• Title/Summary/Keyword: Volatile Organic Compounds (VOC)

Search Result 382, Processing Time 0.025 seconds

Comparison of VOCs Concentration Characteristic According to Measurement Methods in Exhibition Hall (휘발성유기화합물(VOCs)의 측정방법에 따른 유물 전시관 내 농도 분포 특성 비교)

  • Lim, BoA;Lee, Sun Myung
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.25-44
    • /
    • 2014
  • In this study, measured annual year and seasonal concentrations of VOCs by Active type and Passive type using the measurement and analysis method in the exhibition hall and outdoor. It was compared with the correlation between the methods according the comparison of methods to measured concentrations. As a results, the annual average concentrations of TVOC in exhibition room($906.5{\mu}g/m^3$) was greater than for most of the study period, more than 1.8 times the standard in the Ministry of Environment. ${\Sigma}VOCs$ concentration of exhibition room by Active type was higher than Passive type. Some VOCs was decreased with the lapse of time a temporary increase tendencies was. The annual average I/O ratio of TVOC was 9.0, ${\Sigma}VOCs$ was confirmed to occur in a large amount inside the exhibition hall ${\Sigma}VOCs$ was studied to 34.0. Correlation coefficient of ${\Sigma}VOCs$ was 0.367. Toluene was 0.567 that the survey was the largest analysis to the relationship between the two methods.

  • PDF

A Study on The Groundwater Contamination Focused on VOCs in Chung-Nam Area (충청남도 지역의 VOCs를 중심으로 한 지하수오염 실태)

  • 이창균;장순웅;유지택;임봉수
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.8-13
    • /
    • 1999
  • This research was investigated to examine the status of goundwater contamination in Chung-Nam area over 2 years from 1996 May to 1998 May. The results show that the overall detection rates of VOCs (volatile organic compounds) by region were as followed: industrial region > agricultural & industrial complex region > gas station region > around industrial region > downtown region, and excess rates of those were as followed: industrial region > gas station region > agricultural & industrial region > around industrial region > downtown region. Benzene and TCE of VOCs examined in Chon-An industrial region exceeded drinking water standard. At the agricultural & industrial complex region, the observed mean concentration of TCE was 3.107 mg/L and TCE was also detected at 48.152 mg/L which is 100 times higher than drinking water standard, and other VOCs were also observed at higher concentrations as well. Based on our studies, It is concluded that appropriate remedial action should be performed to protect further groundwater contamination and to restore groundwater quality in Chung-Nam area.

  • PDF

Numerical Analysis on Biogenic Emission Sources Contributing to Urban Ozone Concentration in Osaka, Japan

  • Nishimura, Hiroshi;Shimadera, Hikari;Kondo, Akira;Akiyama, Kazuyo;Inoue, Yoshio
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.259-271
    • /
    • 2015
  • This study conducted analyses on biogenic volatile organic compounds (BVOC) emission sources contributing to urban ozone ($O_3$) concentration in Osaka Prefecture, Japan in summer 2010 by using the Weather Research and Forecasting model (WRF) version 3.5.1 and the Community Multiscale Air Quality model (CMAQ) version 5.0.1. This prefecture is characterized by highly urbanized area with small forest area. The contributions of source regions surrounding Osaka were estimated by comparing the baseline case and zero-out cases for BVOC emissions from each source region. The zero-out emission runs showed that the BVOC emissions substantially contributed to urban $O_3$ concentration in Osaka (10.3 ppb: 15.9% of mean daily maximum 1-h $O_3$ concentration) with day-by-day variations of contributing source regions, which were qualitatively explained by backward trajectory analyses. Although $O_3$ concentrations were especially high on 23 July and 2 August 2010, the contribution of BVOC on 23 July (35.4 ppb: 25.6% of daily maximum $O_3$) was much larger than that on 2 August (20.9 ppb: 14.2% of daily maximum $O_3$). To investigate this difference, additional zero-out cases for anthropogenic VOC (AVOC) emissions from Osaka and for VOC emissions on the target days were performed. On 23 July, the urban $O_3$ concentration in Osaka was dominantly increased by the transport from the northwestern region outside Osaka with large contribution of $O_3$ that was produced through BVOC reactions by the day before and was retained over the nocturnal boundary layer. On 2 August, the concentration was dominantly increased by the local photochemical production inside Osaka under weak wind condition with the particularly large contribution of AVOC emitted from Osaka on the day.

Quantitative Assessment on Contributions of Foreign NOx and VOC Emission to Ozone Concentrations over Gwangyang Bay with CMAQ-HDDM Simulations (CMAQ-HDDM을 이용한 광양만 오존 농도의 국외 기여도 분석)

  • Bae, Changhan;Kim, Byeong-Uk;Kim, Hyun Cheol;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.708-726
    • /
    • 2018
  • In this study, we examined the contribution of nitrogen oxides and volatile organic compounds emitted from China and Japan to ozone concentrations over Gwangyang-bay, South Korea. We used a chemical transport model, Community Multi-scale Air Quality model, and its instrumented sensitivity tool, High-order Decoupled Direct Method. Intercontinental Chemical Transport Experiment-Phase B 2006 for East Asia and Clean Air Policy Support System 2007 emissions inventories for South Korea were used for the ozone simulation. During the study period, May 2007, the modeled maximum daily 8-hr average ozone concentration among seven air quality monitors in Gwangyang-bay was 68.8 ppb. The contribution of $NO_x$ emissions from China was 19.5 ppb (28%). The highest modeled ozone concentrations and Chinese contributions appeared when air parcels were originated from Shanghai area. The observed 8-hr average ozone concentrations in Gwangyang Bay exceeded the national ambient air quality standard (60 ppb) 203 times by daytime and 56 times by nighttime during the period. It was noticed that many exeedances happened when contribution of Chinese emissions to ozone concentrations over the area increased. Sensitivity analysis shows that a reduction in Chinese $NO_x$ and VOC emissions by 15% could lessen the total exceedance hours by 24%. This result indicates that high ozone concentrations over Gwangyang-bay are strongly enhanced by Chinese emissions.

A Effect of H2O-H2 Pretreatment on VOCs Oxidation over Noble Catalysts on Titania (티타니아에 담지된 귀금속촉매의 H2O-H2 전처리에 따른 휘발성유기화합물 산화에 미치는 영향)

  • Kim, Moon-Chan;Ko, Sun-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.18 no.6
    • /
    • pp.552-556
    • /
    • 2007
  • In this study, noble metals (Pd, Ru, Ir) were supported to $TiO_2$ catalyst. In order to distribute metals uniformly, $H_2O-H_2$ pretreatment technique was used. Xylene, toluene, and MEK were used as reactants. The monometallic or bimetallic catalysts were prepared by the excess wetness impregnation method and were characterized by XRD, and XPS analysis. Pd-Ru, Pd-Ir bimetallic catalysts had multipoint active sites which improved the range of Pd metal state. Bimetallic catalysts had a higher conversion of VOCs than that of monometallic one. The effect of $H_2O-H_2$ pretreatment technique was the enhancement of uniform distribution of Pd particles and promotion of catalytic efficiency. In this study, addition of Ru and Ir metals to Pd promoted oxidation conversion of VOCs. In addition, $H_2O-H_2$ pretreatment promoted removal efficiency of VOCs on the $TiO_2$ support.

Use of Gas-Sensor Array Technology in Lung Cancer Diagnosis

  • Kim, Young Jun;Yu, Han Young;Baek, In-Bok;Ahn, Chang-Geun;Lee, Bong Kuk;Kim, Yarkyeon;Yoon, Yong Sun;Lim, Ji Eun;Lee, Byeong-Jun;Jang, Won Ik;Park, Jeong Ho;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.249-255
    • /
    • 2013
  • Gas-sensor array technology, which has been much utilized in the field of food technology by the name of 'electronic nose' is drawing attention in diagnosing lung cancer based on the analysis of the exhaled human breath. Much understanding has been accomplished about the composition of the volatile organic compounds (VOCs) of the human exhaled breath, in spite of some variations depending on research groups due mainly to lack of the standardization of the sensing procedures. Since VOCs may be produced during the process of cellular metabolism, difference in the cellular metabolism between healthy cells and lung cancer cells are expected to be reflected on the composition variation of the exhaled VOCs. Several studies have attempted to apply the gas-sensor array technology to lung cancer analysis using many different types of sensors including metal oxide, carbon black-polymer composite, surface acoustic wave, and gold nanoparticles. In this mini-review VOC as biomarkers, sensor array technology and application of the array technology for the diagnosis of cancer disease have been described.

Design and Function Analysis of Dust Measurement Platform based on IoT protocol (사물인터넷 프로토콜 기반의 미세먼지 측정 플랫폼 설계와 기능해석)

  • Cho, Youngchan;Kim, Jeongho
    • Journal of Platform Technology
    • /
    • v.9 no.4
    • /
    • pp.79-89
    • /
    • 2021
  • In this paper, the fine dust (PM10) and ultrafine dust (PM2.5) measurement platforms are designed to be mobile and fixed using oneM2M, the international standard for IoT. The fine dust measurement platform is composed and designed with a fine dust measurement device, agent, oneM2M platform, oneM2M IPE, and monitoring system. The main difference between mobile and fixed is that the mobile uses the MQTT protocol for interconnection between devices and services without blind spots based on LTE connection, and the fixed uses the LoRaWAN protocol with low power and wide communication range. Not only fine dust, but also temperature, humidity, atmospheric pressure, volatile organic compounds (VOC), carbon monoxide (CO), sulfur dioxide (SO2), nitrogen dioxide (NO2), and noise data related to daily life were collected. The collected sensor values were managed using the common API provided by oneM2M through the agent and oneM2M IPE, and it was designed into four resource types: AE and container. Six functions of operability, flexibility, convenience, safety, reusability, and scalability were analyzed through the fine dust measurement platform design.

Development of a building materials database; Volatile organic compounds, formaldehyde emission rates and chemical compositions (건축자재의 오염물질 방출 데이터베이스 개발; 휘발성유기화합물, 폼알데하이드 방출강도 및 화학조성)

  • Yu, Young-Jae;Lee, Chul-Won;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.57-64
    • /
    • 2009
  • A material database has been developed for VOCs and formaldehyde emitted from building materials in this study. New classification system has been made by correlating the classification methods used in Korean Air Cleaning and Environmental Protection Agency. The developed databases include emission rates of TVOC, 5VOC and formaldehyde emitted from each building material. In addition, the databases can be used as an input variable to estimate indoor air quality (IAQ) using computer simulation since they also contain chemical component and general imformation. Box plot was used to do statistical analysis for emission rates of formaldehyde and TVOCs from different types of building materials. Also we confirmed the building materials worsening IAQ by categorizing the emission characteristic of different types of pollutants.

The Physical and Thermal Properties Analysis of the VOC Free Composites Comprised of Epoxy Resin, and Dicyandiamide (VOC Free Epoxy Resin/Dicyandiamide 경화물의 배합비 변화에 따른 물리적 특성 및 열적특성 분석)

  • Kim, Daeyeon;Kim, Soonchoen;Park, Young IL;Kim, Young Chul;Lim, Choong-Sun
    • Clean Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2015
  • Volatile organic compounds (VOC) free adhesives have been interested by many scientists and engineers due to environmental regulations and the safety of industrial workers. In this work, a series of composites composed with bisphenol A epoxy resin used as solvent, dicyandiamide, and promoter were prepared to investigate the most appropriate molar ratio for steel-steel adhesion. The cured test specimen of each composite were measured with universal testing machine (UTM) to figure out mechanical properties such as tensile strength, Young’s modulus, and elongation. Furthermore, the lap shear strength of the specimen was tested with UTM while impact resistance was measured with Izod impact tester. The composite whose molar ratio of epoxy resin to curing agent is 1 : 0.9 (sample 3), showed better tensile strength, coefficient of elastic modulus, elongation, and impact strength than other composites did. The highest tanδ from dynamic mechanical analysis (DMA) was observed from sample 2 (epoxy resin: dicy = 1 : 0.7) while sample 3 showed slightly lower tanδ than that of 2. The morphology of the fracture surface of the cured composites from SEM showed that the number of subtle lines on the surface caused by impact increase as the contents of amine curing agent accrete. Furthermore, the viscosity change of sample 5 (epoxy resin: dicy = 1 : 1.3) was observed to confirm its storage stability.

Evaluating the Applicability of Activated Carbon-added Fiberboard Filters Fabricated with Lignocellulosic Fiber for the Reduction Equipment of Particulate Matter (리그노셀룰로오스 섬유 기반 활성탄-첨가 섬유판 필터의 미세먼지 저감장치용 적용가능성 평가)

  • Yang, In;So, Jae min;Hwang, Jeong Woo;Choi, Joon weon;Lee, Young-kyu;Choi, Wonsil;Oh, Seung Won;Moon, Myoung cheol
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.548-556
    • /
    • 2021
  • This study was conducted to investigate the applicability of lignocellulosic fiber and coconut shell activated carbon (CSA) for the production of a particulate matter (PM)-reducing air-filter as raw materials to solve the environmental problems of non-woven fabrics. CSA had a good potential to use as a raw material of air-filter for reducing volatile organic compounds as well as noxious metals, and reduction capability of the CSA was 5 times higher than that of wood fiber. Natural adhesives formulated with proteinaceous wastes mostly were applied successfully to fabricate air-filters with the shape of fiberboard. The air-filter fabricated with the minimum target density of 200 kg/m3 and the maximum CSA-content of 40 wt% in fiberboard had a good manageable strength. However, the fiberboard filters was required to make vent-holes for improving an air-permeability of the filters. Size of the CSA particles was adjusted to greater than 2 mesh with the consideration of strength and formability of the fiberboard. Three-layers fiberboard that only wood fiber and the mixture of wood fiber and CSA were formed in the surface and middle layers, respectively, was determined to the optimal condition for the production of air-filters. In addition, traditional Korean paper handmade from mulberry trees (TKP) showed a good PM-reducing property as an air-filter. It is concluded that air-filtering set composed of fiberboard with vent-holes and TKP instead of conventional air-filters made with non-woven fabrics can be used as a filter for reducing the concentrations of PM, VOC and noxious metals existed in indoor and outdoor spaces.