• 제목/요약/키워드: Voltage drop rate

검색결과 65건 처리시간 0.017초

전기수력학적 미립화에서 액적 형성에 영향을 미치는 인자에 관한 실험적 연구 (A Study on Influence Factors on Drop Formation in Electrohydrodynamic Atomization)

  • 성기안;이창식
    • 한국분무공학회지
    • /
    • 제8권2호
    • /
    • pp.24-30
    • /
    • 2003
  • An experimental study was performed to investigate the influence factors of drop formation in electrohydrodynamic atomization. The mode of electrohydrodynamic atomization depended on the various factors such as the flow rate of the liquid, the inner diameter of the nozzle, the distance between the nozzle tip and the ground electrode, the shape of the ground electrode. and the applied high voltage. This work was performed to investigate the experimental analysis for the flow pattern visualization of droplets, and the relationship between voltage application and the behavior of liquid atomization. Uniform drops of different sizes can be obtained at the inception of the spindle mode by charging the flow rate and the electric field. The drop size also decreased when the flow rate was raised for the spindle mode. The whipping motion occurred beyond 7kV and before the corona started to take effect.

  • PDF

디지털 통신 응용을 위한 $MnO_2$, Pseudo-capacitor의 시스템 설계 및 성능평가 (System Design and Performance Analysis of $MnO_2$ Pseudo-capacitor for Digital Communication Applications)

  • 성우경;홍명신;김선욱
    • 전기화학회지
    • /
    • 제3권4호
    • /
    • pp.241-245
    • /
    • 2000
  • 비정질 $MnO_2\;nH_2O$ 전극재료를 사용한 pseudo-capacitor를 설계 제작하여 특성을 평가하였다. 100mV/s의 cyclic voltammogram으로부터 측정한 결과, 이 전극재료의 안정한 potential window는 1V이고 비용량은 250F/g이었다. TDMA(Time Division Multiplex Algorithm) pulse 시험에서 TDMA 시스템 (2 parallel-pseudo-capacitor systems) 은 0.22V의 ohmic voltage drop과 0.38V의 capacitor voltage drop을 보여주었다. 이 TDMA system의 total voltage drop이 0.60V이므로 TDMA 위성통신 휴대전화의 요건인 1V maximum voltage drop을 충족하였다. 또한, 이 system의 ESR과 비용량은 각각 $55m{\Omega}$과 105mF이었다. 따라서 이 TDMA system이 위성통신 휴대전화를 위한 load-leveling 캐패시터로 응용 가능함을 확인하였다.

직류전위차법을 이용한 결함검출에 관한 연구 (A Study on Detecting Flaws Using DC Potential Drop Method)

  • 배봉국;석창성
    • 대한기계학회논문집A
    • /
    • 제24권4호
    • /
    • pp.874-880
    • /
    • 2000
  • In this paper, a DC potential drop measurement system was used to find the position of the flaw on a simple thin plate. Four-point probe test was evaluated and used for this study. In the four-point probe test, the more distance between current pins provides the more measurable scope, the less voltage difference, and the more voltage difference rate. In the other hand, the more distance between voltage pins provides the less voltage difference and the less voltage difference rate. An optimized four-point probe was applied to measure the relation between voltage and the relative position of flaw to the probe. The Maxwell 21) simulator was used to analyze the electromagnetic field, and it showed that the analytical result was similar to the experimental result within 11.4% maximum error.

Study of Optimal Location and Compensation Rate of Thyristor-Controlled Series Capacitor Considering Multi-objective Function

  • Shin, Hee-Sang;Cho, Sung-Min;Kim, Jin-Su;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.428-435
    • /
    • 2013
  • Flexible AC Transmission System (FACTS) application study on enhancing the flexibility of AC power system has continued to make progress. A thyristor-controlled series capacitor (TCSC) is a useful FACTS device that can control the power flow by adjusting line impedances and minimize the loss of power flow and voltage drop in a transmission system by adjusting line impedances. Reduced power flow loss leads to increased loadability, low system loss, and improved stability of the power system. This study proposes the optimal location and compensation rate method for TCSCs, by considering both the power system loss and voltage drop of transmission systems. The proposed method applies a multi-objective function consisting of a minimizing function for power flow loss and voltage drop. The effectiveness of the proposed method is demonstrated using IEEE 14- and a 30-bus system.

Performance Analysis of a Three-Phase Parallel Active Power Filter which Compensates PCC Voltage and the Unbalanced Loads

  • Lee, Woo-Cheol;Lee, Taeck-Kie;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • 제1권1호
    • /
    • pp.9-18
    • /
    • 2001
  • The performance analysis of a three-phase parallel active power filter that compensates PCC voltage and the unbalanced loads is presented in this paper. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. Firstly, it operates as a conventional active filter with reactive power compensation when PCC voltage is within the 15% voltage drop range. Secondly, it operates as a voltage compensator when PCC voltage is not within the 15% voltage drop range. And both APF and voltage compensator compensate asymmetries caused by nonlinear loads. Finally, two methods of detecting the negative sequence are reviewed, and the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rate at 10KVA.

  • PDF

교류 고전압을 이용한 대전액체의 전기수력학적 미립화에 관한 실험적 연구 (An Experimental Study on the Electrohydrodynamic Atomization of Conducting Liquid Using the AC High Voltages)

  • 성기안
    • 한국분무공학회지
    • /
    • 제13권2호
    • /
    • pp.73-78
    • /
    • 2008
  • An experimental study was performed to explore the drop formation and atomization characteristics in electrohydrodynarnic atomization with flow rate, power supply, voltage frequency, and nozzle size. A basic electrohydrodynarnic atomizer equipment was developed for the analysis of spray visualization and tested for the exploration of relationship between several experimental parameters. In results, the varicose wave had been taken place and the small droplets had been generated less than outer diameter of nozzle on the conditions of 25G of nozzle, flow rate of 2 mL/min, and applied frequency of 50kV at AC power over 5kV voltage. The whipping motion had been grown at applied frequency of 400kV and AC power around 2kV voltage

  • PDF

Comparison of Metal Transfer Behavior in Electrodes for Shielded Metal Arc Welding

  • Xu, X.;Liu, S.;Bang, K.S.
    • International Journal of Korean Welding Society
    • /
    • 제4권1호
    • /
    • pp.15-22
    • /
    • 2004
  • Metal transfer behavior of three shielded metal arc welding electrodes, AWS El1018, E6013 and E6010, were investigated through the characterization of size distribution of droplets and measurement of arc voltage signals. Of the three electrodes, Ell018 electrode showed the largest droplet size with the smallest amount of spatter, while E6010 electrode showed the smallest droplet size with the largest amount of spatter. Even though Ell0l8 electrode showed a good agreement between the frequencies of voltage drop in FFT processed voltage signals and the transfer rate of droplets, E6013 and E6010 electrodes showed weaker correlation because of their dominant explosive transfer behavior. The type of cathode used and electrode baking time also influenced the metal transfer behavior. Compared to bead-on-plate welding using steel plate as a cathode, welding on a water-cooled copper pipe showed less short-circuiting and higher melting rate in all electrodes because of higher arc potential and/or anode drop. When baked for a long time, E6010 electrode showed much more stable arc with less short-circuiting and explosion due to the loss of gas formation ingredients.

  • PDF

Experimental Investigation of Electrostatic Dripping and Atomization Mode through Non-MEMs based Nozzle Design

  • Choi, Kyung-Hyun;Dang, Hyun-Woo;Rehmani, M.A. Ali
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 춘계학술발표대회
    • /
    • pp.13.2-13.2
    • /
    • 2009
  • Electrostatic printing either it is drop-on-demand or continuous has immense applications in non-contact printing systems such as solar cells, flexible printed circuits, RFIDs and bio applications. In this paper a laboratory manufactured nozzle has been designed for the experimental investigation of electrostatic dripping and atomization of liquid. Dripping and atomization conditions such as voltage, nozzle tip diameter, distance between counter electrode and flowrate has been indentified for the designed nozzle. Furthermore it is also demonstrated that the diameter of a generated droplet could be reduced from a significantly large size to a narrow size distribution which can be controlled by volumetric flow rate and applied voltage. This study will help in classify the conditions between different electrostatic dripping mode such as drop-on-demand formation, jet mode and finally the atomization mode based on the laboratory fabricated nozzle head.

  • PDF

Assessment of a Phase Doppler Anemometry Technique in Dense Droplet Laden Jet

  • Koo, Ja-Ye;Kim, Jong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1083-1094
    • /
    • 2003
  • This study represents an assessment of the phase-Doppler technique to the measurements of dense droplet laden jet. High-pressure injection fuel sprays have been investigated to evaluate the use of the Phase-Doppler anemometry (PDA) technique. The critical issue is the stability of the phase-Doppler anemometry technique for dense droplet laden jet such as Diesel fuel spray in order to insure the results from the drop size and velocity measurements are repeatable, consistent, and physically realistic because the validation rate of experimental data is very low due to the thick optical density. The effect of shift frequency is minor, however, the photomultiplier tube (PMT) voltage setting is very sensitive to the data acquisition and noise in dense droplet laden jet. The optimum PMT voltage and shift frequency should be chosen so that the data such as volume flux and drop diameter do not change rapidly.

전류 감지 회로를 이용한 빠른 과도응답특성을 갖는 capless LDO 레귤레이터 (Capless Low Drop Out Regulator With Fast Transient Response Using Current Sensing Circuit)

  • 정준모
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.552-556
    • /
    • 2019
  • 본 논문에서는 전류 제어 회로를 이용하여 load Transient response 특성을 향상시킨 capless LDO(low drop-out) 레귤레이터를 제안하였다. LDO 레귤레이터 내부의 오차증폭기와 패스 트랜지스터 사이에 전류 조절 회로를 두어 전압 라인에 들어오는 전류특성을 개선시켜 기존의 LDO 레귤레이터보다 향상된 transient 응답특성을 갖는다. 제안된 회로는 cadence의 virtuoso, spectre 시뮬레이터를 이용하여 0.18 um 공정에서 특성을 분석하였다. 실험 결과에 따르면, 제안된 회로 구성을 이용한 LDO의 load transient response는 기존 LDO과 비교하여 부하 전류가 rising time인 경우 1.954 us에서 1.378 us, falling time인 경우 19.48 us에서 13.33 us으로 약 29%, 28% 개선된 응답속도를 가진다.