• Title/Summary/Keyword: Voltage Fed Inverter

Search Result 265, Processing Time 0.021 seconds

Enhanced Voltage Gain Single-Phase Current-Fed qZ-Source Inverter (전압 이득이 향상된 단상 전류형 qZ-소스 인버터)

  • Shin, Hyun-Hak;Cha, Hon-Nyong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.305-311
    • /
    • 2013
  • This paper proposes a performance improvement of existing single-phase current-fed qZ-Source inverter. Voltage gain of the traditional voltage-fed full-bridge inverter and single-phase current-fed qZ-source inverter is only equal to or smaller than input voltage. The proposed inverter can obtain twice higher voltage gain than the single-phase current-fed qZ-Source inverter by adding an extra switch and a capacitor in the circuit. In addition, the proposed inverter shares the common ground between dc input and ac output voltage. Therefore, the proposed inverter can eliminate the possible ground leakage current problem when it is used for grid-tied photovoltaic inverter system. A 120 W prototype inverter is built and tested to verify performances of the proposed inverter.

Instantaneous sinusoidal currant tracking mode inverter with quasi-resonant Link in DC side (공진 DC Link 순시 정현파 전류 추종형 인버터를 이용한 유도전동기 제어시스템)

  • Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.324-327
    • /
    • 1990
  • In this paper describes the feasibility study on a single-phase / three-phase voltage-fed inverter using 1GBTs, incorporating voltage-mode quasi-resonant DC Link and the instantaneous Sinusoidal Current tracking adaptive control implementation under zero voltage switching resfriction. The simulation and experimental results are shown here and discussed for single-phase voltage-fed and three-phase voltage-fed inverter in order to verify the new operating principle of the Inverter topology proposed here.

  • PDF

A Study on Synchronized AC Source Voltage Regulator of Voltage Fed Inverter using a Photovoltatic Effect

  • Hwang, Lak-Hoon;Lee, Chun-Sang;Kim, Jong-Lae;Jang, Byong-Gon
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.547-553
    • /
    • 1998
  • In this paper, we composed of utility interactive pv generation system of voltage source inverter, and represented uninterrutible power supply (UPS) equipment maintaining constant voltage, using a pulse width modulation(PWM) voltage fed inverter, as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to dc side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

  • PDF

Analysis on the Switching Surge Characteristics of a High-Voltage Induction Motor Fed by PWM Inverter Using EMTP

  • Kim Jae-Chul;Song Seung-Yeop;Lee Do-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.22-30
    • /
    • 2005
  • The PWM inverter drive may cause an over voltage at the motor terminal, which imposes severe electric stresses on the inter-turn insulation of motor windings. Unlike low-voltage induction motors, high-voltage induction motors have a stator type of form-wound coil for insulation and are insulated to the slot and the coil. So, this paper presents a PWM 3-level inverter, H-Bridge cascaded 7-level inverter and High-voltage induction motor model. It then analyzes the voltage that generates at the input terminal of the high-voltage induction motor fed by each inverter. Also, in order to examine a factor that influences the switching surge voltage, this paper proposes the system equivalent model and performs the case studies using EMTP.

Elimination of Harmonics Voltage-fed Inverter using Flyback Converter with Three-Phase High Power Factor (3상 고역률 Flyback 컨버터를 이용한 전압형 인버터의 고조파 제거)

  • Suh, K.Y.;Kwon, S.K.;Lee, H.W.;Ko, T.E.;Kim, Y.M.;Mun, S.P.;Jang, W.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2695-2697
    • /
    • 1999
  • A new three-phase voltage-fed inverter using partial resonant converter with high power factor and high efficiency is proposed. The proposed Flyback converter is constructed by using a resonant network in parallel with the switch of the conventional converter. The devices are switched zero voltage or zero current eliminating the switching loss. This paper introduces elimination of harmonics compared with conventional SPWM inverter and three-phase voltage-fed inverter using Flyback converter.

  • PDF

A Ringing Surge Clamper Type Active Auxiliary Edge-Resonant DC Link Snubber-Assisted Three-Phase Soft-Switching Inverter using IGBT-IPM for AC Servo Driver

  • Yoshitsugu, Junji;Yoshida, Masanobu;Hiraki, Eiji;Inoue, Kenji;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.115-124
    • /
    • 2002
  • This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.

Analysis of Inverter-Fed Induction Motor Using F.E.M and Harmonic Equivalent Circuit (슬롯피치 경계 조건을 이용한 인버터 구동 유도 전동기의 회전자 등가회로 정수 추출 및 특성해석)

  • Lee, Geon-Ho;Kim, Byeong-Tae;Gwon, Byeong-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.7
    • /
    • pp.331-338
    • /
    • 2002
  • An inverter-fed induction is driven by a harmonic voltage source so that it is necessary to be analysed by time-stepping F.E.M. But it takes so long time that disadvantageous to design. This paper presents a simple analysis method for inverter-fed induction motor using FEM and harmonic equivalent circuit. First, the rotor bar resistance and the leakage reactance are determinated by FEA for 1 slot region in rotor to consider the skin effect and the saturation. Secondly, the characteristic of the motor is analyzed by the harmonic equivalent circuits consisting of the obtained parameters from the FEA. This method is carried out to analyze an induction motor driven by the sinusoidal voltage and the inverter. The results are verified by comparing with those of the time-step F.E.A and the experiment.

The Experimental Consideration about Loss of Three-phase Voltage-fed Inverter using Auxiliary Resonant DC Link (ARDCL을 이용한 3상 전압형 인버터의 손실에 관한 실험적 고찰)

  • 서기영;문상필;김주용;이상현;박영조
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.100-105
    • /
    • 2003
  • This paper proposes a new auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually-measured conduction loss characteristic of switching device module. Voltage-fed soft switching three-phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three-phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

Compact Wireless IPT System Using a Modified Voltage-fed Multi-resonant Class EF2 Inverter

  • Uddin, Mohammad Kamar;Mekhilef, Saad;Ramasamy, Gobbi
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.277-288
    • /
    • 2018
  • Wireless inductive power transfer (IPT) technology is used in many applications today. A compact and high-frequency primary side inverter is one of the most important parts of a WPT system. In this study, a modified class EF-type voltage-fed multi-resonant inverter has been proposed for WPT application at a frequency range of 85-100 kHz. Instead of an infinite input choke inductor, a resonant inductor is used to reduce loss and power density. The peak voltage stress across the MOSFET has been reduced to almost 60% from a class-E inverter using a passive clamping circuit. A simple yet effective design procedure has been presented to calculate the various component values of the proposed inverter. The overall system is simulated using MATLAB/SimPowerSystem to verify the theoretical concepts. A 500-W prototype was built and tested to validate the simulated results. The inverter exhibited 90% efficiency at nearly perfect alignment condition, and efficiency reduced gradually with the misalignment of WPT coils. The proposed inverter maintains zero-voltage switching (ZVS) during considerable load changes and possesses all the inherent advantages of class E-type inverters.

Current Mode Integrated Control Technique for Z-Source Inverter Fed Induction Motor Drives

  • Thangaprakash, Sengodan;Krishnan, Ammasai
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.285-292
    • /
    • 2010
  • This paper presents a current mode integrated control technique (CM-ICT) using a modified voltage space vector modulation (MSVM) for Z-source inverter (ZSI) fed induction motor drives. MSVM provides a better DC voltage boost in the dc-link, a wide range of AC output voltage controllability and a better line harmonic profile. In a voltage mode ICT (VM-ICT), the outer voltage feedback loop alone is designed and it enforces the desired line voltage to the motor drive. An integrated control technique (ICT), with an inner current feedback loop is proposed in this paper for the purpose of line current limiting and soft operation of the drive. The current command generated by the PI controller and limiter in the outer voltage feedback loop, is compared with the actual line current, and the error is processed through the PI controller and a limiter. This limiter ensures that, the voltage control signal to the Z-source inverter is constrained to a safe level. The rise and fall of the control signal voltage are made to be gradual, so as to protect the induction motor drive and the Z-source inverter from transients. The single stage controller arrangement of the proposed CM-ICT offers easier compensation. Analysis, Matlab/Simulink simulations, and experimental results have been presented to validate the proposed technique.