• Title/Summary/Keyword: Volume & Mass

Search Result 1,443, Processing Time 0.023 seconds

Aerosol Density Determined Using Micro-orifice Uniform Deposit Impactor and Aerosol Dust Monitors Data at Seoul (다단입자채집기와 입자계수기 자료를 이용한 서울 에어러솔 밀도 계산)

  • Kim, Jeong-Eun;Lee, Hae-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.298-304
    • /
    • 2010
  • In order to calculate the aerosol bulk densities of $PM_{1.0}$ and $PM_{10}$, aerosol mass and number concentrations were measured for the period of December 2008~April 2009. $PM_{1.0}$ and $PM_{10}$ mass concentrations were measured using a cascade impactor (Micro-Orifice Uniform Deposit Impactor, MOUDI) while their volume concentrations were calculated based on number concentrations from an environmental dust monitor (EDM). Normal aerosol size distribution fitting functions were retrieved for number size distribution since aerosols < $2.5{\mu}m$ were measured from the EDM. Strong correlation was found between $PM_{1.0}$ mass and volume concentrations obtained with a $R^2$ of 0.95. The calculated average bulk densities of $PM_{1.0}$ and $PM_{10}$ were $1.97{\pm}0.33g/cm^3$ and $2.15{\pm}0.18g/cm^3$, respectively.

Analytic Study for Alcohol Consumption-related Parameters in 53 Heavy Drinkers (과음하는 성인남자 53 명의 음주패턴과 간 장애에 대한 분석 연구)

  • Hong, Sang-Hun;Cho, Jung-Hyo;Son, Chang-Gue
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.1
    • /
    • pp.115-123
    • /
    • 2007
  • Objectives : To investigate the correlations among alcohol consumption, alcoholic liver disorders, physical symptoms, and behaviors in heavy drinkers. Methods : 53 males who self-realized their severe alcohol consumption were enrolled in this study. 10 answers for a questionnaire, serum parameter, sonographic finding and body mass index were attained. The correlations between them were analyzed using Pearson's correlation and Student's t-test. Results : The average consumption of alcohol in these subjects was 2.5-fold over social drinkers. The incidence of alcoholic hepatitis was around 30%, while fatty liver 73%, and abnormal GGT 77%, respectively. No specific correlation between average volume of daily alcoholic consumption and alcohol-related hepatic parameters was shown in this study, but correlative tendency between fatty liver and body mass index was exhibited. Conclusions : This study may indicate that alcoholic liver injuries are caused by not just volume of alcohol consumed but more mixed factors including inherited genetic components, body fat mass, foods and other physical or emotional stress.

  • PDF

Numerical Study of Spray Characteristics of n-Heptane in Constant Volume Combustion Chamber under Diesel Engine Conditions (정적연소기를 이용한 디젤 엔진 조건에서 n-Heptane의 분무특성에 관한 수치해석 연구)

  • DAS, SHUBHRA KANTI;LIM, OCKTAECK
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.6
    • /
    • pp.727-736
    • /
    • 2016
  • Numerical simulations of n-heptane spray characteristics in a constant volume combustion chamber under diesel engine like conditions with increasing ambient gas density ($14.8-142kg/m^3$) and ambient temperature (800-1000 K) respectively were performed to understand the non-vaporizing and vaporizing spray behavior. The effect of fuel temperature (ranging 273-313 K) on spray characteristics was also simulated. In this simulation, spray modeling was implemented into ANSYS FORTE where the initial spray conditions at the nozzle exit and droplet breakups were determined through nozzle flow model and Kelvin-Helmholtz/Rayleigh-Taylor (KH-RT) model. Simulation results were compared with experimentally obtained spray tip penetration result to examine the accuracy. In case of non-vaporizing condition, simulation results show that with an increment of the magnitude of ambient gas density and pressure, the vapor penetration length, liquid penetration length and droplet mass decreases. On the other hand vapor penetration, liquid penetration and droplet mass increases with the increase of ambient temperature at the vaporizing condition. In case of lower injection pressure, vapor tip penetration and droplet mass are increased with a reduction in fuel temperature under the low ambient temperature and pressure.

Effect of Mg content on the density and critical properties of in-situ reacted MgB2 bulk superconductor

  • Jun, Byung-Hyuk;Kim, Dan-Bi;Park, Soon-Dong;Kim, Chan-Joong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.19-22
    • /
    • 2014
  • The effects of Mg content on the pore formation, density and critical properties were investigated in in-situ reacted $MgB_2$ superconductors. The $Mg_{1+x}B_2$, (x=-0.2, 0.0, 0.05, 0.3, 1.0) bulk samples with different Mg contents were heat-treated at $900^{\circ}C$ for 1 h in an Ar atmosphere. The dimensional changes of a pellet's mass and volume after heat-treatment were measured. After heat-treatment process, the sample mass was decreased by Mg evaporation, but the sample volume was expanded by pore formation at the Mg site; therefore, the apparent density was decreased. Spherical pores the same as Mg particles were developed after heat-treatment in all samples, and the pore density was increased with increasing Mg content. As the x of Mg content was increased to 1.0, the apparent density of $Mg_{1+x}B_2$ samples was decreased due to a relatively larger reduction in a mass change. The critical current density of Mg excessive sample of x=0.05 showed the highest values over the applied magnetic fields because the excessive Mg may compensate Mg loss and enhance grain connectivity.

Analytical Study on Unsteady Flow Characteristics of Urea-SCR Single Hole Injector depend on Nozzle Shape Change (Urea-SCR 단홀 Injector 노즐형상 변화에 따른 비정상유동특성의 해석적 연구)

  • Hwang, Jun Hwan;Park, Sung-Young
    • Journal of ILASS-Korea
    • /
    • v.24 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • In this paper, a study of Urea-SCR System for Dosing Injector for responding to enhanced environmental regulations has been conducted. There is a limit to the experimental approach due to the structural characteristics of the injector. In order to overcome this problem, The analysis was performed assuming unsteady turbulent flow through computational fluid analysis and the internal flow characteristics of the injector were analyzed. By changing the nozzle shape of the injector, the performance factors of the swirl injector by shape were selected and compared. The design parameters were modified by changing the diameter of the nozzle at a constant ratio compared to the base model. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. The Conv. model to which the taper was applied showed the dominance in mass flow rate, discharge coefficient and swirl because of the smooth fluid flow by shape. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. As a result of the comparison coefficient derivation with those performance parameters for comparing the performance of the model-specific injector, the Conv-140 model with the nozzle diameter expanded by 140% showed the best value of the comparison coefficient.

Air horizontal jets into quiescent water

  • Weichao Li ;Zhaoming Meng;Jianchuang Sun;Weihua Cai ;Yandong Hou
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2011-2017
    • /
    • 2023
  • Gas submerged jet is an outstanding thermohydraulic phenomenon in pool scrubbing of fission products during a severe nuclear accident. Experiments were performed on the hydraulic characteristics in the ranges of air mass flux 0.1-1400 kg/m2s and nozzle diameter 10-80 mm. The results showed that the dependence of inlet pressure on the mass flux follows a power law in subsonic jets and a linear law in sonic jets. The effect of nozzle submerged depth was negligible. The isolated bubbling regime, continuous bubbling regime, transition regime, and jetting regime were observed in turn, as the mass flux increased. In the bubbling regime and jetting regime, the air volume fraction distribution was approximately symmetric in space. Themelis model could capture the jet trajectory well. In the transition regime, the air volume fraction distribution loses symmetry due to the bifurcated secondary plume. The Li correlation and Themelis model showed sufficient accuracy for the prediction of jet penetration length.

Settlement and Mass Change of the Porous Concrete Using Super Absorbent Polymer (고흡수성 수지를 활용한 다공 구조 콘크리트 가능성 연구)

  • Jo, Jae-Hyun;Park, Jae-Woong;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.311-312
    • /
    • 2023
  • In this study, porous concrete with improved functionality was developed by using superabsorbent polymer (SAP) to provide rooting space for plants. The depth of settlement and mass change according to the substitution and addition rate of SAP were determined by investigating the functional performance of SAP and the volume change upon saturation. Test results indicated the depth of penetration settlement increased as the substitution rate of SAP increased, but the mass change could not be confirmed as the addition rate of SAP increased. The instability of the specimens due to the excessive volume change of SAP, as well as the osmotic pressure phenomenon according to the pH concentration, were identified as the cause. Therefore, future studies are needed to investigate the appropriate substitution and addition rate of SAP, as well as to reduce the osmotic pressure phenomenon according to the pH concentration, which would contribute to the improvement of the functional performance of vegetation concrete.

  • PDF

Analysis of Factors Influencing Changes in Left Atrium and Left Ventricle Size in Adults (성인의 좌심방과 좌심실 크기변화에 미치는 영향 요인 분석)

  • Sun-Hwa Kim;Sung-Hee Yang
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2024
  • This study analysed the factors that predict and influence heart disease through key indicators related to changes in left atrial and left ventricular size. Measurements recommended by the American Society of Echocardiography were used, and the influence of variables was assessed using multiple regression analysis. The results showed that left atrial volume index(LAVI) was significantly different by age, obesity, diabetes, hypertension, dyslipidaemia, and left ventricular relaxation dysfunction(p<0.05). Left ventricular mass index(LVMI) was significantly different according to age, body mass index, hypertension, diabetes, dyslipidaemia, and left ventricular relaxation dysfunction(p<0.05). Increases in LVMI and relative ventricular wall thickness(RWT) were associated with changes in LAVI(p<0.05). Age, systolic blood pressure, increased LAVI, and RWT influenced changes in LVMI, and left ventricular dysfunction was analysed as an influencing factor for both changes in LAVI and LVMI. Therefore, changes in left atrial and left ventricular size are indicators for early diagnosis and prevention of heart disease, and it is necessary to carefully observe structural changes in the heart and actively manage risk factors for the prevention and management of heart disease.

Nuclear waste attributes of near-term deployable small modular reactors

  • Taek K. Kim;L. Boing;B. Dixon
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.1100-1107
    • /
    • 2024
  • The nuclear waste attributes of near-term deployable SMRs were assessed using established nuclear waste metrics, which are the DU mass, SNF mass, volume, activity, decay heat, radiotoxicity, and decommissioning LLW volumes. Metrics normalized per unit electricity generation were compared to a reference large PWR. Three SMRs, VOYGR, Natrium, and Xe-100, were selected because they represent a range of reactor and fuel technologies and are active designs deployable by the decade's end. The SMR nuclear waste attributes show both some similarities to the PWR and some significant differences caused by reactor-specific design features. The DU mass is equivalent to or slightly higher than the PWR. Back-end waste attributes for SNF disposition vary, but the differences have a limited impact on long-term repository isolation. SMR designs can vary significantly in SNF volume (and thus heat generation density). However, these differences are amenable to design optimization for handling, storage, transportation, and disposal technologies. Nuclear waste attributes from decommissioning vary depending on design and decommissioning technology choices. Given the analysis results in this study and assuming appropriate waste management system and operational optimization, there appear to be no major challenges to managing SMR nuclear wastes compared to the reference PWR.

Mass Transfer of Gas-Liquid in Agitated Vessel Using Wire Gauge Impeller (금망임펠러를 이용한 교반조에서의 기-액 물질이동)

  • Lee, Young-Sei
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.1
    • /
    • pp.19-26
    • /
    • 2008
  • The gas-liquid mass transfer volumetric coefficients in gas-liquid agitated vessels with wire gauge impellers were measured to be compared with those in vessels with disk turbine and paddle impellers. Also mass transfer volumetric coefficients for disk turbine, paddle impeller and wire gauge impeller in cylindrical agitated vessel was measured over a wide range of Reynolds number from turbulent flow to transition regions. The effect of geometries on $k_La$ is clarified experimentally. Mass transfer volumetric coefficients $k_La$ depends only on the power consumption ($P_{gv}+P_{av}$) per unit volume.

  • PDF