• Title/Summary/Keyword: Volume Size Distribution

Search Result 556, Processing Time 0.034 seconds

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

A Study on Intracavitary Therapy in Cervix Cancer Using Needle for Interstitial Therapy (조직 내 삽입용 바늘을 이용한 자궁경부암의 강내치료에 관한 연구)

  • Cho, Jung-Keun;Jung, Hong-Ryang;Lim, Cheong-Hwan;Kim, Jeong-Koo;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.83-92
    • /
    • 2006
  • Based on the data of cervical cancer patients who were treated by the radiotherapy with concurrent chemotherapy at the radiation oncology department of National Cancer Center from January 2002 to February 2003, we have studied the method recommended by ICRU 38 to maximize the prescription dose to the planing target volume (PTV) with minimizing the dose to surrounding normal organs. Clinical stage of the patients are 1 patient for stage IB, 3 patients for IIA, 19 patients for IIB, 3 patients for IIIA, 3 patients for IIIB and 1 patient for IV. All patients took the MRI before treatment and the maximum size of the gross tumor volume were under 4cm for 17 patients and from 4 cm to 6 cm for 12 patients and above 6 cm for 1 patient. The results show that while the irradiated volume can be reduced with optimized dose distribution using PTV treatment planning (p<0.0001) when the remained tumor size is small, the surrounding normal organs will receive unnecessarily large dose when the irradiated tumor volume is relatively large. This is because there is some limitation in controling the intensity of radiation in Fletcher Williamson Applicator. To overcome the limit of applicator and to achieve the optimal dose distribution, we have virtually applied 4 needles with Fletcher Williamson Applicator for 10 patients who have relatively large tumor and studied the change in dose distribution before and after application. The results show that this new virtual treatment plan reduces the volume covered by 100 % isodose (p=0.0608, p=0.0607) and reduces the dose of normal organs (p=0.0162, p=0.008). This evidence suggest that this method is superior than the currently used method such as PTV treatment and ICRU treatment.

  • PDF

The Properties of Porous and Non Porous Aminated Polystyrene Divinylbenzene Anion Exchanger (아민화된 다공성 및 비다공성 폴리스티렌 디비닐벤젠 음이온교환체의 성질)

  • Dong Won Kim;Jae Jick Oh;Tae Won Min
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.233-238
    • /
    • 1985
  • The non-porous and porous polystyrene divinylbenzene copolymers were prepared by the suspension polymerization method. The non-porous aminated polystyrene divinylbenzene, N-APSTDVB and the porous aminated polystyrene divinylbenzene, P-APSTDVB of 50∼100mesh size weakly basic anion exchanger were synthesized by chloromethylation followed by amination with methylamine. The functional groups of these synthesized anion exchangers were confirmed by their infrared spectra. The maximum capacity of these exchangers was 4.86meq/g. Pore volume and pore spectra were determined with a mercury porosimeter. The pore volume of P-PSTDVB increased with increasing X$_{diluent}$ at 30% of divinylbenzene. However, the pore volume of P-PSTDVB increased with increasing volume percent of divinylbenzene at constant mole fraction of diluent, X$_{diluent}$ of 0.5. The pore volume of synthesized copolymer and anion exchanger at 8% divinylbenzene and 0.5X$_{heptane}$ decreased as follows; P-PSTDVB 〉P-APSTDVB 〉N-PSTDVB. This result was attributed to the possibility that the pore volume were reduced by amination reactions. The distribution coefficients of boric acid on the N-APSTDVB anion exchanger in various concentrations of alcohol water solutions showed that as alcohol concentration increased, the distribution coefficients values decreased due to the reduced concentration of H$_2$BO$_3^-$.

  • PDF

Preparation of Spherical Granules of Dolomite Kiln Dust as Gas Adsorbent

  • Choi, Young-Hoon;Huh, Jae-Hoon;Lee, Shin-Haeng;Han, Choon;Ahn, Ji-Whan
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • It is highlighted that increasing the adsorbent surface area on volumetric basis is very important in providing an easy access for gas molecules. Fine particles around $3{\mu}m$ of soft-burned dolomite kiln dust (SB-DKD) were hydrated to wet slurry samples by ball mill process and then placed in a chamber to use spray dryer method. Spherical granules with particle size distribution of $50{\sim}60{\mu}m$ were prepared under the experimental condition with or without addition of a pore-forming agent. The relationship between bead size of the pore-forming agent and size of SB-DKD particles is the most significant factor in preparation of spherical granules with a high porosity. Whereas addition of smaller beads than SB-DKD resulted in almost no change in the surface porosity of spherical granules, addition of larger beads than SB-DKD contributed to obtaining of the particles with both 15 times larger average pore volume and 1 order of magnitude larger porosity. It is considered that spherical granules with improved $N_2$ gas adsorption ability may also be utilized for other atmospheric gas adsorption.

Combustion and Nano-particulate Emissions Characteristics of a Compression Ignition Engine Fueled with Oxygenated Blending Fuel (압축착화 엔진에서 함산소 혼합연료의 연소 및 미세입자 배출물 특성)

  • Cha, June-Pyo;Yoon, Seung-Hyun;Chon, Moo-Soo;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.61-66
    • /
    • 2009
  • An experimental investigation was conducted to analyze the effects of biodiesel-ethanol and biodiesel-diesel blended fuels on the characteristics of combustion and exhaust emissions, and size distributions of particulate matter in a single cylinder diesel engine. The three types of test fuel were biodiesel and two blended fuels which were added ethanol and diesel by 20 % volume based fraction into biodiesel, respectively. In this study, the injection rate, combustion pressure, exhaust emissions and size distributions of particulate matter were measured under various injection timings and injection pressures. The experimental results show that biodiesel-ethanol blended fuel has lengthened ignition delay and low combustion pressure in comparison with those of biodiesel and biodiesel-diesel blended fuel even if all fuels indicated similar trends of injection rate under equal injection pressures. In addition, the ethanol blended fuel significantly reduced nitrogen oxidies (NOx) and soot emissions. And then the size distribution of particulate matters shows that blended fuels restrain the formation of particles which were beyond the range of 150nm comparison with biodiesel fuel.

Studies on the Pore of Coating Layer and Printability(III) -Effects of Properties of Latices on Pore of Coating Layer- (도공층의 공극과 인쇄적성에 관한 연구(제3보) -라텍스의 특성이 미치는 영향-)

  • 이용규;김창근
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.2
    • /
    • pp.41-48
    • /
    • 2001
  • This paper was made to evaluate the effect of the type of latex for coating on the printability by investigating the structure of pore such as the pore fraction, the number of pores, pore size and distribution of coated paper. The coated structure is mainly depend on the results of interaction between pigment and binder. It means that the structure of pore formed is chiefly affected by the type of latex. This physical properties of pore have a close relation with ink set-off associated with the drying rate, the speed of penetration of ink into base paper and printing gloss. Therefore it was necessary to find out the relationship between pore structure and the performance of printability by modifying the type of latex to vary the pore structure of coated paper. Acrylic latex was superior to S/B latex in the sedimentation volume, compressibility, smoothness, pore fraction and its number, the weight of transferred ink onto the coated paper and ink repellance. In contrast, water retention and ink setting were not good. in the comparison of anionic and amphoteric latex, amphoteric latex showed better performance in the thickness, smoothness, pore fraction and its number, pore size, the weight of ink transmitted and K&N ink receptivity, etc.

  • PDF

Determination of Heavy Metals Concentrations in Urban Air using ICP Method : in the Area of Chung-Ang University (ICP법에 의한 도시대기중 중금속 농도 측정: 중앙대학교를 중심으로)

  • 손동헌;신혜숙;정성윤;정원태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.222-229
    • /
    • 1993
  • Total suspended particles in the atmosphere were collected on the quartz fiber filters using an ANdersen Hi-volume air sampler from March 1989 to October 1989 and from June 1990 to February 1991, at Chung-Ang University in Seoul. A total amount of eight heavy metals (Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) in total suspended particles were determined by ICP spectrophotometer. The annual arithmetic mean concentration of total suspended particle was 162.3$\mug/m^3$ and eight metals(Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) were 11.6, 609.2, 3.5, 337.1, 2739.5, 15.1, 89.4 and 100.5ng/$m^3$, respectively. The concentration of total suspended particle was highest in the spring(343.7$\mug/m^3$) and lowest in the summer(91.8$\mug/m^3$). These heavy metals were distinguished into two groups in terms of their particle size distribution. The contents of first-group heavy metals (Fe, Ti, Mn) were increased in accordance with the growth of the particle size. The contents of the second-group ones such as Pb, Cd, V, and Zn, on the contrary, came to increase according as the particle size reduced. Statistical analysis indicated that there was a correlation between total suspended particle and Fe in coarse particles, and between total Suspended Particle and Zn, Pb in fine particle.

  • PDF

Activation of Carbon Fibers by KOH and Adsorption Characteristics for VOC (탄소섬유의 KOH 활성화와 휘발성 유기화합물(VOC)의 흡착특성)

  • Jang, J.S.;Kim, I.K.;Yim, G.;Cho, S.J.
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.362-367
    • /
    • 1999
  • We intended to make the activated carbon fibers which could separate, remove and recover the volatile organic compounds of benzene, toluene, acetone and methanol. Changing activation temperature and time, large specific surface area and narrow pore distribution could be obtained. The activated carbon fibers have large adsorption capacity and selectivility for those organic compounds. We characterized the adsorption capability of the activated carbon fibers for benzene, toluene, acetone and methanol by BET specific surface area and pore size and micropore volume measurements. In the result of activation, the maximum value of BET specific surface area of the fibers was $1100\m^2$/g at $800^{\circ}C$ for 60 minutes and $K_2$O was reduced actively in this condition. Their average pore size was 5.8~5.9$\AA$. The activated carbon fibers prepared in this work had high adsorption rate to saturation and the selectibility for the above organic compounds. The adsorbed amount of acetone and methanol(diameter of$ 4.3\AA$ and $4.4\AA$ respectively) which are smaller than micropore diameter in size was 43~49%, which was larger value than benzene and toluene(in the same diameter as $5.9\AA$).

  • PDF

Effects of Recycled Washwater on Pollutant Removal and Particle Characteristics during Coagulation (회수수가 응집공정의 오염물질 제거 및 입자특성에 미치는 영향)

  • 문병현;김승현;박미선;이향인;이강춘
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.955-960
    • /
    • 2002
  • The recycled washwater, which has different water quality and is produced about 5 to 20% of the total water volume treated, affects the unit operation of water treatment, especially coagulation process. However, the effects of recycled washwater on unit operation of water treatment have not been fully investigated. In this study, effects of recycled washwater on coagulation process were investigated to find the optimum coagulation condition by analyzing turbidity, $UV_{254}$, TOC removal efficiencies. In addition, effects of recycled washwater on residual Al after coagulation were studied by analyzing soluble and particulate Al. The size distribution and fractal dimension of coagulated also analyzed. The recycled washwater was lower pH than the raw water. And the recycled washwater had higher $UV_{254}$, TOC and residual Al concentration than the raw water. Residual Al concentration of recycled washwater was about 50 times higher than that of raw water. Optimum coagulant dosages on the blending recycled washwater and the raw water for turbidity, $UV_{254}$ and Al removal were lower than that on the raw water. However, TOC removal increased by increasing coagulant dosage. The size and fractal dimension of coagulated particle produced in the blending recycled washwater were larger, which imply faster settling velocity, than those produced in the raw water only.

Average Droplet Size Distribution of a GDI Spray by Simultaneous Fluorescence/Scattering Image Technique (형과/산란광 동시 측정에 의한 GDI 분무의 평균 입경 분포에 관한 연구)

  • Gwak, Su-Min;Ryu, Gyeong-Hun;Choe, Dong-Seok;Kim, Deok-Jul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.868-875
    • /
    • 2001
  • The objective of this study is to investigate the average droplet size distributions of a GDI spray by simultaneous fluorescence/scattering image technique. GDI engine is recently very popular because of high engine efficiency and low emissions. However, the injectors must have good spray characteristics because the fuel is directly injected into the cylinder. The fuel mixtures used in this study were 2% of fluorobenzene, 9% of DEMA(diethyl-methyl-amine) and 89% of hexane by volume. The system for obtaining 2-D fluorescence/scattering images of fuel spray was constituted of a laser sheet, a doubling prism, optical filters, and an ICCD camera. Using the ratio of the fluorescence to the scattering intensities, SMD distributions were obtained. SMD measured by the technique was compared with that obtained by PDA. It was found that average droplet size was bigger at spray center in the early stage of injection and at the outer periphery of the spray in the late stage of injection.