• 제목/요약/키워드: Voltage measuring system

검색결과 357건 처리시간 0.032초

대전력 시험전압 측정방법에 대한 고찰 (The study of test voltage measuring system for high-power testing laboratory)

  • 노창일;나대열;김선구;정흥수;김원만;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1038-1040
    • /
    • 2005
  • This paper describes the optimal design, construction and performance evaluation of voltage divider used in high power testing laboratory for voltage measuring system. These dividers, which are of R, C, R&C type voltage dividers, the voltage to be measured range from voltage to several ten kilovolts, the frequency of the signals has a bandwidth from DC to megaHertz Measuring transient voltage and currents in the high voltage power laboratory is generally accompanied by electromagnetic interface and induced noise. above all, the measuring capabilities of voltage measuring system are dependent upon short response time and it must be as free as possible of inductive effects. In this paper presents both characteristic of voltage divider and design of voltage measuring system.

  • PDF

시험소 충격전압 측정시스템의 소급성검토 (Review of the tracebility of impulse voltage measuring system in test laboratory)

  • 허종철;최익순;정주영;반석걸;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1632-1634
    • /
    • 2003
  • For lihgtning and switching impulse voltage performances in laboratories, impulse voltage measuring system, which is consisted of voltage divider, recording instrument and connecting system between divider and recording instrument, is used. In order to show reliability of test result in test laboratory, tracebility of these measuring system to be using in test laboratory is needed. In this paper, we describe tracebility and uncertainty of impulse voltage measuring system in test laboratory.

  • PDF

포켈스 소자를 이용한 고전압 임펄스 및 미소신호 측정기술 개발 (Development of Measuring Techniques for High Voltage Impulse and Small Signals using Pockels Cell)

  • 홍진영;이정헌;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1571-1573
    • /
    • 1994
  • In order to substitute for the conventional measuring system which could bring about technical inconveiences, measuring techniques for the fast transient high voltage upto 100 kV and small signals less than 1 V are developed by use of Laser Source with Packets cell. for the former, capacitive voltage divider was specially designed for reducing the impulse voltage less than the half-wave voltage of pockets cell. For the tatter, interferometer type was employed as a mean to removing the fluctuation of Laser output intensity. And also the main beam through the Pockels cell and the reference beam from the Laser source are seperated before being detected respectively by photo diodes. And then, these two signals are amplified and compared for detecting only the small signals applied across the Pockels cell. Throughout this work, Laser-based measuring system is likely to enable us, at this moment, to detect correctly lightning impulse voltage upto 100 kV and the small signals less than 1 V upto the 2 MHz. Such a system could be employed as a possible diagnostic measuring system at the substation.

  • PDF

부싱형 커패시터를 이용한 고전압 계측시스템에 관한 연구 (A study on high-voltage measuring system using bushing-type capacitor)

  • 강문성;심형관;유충현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.502-507
    • /
    • 1999
  • An improved, accurate and reliable high-voltage measuring system utilizing a bushing-type capacitor is proposed in this study. This system measures voltages and phase angles of three-phase 22.9 kV power distribution lines and provides enough current to charge a battery for a motor-driven load switch and to operate the measuring and communication circuits for the distribution automation. For reliability, epoxy resin was used as the dielectric material of the bushing-type capacitor since the dielectric strength of epoxy resin is very stable over the wide range of temperature. Capacitances were investigated and found to be stable over the wide range of temperature and applied voltage, and the results indicate that the proposed measurement system is very reliable.

  • PDF

도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험 (Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway)

  • 정호성;신승권;김형철;박종영
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.

표준측정시스템과의 비교시험을 통한 교류전압 측정시스템의 소급성 확보 (Comparison of AC Voltage Measuring System)

  • 최익순;김석수;허종철;김민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1779-1781
    • /
    • 2003
  • For reliability of high voltage test results in test laboratory, traceability of measuring systems is to be needed. In this paper, it deals with traceability and uncertainty of AC voltage measuring system which is tested by comparison with reference divider.

  • PDF

부하개폐기용 고전압 계측제어 장치에 관한 연구 (A Study on the High-Voltage Measuring & Control System for a Load Switch)

  • 박정훈;홍성훈;강문성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.757-759
    • /
    • 1998
  • This paper proposes a new high-voltage measuring system that is able to provide current enough to charge a storage battery for a motor driving a load switch, and detect each phase voltage and phase angle in three phase distribution line accurately. In order to develop the reliable voltage measuring system we had designed and manufactured condenser-type bushing having good characteristics for temperature on account of using epoxy resin as dielectric material, and investigated the variation characteristics of capacitance via variation of applied voltage. The experiment results show that the proposed condenser has good characteristics to environmental changes.

  • PDF

KDP Pockels 소자를 이용한 고전압 펄스 측정 (Measurement of High Voltage Pulse using a KDP Pockels Cell)

  • 조광래;이정헌;장용무;구자윤;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.566-568
    • /
    • 1993
  • A measuring technique for the fast transient high voltage is under development by use of laser source in order to substitute for the conventional measuring system which could bring about several technical inconveniences. At this moment, this work is aimed to construct a compact measuring system with the use of Pockels cell and specially designed voltage divider. This system is likely to enable us to measure the lightening impulse voltages at the level of 30kV, 50kV and 70kV. Throughout this work, qualified measuring devices are required to be developed for discriminating different kinds of noise from which the system should be protected.

  • PDF

뇌충격전압 측정시스템의 국제 비교시험-II (Intercomparison of Ll measurement system of KERI)

  • 김익수;정주영;최재구;김익균;신영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1555-1557
    • /
    • 2001
  • To compare the lightning impulse measurement capabilities of high voltage laboratory, a lightning impulse voltage measuring system from HUT is circulated around the world. This paper presents test results after second round of this worldwide exercise. KERI's impulse voltage measuring system compared with the circulating reference measuring system from HUT at voltage levels of 80, 160, 240, 320 and 400 kV. Three impulse shapes were used, i.e. full smooth lightning impulse with both short (0.84 $\sim$ 0.95 ${\mu}s$) and long front (1.45 $\sim$ 1.56 ${\mu}s$), and chopped impulse with time to chopped impuse. Impulse peak value ($U_p$) and time parameters ($T_1$, $T_2$ and $T_c$) according to IEC 60060-1 were compared.

  • PDF