• 제목/요약/키워드: Voltage-balance

검색결과 301건 처리시간 0.023초

NPC와 B-Bridge 컨버터의 부스트 벡터와 커패시터전압의 해석 (Analysis of Capacitor Voltage and Boost Vector in Neutral-Point-Clamped and H-Bridge Converter)

  • 김정균;김태진;강대욱;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.489-493
    • /
    • 2002
  • This paper discover another boost vectors in high modulation index In steady states, modulation index of converter operation is normally $0.7\~0.8[p.u]$. Even though zero vectors are not imposed, DC-Link voltage is constant because 3-level boost convert has another boost vectors. and this paper proposes the analysis and the comparison for NPC and H-Bridge converter. It proposed the calculation method for the voltage ripple and charging current of each capacitor and deals with voltage balance problems of each link capacitor they are associated with the switching state, the position of reference voltage vector. Simulation and analysis are used in order to prove validity of the proposed methods.

  • PDF

IGBT 직렬 연결을 위한 게이트 구동기법 (An Improved Gate Control Scheme of Series Connected IGBTs)

  • 김완중;최창호;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.195-197
    • /
    • 1998
  • The large scale industry needs high voltage converters. Therefore series connection of power semiconductor devices is necessary. It is important to prevent a device induced the overvoltage above ratings by proper voltage balancing in the field of IGBT series connection. In addition, the overvoltage induced by a stray inductance has to be limited in the high power circuit. This paper proposes a new gate control scheme which can balance the voltage properly and limit the overshoot by control the slope of collector voltage under series connected IGBT turn-off transient. The propose gate control scheme limits the overvoltage by sensing the collector voltage and controlling the gate signal actively. The new series connected IGBT gate driver is made and its validity is verified by the experimental results for series connected IGBT circuit.

  • PDF

Neutral-point Voltage Balancing Strategy for Three-level Converter based on Disassembly of Zero Level

  • Wang, Chenchen;Li, Zhitong;Xin, Hongliang
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.79-88
    • /
    • 2019
  • The neutral-point (NP) voltage of three-phase three-level NP-clamped converters is needed for balance. To maintain NP potential and suppress ripple, a novel NP voltage balancing strategy is proposed in this work. The mechanism of NP voltage variation is studied first. Then, the relationship between the disassembly of zero level (O level) and NP current is studied comprehensively. On these bases, two methods for selecting one of three output phases for the disassembly of its O level are presented. Finally, simulation and experimental results verify the validity and practicability of the proposed algorithms.

보조 회로를 활용한 ZCZVT 소프트 스위칭 부스트-플라이백 컨버터 (A Zero-Current-Zero-Voltage-Transition Boost-Flyback Converter Using Auxiliary Circuit)

  • 주현승;최현칠
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.372-378
    • /
    • 2019
  • This study proposes a new zero-current-zero-voltage-transition (ZCZVT) boost-flyback converter using a soft switching auxiliary circuit. The proposed converter integrates the boost and flyback converters to increase the voltage with a low duty ratio. The main and auxiliary switches turn the ZCZVT conditions on and off. Thus, the proposed converter has high efficiency. The voltage gain at the steady state is derived, and the inductor volt-second balance and the design guidelines are presented. Finally, the performance of the proposed converter is validated by experimental results from a 200 W, 30 V DC input, 400 V DC output, and 200 kHz boost-flyback converter prototype.

저궤도 위성의 에너지 균형 분석을 위한 전력 시뮬레이터의 구현 (Implementation of a Power Simulator for Energy Balance Analysis of a LEO Satellite)

  • 전문진;이나영;김대영;김규선
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.176-184
    • /
    • 2010
  • 지구 저궤도 위성의 임무 운용 시 전력 시스템을 안전하고 운용하고 에너지 균형을 만족하는 임무를 설계하기 위해 계획된 임무에 대한 전력 파라미터를 예측해야 한다. 이 논문에서는 다양한 미션 프로파일에 대해 위성의 생성 전력, 소모 전력, 배터리 방전 정도(Depth of Discharge, 이하 DoD), 버스 전압, 충/방전 전류 등을 예측함으로써 미션의 유효성 및 에너지 균형을 검증하기 위한 전력 시뮬레이터를 제안한다. 제안된 전력 시뮬레이터에는 인공위성의 생성 전력을 모사하기 위해 태양전지판(Solar Array, 이하 SA)의 모델, SAR (Solar Array Regulator)의 3가지 동작 모드를 구현하였다. 또한 소모 전력을 모사하기 위해 버스 및 탑재체의 각 유닛 별 소모 전력, Unit on/off configuration, 탑재체 운용 모드 등을 고려하였다. 버스 전압 및 충/방전 전류를 예측하기 위해 배터리 및 주변 회로를 모델링하고 임의의 DoD, 충방전 전류에 대해 배터리 전압 및 버스 전압을 예측한다. 구현된 전력 시뮬레이터를 이용해 에너지 균형을 분석하고 임무 계획의 적합성을 쉽게 판단할 수 있다.

A Simple Control Strategy for Balancing the DC-link Voltage of Neutral-Point-Clamped Inverter at Low Modulation Index

  • C.S. Ma;Kim, T.J.;D.W. Kang;D.S. Hyun
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.205-214
    • /
    • 2003
  • This paper proposes a simple control strategy based on the discontinuous PWM (DPWM) to balance the DC-link voltage of three-level neutral-point-clamped (NPC) inverter at low modulation index. It introduces new DPWM methods in multi-level inverter and one of them is used for balancing the DC-link voltage. The current flowing in the neutral point of the DC-link causes the fluctuation of the DC-link voltage of the NPC inverter. The proposed DPWM method changes the path and duration time of the neutral point current, which makes the overall fluctuation of the DC-link voltage zero during a sampling time of the reference voltage vector. Therefore, by using the proposed strategy, the voltage of the DC-link can be balanced fairly well and the voltage ripple of the DC-link is also reduced significantly. Moreover, comparing with conventional methods which have to perform the complicated calculation, the proposed strategy is very simple. The validity of the proposed DPWM method is verified by the experiment.

Fault Tolerant Control of DC-Link Voltage Sensor for Three-Phase AC/DC/AC PWM Converters

  • Kim, Soo-Cheol;Nguyen, Thanh Hai;Lee, Dong-Choon;Lee, Kyo-Beum;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.695-703
    • /
    • 2014
  • In this paper, a fault detection scheme for DC-link voltage sensor and its fault tolerant control strategy for three-phase AC/DC/AC PWM converters are proposed, where the Luenberger observer is applied to estimate the DC-link voltage. The Luenberger observer is based on a converter model, which is derived from the voltage equations of a grid-side converter and the power balance on a DC link. A fault of the voltage sensor is detected by comparing the measured value of the DC-link voltage with the estimated one. When a sensor fault is detected, a fault tolerant control strategy is performed, where the estimated DC-link voltage is used for the feedback control. The estimation error from the observer is about 1.5 V, which is sufficiently accurate for feedback control. In addition, it is shown that the observer performance is robust to parameter variations of the converter. The validity of the proposed method has been verified by simulation and experimental results.

양극성 DC 배전 시스템 적용을 위한 결합 인덕터 기반의 전압 밸런싱 이중 출력 CLL 공진형 컨버터 (Coupled Inductor Based Voltage Balancing in Dual-Output CLL Resonant Converter for Bipolar DC Distribution System)

  • 이승훈;김정훈;차헌녕
    • 전력전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.348-355
    • /
    • 2022
  • A bipolar DC distribution system suffers from an imbalance in voltages when asymmetric loads are connected at the outputs. Dedicated voltage balancers are required to address the imbalance in bipolar voltage levels. However, additional components eventually increase the cost and decrease the efficiency and power density of the system. Therefore, to deal with the imbalance in output voltages without adding any extra components, this study presents a coupled inductor-based voltage balancing technique with a dual-output CLL resonant converter. The proposed coupled inductor does not require extra magnetic components to balance the output voltages because it is the result of resonant inductors of the CLL tank circuit. It can also avoid complex control schemes applied to voltage balancing. Moreover, with the proposed coupled inductor, the CLL converter acquires good features including zero voltage and zero current switching. Detailed analysis of the proposed coupled inductor is presented with different load conditions. A 3.6-kW hardware prototype was built and tested to validate the performance of the proposed coupled inductor-based voltage balancing technique.

다채널 경혈평형 계측 시스템 구현에 관한 연구 (A Development of Multi-Channel Acupuncture Point Balance Measurement System)

  • 김창모;김응수;한순천;김정국;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2903-2906
    • /
    • 2003
  • In this paper, we developed a multichannel acupuncture point balance measurement system that measures skin resistances at various acupuncture points to evaluate the balancing state of the meridian. The system consists of 16 channel resistance-voltage converter, signal processing part for signal amplification and filtering, A/D conversion part, micro-controller part, and data processing part. Compared to the previously developed 1 channel or 4 channel systems, it is found that the 16 channel system can measure the skin resistances of 16 acupuncture points, simultaneously, providing various clinical information such as balance and variation of the resistance value.

  • PDF

GMA용접의 아크빛 모델 및 용접선 추적에의 응용 (Modeling of Are Light Intensity and Its Application to Weld Seam Tracking in GMAW)

  • 유용상;최상균;유중돈;선우희권
    • Journal of Welding and Joining
    • /
    • 제14권5호
    • /
    • pp.113-121
    • /
    • 1996
  • The arc sensor has been most widely used for weld seam tracking through welding current or voltage variation. In this work, the relation between the arc light intensity and welding condition is investigated using heat balance in the Plasma for its possible application to seam tracking in the GMAW process. The arc light intensity is derived to be the function of the arc length and welding current Experiments are carried out to verify the proposed heat balance model. Performances of least square and integration methods to process the signals for seam tracking are compared experimentally. Predicted arc light intensity shows reasonably good agreement with experimental results. The weld seam is successfully tracked through the arc light intensity. The least square and integration methods demonstrate almost same performance of seam tracking with $CO_2$gas shielding.

  • PDF