• Title/Summary/Keyword: Volume Duration

Search Result 472, Processing Time 0.031 seconds

A Study on the Optimum Scheme for Determination of Operation Time of Line Feeders in Automatic Combination Weighers

  • Keraita James N.;Kim Kyo-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1567-1575
    • /
    • 2006
  • In an automatic combination weigher, the line feeders distribute the product to several weighing hoppers. The ability to supply appropriate amount of product to the weighing hoppers for each combination operation is crucial for the overall performance. Determining the right duration of operating a line feeder to supply a given amount of product becomes very challenging in case of products which are irregular in volume or specific gravity such as granular secondary processed foods. In this research, several schemes were investigated to determine the best way for a line feeder to approximate the next operating time in order to supply a set amount of irregular goods to the corresponding weighing hopper. Results obtained show that a weighted least squares method (WLS) employing 10 data points is the most effective in determining the operating times of line feeders.

A Basic Experimental Study on Potential Operating Range in Gasoline Direct-Injection Compression Ignition (GDICI) Engine (가솔린 직접분사식 압축착화 엔진의 가능한 운전영역에 관한 기초실험 연구)

  • Cha, Junepyo;Yoon, Sungjun;Lee, Seokhwon;Park, Sungwook
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.33-35
    • /
    • 2013
  • The present work is an experimental investigation on potential operating range using directly injected gasoline fuel in a single-cylinder compression ignition (CI) engine. The objectives of present study were to apply auto-ignited combustion to gasoline fuel and to evaluate potential operating range. In order to auto-ignite gasoline fuel in CI engine, the fuel direct-injection system and the intake air system were modified that a flow rate and temperature of intake air were regulated. The heat-release rate (HRR), net indicated mean effective pressure (IMEP), start of combustion (SOC), and combustion duration were derived from in-cylinder pressure data in a test engine, which has 373.33cc displacement volume and 17.8 compression ratio. The exhaust emission characteristics were obtained emission gas analyzer and smoke meter on the exhaust line system.

  • PDF

A Study on an Improvement of the Ignitability Using the High Frequency Ignition System (고주파점화장치를 사용한 착화성 향상에 관한 연구)

  • Lee, Jung-Sun;Gang, Byeong-Mu;Ha, Jong-Ryul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.359-368
    • /
    • 1996
  • For fuel economy and pollutant reduction, the interests in lean burn has increased recently. The purpose of this research is to develop a High Frequency Ignition System (HIS) that can make powerful ignition. We studied relations between performance of HIS and probability of inflammation under various ignition conditions. It is concluded that the portion of capacitance energy to the total energy is comparatively larger and that the optimum spark interval and spark duration are dependent upon conditions of Constant Volume Combustion Chamber.

An Experimental Study on Low-Temperature Behavior of Stratified Fluids in a Square Cavity with Upper Cooling Surface (상부에 냉각면이 있는 정방형내 이종유체의 저온거동에 관한 실험적 연구)

  • Lee, D.S.;Kim, B.C.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.55-62
    • /
    • 2000
  • An experimental study on the stratified fluids with water and silicon oil of same volume in the cavity with upper cooling surface was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in a square cavity. The experiments were performed with variation of initial temperature and cooling surface temperature. The temperature drop of oil was faster than that of water and freezing was initiated from the interface of oil and water and propagated downward. For the water above $4^{\circ}C$, the cooling rate was faster than that below $4^{\circ}C$ and showed almost same temperature distribution but for the water that of below $4^{\circ}C$, it showed the stable stratified temperature distribution. The lower the initial temperature and the higher the cooling surface temperature was, the longer the supercooling duration.

  • PDF

Damage progression study in fibre reinforced concrete using acoustic emission technique

  • Banjara, Nawal Kishor;Sasmal, Saptarshi;Srinivas, V.
    • Smart Structures and Systems
    • /
    • v.23 no.2
    • /
    • pp.173-184
    • /
    • 2019
  • The main objective of this study is to evaluate the true fracture energy and monitor the damage progression in steel fibre reinforced concrete (SFRC) specimens using acoustic emission (AE) features. Four point bending test is carried out using pre-notched plain and fibre reinforced (0.5% and 1% volume fraction) - concrete under monotonic loading. AE sensors are affixed at different locations of the specimens and AE parameters such as rise time, AE energy, hits, counts, amplitude and duration etc. are obtained. Using the captured and processed AE event data, fracture process zone is identified and the true fracture energy is evaluated. The AE data is also employed for tracing the damage progression in plain and fibre reinforced concrete, using both parametric- and signal- based techniques. Hilbert - Huang transform (HHT) is used in signal based processing for evaluating instantaneous frequency of the acoustic events. It is found that the appropriately processed and carefully analyzed acoustic data is capable of providing vital information on progression of damage on different types of concrete.

A study on shrinkage deformation according to injection molding conditions of pipe (annular) shaped products (파이프(Annular) 형상 제품의 사출성형 조건에 따른 수축 변형에 관한 연구)

  • Jeon, Dae-Seon
    • Design & Manufacturing
    • /
    • v.15 no.2
    • /
    • pp.36-41
    • /
    • 2021
  • The 3 dimensional Pipe (Annular) Shaped Products was selected as a test sample, then a attribute of a molding shrinkage according to the parameters of a injection process was examined with PC, which is the typical engineering plastic. Both the inside and the outside diameter of the Pipe (Annular) sample were shrank into the inner direction of the part. And then the comparative analysis of the samples proved that a increasing thickness led a bigger shrinkage rate in the equal outside diametric samples, and a decreasing outside diameter caused a bigger shrinkage rate in the same thickness samples. The comparative study of the cushion volume of a injection machine showed that the molding shrinkage was most affected by the pressure strength among the resin temperature, the maintenance pressure strength and the maintenance pressure duration time. Each of the shrinkage rates according to the measuring direction and the gate position was different. As a result, the injection molded sample had not a typical circular shape.

Treatment Outcome of Gamma Knife Radiosurgery for GH-Secreting Pituitary Tumors (성장호르몬 분비 뇌하수체선종에 대한 감마나이프 방사선수술의 치료결과)

  • Lim, Young Jin;Choi, Yeong Ho;Leem, Won;Lee, Ki Taek;Koh, Jun Seok;Kim, Tae Sung;Kim, Gook Ki;Rhee, Bong Arm
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.5
    • /
    • pp.567-574
    • /
    • 2001
  • Objective : As for growth hormone(GH) secreting pituitary adenoma, it's remission should be declared on the basis of satisfactory controlling of the tumor, normalization of hormonal level, and symptomatic improvement of the patient. Several modalities of treatment have been applied and administered, and yet, this disease still remains as inveterate one to be fully treated. The purpose of this study is to evaluate the outcome of gamma knife radiosurgery(GKRS) for GH secreting pituitary adenoma, and to identify various factors affecting the outcome of the treatment. Method : A group of 24 out of 35 patients, treated by Leksell gamma knife unit during the period of March of 1992 through October of 1997, had been observed for more than two years. The mean target volume of microadenoma was $449.3mm^3(range 216-880mm^3)$, and that of macroadenoma was $3183.1mm^3(range 1456-13125mm^3)$. The tumor margin was covered with 50% isodose profile, and mean marginal dose was 25.2Gy(range 15-32.4Gy). The mean number of isocenter was 4.3(range 1-6). The exposed dose to the optic apparatus was less than 8Gy. The mean follow-up period was 37.8months(range 24-102months). Result : No patients showed any increase in the tumor volume during the follow-up period. And definite shrinkage of tumor volume(tumor volume reduction rate, TVRR : more than 50%) was obtained in 10 patients(41.7%). Twenty one patients(87.5%) had reduced hormonal level compared than pre-treatment level. Among them, normalization of the hormonal level was achieved in 12 patients(50%). Clinicoendocrinological remission was seen in 3 patients (12.5%). According to the results of statistical analysis, tumor volume(p=0.016),duration of symptoms(p=0.046), initial GH level(p=0.017), and the invasion of cavernous sinus(p=0.036) were significantly favorable to post-radiosurgical outcome. The TVRR was significantly related to post-radiosurgical reduction of serum GH level. Permanent complication was not seen. Conclusion : The authors concluded that GKRS is a safe and effective treatment modality for acromegaly. To otain the better outcome of GKRS in GH secreting pituitary adenoma, more careful and sophisticated treatment-planning is recommended.

  • PDF

Palliative Irradiation Using Helical Tomotherapy in Recurrent Pelvic Tumors with Prior Radiotherapy (방사선치료 후 재발한 골반암에서 토모테라피를 이용한 고식적 재치료)

  • Kay, Chul-Seung;Yoo, Eun-Jung;Kim, Ji-Hoon;Ro, Duck-Young;Kim, Ki-Jun
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.133-140
    • /
    • 2010
  • Purpose: We retrospectively investigated the effect of irradiation using helical tomotherapy in recurrent pelvic tumors that underwent prior irradiation. Materials and Methods: Fourteen patients with recurrent pelvic tumors consisting of rectal cancer (57.1%), cervical cancer (35.7%) and cancer with an unknown origin (7.1%) were treated with tomotherapy. At the time of irradiation, median tumor size was 3.5 cm and 7 patients complained of pain originating from a recurrent tumor. The median radiation dose delivered to the gross tumor volume, clinical target volume, and planning target volume was 50 Gy, 47.8 Gy and 45 Gy, respectively and delivered at 5 fractions per week over the course of 4 to 5 weeks. Treatment response and duration of local disease control were evaluated using the Response Evaluation Criteria in Solid Tumors (ver. 1.0) and the Kaplan-Meyer method. Treatment-related toxicities were assessed through Common Terminology Criteria for Adverse Events (ver. 3.0). Results: The median follow-up time was 17.3 months, while the response rate was 64.3%. Symptomatic improvement appeared in 6 patients (85.7%). The median duration time of local disease control was 25.8 months. The rates of local failure, distant failure, and synchronous local and distant failure were 57.1%, 21.4%, and 7.1%, respectively. Acute toxicities were limited in grade I or II toxicities, except for one patient. No treatment related death or late toxicity was observed. Conclusion: Helical tomotherapy could be suggested as a feasible palliative option in recurrent pelvic tumors with prior radiotherapy. However, to increase treatment effect and overcome the limitation of this outcome, a large clinical study should be performed.

Sister chromatid exchange in peripheral lymphocytes of radiation exposed workers in a hospital (방사선 직업 종사자의 자매염색분체교환)

  • Hong, Hae-Sook;Na, Yeon-Kyung;Ha, Sun-Ok;Lee, Jeong-Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.2 no.2
    • /
    • pp.90-101
    • /
    • 2000
  • This study is being carried out, in two different random sample groups, between 20 men who were radiation exposed workers in the two general hospitals located in "T" city as a experimental group and 20 healthy men who were non-radiation exposed workers as a control group. The occurring frequency of the sister chromatid exchange as a biological dosemeter of radiation were studied. And the age, duration of employment and smoking were used as variable for the experiment. The results are as follows : The frequency of SCE were noticed respectively by each variable : 1) by age as a variable, the frequency were increased notably in radiation exposed workers group rather than a control group(p<0.05). 2) by duration of employment, the difference of the frequency were not recognised significantly in statistical among radiation exposed workers. 3) in smoker the frequency were increased notably in a radiation exposed workers than a control groups(p<0.05). Taking into consideration the above results, the age and smoking could affect the frequency of SCE, however, the size of sample were too small to generalize. Therefore, the following suggestions are recommended to get more accurate result. 1) In order to clarify the correlation in a smoking as variable, finding the volume of smoking and its related factor are necessarily required. 2) In order to confirm the correlation in each variable, adopting of a bigger-sized sample are needed and the study itself also be carried out repeatedly.

  • PDF

An Aerodynamic study used aerophone II for snoring patients (코콜이 환자의 sleep splint 착용 전후의 음향학적 및 공기역학적 연구)

  • Jung, Se-Jin;Kim, Hyun-Gi;Shin, Hyo-Keun
    • The Journal of the Korean dental association
    • /
    • v.49 no.4
    • /
    • pp.219-226
    • /
    • 2011
  • Snoring and obstructive sleep apnea (OSA) are common sleep disordered breathing conditions. Habitual snoring is caused by a vibration of soft tissue of upper airway while breath in sleeping, and obstructive sleep apnea is caused by the repeated obstructions of airflow for a sleeping, specially airflow of pharynx. Researchers have shown that snoring is the most important symptom connected with the obstructive sleep apnea syndrome The treatment is directed toward improving the air flow by various surgical and nonsurgical methods. The current surgical procedures used are uvulopalatopharyngoplasty(UPPP), orthognathic surgery, nasal cavity surgery. Among the nonsurgical methods there are nasal continuous positive air pressure(CPAP), pharmacologic therapy. weight loss in obese patient, oral appliance(sleep splint). Sleep splint brings the mandible forward in order to increase upper airway volume and prevents total upper airway collapse during sleep. However, the precise mechanism of action is not yet completely understood, especially aerodynamic factor. The aim of this study evaluated the effect of conservative treatment of snoring and OSAS by sleep splint through measured aerodynamic change by an aerophone II. We measured a airflow, sound pressure level, duration, mean power from overall airflow by aerophone II mask. The results indicated that on a positive correlation between a decrease in maximum airflow rate and a decrease in maximum sound pressure level, on a negative correlation between a decrease in maximum airflow rate and a increase in duration.