• 제목/요약/키워드: Voltage regulator

검색결과 411건 처리시간 0.024초

Optimal Coordination of Intermittent Distributed Generation with Probabilistic Power Flow

  • Xing, Haijun;Cheng, Haozhong;Zhang, Yi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2211-2220
    • /
    • 2015
  • This paper analyzes multiple active management (AM) techniques of active distribution network (ADN), and proposes an optimal coordination model of intermittent distributed generation (IDG) accommodation considering the timing characteristic of load and IDG. The objective of the model is to maximize the daily amount of IDG accommodation under the uncertainties of IDG and load. Various active management techniques such as IDG curtailment, on-load tap changer (OLTC) tap adjusting, voltage regulator (VR) tap adjusting, shunt capacitors compensation and so on are fully considered. Genetic algorithm and Primal-Dual Interior Point Method (PDIPM) is used for the model solving. Point estimate method is used to simulate the uncertainties. Different scenarios are selected for the IDG accommodation capability investigation under different active management schemes. Finally a modified IEEE 123 case is used to testify the proposed accommodation model, the results show that the active management can largely increase the IDG accommodation and penetration.

배전계통의 분포 부하 모델링을 통한 최적화 IVVC 알고리즘 (Integrated Volt/Var Control Algorithm based on the Distributed Load Modeling of Distribution Network)

  • 김영인;임일형;최면송;이승재;이성우;권성철
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1463-1471
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

발전기 과여자 및 과전압 계전기 보호협조에 관한 연구 (A Study on the Protective Coordination of Generator Overexcitation and Overvoltage Relay)

  • 박지경;김광현;김철환;유영식;양정재
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1187-1194
    • /
    • 2017
  • After North American wide area black out on August 14, 2003, various studies have been conducted to find out the reason of the disaster. One of main reasons was misoperation of generator protection system. Since then, protective coordination between generator protection system and excitation system controls has been hot issue among electrical engineers. Among various generator protection relays, in this paper, we focused on generator overvoltage and overexcitation relay, which protect the over-flux condition of the generator. Thus, at first, we modeled the generator overvoltage, overexcitation relay and detailed power system including excitation system, governor and etc., based on actual field data. And then, we reviewed the protective coordination of generator overvoltage and overexcitation relay using electromagnetic transient program. In addition, we discussed the protective coordination method for redundant protection relays in both automatic voltage regulator and generator side.

3상 전류평형 제어기술 적용장치 개발 (A Development of 3 Phase Current Balance Control Unit)

  • 천영식;성형수;원학재;한정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1088-1090
    • /
    • 2001
  • In general, Power SCR(Silicon Controlled Rectifier) is most widely used in Power Plant as well as Industrial field. It has been controlled and operated according to its own control method. Especially, in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control unit is described, it gets over the past analog control system limit, uses DSP(Digital signal processor) had high speed response, controls SCR gate firing angle for 3 phase current balance.

  • PDF

Stability Region Evaluation of Control Inputs by Fuzzy-Ttype Lyapunov Function for Nonlinear Control System

  • Kuwata, Akihiko;Kawamoto, Shunji;Kanetaka, Iwao;Takino, Katsuhiko;Ishigamr, Atsushi;Taniguchi, Tsunco;Tanaka, Hiroyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.416-421
    • /
    • 1994
  • Electric Power system is a large scale nonlinear control one. Therefore, nonlinear control is desirable for the stabilizing, and it is thought that to establish an analytical method for optimal control inputs of AVR(automatic voltage regulator) and GOV(governor) is an important subject. In this paper, as a simple case, one-machine infinite-bus electric power model system with GOV is treated under the three kinds of control inputs; (i) fuzzy control input, (ii) linear control input and (iii) no control input. Next, the stability for each case is analyzed, and the three-dimensional stability regions and control responses are evaluated and compared. Finally, it is concluded that the linear control input does not necessarily give a good region and response, and the fuzzy one is better than others.

  • PDF

황색종 Bulk건조시 송풍량 조절에 따른 건조엽의 물리성 변화 (Effect of Air Flow During Curing Process on Physical Properties of Bulk Cured Leaves)

  • 이철환;진정의;한철수
    • 한국연초학회지
    • /
    • 제21권1호
    • /
    • pp.5-9
    • /
    • 1999
  • In recent years, the line of increase in policy on tobacco production triggered a rise in the loading volume per bulk curing barn, and manufacturers boosted the output of their blowers in order to prevent dirty leaves in the process of curing. for this reason, we studied the effect of the reducing air flow in bulk curing chamber from the color fixing stage to the stem drying stage of flue curing process on physical properties of cured leaves. The control of air flow was composed of the reducing air velocity of blower by means of a voltage regulator (slidac), and condition before color fixing stage was all the same with the conventional curing method. As a result, an effectiveness of improvement in the physical properties of cured leaves were observed. The leaves cured by this method were somewhat orange in color of upper stalk position, better bodied, and less brittle compared with the leaves produced by conventional curing. However, the leaves cured by this method had a little sharpness and harshness. As to the physical properties, there was decreased in occurrence of flat leaves than that of conventional ones. On the other hand, in case of reducing air flow during the curing process, increase of price per kg reached to about 5 % compared with those of conventional curing method.

  • PDF

AC Chopper 3전극 방식의 듀티비에 따른 $CO_2$ 레이저 출력 특성에 관한 연구 (A Study on the Output Characteristics of AC Chopper Duty-Ratio $CO_2$ Laser System using 3 Electrode-type and Ring Blower)

  • 박성준;정현주;김근용;이유수;김휘영;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1697-1699
    • /
    • 2001
  • In this paper, the circuit of AC Choppers for $CO_2$ laser power supply are proposed and investigated. IGBT-controlled ac voltage regulators, operating at high frequency chopping mode. Chopping-to-supply duty ratio plays an important role in terms of laser output. Laser input energy is varied by controlling the leakage transformer used with the proposed system. This improved circuit employs a 3 electrode - type and Ring Blower. This improved circuit system has many advantages compared with the conventional SMPS such as simple design requirement, easy implementation, high reliability, low switching loss, and consequently high efficiency. As a result, the maximun output was 16W at duty-ratio of 92%, total gas mixture of $CO_2$ : $N_2$ : He = 1 : 9 : 15, total pressure of 15torr.

  • PDF

원추형 자기 베어링 지지 무마찰 구동장치의 위치제어 (Position control of the frictionless positioning device suspended by cone-shaped active magnetic bearings)

  • 정호섭;이종원
    • 제어로봇시스템학회논문지
    • /
    • 제2권3호
    • /
    • pp.181-187
    • /
    • 1996
  • A frictionless positioning device using cone-shaped active magnetic bearings(AMBs) is developed, which is driven by a brushless DC motor equipped with resolver. The cone-shaped AMB feature that the structure is simple and yet the five d.o.f. rotor motion is controlled by four magnet pairs. A linearized dynamic model, which accounts for the relationship between input voltage and output current in the cone-shaped magnet, is developed and the azimuth motion of the frictionless positioning device is modeled as the second order system. The feedback controller is designed by using linear quadratic regulator with integral action optimal control law so that the cone-shaped AMB system is stabilized and the frictionless positioning device gets the zero steady state. It is observed that the linearized dynamic model is adequate and the frictionless positioning device can achieve the tracking accuracy within the sensor resolution.

  • PDF

Full CMOS Single Supply PLC SoC ASIC with Integrated Analog Front-End

  • Nam, Chul;Pu, Young-Gun;Kim, Sang-Woo;Lee, Kang-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권2호
    • /
    • pp.85-90
    • /
    • 2009
  • This paper presents a single supply PLC SoC ASIC with a built-in analog Front-end circuit. To achieve the low power consumption along with low cost, this PLC SoC employs fully CMOS Analog Front End (AFE) and several LDO regulators (LDOs) to provide the internal power for Logic Core, DAC and Input/output Pad driver. The receiver part of the AFE consists of Pre-amplifier, Gain Amplifier and 1 bit Comparator. The transmitter part of the AFE consists of 10 bit Digital Analog Converter and Line Driver. This SoC is implemented with 0.18 ${\mu}m$ 1 Poly 5 Metal CMOS Process. The single supply voltage is 3.3 V and the internal powers are provided using LDOs. The total power consumption is below 30 mA at stand-by mode to meet the Eco-Design requirement. The die size is 3.2 $\times$ 2.8 $mm^{2}$.

다출력 전원회로의 안정화를 위한 자기증폭기의 특성해석 (Analysis on the Characteristics of Magnetic Amplifier for Multi-output Postregulation)

  • 김철진;이관용;홍대식;김영태;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.133-135
    • /
    • 2004
  • As a result of the recent advances in magnetic materials, the Magnetic Amplifier(Magamp) technique is one of the reliable and cost-effective postregulation method for multiple-output power supply. This is true for high-current postregulated output since at highter output current the efficiency of linear postregulation is unacceptably low, while the complexity of more efficient switch mode postregulator is associated with a significant cost. Magamp have some advantages of higher power density, simple control circuit, good regulation, high frequency and high performance. In this paper, Operation principle of proposed approach and a performance of magamp control circuit with TL431 is described. The comparative analysis of magamp circuit and buck regulator circuit with 20W load condition is conducted. Experimental verifications on multi-output flyback converter are conducted. Simulations and experimental results show that the proposed approach is efficiency and voltage regulation of the auxiliary output is excellent.

  • PDF