• 제목/요약/키워드: Volume Velocity

검색결과 1,296건 처리시간 0.03초

플라즈마 디스플레이 패널(Plasma Display Panel) 텔레비전에서의 냉각 소음 저감

  • 김규영;최민구;이덕주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.719-724
    • /
    • 2003
  • The present experimental study deals with noise reduction and improvements in cooling performance in a plasma display panel(PDP) television (TV). To reduce the noise, the effects of installation parameters are studied. The experimental parameters under investigation are the distance between the fan and the rear case of a PDP TV, position of the strut on the fan, and the fan RPM. The variance of RPM is the most significant facto., and a 250 RPM decrease from 910 RPM causes about 4㏈(A) reduction in the system noise. To increase performance, flow characteristics are investigated by using a visualization technique and measuring the volume flow rate. The visualized results show that a radial direction flow due to large system resistance is significant, and an axial velocity oscillation is observed from the measurement of the volume flow rate. To prevent both a radial direction flow and an axial velocity oscillation, sponges are inserted in the space between f3n and the rear case. Inserted sponges improve the volume flow rate of cooling fans up to 32% since they convert a radial direction flow to an axial direction flow. Also an axial velocity oscillation with large amplitude and low RPM disappears. Increasing volume flow rate causes the PDP TV to improve its cooling performance. Additionally the same volume flow rate can be obtained with a decreased fan speed due to the inserted sponge. Noise reductions of 4.2 ㏈(A) at the rear and 1.1 ㏈(A) at the front of the TV are obtained by the decreased RPM. An increase of 10% of the volume flow rate is also achieved by inserting sponges.

  • PDF

휘발성 유기염소화합물의 촉매연소 연구 (The study of catalytic combustion of VOCs)

  • 이건주
    • 유기물자원화
    • /
    • 제14권1호
    • /
    • pp.169-177
    • /
    • 2006
  • 본 연구에서는 휘발성 유기 화합물의 촉매연소에 의한 제거 반응에 대하여 조사 하였다. 촉매와 VOC의 접촉형태(공간속도 및 촉매층의 높이)에 따라 완전연소온도가 조금씩 달라지며 공간속도(SV)는 처리가스의 유량(Q, $m^3/hr$)을 촉매 층의 부피(V,$m^3$)로 나눈 값(SV=Q/V)을 나타내는 값으로, 촉매연소 장치에서는 보통 $10,000{\sim}50,000hr^{-1}$을 유지한다 열교환기를 통한 VOC는 수소염 이온화 검출기를 통하여 농도를 측정하였으며 반응온도는 373K-423K에서 촉매를 활성화 시켜 VOC 농도의 제거효율을 측정하였다. 농도측정은 100회 이상하여 제거효율을 조사 하였다. 자동차 도장시설에서 VOC 배출농도는 63.37 ppm 이며 373K 촉매 활성시 제거율은 평균 70% 이며 423K 촉매 활성시 제거효율은 78.92% 이었다. 반응농도가 증가할수록 제거효율은 증가하는 경향이었다.

  • PDF

Effect on Varying the Impact Velocity in the Controlled Cortical Impact Injury Model : Injury Severity and Impact Velocity

  • Ji, Yong-Cheol;Min, Byung-Kook;Park, Seung-Won;Hwang, Sung-Nam;Hong, Hyun-Jong;Suk, Jong-Sik
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권1호
    • /
    • pp.41-46
    • /
    • 2005
  • Objective : A study of the histopathologic and neurobehavioral correlates of cortical impact injury produced by increasing impact velocity using the controlled cortical impact[CCI] injury model is studied. Methods : Twenty-four Sprague-Dawley rats [$200{\sim}250g$] were given CCI injury using a pneumatically driven piston. Effect of impact velocity on a 3mm deformation was assessed at 2.5m/sec [n=6], 3.0m/sec [n=6], 3.5m/sec [n=6], and no injury [n=6]. After postoperative 24hours the rats were evaluated using several neurobehavioral tests including the rotarod test, beam-balance performance, and postural reflex test. Contusion volume and histopathologic findings were evaluated for each of the impact velocities. Results : On the rota rod test, all the injured rats exhibited a significant difference compared to the sham-operated rats and increased velocity correlated with increased deficit [p<0.001]. Contusion volume increased with increasing impact velocity. For the 2.5, 3.0, and 3.5m/sec groups, injured volumes were $18.8{\pm}2.3mm^3$, $26.8{\pm}3.1mm^3$, and $32.5{\pm}3.5mm^3$, respectively. In addition, neuronal loss in the hippocampal sub-region increased with increasing impact velocity. In the TUNEL staining, all the injured groups exhibited definitely positive cells at pericontusional area. However, there were no significant differences in the number of positive cells among the injured groups. Conclusion : Cortical impact velocity is a critical parameter in producing cortical contusion. Severity of cortical injury is proportional to increasing impact velocity of cortical injury.

2사이클 기관 흡기 포오트의 가스 유동 특성에 관한 연구 (A study on the characteristics of gas flow in inlet port of 2 cycle engine)

  • 이창식
    • 대한기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.725-730
    • /
    • 1987
  • 본 연구에서는 2사이클 기관의 흡입 포오트 부근의 가스 유동을 레이저 도플 러 유속계를 이용하여 측정하고 가스의 평균 속도, 속도 변동, 유속 벡터 등을 기관의 회전 속도, 실린더 헤드의 모양 및 실린더로의 흡입 속도 측정점의 위치 변화에 대하 여 비교 검토하고, 유동 특성을 고찰하였다.

직접속도 피드백을 이용한 지능판의 능동구조음향제어 (Active Structural Acoustical Control of a Smart Panel Using Direct Velocity Feedback)

  • Stephen J, Elliott;Paolo, Gardonio;Young-Sup, Lee
    • 한국소음진동공학회논문집
    • /
    • 제14권10호
    • /
    • pp.1007-1014
    • /
    • 2004
  • This paper presents a study of low frequencies volume velocity vibration control of a smart panel in order to reduce sound transmission. A distributed piezoelectric quadratically shaped polyvinylidene fluoride (PVDF) polymer film is used as a uniform force actuator and an array of $4\;{\times}\;4$ accelerometer is used as a volume velocity sensor for the implementation of a single-input single-output control system. The theoretical and experimental study of sensor-.actuator frequency response function shows that this sensor-actuator arrangement provides a required strictly positive real frequency response function below about 900 Hz. Direct velocity feedback could therefore be implemented with a limited gain which gives reductions of about 15 dB in vibration level and about 8 dB in acoustic power level at the (1,1) mode of the smart panel. It has been also shown that the shaping error of PVDF actuator could limit the stability and performance of the control system.

슬러그류 액상속도 측정용 전류형식 전자기유량계 개발 (Development of a Current-Type Electromagnetic Flowmeter to Obtain the Liquid Mean Velocity in Two-Phase Slug Flow)

  • 강덕홍;안예찬;김종록;오병도;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1951-1956
    • /
    • 2004
  • The transient nature and complex flow geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et $al.^{(1)}$). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. To do this, the velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for the simulated slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are required for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

  • PDF

국가대표 소프트볼선수들의 흡기능력과 골밀도 및 골 질량 그리고 체간의 근력 및 근지구력의 상관관계 분석 (Analysis of correlation between the inspiratory capacity of the National softball players and the bone density, bon mass, muscle power, muscle endurance)

  • 김현철;박기준
    • 대한물리의학회지
    • /
    • 제15권1호
    • /
    • pp.95-104
    • /
    • 2020
  • PURPOSE: A prospective study was conducted to investigate the correlation between the inspiration ability, bone mineral density, lumbar muscle strength, and muscular endurance for the national softball athletes in the national training center. METHODS: The general characteristics of study subjects, inspiration ability, bone mineral density, muscle strength, and muscular endurance data were analyzed using descriptive statistics. In addition, the Pearson product moment correlation was performed to investigate the correlation between the inspiratory capacity, bone mineral density, muscle strength, and muscular endurance. RESULTS: The inspiration, flow rates, and volume were not correlated with the bone mass and bone mineral density. Inspiration and the flow rates and volume were not correlated with the bone mass and bone mineral density. On the other hand, inspiration was correlated with the Extensor muscles (r=.464, p=.006) at an angular velocity of 60°/s and the flexors (r=.463, p=.006) and extensor muscles (r=.615, p<.001) at an angular velocity of 180°/s. The flow rate was also correlated with the extensor muscles (r=.444, p=.009) at an angular velocity of 60°/s and with flexor muscles (r=.432, p=.011) and extensor muscles (r=.589, p<.001) at an angular velocity of 180°/s. Finally, the volume was correlated at the extensor muscles at an angular velocity of 180°/s (r=.534, p=.001). CONCLUSION: The correlation between the inspiratory capacity, bone mineral density, muscle strength, and muscular endurance of softball athletes did not correlate with the bone mass and bone density. On the other hand, the lumbar muscle strength increased with increasing inspiratory capacity.

수치해석을 이용한 바닥공조 시스템의 공기환경 평가 (Numerical Study on Indoor Air Quality Based on Age of Air for the Underfloor Air Distribution System)

  • 방승기;안혜린;이원근;문기선;김종률;이광호
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.40-46
    • /
    • 2016
  • In order to improve air quality of indoor environment, studies of the underfloor air distribution (UFAD) system for application in buildings are actively in progress based on temperature and air flow distribution. However, although the age of air is the major evaluation parameter, there has been very little study on this parameter for the UFAD system. In this study, we investigated the age of air to reach the air diffuser, which is installed at the bottom of the interior by the UFAD system. Computational fluid dynamics simulations showed no regular pattern to the maximum value of the age of air in accordance with air flow rate and the velocity at air diffuser. These factors can be deduced from air movement by considering that air emitted from air conditioners was rotated according to the bottom shape of the floor, and then, the age of air in the rotation center was increased. The average age of air of internal interior was reduced considerably as the flow velocity at the underfloor air diffuser was increased from 0.5 m/s to 1.0 m/s However, the age of air was not substantially affected with change in the air volume. Moreover, when the flow velocity at the underfloor air diffuser was higher than 1.0 m/s, the age of air showed no significant difference with change in air volume or height of measurement. These results imply that indoor air quality is more substantially influenced by flow velocity than air volume, and the appropriate flow velocity is 1 m/s or more.

Experimental investigation of blocking mechanism for grouting in water-filled karst conduits

  • Zehua Bu;Zhenhao Xu;Dongdong Pan;Haiyan Li;Jie Liu;Zhaofeng Li
    • Geomechanics and Engineering
    • /
    • 제34권2호
    • /
    • pp.155-171
    • /
    • 2023
  • Aiming at the grouting treatment of water inflow in karst conduits, a visualized experiment system for conduit-type grouting blocking was developed. Through the improved water supply system and grouting system, and the optimized multisource information monitoring system, the real-time observation of diffusion and deposition of slurry, and the data acquisition of pressure and velocity during the whole process of grouting were realized, which breaks through the problem that the monitoring element is easy to fail due to slurry adhesion in conventional test system. Based on the grouting experiments in static and flowing water, the diffusion and deposition behavior of the quick-setting slurry under different working conditions were analyzed. The temporal and spatial variation behavior of the pressure and velocity were studied, and the blocking mechanism of the grouting were further revealed. The results showed that: (1) Under the flowing water condition, the counter-flow diffusion distance of slurry was negatively correlated with the flow water velocity and the volume ratio of cement and sodium silicate (C-S ratio), and positively correlated with the grouting volume. The slurry deposition thickness was negatively correlated with the flowing water velocity, and positively correlated with the grouting volume and C-S ratio. (2) The pressure increased slowly before blocking of the flowing water and rapidly after blocking in karst conduits. (3) With the continuous progress of grouting, the flowing water velocity decreased slowly first, then significantly, and finally tended to be stable. According to the research results, some engineering recommendations were put forward for the grouting treatment of the conduit-type water inflow disaster, which has been successfully applied in the treatment project of the China Resources Cement (Pingnan) Limestone Mine. This study provided some guidance and reference for the parameter optimization of grouting for the treatment projects of water inflow in karst conduits.

소형 액체로켓엔진 인젝터 분무의 분사압력 변이에 따른 미립화 특성 (Atomization Characteristics of Small LRE-Injector Spray According to Injection Pressure Variation)

  • 정훈;김진석;김정수;박정
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.125-128
    • /
    • 2008
  • 이중모드 위상도플러속도계(Dual-mode Phase Doppler Anemometry, DPDA)를 이용하여 소형 액체 로켓엔진 인젝터 분무의 미립화 특성을 고찰하였다. 분무액적의 반경방향 이동에 따른 속도, 크기, 수밀도, 부피플럭스 등을 다양한 분사압력에서 측정하여 인젝터 분무의 공간분포 특성을 규명한다. 분사 압력이 증가함에 따라 분무액적의 속도, 난류강도, 수밀도, 그리고 부피플럭스는 증가하지만, 산술평균 직경($D_{10}$)과 분무액적의 증발율에 대한 척도인 Sauter Mean Diameter($D_{32}$)로 표현되는 액적의 크기는 감소하였다. 또, 속도와 부피플럭스는 Sauter 평균직경(Sauter mean diameter, SMD)에 비례하는 것을 알 수 있었다.

  • PDF