• Title/Summary/Keyword: Voltage Rising

Search Result 237, Processing Time 0.022 seconds

Electrical Breakdown Properties of Insulating Oils for oil-immersed transformer (유입변압기용 절연유의 절연파괴특성)

  • Lee, I.S.;Shin, H.T.;Lee, J.P.;Lee, S.W.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.605-608
    • /
    • 2001
  • With the intention of investigating the breakdown properties of oil-immersed transformer oils in temperature range of $20\sim100[^{\circ}C]$, we are made researches AC breakdown in the gap of $500\sim2500[{\mu}m]$. The classification for the physical properties of oil for oil-immersed transformer by FTIR and H-NMR experiments was confirmed to type of mineral oils. As the dependance of breakdown properties due to electrode gap length variation, breakdown voltage was found increasing according to the increase of gap, while dielectric strength was decreasing. As a result the characteristics for AC breakdown, It goes to prove that the breakdown voltage was increased to $90[^{\circ}C]$ but decreased over $90[^{\circ}C]$ in the temperature range. Also, breakdown voltage was found increasing in the increase of gap and the rising of temperature according to Weibull distribution.

  • PDF

Development of the Spark-gap Switch with Dual Trigger System (쌍방향 시동방식의 고속투입스위치 개발)

  • Kim, Maeng-Hyeon;Seo, Yun-Taek;Park, Seung-Jae;Park, Byeong-Rak;Go, Ui-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.359-364
    • /
    • 2000
  • This paper is introducing a newly developed spark-gap switch with dual trigger system, into which the current from the voltage source is injected along with the test sequence during the synthetic testing of high voltage circuit-breaker. The currently-used spark gap switch is narrow in operating range due to the use of the method of triggering energy being injected by single way. As a result, the frequent happening of misoperation has greatly reduced the test quality and test efficiency and has required the cost of maintenance excessively. In this study, accordingly, in order to basically remove these problems, another triggering system is installed to the opposite direction on the existing triggering system; attaching the same time and the same rising time of pulse wave as on the existing system, so that at a comparatively trigger gap distance from the main electrode(the gap can be operated at 60% of self-break voltage, while at 80% in the current system), the main electrode has been enabled to be closed by the development of spark gap switch with dual trigger system.

  • PDF

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF

Study on the AC Interfacial Breakdown Properties in the Interface between toughened Epoxy and Silicone Rubber (Toughened 에폭시와 실리콘고무 계면의 교류 절연파괴 현상에 관한 연구)

  • 박우현;이기식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1079-1084
    • /
    • 2002
  • Because complex insulation method is used in EHV(extra high voltage) insulation systems, macro Interfaces between two different bulk materials which affect the stability of insulation system exist inevitably. Interface between toughened epoxy and silicone rubber was selected as a interface in EHV insulation systems and tested AC interfacial breakdown properties with variation of many conditions to influence on electrical Properties, such as interfacial pressure, roughness and oil. Specimen was designed to reduce the effect of charge transport from electrode in the process of breakdown and to have the tangential electrical potential with the direction of the interface between epoxy and silicone rubber by using FEM(finite elements method). It could control the interfacial pressure, roughness and viscosity of oil. From the result of this study, it was shown that the interfacial breakdown voltage is improved by increasing interfacial Pressure and oil. In particular, the dielectric strength saturates at certain interracial Pressure level. The decreasing ratio of the interfacial breakdown voltage in non-oiled specimen was increased by the temperature rising, while oiled specimen was not affected by temperature.

Analysis of Wall-charge behavior using V-Q Lissajous' figure in AC-PDP driving (AC-PDP 구동에 있어서 V-Q Lissajous' Figure을 이용한 벽전하 거동분석)

  • Chung, Jong-Kab;Cho, Woo-Sung;Choi, Chang-Hun;Ju, Byeong-Keon;Park, Sun-Woo;Kim, Chul-Ju;Rho, Seung-Ryong;Kim, Young-Cho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.111-115
    • /
    • 2002
  • To understand the discharge characteristics in AC-PDP, it is necessary to study on the wall charge behavior. But, it is difficult to measure the wall charge directly. In this paper, the V-Q Lissajous' figure is used to measure the wall charge indirectly and analyze the wall charge behavior. With the V-Q Lissajous' figure, the discharge characteristics of AC-PDP are studied according to vary driving conditions, such as the frequency, pulse duty ratio, and rising & falling time. As a result, the V-Q Lissajous' figure is used to measure the discharge characteristics of the AC-PDP. It is confirmed that firing initial voltage and firing final voltage for discharge are effected by the aboved variables. Related with the wall voltage generation, it is thought that the difference of the slope at the V-Q Lissajous' figure is caused by charged ions inside the dielectric layer.

  • PDF

An Experimental Study on the Effect of Electrohydrodynamic Monodisperse Atomization According to Nozzle Characteristics (노즐 특성에 따른 전기수력학적 단분산 미립화 효과에 관한 실험적 연구)

  • Sung, K.A.;Lee, C.S.
    • Journal of ILASS-Korea
    • /
    • v.10 no.2
    • /
    • pp.18-31
    • /
    • 2005
  • This study was performed to explore the liquid breakup and atomization characteristics for the classification of drop formation mode and background of uniform droplets generation in electrohydrodynmaic atomization according to the change of experimental parameters such as nozzle material (stainless steel. teflon). fluid flow rate, applied electrical field and intensity, and frequency. In results, from the classification map of drop formation modes according to the variation of applied AC voltage and frequency at a stainless nozzle, the droplet size was smaller than the outer diameter of the nozzle tip relatively in the spindle mode. The transition points became clearly to be moved toward the high applied voltage by rising the applied AC frequency beyond 450Hz. Also the droplet radius can be observed quite small in the frequency bandwidth of $350{\sim}450Hz$. The droplet radiuses decrease as the applied voltage increases for a fixed applied AC frequency within the range from 50Hz to 400Hz Over 400Hz, the relation between the power intensity and the droplet size was not consistent with a continuous mechanism of liquid breakup. Thus, it is showed that the droplet size distribution using the teflon nozzle was analogous to the results of stainless steel, but the droplet size was bigger than that of stainless steel relatively in case of a teflon nozzle.

  • PDF

The Study on the Mutual Characteristics Between Transmitting Efficiency of Pulse Energy and Wall Plug Consumed Power of Non-Thermal Plasma (저온 플라즈마의 펄스에너지 전송효율과 Wall Plug 소비전력과의 상호 특성에 관한 연구)

  • Jeong, Jong-Han;Jeong, Hyeon-Ju;Kim, Hwi-Yeong;Jeong, Yong-Ho;Song, Geum-Yeong;Kim, Geun-Yong;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.506-510
    • /
    • 2002
  • In this paper, we study on the mutual characteristics between transmitting efficiency of pulse energy and wall plug consumed power of non-thermal Plasma for removing environmental pollutive gas of coal plant. To obtain high pulse energy of our system, we used MPC(magnetic pulse compressor) of power switch and tested their characteristics by adjusting electrode length of reactor and charging voltage in capacitor. As a result, we obtained consumed power of wall plug and a compressed pulse of voltage 110kV, rising time 500ns. Impedance of load on increasing electrode length was decreased, but electrical efficiency was increased. These results indicate we can control critical voltage of pulse corona and electrical efficiency of economic cost in power plant.

Sensorless Control of IPMSM with a Simplified High-Frequency Square Wave Injection Method

  • Alaei, Ahmadreza;Lee, Dong-Hee;Ahn, Jin-Woo;Saghaeian Nejad, Sayed Morteza
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1515-1527
    • /
    • 2018
  • This paper presents a sensorless speed control of IPMSM (Interior Permanent Magnet Synchronous Motor) using the high-frequency (HF) square wave injection method. In the proposed HF pulsating square wave injection method, injection voltage is applied into the estimated d-axis of rotor and high-frequency induced q-axis current is considered to estimate the rotor position. Conventional square wave injection methods may need complex demodulation process to find rotor position, while in the proposed method, an easy demodulation process based on the rising-falling edge of the injected voltage and carrier induced q-axis current is implemented, which needs less processing time and improves control bandwidth. Unlike some saliency-based sensorless methods, the proposed method uses maximum torque per ampere (MTPA) strategy, instead of zero d-axis command current strategy, to improve control performance. Furthermore, this paper directly uses resultant d-axis current to detect the magnet polarity and eliminates the need to add an extra pulse injection for magnet polarity detection. As experimental results show, the proposed method can quickly find initial rotor position and MTPA strategy helps to improve the control performance. The effectiveness of the proposed method and all theoretical concepts are verified by mathematical equations, simulation, and experimental tests.

Characteristics of Piezoelectric Transformer Using PMS-PZT, PMN-PZT Ceramics (PMS-PZT, PMN-PZT계 세라믹스를 이용한 압전변압기의 특성)

  • 이동균;안형근;한득영;윤석진;김현재
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.220-226
    • /
    • 2000
  • The piezoelectric material for piezoelectric transformer needs the high electromechanical coupling factor( $k_{p}$) the piezoelectric constant( $d_{33}$) and the mechanical quality factor( $Q_{m}$)in order to obtain high voltage step-up ratio and low temperature rising. In this study the piezoelectric transformers were fabricated using Pb[$Zr_{0.45}$/ $Ti_{0}$48//L $u_{0.02}$(M $n_{1}$3//S $b_{2}$3/)$_{0.05}$$O_3$(PMS-PZT) and Pb[Z $r_{0.25}$/ $Ti_{0.375}$(M $g_{1}$3//N $b_{2}$3/)$_{0.375}$$O_3$+0.5wt%Mn $O_2$(PMN-PZT) ceramics. The piezoelectric properties of PMS-PZT and PMN-PZT were measured. The voltage set-up ratios of the piezoelectric transformers using PMS-PZT and PMN-PZT were the value of 15, 20 respectively under 100$_{KΩ}$ in Rosen type transformer.r.ormer.r.r.r.r.r.r.

  • PDF

Partial Discharge Characteristics due to shift of Void Position in XLPE (XLPE에서 보이드 위치변화에 따른 부분방전특성)

  • Kim, Tag-Yong;Yang, Jae-Hoon;Kim, Weon-Jong;Shin, Hyun-Taek;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.86-89
    • /
    • 2004
  • To estimate a electrical performance of the extra high voltage XLPE cable the discharge properties due to shift of void position were investigated. The ${\phi}-q-n$ properties have been measured at room temperature by rising voltage ratio of 0.5[kV]. An obtained data was stored to personal computer through A/D converter. The period of applied wave form and discharge values were divided into 64 parts and discharge values generated during 10 seconds were accumulated by phases. As a result, it was confirmed that the charge, phase angle and counts of discharge changed due to void position.

  • PDF