal Volume Measured on the Abdomen)

  • 이인광;김성식;장종찬;김군진;김경아;이태수;차은종
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1298-1303
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. This study implemented respiratory monitoring system with the conductive rubber cord in the patient's pants in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%$ $CO_2$ was inhaled and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation significantly increased the tidal volume in normal physiological state with the subject unawared. The tidal volume estimated from the abdominal dimension change linearly correlated with the tidal volume measured by a pneumotachometer with a correlation coefficient of 0.88. Customized calibration for each subject resulted in relative errors less than 10%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

Study on Calibration Methods of Discharge Coefficient of Sonic Nozzles using Constant Volume Flow Meter

  • 정완섭;신진현;강상백;박경암;임종연
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.17-17
    • /
    • 2010
  • This paper address technical issues in calibrating discharge coefficients of sonic nozzles used to measure the volume flow rate of low vacuum dry pumps. The first challenging issue comes from the technical limit that their calibration results available from the flow measurement standard laboratories do not fully cover the low vacuum measurement range although the use of sonic nozzles for precision measurement of gas flow has been well established in NMIs. The second is to make an ultra low flow sonic nozzlesufficient to measure the throughput range of 0.01 mbar-l/s. Those small-sized sonic nozzles do not only achieve the noble stability and repeatability of gas flow but also minimize effects of the fluctuation of down stream pressures for the measurement of the volume flow rate of vacuum pumps. These distinctive properties of sonic nozzles are exploited to measure the pumping speed of low vacuum dry pumps widely used in the vacuum-related academic and industrial sectors. Sonic nozzles have been standard devices for measurement of steady state gas flow, as recommended in ISO 9300. This paper introduces two small-sized sonic nozzles of diameter 0.03 mm and 0.2 mm precisely machined according to ISO 9300. The constant volume flow meter (CVFM) readily set up in the Vacuum center of KRISS was used to calibrate the discharge coefficients of the machined nozzles. The calibration results were shown to determine them within the 3% measurement uncertainty. Calibrated sonic nozzles were found to be applicable for precision measurement of steady state gas flow in the vacuum process. Both calibrated sonic nozzles are demonstrated to provide the precision measurement of the volume flow rate of the dry vacuum pump within one percent difference in reference to CVFM. Calibrated sonic nozzles are applied to a new 'in-situ and in-field' equipment designed to measure the volume flow rate of low vacuum dry pumps in the semiconductor and flat display processes.

  • PDF

A Volume Reconstruction Algorithm and a Coordinate Calibration of an X-ray Three Dimensional Imaging System

  • Roh, Young-Jun;Cho, Hyung-Suck;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.63.3-63
    • /
    • 2001
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. In this paper, we propose a three dimensional volume reconstruction method, which is an iterative method and as uniform and simulated algebraic reconstruction technique (USART). In this method, two or more x-ray images projected from different views are needed, and also the geometry of the imaging system need to be a priori identified well. That is to say, the relative locations between the x-ray source, imaging plane and the object should be determined exactly by calibration. To achieve this, we propose a series of coordinate calibration methods of the x-ray imaging system using grid pattern images. Some experimental results of these calibrations is presented and discussed in detail ...

  • PDF

집계자료를 이용한 미시적 시뮬레이션 모형의 자동정산체계 개발 (도시고속도로사례) (Development of Auto-calibration System for Micro-Simulation Model using Aggregated Data (Case Study of Urban Express))

  • 이호상;이태경;마국준;김영찬;원제무
    • 대한교통학회지
    • /
    • 제29권1호
    • /
    • pp.113-123
    • /
    • 2011
  • 미시적 시뮬레이션 모형은 컴퓨터 성능이 향상되고 정교한 모형이 개발되면서 광역적인 범위까지 적용분야가 점차 확대되고 있다. 현장 교통상황을 정확하게 묘사하기 위해서는 시뮬레이션 모형의 정확한 정산이 매우 중요하다. 국내에서는 거시적 모형에 대한 정산연구는 많이 진행된 반면에 미시적 모형에 대한 정산연구는 매우 부족한 실정이다. 본 연구에서는 유전자알고리즘 이용하여 미시적 시뮬레이션 모형의 파라미터를 자동으로 최적화하는 자동정산 체계를 제시하였다. 내부순환로 지점검지기에서 수집되는 관측교통량과 미시적 시뮬레이션모형(VISSIM)의 교통량 간의 제곱오차(RMSE)를 성능지표로 하고, 최적화 목적함수는 제곱오차를 최소화 하는 것으로 설정하였다. 내부순환로에 적용한 결과, 기본 파라미터에 비해 자동정산체계의 RMSE가 60.4%($19.3{\longrightarrow}7.6$)나 감소하여 매우 효과적인 것으로 나타났다.

Experimental technique for efficiency transfer along different geometries and volumes

  • Haddad, Kh;AL-Homyed, A.
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.695-698
    • /
    • 2021
  • Efficiency calibration is a fundamental procedure in gamma spectrometric measurement. Experimental technique for efficiency calibration transfer in gamma spectrometer along different geometries and volumes has been developed and validated in this work. The developed technique offers simple and easy procedures to overcome several problems encountered in efficiency calibration of gamma spectrometer such as rate-related correction and different sample volumes. The validation shows that application of the developed technique has a precision of 95%.

표준 마이크로폰 감도 교정을 위한 진동막의 모달 파라미터 측정 (Modal Parameter Estimation of Membrane for Standard Microphone Sensitivity Calibration)

  • 권휴상;서상준;서재갑;박준홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.298-302
    • /
    • 2002
  • Equivalent volume estimation of the coupler and two coupled microphones has a key role in standard microphone pressure calibration. The equivalent volume of the microphone is determined by the dynamic characteristics of the diaphragm system and front cavity. Therefore the modal parameters of diaphragm system - natural frequency and damping fatter - should be measured explicitly for the estimation of the equivalent volume. The diaphragm system is composed of the vibrating diaphragm, back slit behind diaphragm, pressure equalization vent, and front cavity which are acoustically coupled. In the measurement, the electrostatic actuator was used to excite the system with the swept sine, and the frequency response was obtained. The close actuator in front of the diaphragm must influence the radiation impedance of the system, and then the modal parameters. From the measured frequency response, the natural frequency and the damping factor could be estimated with the Complex exponential method based on the Prony model and the zero crossing real and imaginary plot.

  • PDF