• 제목/요약/키워드: Voltage sag

검색결과 366건 처리시간 0.021초

단선 AT 급전계통의 전차선-레일 단락 고장전류 분석 (The Analysis of Trolley-Rail Short Circuit Current in a Single Track AT Feeding System)

  • 조규정;류규상;이훈도;허승훈;김철환;권성일;김철환
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1659-1665
    • /
    • 2015
  • In general, AT(Auto-transformer) is used to improve voltage sag and inductive interference in power lines and communication lines in AC electrical railway feeding system. Especially, Korean AT feeding system has different composition compared to other countries like Japan or France, so that it has some special characteristics. However, relays imported from other countries have been used in Korea, and settings of these relays should be modified and reflect distinct characteristics of Korean AT feeding system. Therefore, study about fault analysis based on modeled AT feeding system is important. In this paper, we modeled a single track AT feeding system by using PSCAD and analyzed fault current flow in case of trolley-rail short circuit fault. Finally, we presented current magnitude of each branch expressed by boosting current of AT.

Characterization of GaN on GaN LED by HVPE method

  • Jung, Se-Gyo;Jeon, Hunsoo;Lee, Gang Seok;Bae, Seon Min;Kim, Kyoung Hwa;Yi, Sam Nyung;Yang, Min;Ahn, Hyung Soo;Yu, Young Moon;Kim, Suck-Whan;Cheon, Seong Hak;Ha, Hong Ju;Sawaki, Nobuhiko
    • Journal of Ceramic Processing Research
    • /
    • 제13권spc1호
    • /
    • pp.128-131
    • /
    • 2012
  • The selective area growth light emitting diode on GaN substrate was grown using mixed-source HVPE method with multi-sliding boat system. The GaN substrate was grown using mixed-source HVPE system. Te-doped AlGaN/AlGaN/Mg-doped AlGaN/Mg-doped GaN multi-layers were grown on the GaN substrate. The appearance of epi-layers and the thickness of the DH was evaluated by SEM measurement. The DH metallization was performed by e-beam evaporator. n-type metal and p-type metal were evaporated Ti/Al and Ni/Au, respectively. At the I-V measurement, the turn-on voltage is 3 V and the differential resistance is 13 Ω. It was found that the SAG-LED grown on GaN substrate using mixed-source HVPE method with multi-sliding boat system could be applied for developing high quality LEDs.

선택성장영역 크기에 따른 InGaN/GaN 다중양자우물 청색 MOCVD-발광다이오드 소자의 특성 (The characteristic of InGaN/GaN MQW LED by different diameter in selective area growth method)

  • 배선민;전헌수;이강석;정세교;윤위일;김경화;양민;이삼녕;안형수;김석환;유영문;하홍주
    • 한국결정성장학회지
    • /
    • 제22권1호
    • /
    • pp.5-10
    • /
    • 2012
  • 일반적으로 mesa 구조의 발광다이오드 제작은 MOCVD법으로 수행되고 있다. 특히 개개의 발광다이오드 칩을 식각하고 분리하기 위해서 발광다이오드는 반응성이온식각(RIE)공정과 절단(scribing) 공정을 거치게 된다. 플라즈마를 이용한 건식식각공정인 RIE 공정은 결함, 전위, 표면의 댕글링 본드 형성과 같은 몇 가지 문제점을 유발하고, 이러한 이유로 인해 소자 특성을 저하시킨다. 선택영역성장법은 사파이어 기판 위에 고품질의 GaN 에피층을 성장시키는 방법으로써 주목받고 있다. 본 논문에서는 고품질의 막을 제작하고 공정을 간소화하기 위해서 선택영역성장법을 도입하였고, 기존의 발광다이오드 특성에 영향을 주지 않는 선택영역의 크기를 규정하고자 한다. 실험에 사용된 원형의 선택성장영역의 직경크기는 2500, 1000, 350, 200 ${\mu}m$이고, 선택성장 된 발광다이오드의 소자 특성을 얻고자 SEM, EL, I-V 측정을 시행하였다. 주된 발광파장의 위치는 직경크기 2500, 1000, 350, 200 ${\mu}m$에서 각각 485, 480, 450, 445 nm로 측정되었다. 직경 350, 200 ${\mu}m$에서는 불규칙한 표면과 기존 발광다이오드보다 높은 저항 값을 얻을 수 있었지만, 직경 2500, 1000 ${\mu}m$에서는 평탄한 표면과 앞서 말한 350, 200 ${\mu}m$의 특성보다 우수한 전류-전압 특성을 얻을 수 있었다. 이러한 결과들로 기존 발광다이오드의 특성에 영향을 주지 않는 적당한 선택성장 직경크기는 1000 ${\mu}m$ 이상임을 확인하였다.

Performance Evaluations of Four MAF-Based PLL Algorithms for Grid-Synchronization of Three-Phase Grid-Connected PWM Inverters and DGs

  • Han, Yang;Luo, Mingyu;Chen, Changqing;Jiang, Aiting;Zhao, Xin;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1904-1917
    • /
    • 2016
  • The moving average filter (MAF) is widely utilized to improve the disturbance rejection capability of phase-locked loops (PLLs). This is of vital significance for the grid-integration and stable operation of power electronic converters to electric power systems. However, the open-loop bandwidth is drastically reduced after incorporating a MAF into the PLL structure, which makes the dynamic response sluggish. To overcome this shortcoming, some new techniques have recently been proposed to improve the transient response of MAF-based PLLs. In this paper, a comprehensive performance comparison of advanced MAF-based PLL algorithms is presented. This comparison includes HPLL, MPLC-PLL, QT1-PLL, and DMAF-PLL. Various disturbances, such as grid voltage sag, voltage flicker, harmonics distortion, phase-angle and frequency jumps, DC offsets and noise, are considered to experimentally test the dynamic performances of these PLL algorithms. Finally, an improved positive sequence extraction method for a HPLL under the frequency jumps scenario is presented to compensate for the steady-state error caused by non-frequency adaptive DSC, and a satisfactory performance has been achieved.

DFIG 고정자의 계통연계시 인덕턴스 변동을 고려한 가변이득 전류제어기 (Variable Gain Current Controller Considering Inductance Variations after the Connection of DFIG Stator to the Grid)

  • 신수철;유재성;홍정기;서인영;송승호
    • 전력전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.293-298
    • /
    • 2009
  • 본 논문은 이중여자 풍력발전기를 안정적으로 계통에 투입하는 알고리즘을 제안하였다. 발전기가 계통과 연계되는 순간 발전기의 내부 파라미터 값의 변동이 발생하며, 이는 계통 투입 전 발전기 파라미터에 근거한 RSC(Rotor Side Converter)측 전류제어기 이득 값에 영향을 준다. 이러한 영향으로 인하여 계통 투입 시 전류제어가 불안정하게 되거나, 전류제어 응답성이 낮게 된다. 따라서 계통투입 전 발전기 파라미터를 이용한 전류제어기 이득 값은 투입 후 바뀌어야 한다. 특히 회전자 전류제어기 성능은 순간 저전압 발생등 예상하지 않은 외란에 대하여 빠른 응답성을 필요로 한다. 따라서 본 논문에서는 계통투입 전 후의 RSC측 전류제어기의 이득 값을 달리하여 안정적인 계통 투입이 가능하도록 하는 알고리즘을 시뮬레이션과 실험으로 증명하였다.

중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발 (Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor)

  • 정현규;이동훈;이윤상;허형;정용무
    • 비파괴검사학회지
    • /
    • 제24권2호
    • /
    • pp.164-170
    • /
    • 2004
  • 중수로 내부구조물 중 칼란드리아관(CT)와 액체주입노즐관(LIN)은 서로 수평으로 90도 교차되게 배열되어 있으며 원자로 내의 열, 방사선, 하중에 의해 creep 현상이 발생되어 처짐이 일어난다. 칼란드리아관은 액체주입노즐관과 동일 재료이나 운전 온도와 방사선 조사량으로 인해 액체주입노즐관에 비해 상당히 열악한 조건에 노출되어 있으므로 처짐이 심각할 것으로 예상된다. 만약 두 관의 접촉이 발생되면 원전 안전성에 영향을 미칠 것이므로 인접관에 대한 접촉여부 점검은 중수로 안전현안 중 하나이다. 이러한 접촉여부를 확인하기 위하여 핵연료채널 내부로 탐촉자를 삽입하여 인접관과의 교차점에서 간격을 직접측정하기 위한 방법으로 원거리장 와전류검사 (RFECT) 기술을 적용하였다. 핵연료채널 인접관인 액체주입노즐관 신호 취득시 발생 가능한 잡음 신호(두께변화, Lift-off, 수축)에 대해 체적적분법에 의한 모델링으로 조사하였고, 신호와 잡음과의 분리 가능한 조건을 확인하였다. 원거리장 와전류검사 적정 조건은 민감도와 투과력 그리고 잡음신호 등을 동시에 고려하여 주파수 1kHz와 코일간격 200m로서 결정하였다. 원거리장 와전류검사 실험 결과 칼란드리아관과 액체주입노즐관 사이의 간격 변화에 대한 신호 특성을 전압평면을 이용하여 상관관계를 도출하였다.