• 제목/요약/키워드: Volume Efficiency

검색결과 2,143건 처리시간 0.031초

고수부지에 조성한 수질정화 여과습지의 초기운영단계 총인 제거 (Total Phosphorus Removal Rate of a Subsurface-Flow Wetland System Constructed on Floodplain During Its Initial Operation Stage)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제6권6호
    • /
    • pp.49-55
    • /
    • 2003
  • Total phosphorous removal rate was examined of a subsurface-flow treatment wetland system which was constructed on floodplain in the down reach of the Kwangju Stream in Korea from May to June 2001. Its dimensions were 29 meter in length, 9 meter in width and 0.65 meter in depth. A bottom layer of 45 cm in depth was filled with crushed granite with about 15~30 mm in diameter and a middle layer of 10 cm in depth had pea pebbles with about 10 mm in diameter. An upper layer of 5 cm in depth contained course sand. Reeds(Phragmites australis) were transplanted on the surface of the system. They were dug out of natural wetlands and stems were cut at about 40 cm height from their bottom ends. Water of the Kwangju Stream flowed from a submerged dam into it via a pipe by gravity flow and treated effluent was funneled back into the Stream. The number of reed stems increased from 80 stems/$m^2$ in July 2001 to 136 stems/$m^2$ in September 2001. The hight of stems was 44.2 cm in July 2001 and 75.3 cm in September 2001. The establishment of reeds at early operating stage of the system was good. Volume and water quality of inflow and outflow were investigated from July 2001 through December 2001. The average inflow was 40 $m^3$/day and hydraulic detention time was about 1.5 days. The concentration of total phosphorous n influent and effluent was 0.83 and 0.33 mg/L, respectively. The removal rate of total phosphorous averaged about 60%. The removal efficiency was slightly higher, compared with that of subsurface-flow wetlands operating in North America, whose retention rate of total phosphorous was reported to be about 56%. The good abatement rate could be attributed to sedimentation of particle phosphorous in pores of the media and adsorption of phosphorous to the biofilm developed on the surface of them. Increase of standing density of reeds within a few years will develop root zones which may lead to increment in the phosphorous retention rate.

활성탄소의 불소화가 크롬이온 흡착에 미치는 영향 (Effects of the Fluorination of Activated Carbons on the Chromium Ion Adsorption)

  • 김민지;정민정;최석순;이영석
    • 공업화학
    • /
    • 제26권1호
    • /
    • pp.92-98
    • /
    • 2015
  • 본 연구에서는 페놀계 활성탄소를 다양한 불소 분압(0.01~0.03 MPa)으로 불소화를 실시하였으며, 불소화된 활성탄소의 6가 크롬 흡착 특성을 조사하였다. BET와 XPS 결과로부터, 불소화 처리된 활성탄소는 비표면적 및 총 기공부피가 각각 24.7, 58.8% 증가되었으며, 활성탄소 표면에 불소 관능기가 도입됨을 알 수 있었다. 불소 분압이 0.02 MPa일 때, 크롬이온 흡착에 최적화된 표면처리 조건임을 확인하였다. 또한, 초기농도 300 mg/L에서 98%의 제거효율을 나타내었으며, 이러한 결과는 미처리 활성탄소와 비교하여 약 3배 증가됨을 알 수 있었다. 한편, 불소화된 활성탄소의 크롬이온 흡착은 미처리 활성탄소와 대조적으로 30 min 이내에 완료되었으며, 이러한 현상은 페놀계 활성탄소의 표면에서 크롬 이온과의 친화성 증가에 의한 것으로 판단되었다.

새집증후군 유발 벤젠가스 흡착에 미치는 활성탄소섬유의 함산소불소화 영향 (Effect of Oxyfluorination of Activated Carbon Fibers on Adsorption of Benzene Gas Causing Sick House Syndrome)

  • 임형순;김민지;공은영;정진도;이영석
    • 공업화학
    • /
    • 제29권3호
    • /
    • pp.312-317
    • /
    • 2018
  • 본 연구에서는 새집증후군 원인가스 중 하나인 벤젠 가스 흡착특성을 향상시키기 위하여 활성탄소섬유에 함산소불소화 처리를 실시하였다. 함산소불소화 처리된 활성탄소섬유 표면특성 및 기공특성은 X-선광전자분광기(XPS)와 Brunauer-Emmett-Teller (BET) 분석을 통해 확인하였으며, 벤젠 가스 흡착 특성은 가스크로마토그래피(GC)로 평가하였다. XPS 결과로부터 불소분압이 증가함에 따라 활성탄소섬유 표면의 불소관능기가 증가함을 알 수 있었다. 함산소불소화 처리 후 모든 샘플의 비표면적은 감소하였으나, 불소 분압이 0.1 bar일 때 그 미세기공 부피비가 증가하였다. 함산소불소화 처리된 활성탄소섬유는 11 h 동안 100 ppm의 벤젠 가스를 모두 흡착하였으며, 이는 미처리 활성탄소섬유와 비교하여 벤젠 가스 흡착효율이 약 2배 향상됨을 알 수 있었다.

활성탄관을 사용하여 포집한 작업환경 공기중 아크릴아마이드의 분석법 (Simple Analytical Method for Acrylamide in the Workplace Air Adsorbed by Charcoal Tube)

  • 양정선;이미영;박인정;강성규
    • 분석과학
    • /
    • 제11권2호
    • /
    • pp.139-144
    • /
    • 1998
  • 아크릴아마이드를 생산하는 공장에서, 근로자가 노출될 가능성이 있는 아크릴아마이드의 양을 평가하기 위하여, 작업환경 시료의 포집과 이에 대한 탈착, 분석조건을 검토하였다. 작업 환경 중 시료 채취를 위한 흡착제로서 활성탄관을 사용하고, 이를 아세톤으로 추출하였을 때 87%의 탈착효율을 나타내었다. 불꽃이온화 검출기가 부착된 가스크로마토그라피로 분석한 경우 검출한계는 0.814 mg/L였고, 이를 40L의 작업환경 공기중 농도로 환산하면 $0.0203mg/m^3$이다. 따라서 산업보건 관련 실험실에 일반화 되어있는 불꽃이온화 검출기(Flame Ionization Detector, FID)를 사용하여도, 아크릴아마이드 허용농도 $0.3mg/m^3$(OSHA, PEL) 내외의 시료를 적절한 감도로 분석이 가능하다. 그러므로 기존의 분석방법으로 알려진 질소, 인 검출기(Nitrogen Phosphorous Detector, NPD)를 사용하지 않아도 아크릴아마이드를 신속하고 경제적으로 분석할 수 있을 것으로 생각된다.

  • PDF

다공성 세라믹관내에서 생성되는 수중 유전체 장벽 방전 플라즈마를 이용한 아나톡신-a의 분해 (Decomposition of Aqueous Anatoxin-a Using Underwater Dielectric Barrier Discharge Plasma Created in a Porous Ceramic Tube)

  • 조진오;좌은진;목영선
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.167-177
    • /
    • 2016
  • This work investigated the decomposition of aqueous anatoxin-a originated from cyanobacteria using an underwater dielectric barrier discharge plasma system based on a porous ceramic tube and an alternating current (AC) high voltage. Plasmatic gas generated inside the porous ceramic tube was uniformly dispersed in the form of numerous bubbles into the aqueous solution through the micro-pores of the ceramic tube, which allowed an effective contact between the plasmatic gas and the aqueous anatoxin-a solution. Effect of applied voltage, treatment time and the coexistence of nutrients such as $NO_3{^-}$, $H_2PO_4{^-}$ and glucose on the decomposition of anatoxin-a was examined. Chemical analyses of the plasma-treated anatoxin-a solution using liquid chromatography-mass spectrometry (LC-MS) and ion chromatography (IC) were performed to elucidate the mineralization mechanisms. Increasing the voltage improved the anatoxin-a decomposition efficiency due to the increased discharge power, but the energy required to remove a given amount of anatoxin-a was similar, regardless of the voltage. At an applied voltage of 17.2 kV (oxygen flow rate: $1.0L\;min^{-1}$), anatoxin-a at an initial concentration of $1mg\;L^{-1}$ (volume: 0.5 L) was successfully treated within 3 min. The chemical analyses using LC-MS and IC suggested that the intermediates with molecular weights of 123~161 produced by the attack of plasma-induced reactive species on anatoxin-a molecule were further oxidized to stable compounds such as acetic acid, formic acid and oxalic acid.

고속여과의 효과에 관한 연구 (Study of High Rate Filter.)

  • 박인규
    • 물과 미래
    • /
    • 제10권2호
    • /
    • pp.91-100
    • /
    • 1977
  • This is an experimental study to raise higher efficiency of filteration than conve ntional filteration by increasing of filteration capacity for per unit area and by extending of filteration lasting time with biflow filter system which was improved from the conventional rapid sand filteration method in the process of water purification treatment. In order to raise more efficient function of filteration and giving consideration to the filter layer at upper and lower parts of the filter, the fine sand & an thracite were used as a filter medium. Although there is some difficulty than previous fine sand in procurement, it could confirm that such filter medium (fine sand & anthracite) was more effective in the field of load, lasting time and back wash, etc. In consideration of practical effect of filteration. The raw water which was used for this experimental study was not coagulated. As a result of this experiment, the filteration volume could increase more than 2 times than that of conventional method. Besides, much more advantages could be obtained for instance, the requirement of installation area was not much and installation cost could economize. On the other hand, the following results were found. The quality of filtered water became worse as time goes by and the turbidity of filtered water was more influenced by raw water turbidity than by rate of filteration. Lasting time of filteration on change of filteration rate in the filter layer reached 2 times in comparison with previous filter basin, and until loss gead reached to 1.0 meter and 1.5 meter, the following relate formulas between lasting time and rate of filteration were formed. ($T_{1.5}=181.96V^{-0.46},\;T_{1.0}=121.31V^{-0.46}$) Even though the lasting time can be shorten in case of the increase of the filteration rate, but the lasting time was prolonged more than 2 times than of previous method. With taking aim at contribution to the development of water treatment technique, we are planning to study continuously for the future study basing on the results in this papers.

  • PDF

상수도 요금 과징업무 기계화 처리에 대하여 (A study on EDP of water Rate Billing procedures)

  • 정규영
    • 물과 미래
    • /
    • 제7권2호
    • /
    • pp.11-22
    • /
    • 1974
  • Comparing with Seoul city's other administrative works, the work to arrange and collect monthly water rates with 470,000 faucets is tremendous in volume and simple repetition in quality. In order to cover the shortage of handling, it is urgent for us to replace the present manual system with EDP(Electronic Data Processing) system to mechanize a series of handling works of simple repeated calculation such as water consumption, rate calculation, statistics arrangement, bills and specification of water rate by computer. When this work is completely mechanized, inspectors of water meter just turn over their checking results to the Data Center and all data are processed through Input Media(OMR Card, Punched Card) and computer for programming final bills. Then, the delivery of the bills to citizens will be the only work to be carried out. such mechanization will bring about the following benefits: 1. Improvement of administrative work by efficiency and rationalization. 2. Improvement of administrative service with people. 3. Possibility of scientific with trustworthy multi-purpose policy-making data. 4. An effect to cover the personnel shortage of 252 persons (at all the water works offices) and save manpower of 166 persons (47,619 man-days). The application of the above mentioned mechanization will be started to only Chongro and Chung-ku water works offices as model cases out of all water works offices in Seoul. As the electronic calculating machines are inducted, this system will be gradually applied to other water works offices. The billing and collection works of water rates which are connected directly to the daily life of the citizenes, should be handled by the scientific EDP system as soon as possible in order to promote the convenience of consumers and effective operation. This study is to promote the sound and rational operation of this work.

  • PDF

UWB위치인식 시스템의 야드 크레인 적용 (Applying Ultra-WideBand Location System to Yard Crane)

  • 박대헌;강범진;박장우;조성언
    • 한국항행학회논문지
    • /
    • 제12권3호
    • /
    • pp.215-219
    • /
    • 2008
  • 최근 물류의 양이 증가함에 따라 컨테이너를 사용한 해상 물동량이 급격히 증가되어 부두에서 처리하여야할 컨테이너 양이 많이 증가되었다. 이에 항만에서의 물류비용 절감을 위해 항만 자동화에 관한 관심이 증대되고 있다. 항만의 자동화는 선박에서 컨테이너를 운반할 트레일러가 통과하는 RFID를 이용한 게이트의 자동화, 정박한 선박에 실려 있는 화물을 취급하는 Quay-Side 컨테이너 크레인(QC)의 자동화, 야드에서 컨테이너를 이적하는 갠트리크레인(GC), 게이트 사이에서 컨테이너를 수송하는 컨테이너 트랜스 포터의 자동화로 크게 분류할 수 있다. 부두의 운용 효율을 증가시키기 위해서는 야드 크레인의 정확한 위치 검출이 상당히 중요한 과제이다. 본 논문에서는 UWB위치인식 시스템을 적용한 야드 크레인의 자동화에 대하여 논의하고 개발방향을 제안한다.

  • PDF

K개의 점 데이터를 포함하는 최소MBR 탐색 (Finding the Minimum MBRs Embedding K Points)

  • 김건우;김영훈
    • 정보과학회 논문지
    • /
    • 제44권1호
    • /
    • pp.71-77
    • /
    • 2017
  • 스마트폰과 같은 GPS센서가 장착된 모바일 기기가 널리 보급되고 있다. 이러한 추세에 따라 트위터나 페이스북과 같은 소셜 미디어에서 GEO태그가 된 메시지 (즉, GPS 위치를 갖는 멀티미디어 메시지)를 손쉽게 작성할 수 있게 되었고 게시자의 위치정보를 포함하는 공간데이터가 급증하고 있다. 그러나 이러한 공간데이터에서 항상 위치 정보와 게시글 내용이 명시적인 연관성을 갖고 있지는 않다. 때문에 키워드와 위치정보 분포의 관련성에 따라 검색결과를 재구성할 필요가 있다. 우리는 크기가 가장 작은 k개의 점 데이터를 포함하는 최소경계사각형(MBR)을 찾음으로써 데이터가 가장 밀집된 사각형을 찾으며, 이는 위치 검색시스템에서 유용하게 사용될 수 있다. 본 논문은 최소경계사각형과 같이 거리가 가까운 2차원 공간데이터의 묶음을 찾기 위해 효율적인 알고리즘을 제안하였고 합성데이터와 실제 데이터를 이용한 실험을 통해 알고리즘의 효율성을 검증하였다.

극대용량 서지 링크드 데이터 구축의 효율성을 위한 RDF 트리플 저장소 접근 최소화에 관한 연구 (Research on Minimizing Access to RDF Triple Store for Efficiency in Constructing Massive Bibliographic Linked Data)

  • 이문호;최성필
    • 한국도서관정보학회지
    • /
    • 제48권3호
    • /
    • pp.233-257
    • /
    • 2017
  • 본 논문에서는 세계 최대 규모의 생의학 분야 서지 데이터베이스인 MEDLINE 전체를 링크드 데이터로 변환 구축하는 효율적인 방안을 제시한다. 이를 위해서 우선 MEDLINE 레코드 구조를 세부적으로 분석하여 적합한 RDF 스키마를 도출하고 각 레코드를 도출된 스키마에 유효한 RDF 파일로 변환하는 과정을 거친다. 본 논문에서는 변환된 레코드 단위의 모든 RDF 파일을 병합하여 이를 단일 RDF 트리플 저장소에 저장할 때 주어 URI 중복 확인 절차를 효율화하는 이중 일괄 등록 방법을 적용한다. 이 방법을 통해서 RDF 파일 단위로 링크드 데이터를 순차적으로 구축하는 방법과 비교했을 때 주어 URI 중복 제거를 위한 RDF 트리플 저장소 접근 횟수가 26,597,850회에서 2,400회로 감소하는 결과를 가져왔다. 따라서 본 연구의 결과는 대용량 서지 레코드 집합을 링크드 데이터로 변환하는 과정에서의 비효율성을 제거하고 신속성과 시의성을 확보할 수 있는 중대한 계기를 제공할 것으로 기대한다.