• Title/Summary/Keyword: Voltage sag

Search Result 366, Processing Time 0.028 seconds

Customer's Effects of Momentary Voltage Sag in Power Distribution System Considering Reclosing Interval (리클로징 시간을 고려한 배전계통 순간전압강하의 수용가측 영향)

  • Moon, Jong-Fil;Kim, Jae-Chul;Kang, Bong-Seok;Yun, Sang-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.36-38
    • /
    • 2003
  • In this paper, It was evaluated that the customer's effects of momentary voltage sag in power distribution system considering reclosing interval. Above all, power quality problems were discussed widely, various international standards about power quality were compared to each other. after the continuous voltage sag waves of power distribution system on fault were induced, the experimentation about voltage sag for critical load was performed using source simulator. The results of experimentation were displayed as the form of 2 and 3-dimensional CBEMA Curve.

  • PDF

Three-Phase Z-Source Dynamic Voltage Restorer with a Fuel Cells Source (연료전지 전원을 갖는 3상 Z-소스 동적 전압 보상기)

  • Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.41-48
    • /
    • 2008
  • This paper proposes a three-phase Z-source dynamic voltage restorer (Z-DVR) to mitigate the voltage sag for the critical loads. The proposed system is composed of passive filter and Z-source topology inverter. As an ESS(Energy Storage System) of the proposed system is employed the Proton Exchange Membrane Fuel Cells (PEMFC). To calculate and control the harmonics and compensation voltage, $i_{d}-i_{q}$ theory in dq rotating reference frame and PI controller are used. In case that three-phase voltage sags occurred, a PSIM simulation was done for the performance comparison of the conventional method employed battery stacks and proposed method. As a result, considering the voltage compensation performance, each method was nearly similar. Also, the compensation performance and the %THD(%Total Harmonic Distortion) result under the various source voltage conditions (sag or swell) were presented and discussed to show the performance of the proposed system.

Dynamic Voltage Restorer Control Using $H_{\infty}$ Algorithm ($H_{\infty}$ 알고리즘을 이용한 Dynamic Voltage Restorer의 제어)

  • Chun, Yeong-Han;Kim, Ji-Won;Jeon, Jin-Hong
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.12
    • /
    • pp.561-565
    • /
    • 2001
  • Recent trend of increasing automated factories needs supply of high quality power from the utilities. Among the items of the power quality, voltage sag can be compensated by Dynamic Voltage Restorer(DVR). The key feature of the DVR is high response with less transient period to recover from the voltage sag due to the lightning or line-to-ground faults. In this paper we report that $H_{\infty}$ controller is very promising for the practical application to the controller of DVR. Experimental results shown in this paper was obtained by applying the control algorithm to 20 kVA DVR system. The experimental set consists of IGBT-based three phase inverter and the TMS320C32-60 DSP used for main processor of the control board. To simulate the 50% voltage sag, the SCR-based experimental set was constructed.

  • PDF

Detection of Voltage Sag using An Adaptive Extended Kalman Filter Based on Maximum Likelihood

  • Xi, Yanhui;Li, Zewen;Zeng, Xiangjun;Tang, Xin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1016-1026
    • /
    • 2017
  • An adaptive extended Kalman filter based on the maximum likelihood (EKF-ML) is proposed for detecting voltage sag in this paper. Considering that the choice of the process and measurement error covariance matrices affects seriously the performance of the extended Kalman filter (EKF), the EKF-ML method uses the maximum likelihood method to adaptively optimize the error covariance matrices and the initial conditions. This can ensure that the EKF has better accuracy and faster convergence for estimating the voltage amplitude (states). Moreover, without more complexity, the EKF-ML algorithm is almost as simple as the conventional EKF, but it has better anti-disturbance performance and more accuracy in detection of the voltage sag. More importantly, the EKF-ML algorithm is capable of accurately estimating the noise parameters and is robust against various noise levels. Simulation results show that the proposed method performs with a fast dynamic and tracking response, when voltage signals contain harmonics or a pulse and are jointly embedded in an unknown measurement noise.

Analysis on Bus Voltage Sag in Power Distribution System with SFCL according to Interconnected Locations of Small DG (초전도 한류기 적용시 소형 분산전원시스템의 연계 위치에 따른 배전계통의 전압강하 분석)

  • Moon, Jong-Fil;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.210-215
    • /
    • 2013
  • This paper analyze the bus voltage sags in the power distribution system with a small scale cogeneration system when the superconducting fault current limiter was introduced. Among the solutions to decrease the short-circuit current considering the locations of the small scale cogeneration system, the superconducting fault current limiter (SFCL) has been announced as one of the promising methods to reduce the fault current because the installation of the small scale cogeneration system which increases the short-circuit current. According to the application locations of the small scale cogeneration system in a power distribution system, it has caused the variations of voltage sag and duration which depends on the change of the short-circuit current, which can make the operation of the protective device deviate from its original set value when the fault occurs. To investigate the voltage sag when a SFCL was applied into a power distribution system where the small scale cogeneration system was introduced into various locations, the SFCL, small scale cogeneration system, and power system are modeled using PSCAD/EMTDC. In this paper, the effects on voltage sags are assessed when the SFCL is installed in power distribution system with various locations of the small scale cogeneration system.

An Improved Detection Technique for Voltage Sag using the Wavelet Transform

  • Kim, Chul-Hwan;Lee, Jong-Po;Ahn, Sang-Pil;Kim, Byung-Chun
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.1-8
    • /
    • 2001
  • This paper presents a discrete wavelet transform approach for detecting voltage sags initialized by fault conditions and starting of larger motors. The proposed technique is based on utilizing the summation value of D1(at scale 1) coefficients in multiresolution analysis(MRA) based on the discrete wavelet transform. In this paper, the proposed technique is tested under various cases of voltage sags. It is shown that the voltage sag detection technique based on the wavelet transform is a satisfactory and reliable method for detecting voltage sags in power quality disturbance analysis.

  • PDF

Optimal Placement of Distributed Generation Units Considering Voltage Sags (순간전압강하를 고려한 분산전원 최적위치 선정)

  • Song, Young-Won;Lee, Kyebyung;Park, Chang-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1505-1510
    • /
    • 2013
  • This paper presents a method for determining the optimal placement of distributed generation units considering voltage sags. In general, the existing methods for distributed generation placement do not consider power quality problems such as voltage sags. In this paper, a novel method based on both genetic algorithm and voltage sag assessment is proposed for determining the placement of distributed generation unit. In the proposed method, the optimal placement is determined to minimize voltage sag effects and system losses.

Design and Implementation of Boost Type Single Phase Inverter System for Compensation of Voltage Sag (전압강하 보상을 위한 승압형 단상 인버터 시스템의 설계 및 구현)

  • Lee, Seung-Yong;Seo, Young-Min;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.219-220
    • /
    • 2011
  • In this paper, 300[W] class boost type single phase inverter system which can compensate voltage sag was designed. If the voltage sag has appeared in input voltage, the boost converter would be operated to compensate it. The system is designed for that the THD of ouput voltage is below 5[%] and steady state error of output voltage is below 1[%]. The system was verified through experiments.

  • PDF

Boost Type Inverter System for Compensation of Instantaneous Voltage Sag (입력전압의 순시전압강하 보상을 위한 승압형 인버터 시스템)

  • Lee, Seung-Yong;Seo, Young-Min;Koo, Do-Youn;Kim, Dong-Wook;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.49-50
    • /
    • 2010
  • In this paper, we propose a boost type inverter system for the compensation of instantaneous voltage sag. The system compensate instantaneous voltage sag which magnitude is higher than 10[%] of normal input voltage. When input voltage is higher than 90[%] of normal value, the switch in boost converter is not operated and output voltage is controlled by modulation amplitude in PWM inverter.

  • PDF

The Characteristics of Voltage Sag and a Study about Detection Algorithm Using the DQ Transformation (Voltage sag의 특성과 dq좌표변환을 이용한 검출법에 대한 연구)

  • Kim, Yong-Sang;Kim, Do-Hun;Yim, Sang-Wook;Lee, Kyo-Sung;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1114-1116
    • /
    • 2003
  • Voltage sags are known as a serious problem causing mal-operation of equipment like computers, process controllers and adjustable-speed drives. In this paper, characterization of voltage sag and an overview of methods used in the mitigation of voltage sags are presented. Moreover a fast detection method for voltage disturbances is explored. The algorithm is based on the theory that allows a set of three-phase voltages be converted the d-q value. The utility input voltages are sensed and then converted to some quantities in the d-q transformation. And the difference between reference value and input value are showed that some disturbances happened in the system.

  • PDF