• Title/Summary/Keyword: Voltage variation compensation

Search Result 126, Processing Time 0.024 seconds

Analysis and Compensation of PCC Voltage Variations caused by Wind Turbine Power Fluctuations

  • Im, Ji-Hoon;Song, Seung-Ho;Kang, San
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.854-860
    • /
    • 2013
  • The voltage variation problem at the point of common coupling (PCC) in a grid-connected wind turbine is investigated. The voltage variation problem is one of the most frequent power quality issues for the grid connection of large amounts of input power in a weak grid. Through the simplified modeling of the wind turbine and power network, the magnitude of PCC voltage variation is calculated by using the equivalent circuit parameters and output power of the wind turbine. The required amount of reactive power that can compensate the voltage variation is also presented analytically by using the vector diagram method. The proposed calculation and compensation method of the PCC voltage variation is verified by computer simulations and experiments.

Single-Phase Series Type Quasi Z-Source Voltage Sag-Swell Compensator for Voltage Compensation of Entire Region (전 영역의 전압보상을 위한 단상 직렬형 Quasi Z-소스 전압 Sag-Swell 보상기)

  • Eom, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.322-332
    • /
    • 2013
  • Conventional single-phase series quasi Z-source voltage compensator can not compensate for voltage sag less than 50% that frequently occurs in the industrial field. In this study, single-phase series quasi Z-source voltage sag-swell compensator which can compensate the voltage variation of entire range is proposed. The proposed system is composed of two quasi Z-source AC-AC converters connected in series with output terminal stage. Voltage sag less than 50% could be compensated by the intersection switching control of the upper converter duty ratio and of the upper converter duty ratio. Also the compensation voltage and its flowchart for each compensation mode are presented for entire sag-swell region. To confirm the validity of the proposed system, a DSP(DSP28335) controlled experimental system was manufactured. As a result, the proposed system could compensate for the voltage sag/swell of 20% and 60%. Finally, voltage compensation factor and THD(Total Harmonic Distortion) according to voltage variation and load change were measured, and voltage quality shows a good results.

DC-link Voltage Ripple Compensation Method for Single Phase 3-level PWM Converters (단상 3-레벨 PWM 컨버터를 위한 중성점 전압 변동 보상 기법)

  • Lee, Hee-Myun;Lee, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.8-15
    • /
    • 2013
  • This paper proposes a DC-link voltage variation compensation method for a 3-level single phase converter for high-speed trains. Since 3-level NPC(Neutral Point Clamped) type converters have the split DC-link causing the inherent problem of voltage fluctuations in the upper and lower capacitors, reducing the voltage difference between the top and bottom capacitors is required. In this paper, compensation time proportional to the voltage difference is added to PWM switching time to solve the voltage variation. The compensation time is obtained by a PI controller. Simulation results demonstrate the validity of the proposed method.

Motor Control Method for Four-Switch Inverters with DC-link Voltage Ripple Compensation Algorithm (Four-Switch 인버터의 전압 변동 보상 기법을 통한 전동기 운전 기법)

  • Lee, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.59-66
    • /
    • 2013
  • This paper proposes a new voltage reference generation method for Four-Switch Inverters(FSI) with compensation of the neutral DC-link voltage variation. Since FSIs have the split DC-link causing the inherent problem of voltage fluctuations in the upper and lower capacitors, it is required to take account the voltage difference between the top and bottom capacitors. In this paper, to reduce the effect by the voltage variation, reference voltages are modified by adding compensation voltages proportional to the voltage difference between upper and lower capacitors. Simulation results showing control performance of induction and permanent magnet motors demonstrate the validity of the proposed method.

A study on optimal voltage compensation method in west Gyeongnam Power systems (서부경남지역 전력계통의 최적전압 보상에 관한연구)

  • Joung, Yun-Ki;Kim, Seng-Hwan;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.164-167
    • /
    • 2001
  • In resent years, electric power quality has become an important issue in power system. Voltage variation and compensation countermeasures of KEPCO system in west Gyeongnam have been simulated using PSS/E. In this paper, in the abnormal power system, the adaption of SVC, high speed and continuous control are simulated for voltage compensation. It is shown that the SVC is the optimal voltage compensation method in loop power system or 2 lines radial system.

  • PDF

Energy Management Method of DC Microgrids by Using Voltage Compensation Term (전압 변동 보상항을 이용한 직류 마이크로그리드의 에너지 관리 기법)

  • Ko, Byoung-Sun;Lee, Gi-Young;Kim, Seok-Woong;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.328-335
    • /
    • 2018
  • An energy management method of DC microgrids using voltage compensation term is proposed in this study. Droop control is often implemented to operate the DC microgrid. However, the droop control necessarily generates voltage variation. Energy flow is also difficult to control because the droop control mainly focuses on proportional load sharing. To solve these problems, the voltage compensation term based on the low-bandwidth communication is used to determine the operating band of the converter. Energy management and voltage variation minimization can be achieved by judging the operating band according to the magnitude of voltage compensation term. The validity of the proposed method is verified by simulation and experiments.

The Maximum Installable DG Capacity According to Operation Methods of Voltage Regulator in Distribution Systems (배전계통의 전압조정기 운영방법에 따른 분산형전원 최대 도입 용량 산출)

  • Kim, Mi-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1263-1269
    • /
    • 2009
  • Stable and sustainable power supply means maintaining a certain level of power quality and service while securing energy resource and resolving environmental issues. Distributed generation (DG) has become an essential and indispensable element from environmental and energy security perspectives. It is known that voltage violation is the most important constraint for load variation and the maximum allowable DG. In distribution system, sending voltage from distribution substation is regulated by ULTC (Under Load Tap Changer) designed to maintain a predetermined voltage level. ULTC is controlled by LDC (Line Drop Compensation) method compensating line voltage drop for a varying load, and the sending voltage of ULTC calls for LDC parameters. The consequence is that the feasible LDC parameters considering variation of load and DG output are necessary. In this paper, we design each LDC parameters determining the sending voltage that can satisfy voltage level, decrease ULTC tap movement numbers, or increase DG introduction. Moreover, the maximum installable DG capacity based on each LDC parameters is estimated.

Compensation of Voltage Variation Using Active Power-Dependent Reactive Power Control with Multiple VRE Systems Connected in a Distribution Line (배전 선로에 연계된 다수대의 변동성 재생에너지 발전 시스템의 출력 유효전력 변동에 따른 무효전력 제어를 이용한 전압 변동 보상)

  • Lee, Sang-Hoon;Kim, Soo-Bin;Song, Seung-Ho
    • Journal of Wind Energy
    • /
    • v.9 no.4
    • /
    • pp.47-56
    • /
    • 2018
  • This paper introduces an active power dependent standard characteristic curve, Q(P) to compensate for voltage variations due to the output of distributed generation. This paper presents an efficient control method of grid-connected inverters by comparing and analyzing voltage variation magnitude and line loss according to the compensation method. Voltage variations are caused not only by active power, but also by the change of reactive power flowing in the line. In particular, the system is in a relatively remote place in a coastal area compared with existing power plants, so it is relatively weak and may not be suitable for voltage control. So, since it is very important to keep the voltage below the normal voltage limit within the specified inverter capacity and to minimize line loss due to the reactive power. we describe the active power dependent standard characteristic curve, Q(P) method and verify the magnitude of voltage variation by simulation. Finally, the characteristics of each control method and line loss are compared and analyzed.

A Performance Improvement Method of PMSM Torque Control Considering DC-link Voltage Variation (DC-link 전압변동을 고려한 PMSM 토크제어의 성능 향상 방법)

  • Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.112-122
    • /
    • 2014
  • This paper proposes a PMSM torque control method considering DC-link voltage variation and friction torque. In general EV/HEV application, two dimensions look-up table(2D-LUT) is used for reference current generation due to its stable and robust torque control performance. Conventionally, this 2D-LUT is established by flux-torque table to overcome the DC-link voltage variation. However, the flux table establishment is more complex than the speed table establishment. Moreover, one flux data reflects several speed conditions in variable DC-link voltage, friction torque cannot be considered by using the flux table. In this paper, speed-torque 2D-LUT is used for current reference generation. With this table, PMSM torque control is well achieved regardless of DC-link voltage variation by the proposed control method. Simulation and experimental results validate improvement of torque control error through friction torque compensation.

Realtime Compensation of PCC Voltage Variation by Injection of Required Reactive Power in a Grid Connected Variable Speed Wind Turbine (계통 연계형 가변속 풍력발전기의 무효전력 주입을 통한 PCC 전압 변동량 실시간 보상)

  • Im, Ji-Hoon;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.69-74
    • /
    • 2010
  • In a grid connected variable speed wind turbine, the PCC voltage and the wind power fluctuate as the wind velocity changed. And this voltage variation is changed due to location of PCC. This paper calculate the value of PCC voltage variation which is proportional to the product of the line impedance from the ideal generator to the PCC and the wind turbine output current. And to reduce this PCC voltage variation, this paper calculate the required reactive power analytically using the vector diagram method. Output reactive current is changed, if the reactive current is limited by inverter capacity or grid code have the margin of voltage variation. If the grid connected inverter is controlled by proposed algorithm, the PCC voltage variation is minimized though the wind turbine output change at random. To verify calculated voltage variation and required reactive power, this paper utilized Matlab and PSCAD/EMTDC simulation and real small wind turbine and power system in Sapsido, island in the Yellow Sea.