Silyl-group functionalized organic additive for high voltage Ni-rich cathode material

  • Jang, Seol Heui;Jung, Kwangeun;Yim, Taeeun
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1345-1351
    • /
    • 2018
  • To allow stable cycling of layered nickel-rich cathode material at high voltage, silyl-functionalized dimethoxydimethylsilane is proposed as a multi-functional additive. In contrast to typical functional additive, dimethoxydimethylsilane does not make artificial cathode-electrolyte interfaces by electrochemical oxidation because it is quite stable under anodic polarization. We find that dimethoxydimethylsilane mainly focuses on scavenging nucleophilic fluoride species that can be produced by electrolyte decomposition during cycling, leading to improving interfacial stability of both nickel-rich cathode and graphite anode. As a result, the cell cycled with dimethoxydimethylsilane-controlled electrolyte exhibits 65.7% of retention after 100 cycle, which is identified by systematic spectroscopic analyses for the cycled cell.

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography

  • Kim, Sang Youn;Cho, Jeong Yeon;Lee, Joongyub;Hwang, Sung Il;Moon, Min Hoan;Lee, Eun Ju;Hong, Seong Sook;Kim, Chan Kyo;Kim, Kyeong Ah;Park, Sung Bin;Sung, Deuk Jae;Kim, Yongsoo;Kim, You Me;Jung, Sung Il;Rha, Sung Eun;Kim, Dong Won;Lee, Hyun;Shim, Youngsup;Hwang, Inpyeong;Woo, Sungmin;Choi, Hyuck Jae
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1119-1129
    • /
    • 2018
  • Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose ($5.73{\pm}4.04$ vs. $8.43{\pm}4.38mSv$) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ${\geq}3$), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.

A New Driving Waveform for Stable Address Discharge in an Alternating Current Plasma Display Panel

  • Kim, Sung-Hwan;Seo, Jeong-Hyun;Lee, Seok-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.503-506
    • /
    • 2004
  • In this paper, we suggest a new driving waveform for stable address discharge in AC PDP without the reduction of contrast ratio. To analyze the influence of cross-talk between discharge and non-discharge cells and verify that proposed waveform shows a stable address discharge, we measured the address discharge delay time. The proposed waveform shows the reduction of the cross-talk and concurrently the improvement of address voltage margin compared with those of selective reset waveform having one reset period in 1TV-Field..

  • PDF

A Novel Fast-Switching LCD with Dual-Domain Bend Mode

  • Satake, Tetsuya;Kurata, Tetsuyuki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.209-212
    • /
    • 2004
  • A navel fast-switching LCD with dual-domain bend (DDB) mode is described DDB alignment is achieved using antiparallel-rubbed cell filled with chiral-doped LC. Initial alignment is mono-domain 180-degree twist. Tilt direction is controlled by oblique electric field to be counter direction in each domain Twist-to-DDB deformation occurs continuously so that DDB mode does not require high-voltage initialization which is inevitable in Optically Compensated Bend (OCB) mode. DDB gives wide and symmetric viewing angle in contrast to mono-domain bend formed from 180-degree twist showing strong asymmetry.

  • PDF

Ferroelectric Cholesteric Suspension

  • Buchnev, Olesander;Reznikov, Yuri;Tereshchenko, Olexander;Grabar, A.;Kwon, Soon-Bum
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1236-1239
    • /
    • 2004
  • We developed a new cholesteric material for bistable LCDs. The material consists of dispersion of sub-micron ferroelectric particles in cholesteric host. We found that the doping of the cholesteric with ferroelectric particles in small concentration (< 1% by weight) strongly improved basic characteristics of the transition between poly-domain planar texture and focal conic texture. Decrease of the driving voltage, increase of the reflection contrast and the steepness of the transition is associated with giant steady dipole and dielectric constant of the ferroelectric particles.

  • PDF

Characteristic of a Negative Driving Waveform in ac PDPs

  • Kang, Jung-Won
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.97-100
    • /
    • 2009
  • A negative waveform was studied to improve the driving characteristics of reset and address periods in ac PDP. Comparative experiments between negative and conventional positive waveforms were performed with 42-inch XGA PDP module. The negative waveform showed lower breakdown voltage than the conventional positive waveform in reset period. Due to its weak and stable discharge during reset period, the contrast ratio was improved by decreasing the black luminance. During address period, the discharge time-lag was measured. The formative time lag ($=T_f$) of negative waveform was improved about 22.8% than $T_f$ of conventional positive waveform.

  • PDF

OBSERVATION OF THE MAGNETIC DOMAIN IN THIN-FILM HEADS BY ELECTRON MICROSCOPY

  • Kobayashi, Kazuo
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.710-715
    • /
    • 1995
  • Magnetic domains were observed using an image lock-in technique for backscattered electron contrast (Type II) with a 200 kV scanning electron microscope. Backscattered electrons indicate a difference in magnetic domain structures at the upper and lower parts of the upper pole in thin-film heads, changing the acceleration voltage. With this method, it is also possible to observe the domain structure of the thin-film head pole through a 10 to $20\;\mu\textrm{m}$ protective layer, and the upper shield of the MR head through the coil in the resist, alumina overcoat, and upper pole.

  • PDF

The Experiment of Grid Characteristics for High-voltage Radiography of Chest (흉부촬영시 관전압과 선질에 따른 적절한 격자의 선택을 위한 실험)

  • Kim, Jung-Min;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 1992
  • Grids can improve the diagnostic quality of chest radiography by trapping the greater part of scattered radiation thus providing more detailed. chest radiographic images. It is most effective mathod of reduce the scatter ratio but must increase the expour factor. The benefit of use of grid is improve the contrast and the loss is increase of patient dose. In chest radiography especially hard quality high voltage radiography it will have to be considered to select the optimum grid with view point of benefit and loss. In this experiment, author got some result of characteristics about 4 different grids with film method. 1. There was no difference the scatter ratio in case of no grid and the scatter ratio was about 60%. 2. 16 : 1 grid was excellent of scatter reduction factor in high voltage chest radiography, next was 10 : 1, CROSS, MICRO FINE grid have low scatter reduction rate compare to 16:1, 10:1 grid. 3. The bucky factor of CROSS grid in accordance of kVp was find out the highest in 4 grids, on the contraly 10 : 1 grid was profitable to the exposure does. 4. With careful consideration in the point of scatter reducion rate and bucky factor, author suggest the 10 : 1 linear grid on the use of chest radiography in $80{\sim}120\;kVp$, 16 : 1 grid in $120{\sim}140\;kVp$.

  • PDF

Influence of Processing Conditions on PVDF Properties

  • Lebedev, S.M.;Gefle, O.S.;Semenikhin, M.V.
    • Journal of Powder Materials
    • /
    • v.18 no.2
    • /
    • pp.176-180
    • /
    • 2011
  • Study of the main properties of PVDF films produced by two processing technologies such as hot pressing from a melt or solution casting was the aim of this paper. All samples were prepared of as-received PVDF powder. First group of samples was prepared by the hot pressing. Second group of samples was prepared by the solution casting method. PVDF powder was dissolved in dimethylformamide. To characterize properties of samples, different experimental methods such as FRA (dielectric spectroscopy), IR-spectroscopy and DSC/TGA analysis were used in this work. It was found that IR-spectra of both studied groups do not change compared to that for virgin PVDF powder. It confirms that molecular structure is practically independent on the processing technology of samples. The only difference has been found that new band centered at $1723\;cm^{-1}$ appears for samples prepared by the hot pressing method. This absorption band is related with formation of C=C bonds in samples prepared by the hot pressing method in contrast both to PVDF powder and samples prepared by the solution casting method.