• Title/Summary/Keyword: Volume Calibration

Search Result 252, Processing Time 0.023 seconds

A Study on the Visualization and Characteristics of Mixed Convection between Inclined Parallel Plates Filled with High Viscous Fluid (경사진 평행평판 내 고 점성유체의 혼합대류 열전달 특성 및 가시화에 관한 연구)

  • Piao, Ri-Long;Bae, Dae-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.698-706
    • /
    • 2006
  • Experiment and numerical calculation have been peformed to investigate mixed convection heat transfer between inclined parallel plates. Particle image velocimetry (PIV) with thermo-sensitive liquid crystal (TLC) tracers is used for visualizing and analysis. This method allows simultaneous measurement of velocity and temperature fields at a given instant of time. Quantitative data of the temperature and velocity are obtained by applying the color-image processing to a visualized image, and neural network is applied to the color-to-temperature calibration. The governing equations are discretized using the finite volume method. The results are presented for the Reynolds number ranges from 0.004 to 0.062, the angle of inclination, ${\Theta}$, from 0 to 45 degree and Prandtl number of the high viscosity fluid is 909. The results show velocity, temperature and mean Nusselt numbers distributions. It is found that the periodic flow of mixed convection between inclined parallel plates is shown at $0^{\circ}{\leq}{\Theta}<30^{\circ}$, Re<0.062, and the flow pattern can be classified into three patterns which depend on Reynolds number and the angle of inclination. The minimum Nusselt numbers occur at Re=0.05 regardless of the angle of inclination.

A Comparison of Spinosin Content in Zizyphi Semen and Its Processed Products by Roasting (산조인의 수치에 따른 Spinosin 함량 비교)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Kim, Byoung-Soo
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.4
    • /
    • pp.360-365
    • /
    • 2016
  • The aim of this study was to compare the amount of spinosin in the 70% ethanol extracts of non-processed Zizyphi Semem (ZS) and processed ZS by roasting using a high-performance liquid chromatography equipped with photodiode array detector. Separation of the spinosin was used $SunFire^{TM}$ $C_{18}$ analytical column ($5{\mu}m$, $4.6{\times}150mm$) using two mobile phase consisting of distilled water and acetonitrile, both with 1.0% (v/v) acetic acid. The flow rate was 1.0 mL/min and injection volume was $10{\mu}L$. Calibration curve of the spinosin was y = 22339.45x+483.99 in tested concentration range ($1.28-20.00{\mu}g/mL$) and correlation coefficient was 1.0000. In non-processed ZS sample, the amount of the spinosin was 0.94 m/g, while, the amount of the marker compound in processed ZS samples were 0.66-1.10 mg/g.

Analytical Method of Epichlorohydrin in Canned Beverages by Purge-and- Trap/GC

  • Lee Kwang-Ho;Kwak In-Shin;Kim Dyoung-Il;Choi Byoung-Hee;Kim Guy-Joung;Lee Chul-Won
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2001.10a
    • /
    • pp.140-140
    • /
    • 2001
  • A sensitive analytical method based on gas chromatograpy-mass spectrometry with a selected ion monitoring (GC/MS-SIM) with the purge-and-trap concentration and with headspace method (in limited applications) was developed for determining of epichlorohydrin in canned beverages coated with epoxy resin. The calibration curve in the range of $0.5\sim50ng$ had correlation coefficient greater than 0.998 and a detection limit of $0.l\mug/L$ was obtained using a sample volume of 20ml. The predominant ions of epichlorohydrin produced in MSD using electron ionization(EI) were m/z 57 ([M-CI]+) and 62/64 $([M-CH_2O]+)$. In survey of epichlorohydrin in thirty commercial canned beverage samples, none of them was detected.

  • PDF

Development of Stream Width and Bed-slope Estimation Equations for Preparing Data for Distributed Storm Runoff Model (분포형 강우-유출모형의 하도자료 구축을 위한 하폭 및 하상경사 산정공식 개발)

  • Jung, In-Kyun;Park, Jong-Yoon;Joh, Hyung-Kyung;Lee, Ji-Wan;Kim, Seong-Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.4
    • /
    • pp.1-10
    • /
    • 2010
  • In this study, two estimation equations for preparing stream data for distributed storm runoff model were developed by analyzing the nonlinear relation between upstream flow-length and stream width, and between upstream flow-length and stream bed-slope. The equations for stream cell were tested in Chungjudam watershed (6,661 $km^2$) using KIMSTORM. Six storm events occurring between 2003 and 2008 were selected for the model calibration and verification before the test of equations. The average values of the Nash-Sutcliffe model efficiency (ME), the volume conservation index (VCI), the relative error of peak runoff rate (EQp), and the difference of time to peak runoff (DTp) were 0.929, 1.035, 0.037, and -0.406 hr for the calibrated four storm events and 0.956, 0.939, 0.055, and 0.729 hr for the two verified storm events respectively. The estimation equations were tested to the storm events, and compared the flood hydrograph. The test result showed that the estimation equation of stream width reduced the peak runoff and delaying the time to peak runoff, and the estimation equation of stream bed-slope showed the opposite results.

Development of the Insufflator for Endoscopic Surgery using the Fluidic System in Printed Circuit Board (유공압 부품이 내장된 인쇄회로기판을 활용한 내시경 수술용 기복기의 개발)

  • Lee, Hee-Nam;Kim, In-Young;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.32-36
    • /
    • 2011
  • The insufflators in endoscopic surgery supply carbon dioxide to make the air-filled cavity in the abdomen. It contains many kinds of pneumatic and electronic parts and they are connected with the air tubes and electrical wires. The printed circuit boards (PCB) perform wiring, holding and cooling tasks in electronic systems. In this study, the PCB is used as the air channel for insufflators to decrease the cost, volume, and the malfunction according to aging of the device. Three layers of PCB made of FR4 are combined with prepreg as adhesive which has the internal airway channel according to the design. By mounting the pressure sensors and valves, the PCB based fluidic system is implemented. After calibration of flow sensor, the flow rate of the gas also can be measured. The climate test, temperature test, and biocompatibility test showed this idea can be used in insufflators for laparoscopic surgery.

Kalman Filter Estimation of the Servo Valve Effective Orifice Area for a Auxiliary Power Unit (보조 동력장치용 서보밸브 유효 오리피스 면적의 칼만필터 추정)

  • Zhang, J.F.;Kim, C.T.;Jeong, H.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Flow rate is one of the important variables for precise motion control and detection of the faults and fluid loss in many hydraulic components and systems. But in many cases, it is not easy to measure it directly. The orifice area of a servo valve by which the fluid flows is one of key factors to monitor the flow rate. In this paper, we have constructed an estimation algorithm for the effective orifice area by using the model of a servo valve cylinder control system and Kalman filter algorithm. Without geometry information about the servo valve, it is shown that the effective orifice area can be estimated by using only displacement and pressure data corrupted with noise. And the effect of the biased sensor data and system parameter errors on the estimation results are discussed. The paper reveals that sensor calibration is important in accurate estimation and plausible parameter data such as oil bulk modulus and actuator volume are acceptable for the estimation without any error. The estimation algorithm can be used as an useful tool for detecting leakage, monitoring malfunction and/or degradation of the system performance.

  • PDF

Exploration of Isovist Fields to Model 3D Visibility With Building Facade

  • Chang, Dong-Kuk;Park, Joo-Hee
    • Architectural research
    • /
    • v.13 no.3
    • /
    • pp.19-29
    • /
    • 2011
  • Visibility of a space have been defined in several different ways: such as the axial line covering a convex space, a convex space defining the fattest shape in a space and an Isovist field formed by a field of vision at a given vantage point. Isovist fields are referred to as a descriptive medium to describe a movement by reviewing and analyzing geometric properties in them. Many descriptive methods for analysis of three-dimensional isovist are applied to analyzing the morphological properties in a 3D space more realistically. Although these models are regarded as a more advanced method for describing spatial properties, they have pros and cons such as complex mathematical calculations and somewhat arbitrary calibration in addition to huge consumption of memory space. These difficulties lead to the development of a three-dimensional visual accessibility model that explores the implication of building shape on the calculation of isovist fields drawn on a 2D plane. We propose a conceptual framework of how to measure the isovist field not as a 3D volume but as a combination of 2D plane on the ground with the 3D building shape of it's facade.

Data processing of sensor output for correction of pressure measurement value of an anesthesia ventilator (마취기용 인공호흡기의 압력 측정값의 보정을 위한 센서 출력의 데이터 처리)

  • 박영준;이종수;김영길
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1067-1070
    • /
    • 1999
  • Anesthesia gas to pour to patients affects the flow and volume as the pressure difference of an oxygen and an anesthesia gas. An anesthesia gas, being injurious and polluting an environment, must control the pressure of an oxygen gas because of being used by closing up tight. But a pressure sensor to use for measuring an oxygen gas appears other pressure as the characteristic and the error difference of elements to use for implementing an system. A medical machine such as an anesthesia ventilator must be accurate because of using for the person's body. So we intend to implement an system for a sensor pressure measurement not to be change regardless of an environment. This papers is the target that a sensor pressrue measurement to be changed in environment is equal to actual sensor pressure measurement. So an implemented system is using analog filter and digital filter to reduce a noise. And we are using auto-zeroing and calibration to correct a sensor pressure which is changed in environment. Through such a process we increase the accuracy and the confidence of an anesthesia ventilator by controlling the flow of an anesthesia gas.

  • PDF

Sorption Preconcentration and Determination of Nickel in Wastes of Heat Power Industry by Diffuse Reflection Spectroscopy

  • Kalyakina, O.P.;Kononova, O.N.;Kachin, S.V.;Kholmogorov, A.G.
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.2
    • /
    • pp.173-177
    • /
    • 2003
  • The present work is focused on the preconcentration of nickel and its determination by means of diffuse reflection spectroscopy. The preconcentration of nickel was carried out by sorption on macroporous aminocarboxylic amphoteric resin ANKB-35. Based on this collector, a method to determine nickel in wastes of heat power industry was worked out using solid-phase spectroscopy. The colored surface compound to be determined was obtained by a preceding nickel sorption on the resin and by subsequent treatment of the concentrate obtained with definite amounts of 1-(2-pyridilazo)-2-naphtol (PAN). The Ni calibration curve is linear in the concentration range of 0.5-20.0 mg/L (sample volume is 200.0 mL) and the detection limit is 0.05 mg/L. The presence of $Cu^{2+},\;Fe^{3+},\;Co^{2+}$ ions as well as macrocomponents of natural water $(Na^+,\;K^+,\;Ca^{2+},\;Mg^{2+})$ do not hinder the solid-phase spectroscopy determination of nickel. The nickel determination by diffuse reflection spectroscopy was carried out in model solutions as well as in solutions obtained after the dissolution of wastes of heat power industry.

Identification on the Three-Dimensional Vortical Structures of Impeller Flow by a Multi-Plane Stereoscopic PIV Method (스테레오 PIV 기법에 의한 임펠러 와류유동의 3차원 구조측정)

  • Yoon, Sang-Youl;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.773-780
    • /
    • 2003
  • The three-dimensional spatial structures of impeller flow created by a six bladed Rushton turbine have identified based on the volumetric velocity information from multi-plane stereoscopic PIV measurements. A total of 10 planes with 2 mm space and a 50 mm by 64 mm size of the field of view were targeted. To reduce the depth of focus, we adopted an angle offset configuration which satisfied the Scheimpflug condition. The distortion compensation procedure was utilized during the in situ calibration. Phase-locked instantaneous data were ensemble averaged and interpolated in order to obtain mean 3-D. volumetric velocity fields on a 60 degree sector of a cylindrical ring volume enclosing the turbine blade. Using the equi-vorticity surface rendering, the spatial structure of the trailing vortices was clearly demonstrated. Detail flow characteristics of the radial jet reported in previous studies of mixer flows were easily identified.