• Title/Summary/Keyword: Volume Efficiency

Search Result 2,153, Processing Time 0.036 seconds

Research on Improvement of Efficiency in Flat Plate Solar Collector by Using Double-Wall Glazing and VIP Insulation (이중투과체 및 VIP복합 단열재 적용 평판 집열기의 성능 향상에 대한 연구)

  • Lee, Doo Ho;Jang, Han Bin;Kim, Young Hak;Do, Kyu Hyung;Lee, Kwang Seob;Lyu, Nam Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.458-465
    • /
    • 2016
  • The purpose of this research is to improve the thermal effiency of solar collector and to quantitatively analyze its performance. Solar thermal systems have been limited to water heating systems mainly using low-temperature range. However, through diverse developments, the application has been extended to medium- and high-temperature fields such as solar heating, solar air conditioning, and solar thermal industrial process. Among the diverse research, this research is specially focusing on enhancement of the thermal performance by minimizing the heat loss coefficient of flat plate solar collectors. In order to do it, a front-side glazing material and a back-side insulation material with high insulated structure is proposed and based on computational analysis, the performance of energy collecting volume of the proposed solar collector is analyzed. The research shows that the proposed structure has the excellent performance at medium- and high-temperature range. therefore, it is expected that the proposed structure can easily replace existing technologies.

CFD Analysis on the Flow Characteristics of Ejector According to the Position Changes of Driving Nozzle for F.W.G (수치해석을 이용한 담수장치용 이젝터의 노즐위치 변화에 따른 이젝터 유동특성 연구)

  • Joo, Hong-Jin;Jung, Il-Young;Yun, Sang-Kook;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.23-28
    • /
    • 2011
  • In this study, the ejector design was modeled using Fluent 6.3 of FVM(Finite Volume Method) CFD(Computational Fluid Dynamics) techniques to resolve the flow dynamics in the ejector. A vacuum system with the ejector has been widely used because of its simple construction and easy maintenance. Ejector is the main part of the desalination system, of which designs determine the efficiency of system. The effects of the ejector was investigated geometry and the operating conditions in the hydraulic characteristics. The ejector consists mainly of a nozzle, suction chamber, mixing tube (throat), diffuser and draft tube. Liquid is supplied to the ejector nozzle, the fast liquid jet produced by the nozzle entrains and the non condensable gas was sucked into the mixing tube. The multiphase CFD modeling was carried out to determine the hydrodynamic characteristics of seawater-air ejector. Condition of the simulation was varied in entrance mass flow rate (1kg/s, 1.5kg/s, 2kg/s, 2.5kg/s, 3kg/s), and position of driving nozzle was located from the central axis of the suction at -10mm, 0mm, 10mm, 20mm, 30mm.. Asaresult, suction flow velocity has the highest value in central axis of the suction.

Efficiency of Embolization for Kidney Injury (신손상 환자에서 혈관 색전술의 효용성)

  • Kwon, Young-Kee;Chang, Hyuk-Soo;Kim, Byung-Hoon;Park, Choal-Hee;Kim, Chun-Il
    • Journal of Trauma and Injury
    • /
    • v.23 no.1
    • /
    • pp.16-20
    • /
    • 2010
  • Purpose: High-grade (III, IV, V) renal injury may need interventional management. We investigated whether the selective embolization of the renal artery is effective for the treatment of major renal injury in comparison with emergency renal exploration. Methods: We retrospectively reviewed the medical and radiologic records of patients who underwent surgery or embolization for renal injury (Grade III, IV, V) between January 1990 and December 2007. We analyzed the change in treatment method before and after 2000, the blood pressure, the hemoglobin at the time of visit, the hospital days and the complications in patients who received surgery or embolization. Preserved renal functions of the embolized kidneys were identified by using enhanced CT. Results: Cases of surgery and embolization were 37 and 13, respectively: 5 and 4 in renal injury grade III, 17 and 6 in grade IV and 13 and 3 in grade V. Cases of surgery and embolization were 33 and 1 before 2000 and 2 and 12 after 2000, repectively: embolizations increased after 2000. No significant differences in mean diastolic pressure, hemoglobin, hospital days and complications existed between the surgery and the embolization groups (p>0.05). However, the transfusion volume was significantly smaller in the embolization group (p<0.05). One postoperative complication occurred in the surgery group. We identified the preserved renal functions of the embolized kidney by using enhanced CT. Conclusion: Embolization could be one treatment method for high-grade renal injury. Thus, we might suggest selective embolization a useful method for preserving the renal function in cases of high-grade renal injury.

Analysis of Urban Traffic Network Structure based on ITS Big Data (ITS 빅데이터를 활용한 도시 교통네트워크 구조분석)

  • Kim, Yong Yeon;Lee, Kyung-Hee;Cho, Wan-Sup
    • The Journal of Bigdata
    • /
    • v.2 no.2
    • /
    • pp.1-7
    • /
    • 2017
  • Intelligent transportation system (ITS) has been introduced to maximize the efficiency of operation and utilization of the urban traffic facilities and promote the safety and convenience of the users. With the expansion of ITS, various traffic big data such as road traffic situation, traffic volume, public transportation operation status, management situation, and public traffic use status have been increased exponentially. In this paper, we derive structural characteristics of urban traffic according to the vehicle flow by using big data network analysis. DSRC (Dedicated Short Range Communications) data is used to construct the traffic network. The results can help to understand the complex urban traffic characteristics more easily and provide basic research data for urban transportation plan such as road congestion resolution plan, road expansion plan, and bus line/interval plan in a city.

  • PDF

Statistical approach for development of objective evaluation method on tobacco smoke

  • Hwang, Keon-Joong;Rhee, Moon-Soo;Ra, Do-Young
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.22 no.2
    • /
    • pp.184-189
    • /
    • 2000
  • This study was conducted to develop the objective evaluation method for tobacco smoke. The evaluation was carried out by using the data of cut or blended tobacco components, smoke components, electric nose system (ENS), and sensory test. By using the statistical methods, such as cluster analysis, discriminant analysis, factor analysis, correlation analysis, and multiple regression analysis, the relationship among the data of tobacco, smoke, ENS, and sensory evaluation was studied. By the results of cluster analysis, the data from smoke analysis by GC and ENS were able to select the difference of tobacco leaf characteristics. As the results of discriminant analysis, grouping by the components of tobacco leaves and smoke was possible and the results of GC analysis of smoke could be used for discrimination of tobacco leaves. In the results of factor analysis, nicotine, tar, CO, puff No and pH in the smoke were the factors effecting on the tobacco leaf characteristics. From the correlation analysis, aroma, taste, irritation, and smoke volume of sensory test had high relation to tar, p-cresol threonolatone, levoglucosane, and quinic acid- ${\gamma}$ -lactone of smoke. The ENS data showed high efficiency for discriminant analysis and cluster analysis, but it was not good for factor analysis, and correlation analysis. It was possible to estimate tobacco leaves and their blending characteristics by the analytical data of tobacco leaves, smoke, ENS, and sensory test results. By the multiple regression analysis, some correlation among selected chemical components and sensory evaluation were found. This study strongly indicated that the some chemical analysis data was available for the objective evaluation of tobacco sensory attributes.

  • PDF

A Study on the Kinetics and the Biogas Formation for Organic Wastewater Treatment in Anaerobic Fluidized-Bed Bioreactor and New Model AFPBBR (혐기성 유동층 생물 반응기와 새로운 모델의 AFPBBR에서 유기성폐수 처리시 Biogas 생성과 반응상수에 관한 연구)

  • 김재우;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.2
    • /
    • pp.23-33
    • /
    • 1993
  • The anaerobic digestion of organic synthetic wastewater in anaerobic fluidized bed bioreactor (AFBBR) and anaerobic fluidized packed bed bioreactor (AFPBBR) was studied. This study was conducted to evaluate efficiency and reliability of two reactor. Experiment was performed to find the effect of upflow rate with AFBBR and the height of packed bed with AFPBBR. As a result, this program obtained several conclusion. These are given as follows: As applied the upflow rate increased in AFBBR the produced volume of biogas increased, while the gas production and COD removal decreased at above 0.3 m$^3$/h. When a upflow rate is 0.4 m$^3$/h in AFBBR the volatile suspended solid (VSS) became significantly increased. At an organic loading rate from 0.1 to 0.4 of upflow rate in AFBBR, the methane yield was 1.5584 m$^3$CH$_4$/kgCOD removed, and the observed cell yield coefficient was 0.0933 gVSS/gCOD. In case of AFPBBR, the results showed also that 20 cm of height of packed bed was superior to other in the aspect ot biogas production, the content of methane and COD removal. At 20 cm of height, the profile of microorganisms was stable, while at 30 cm the VSS of effluent became higher than AFBBR. Though COD removal of AFPBBR increased with packed bed, COD removal deteriorate with over packing because the loss of pressure became higher in the reactor. At an organic loading rate from 20 to 40 cm of packed bed in-AFPBBR, the methane yield was 2.5649 m$^3$CH$_4$/kgCOD removed, and the observed cell yield coefficient was 0.0506 gVSS/gCOD. Based upon the results obtained, it is suggested that AFBBR and AFPBBR is the most effective conditions at 0.3 m3/h of upflow rate, the 20cm of packed bed, respectively. The rate constant are summarized as follow:

  • PDF

Applicability of the SBR Process Using Aerobic Granular Sludge (AGS) in Municipal Wastewater Treatment (호기성 그래뉼 슬러지를 이용한 연속 회분식 공정의 도시하수처리에 대한 적용)

  • Yae, Jae-Bin;Ryu, Jae-Hoon;Hong, Seong-Wan;Kim, Hyun-Gu;Ahn, Dae-Hee
    • Journal of Environmental Science International
    • /
    • v.27 no.4
    • /
    • pp.233-240
    • /
    • 2018
  • The purpose of this study was to confirm the applicability of aerobic granular sludge (AGS) in the advanced sewage treatment process. Simulated influent was used in the operation of a laboratory scale reactor. The operation time of one cycle was 4 h and the reactor was operated for six cycles per day. The volume exchange ratio was 50%. The influent was injected in divisions of 25% to increase the removal efficiency of nitrogen in every cycle. As a result, the removal efficiencies of $COD_{Cr}$ and TN in this reactor were 98.2% and 76.7% respectively. During the operation period, the AGS/MLVSS concentration ratio increased from 70.0% to 86.7%, and the average $SVI_{30}$ was 67 mL/g. The SNR and SDNR were 0.073-0.161 kg $NH_4{^+}$-N/kg MLVSS/day and 0.071-0.196 kg $NO_3{^-}$-N/kg MLVSS/day respectively. These values were higher or similar to those reported in other studies. The operation time of the process using AGS is shorter than that of the conventional activated sludge process. Hence, this process can replace the activated sludge process.

Breakthrough behaviour of NBC canister against carbon tetrachloride: a simulant for chemical warfare agents

  • Srivastava, Avanish Kumar;Shah, D.;Mahato, T.H.;Singh, Beer;Saxena, A.;Verma, A.K.;Shrivastava, S.;Roy, A.;Yadav, S.S.;Shrivastava, A.R.
    • Carbon letters
    • /
    • v.13 no.2
    • /
    • pp.109-114
    • /
    • 2012
  • A nuclear, biological, chemical (NBC) canister was indigenously developed using active carbon impregnated with ammoniacal salts of copper (II), chromium (VI) and silver (I), and high efficiency particulate aerosol filter media. The NBC canister was evaluated against carbon tetra chloride ($CCl_4$) vapours, which were used as a simulant for persistent chemical warfare agents under dynamic conditions for testing breakthrough times of canisters of gas masks in the National Approval Test of Respirators. The effects of $CCl_4$ concentration, test flow rate, temperature, and relative humidity (RH) on the breakthrough time of the NBC canister against $CCl_4$ vapour were also studied. The impregnated carbon that filled the NBC canister was characterized for surface area and pore volume by $N_2$ adsorption-desorption isotherm at liquid nitrogen temperature. The study clearly indicated that the NBC canister provides adequate protection against $CCl_4$ vapours. The breakthrough time decreased with the increase of the $CCl_4$ concentration and flow rate. The variation in temperature and RH did not significantly affect the breakthrough behaviour of the NBC canister at high vapour concentration of $CCl_4$, whereas the breakthrough time of the NBC canister was reduced by an increase of RH at low $CCl_4$ vapour concentration.

Design and Effectiveness Analysis of prefabricated Storage-type infiltration facility (조립식 저류형 침투시설의 설계 및 공간적용 효과분석)

  • Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: This study has developed economical and environmentally friendly storage type infiltration facilities that securing storage space inside the infiltration facility. It focused on preventing flooding rainfall as well as securing more groundwater through rainwater infiltration that is valuable for the dry season. In addition, this study compares the installation cost of the storage-type infiltration facility to the cost of the conventional rainwater management facilities to demonstrate the economic efficiency of the storage-based infiltration facility. Method: Unit infiltration of this facility is calculated and when it was applied to a certain capacity, the amount of countermeasures are proposed in case study. Result: Unit infiltration of it is $0.2541m^3/hr$ and un it Temporary storage of it is $1.054m^3/m$. As a result, the infiltration effect of this facility is $1.306m^3/hr$. The cost was approximately 30% reduction in time to apply the storage type infiltration facility as compared with the case to apply the existing penetration of the facilities. Since the penetration of the existing facilities is smaller than that and it has much securing volume to process the same the amount of countermeasures. Therefore, it is determined that the cost significantly increases in material cost part. On the other hand, storage type infiltration facility is installed a small quantity because Unit Temporary storage and infiltration are bigger than that. So, it occurred to reduce material and installation costs.

Strategies for Improving Forest Work Team Management (산림작업(山林作業) 영림단(營林團) 운영개선(運營改善) 방안(方案)에 관한 연구(硏究))

  • Kang, Gun-Uh
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.3 s.160
    • /
    • pp.153-160
    • /
    • 2005
  • This study was analyze the performance of Forest Work Team from 1999 to 2003. Following recommendations were come up by reviewing the performance of Forest Work Team. The volume of forest works should be increased in order to supply the constant daily work. This would provide the increase of their salary and maintain their salary and maintain their livelihood. The Forest Work Teams should be the members of registered business with highly trained manpower. Qualified Work Team should have extra financial incentive by comparing with general forest workers who did not have adequate skills. The percentage of the certified forest workers should be increased by providing the technical training. To increase the efficiency of forest work, the forest mechanization should be accomplished and the training of forest mechanization had to be offered regularly for the forest workers, and provided them with an education allowance.