• 제목/요약/키워드: Voltage Collapse Criteria

검색결과 5건 처리시간 0.022초

벡터 곱에 근거한 에너지함수 유도와 선로 컨덕턴스 및 커패시터를 포함한 전력시스템에의 적용 연구 (Derivation of an Energy Function Based on Vector Product and Application to the Power System with Transfer Conductances and Capacitors)

  • 문영현;오용택;이병하
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권6호
    • /
    • pp.274-283
    • /
    • 2005
  • This paper presents a new method to derive energy function based on vector product. Using this method, an energy function to consider transfer conductances and capacitors is derived. Then we recommend a voltage collapse criteria to predict the voltage collapse in power systems by using the energy margin derived by the proposed energy function. This energy function is applied to a 2-bus power system reflecting transfer conductances and capacitors. We show that the energy function derived based on vector product can be applied in order to analyze power system stability and the energy margin can be utilized as a criterion of voltage collapse by simulation for the 2-bus system.

변압기 탭이 반영된 에너지 함수를 이용한 전압안정도 해석 (Voltage Stability Analysis Based on Energy Function Considering Tap of Transformer)

  • 이기제;최병곤;권용준;문영현;오용택;이병하
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권7호
    • /
    • pp.337-344
    • /
    • 2005
  • An energy function is derived on the basis of the EMM(Equivalent Mechanical Model) to take account of the effects of tap changer, and then the VC(Voltage Collapse) criteria is proposed to predict the voltage collapse in Power systems. The VC criterion can be evaluated by using the energy margin given by the energy gap between UEP(Unstable Equilibrium Point) and SEP(Stable Equilibrium Point) of the energy function adopted, in which it is noted that the energy contour should be considered due to energy discontinuity associated with tap changing. This paper shows that the proposed VC criterion improves the accuracy of voltage stability analysis with application to a two-bus sample system.

Control Strategy against Undesirable Zone 3 Relay Operation in Voltage Instability

  • Lee Byong-Jun;Song Hwa-Chang
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.144-151
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions during relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. Furthermore, it comes up with the control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information that is valuable in the determination of control strategy. As a case study, an example applying the framework is shown with the modified New England 39-bus system.

전압붕괴 측면에서의 Zone3 보호동작 억제를 위한 제어방안 (Control strategy against undesirable zone 3 protection with respect to voltage collapse)

  • 송화창;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.24-26
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions of relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. The proposed approach comes up with control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information which is valuable for both the timing and amount of control. The methodology is demonstrated through the modified New England 39-bus system.

  • PDF

국내 전력계통 신뢰도 기준을 위한 전압 제한범위 결정에 관한 연구 (A Study on the Determination of Voltage Limits for Korean Power System Reliability)

  • 벤지마플로레스;드위리아나아리아니;김승진;송화창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.335-336
    • /
    • 2015
  • Voltage collapse is one of the main threats in power system operation and it is a result of a very low voltage profile in one or multiple areas in the power system network. Hence, the need for proper coordination among transmission and generator operators to maintain voltage stability if of paramount importance. In this paper, the different voltage and reactive power operating guidelines and criteria of various electric reliability councils, coordinating councils, transmission system operators and other electric utilities are discussed. Among these are NERC, ENTSO-E, WECC, PJM and ERCOT. A comprehensive comparison is also made to the existing Korean power system voltage reliability guidelines. Furthermore, this paper presents a set of voltage and reactive power guidelines that can help in determining voltage limits that can improve the reliability of the Korean power system operation.

  • PDF