• Title/Summary/Keyword: Voltage control strategy

Search Result 619, Processing Time 0.033 seconds

A New Overmodulation Strategy for PWM Inverter (PWM 인버터의 출력전압 향상을 위한 과변조 기법)

  • 김상훈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.13-18
    • /
    • 1999
  • This paper proposes a new overmodulation stategy to give a better voltage by the full utilization of the hexagon voltage range in the space vector PWM(SVPWM) inverter. This overmodulation strategy can apply to the vector control, leading to better output torque capability in the ac motor drive system. This strategy is that in the overmodulation range, the d-axis output current is given a priority to regulate the flux well, instead the q-axis output curent is sacrificed. Therefore, the vector control even in the overmodulation PWM operation can be achieved well. For this purpose, the d-axis output voltage of a current controller to control the flux is conserved. the q-axis output voltage to control the torque is controlled to place the reference voltage vector on the hexagon boundary in case of the overmodulation. The validity of the proposed overall scheme is confirmed by simulation and experiments for a 22[kW] induction motor drive system

Fault-Tolerant Control for 5L-HNPC Inverter-Fed Induction Motor Drives with Finite Control Set Model Predictive Control Based on Hierarchical Optimization

  • Li, Chunjie;Wang, Guifeng;Li, Fei;Li, Hongmei;Xia, Zhenglong;Liu, Zhan
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.989-999
    • /
    • 2019
  • This paper proposes a fault-tolerant control strategy with finite control set model predictive control (FCS-MPC) based on hierarchical optimization for five-level H-bridge neutral-point-clamped (5L-HNPC) inverter-fed induction motor drives. Fault-tolerant operation is analyzed, and the fault-tolerant control algorithm is improved. Adopting FCS-MPC based on hierarchical optimization, where the voltage is used as the controlled objective, called model predictive voltage control (MPVC), the postfault controller is simplified as a two layer control. The first layer is the voltage jump limit, and the second layer is the voltage following control, which adopts the optimal control strategy to ensure the current following performance and uniqueness of the optimal solution. Finally, simulation and experimental results verify that 5L-HNPC inverter-fed induction motor drives have strong fault tolerant capability and that the FCS-MPVC based on hierarchical optimization is feasible.

A Control Strategy Based on Small Signal Model for Three-Phase to Single-Phase Matrix Converters

  • Chen, Si;Ge, Hongjuan;Zhang, Wenbin;Lu, Song
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1456-1467
    • /
    • 2015
  • This paper presents a novel close-loop control scheme based on small signal modeling and weighted composite voltage feedback for a three-phase input and single-phase output Matrix Converter (3-1MC). A small non-polar capacitor is employed as the decoupling unit. The composite voltage weighted by the load voltage and the decoupling unit voltage is used as the feedback value for the voltage controller. Together with the current loop, the dual-loop control is implemented in the 3-1MC. In this paper, the weighted composite voltage expression is derived based on the sinusoidal pulse-width modulation (SPWM) strategy. The switch functions of the 3-1MC are deduced, and the average signal model and small signal model are built. Furthermore, the stability and dynamic performance of the 3-1MC are studied, and simulation and experiment studies are executed. The results show that the control method is effective and feasible. They also show that the design is reasonable and that the operating performance of the 3-1MC is good.

An Optimized PWM Switching Strategy for an Induction Motor Voltage Control (전압제어 유도 전동기를 위한 최적 PWM 스위칭 방법)

  • Han, Sang-Soo;Chu, Soon-Nam
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.5
    • /
    • pp.922-930
    • /
    • 2009
  • An optimized PWM switching strategy for an induction motor voltage control is developed and demonstrated. Space vector modulation in voltage source inverter offers improved DC-bus utilization and reduced commutation losses and has been therefor recognized the preferred PWM method especially in case of digital implementation. An optimized PWM switching strategy for an induction motor voltage control consists of switching between the two active and one zero voltage vector by using the proposed optimal PWM algorithm. The preferred switching sequence is defined as a function of the modulation index and period of a carrier wave. The sequence is selected by using the inverter switching losses and the current ripple as the criteria. For low and medium power application, the experimental results indicate that good dynamic response and reduced harmonic distortion can be achieved by increasing switching frequency.

Design and Implementation of 1.8kW bi-directional LDC with Parallel Control Strategy for Mild Hybrid Electric Vehicles (병렬제어기법이 적용된 1.8kW급 마일드 하이브리드 양방향 LDC 설계 및 구현)

  • Kim, Hyun-Bin;Jeong, Jea-Woong;Bae, Sungwoo;Kim, Jong-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.1
    • /
    • pp.75-81
    • /
    • 2017
  • This paper presents a design and parallel control strategy of 1.8 kW low-voltage DC-DC converter (LDC) for mild hybrid electric vehicles to improve their power density, system efficiency, and operation stability. Topology and control scheme are important on the LDC for mild hybrid electric vehicles to achieve high system efficiency and power density because of their very low voltage and large current in input and output terminals. Therefore, the optimal topological structure and control algorithm are examined, and a detailed design methodology for the power and control stages is presented. A working sample of 1.8 kW LDC is designed and implemented by applying the adopted topology and control strategy. Experimental results indicate 92.45% of the maximum efficiency and 560 W/l of power density.

Novel DC Grid Connection Topology and Control Strategy for DFIG-based Wind Power Generation System

  • Yi, Xilu;Nian, Heng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.466-472
    • /
    • 2013
  • The paper presents a novel DC grid connection topology and control strategy for doubly-fed induction generator (DFIG) based wind power generation system. In order to achieve the wind power conversion, the stator side converter and the rotor side converter is used to implement the DFIG control based on the indirect air-gap flux orientation, and a DC/DC converter is used for the DFIG system to DC grid connection. The maximum power point tracking and DC voltage droop control can also be implemented for the proposed DFIG system. Finally, a 4-terminal DFIG-based multi-terminal DC grid system is developed by Matlab to validate the availability of the proposed system and control strategy.

Study for Reducing Ripples of the PV Array Output in Grid-Connected Photovoltaic Power System (계통연계헝 태양광인버터의 PV Array 출력리플 저감을 위한 연구)

  • Kim, Hee-Jung;Chung, Yong-Ho;Lee, Ki-Su;Jon, Young-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.202-205
    • /
    • 2006
  • In the PV power system, output of the PV array must contain inherent ripples due to the single-phase inverter. So the function of maximum power point tracking to increase the output efficiency of PV system is degraded. Therefore, to overcome this problem, this paper presents a control strategy for the reducing ripples of the PV array output in grid-connected photovoltaic power system. The proposed control system consists of two loops the maximum power point tracking loop using the perturbation and observation method is used to calculate the reference solar array terminal voltage(Vref) for reducing ripples of the PV array output and the PI control loop is used to regulate the solar array output voltage according to the Vref. The performance of proposing control strategy is analyzed by means of the PSCAD/EMTDC simulation. As a result, we may obtain the high performance of the proposed control strategy.

  • PDF

Direct Torque Control of Induction Motor by Torque Slope and Reference Voltage Control (토오크 기울기 및 기준전압제어에 의한 유도전동기의 직접토오크 제어)

  • Kim Pyoung-Ho;Choi Youn-Ok;Cho Geum-Bae;Baek Hyung-Lae;Lee Sang-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.9-15
    • /
    • 2006
  • The conventional hysterysis band DTC(Direct Torque Control) strategy have relatively high torque ripple at low speed and variable switching frequency according to motor speed even though it provides a fast torque response with very simple scheme consisted with only two hysteresis band comparators and a switching table for torque and flux control. In this paper, author proposed a new DTC scheme based on the torque slope and reference voltage control. The new scheme can maintain the minimized torque ripple and constant switching frequency. Experimental tests carried out with an 1.5kW induction motor drive system show improved dynamic characteristics and prove the feasibility of proposed strategy.

Fault-Tolerant Control of Cascaded H-Bridge Converters Using Double Zero-Sequence Voltage Injection and DC Voltage Optimization

  • Ji, Zhendong;Zhao, Jianfeng;Sun, Yichao;Yao, Xiaojun;Zhu, Zean
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.946-956
    • /
    • 2014
  • Cascaded H-Bridge (CHB) converters can be directly connected to medium-voltage grids without using transformers and they possess the advantages of large capacity and low harmonics. They are significant tools for providing grid connections in large-capacity renewable energy systems. However, the reliability of a grid-connected CHB converter can be seriously influenced by the number of power switching devices that exist in the structure. This paper proposes a fault-tolerant control strategy based on double zero-sequence voltage injection and DC voltage optimization to improve the reliability of star-connected CHB converters after one or more power units have been bypassed. By injecting double zero-sequence voltages into each phase cluster, the DC voltages of the healthy units can be rapidly balanced after the faulty units are bypassed. In addition, optimizing the DC voltage increases the number of faulty units that can be tolerated and improves the reliability of the converter. Simulations and experimental results are shown for a seven-level three-phase CHB converter to validate the efficiency and feasibility of this strategy.

Model Predictive Control of Three-Phase Inverter for Uninterruptible Power Supply Applications under a Hexagonal Input Constraint Region (육각형 입력제약 공간을 이용한 무정전 전원장치의 모델예측제어)

  • Kim, Seok-Kyoon;Kim, Jung-Su;Lee, Young Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Using the classical cascade voltage control strategy, this paper proposes an analytical solution to an MPC (Model Predictive Control) problem with a hexagonal input constraint set for the inner-loop to regulate the output voltage of the UPS (Uninterruptible Power Supply). Focus is placed on how to deal with the hexagonal input constraint set without any approximation. Following the conventional cascade voltage control strategy, the PI (Proportional-Integral) controller is used in the outer-loop in order to regulate the output voltage. The simulation results illustrate that the capacitor voltage rapidly goes to its reference in a satisfactory manner while keeping other state variables bounded under an unexpected load changes.