• Title/Summary/Keyword: Void Rate

Search Result 264, Processing Time 0.023 seconds

A Void Fraction Measurement Technique by Single Camera and Its Application (단일 카메라를 이용한 이상유동 기포율 측정방법의 개발과 응용)

  • Choi, Dong-Whan;Yoo, Jung-Yul;Song, Jin-Ho;Sung, Jae-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.11
    • /
    • pp.904-911
    • /
    • 2007
  • A measurement technique fur void fraction has been proposed using a time-resolved two-phase PIV system and the bubble dynamics has been investigated in gas-liquid two-phase flows. For the three-dimensional evaluation of the bubble information, both the images from the front and side views are simultaneously recorded into a high speed CCD camera by reflecting the side view image on a $45^{\circ}$ oriented mirror to be juxtaposed with the front view image. Then, a stereo-matching technique is applied to calculate the void fraction, bubble size and shape. To obtain the rising bubble velocities, the 2-frame PTV method was adopted. The present technique is applied to freely rising bubby flows in stagnant liquid. The results show that the increase of bubble flow rate gives rise to the increase of bubble size and rising velocity at first. If it goes over a certain level, the rising velocity becomes constant and the horizontal velocity grows bigger instead due to the obstruction of other bubbles.

A Case Study for Influence of Form-oil on Surface Condition of Steam-cured Concrete (증기양생 콘크리트 표면상태에 대한 박리제의 영향 사례연구)

  • Han, Sang Hoon;Yoon, Ju Yong;Hong, Ki Nam;Choi, Jae Wan;Lim, June Woo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.52-56
    • /
    • 2013
  • The purpose of this study is to evaluate the influence of form-oil on steam-cured concrete surface condition. Based, viscosity(high, medium, low) and flash point($26^{\circ}C$, $70^{\circ}C$) of form oil were considered as test variables. The digital image process method was applied for the extraction of air-void area from concrete surface. Test result showed that oil-based form oil reduced air-void by approximately 46% compared to water-based form oil, and the higher the viscosity was, the smaller air-void rate was. In addition, it was conformed that flash point of form oil had a considerable influence on the surface condition of steam-cured concrete.

Effect of Shell Structure of Artificial Lightweight Aggregates on the Emission Rate of Absorbed Water (인공경량골재의 표피층 구조가 흡수된 물의 방출속도에 미치는 영향)

  • Kang, Seung-Gu
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.11
    • /
    • pp.750-754
    • /
    • 2008
  • The artificial aggregates with dense surface layer (shell) was fabricated and the dependence of water emission rate upon the shell structures was studied. The EAF dust containing many flux components and waste white clay with ignition loss of above 48% were used as for liquid phase and gas forming agents during a sintering process respectively. In addition, the shell structure was modified with various processes and the modification effect on water emission rate was analyzed. The pores under $10{\mu}m$ were found in the sintered artificial light aggregates and disappeared by incorporating to a bigger pore during re-sintering. The water emission rate in an initial step depended on a void content of aggregates filled in a bottle rather than a shell structure. But, after 7 days where the water emission of the aggregate with a shell is above 40%, the shell of aggregates suppressed the water emission. The core of aggregates was exposed and most shell was lost when crushed to smaller size so, the ability for suppressing water emission of the crushed aggregates decreased. The activation energy for the water emission was $3.46{\pm}0.25{\times}10^{-1}$J/mol for the most specimens showing that the activation energy is irrelevant to the pore size distribution and shell structure.

Evaluation of Permeability and Related Soil Characteristics Based on Pore Pressure Measurement during Consolidation by Radial Drainage (방사배수 압밀 중 위치별 간극수압 측정을 통한 투수계수와 관련물성치의 결정방법)

  • Yune, Chan-Young;Chun, Sung-Ho;Chung, Choog-Ki;Lee, Won-Tekg
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1C
    • /
    • pp.9-17
    • /
    • 2008
  • In this research, an analytical solution for the coefficient of permeability of soils during consolidation is suggested. The pore pressure and the flow rate measurements at different locations during consolidation are utilized. The void ratio and volume compressibility of soils under consolidation are also estimated. A large consolidation testing device, possible in both vertical and radial drainage is designed and manufactured. And consolidation test with kaolinite soils were performed under radially inward drainage direction. Pore pressures in varying radial distances and flow rate with time were measured as well as vertical deformations. From the test results, the changes of permeability, volume compressibility and void ratio under consolidation and their spatial variations are estimated. Thus the proposed solution is verified by comparing with the experimentally estimated test results. In addition, it is confirmed that permeability, void ratio and volume compressibility decrease as consolidation and loading steps progress. Also, these soil characteristics increase with radial distant from drainage boundary, where lowest values observed, and slightly decrease as approaching undrained boundary.

Modeling Heterogeneous Wall Nucleation in Flashing Flow of Initially Subcooled Water

  • Park, Jong-Woon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.241-246
    • /
    • 1996
  • An analytical model to calculate rate of vapor generation due to heterogeneous wall nucleation in flashing flow is developed. In the present model, an important parameter of the vapor generation term, i.e. nucleation site density is calculated by integrating its probability distribution function with respect to active cavity radius. The limits of integration are minimum and maximum active cavity radii, and these are formulated using an active cavity model for nucleate boiling. This formulation, therefore. can statistically account for the effect of surface specific thermo-physical and geometric conditions on the vapor generation rate and flashing inception. For verifying the adequacy of the present model, steady state two-fluid and the bubble transport equations are solved with applicable constitutive equations. The applicable region of the bubble transport equation is also extended to churn-turbulent flow regime to predict interfacial area concentration at high void fraction. Predicted results in terms of axial pressure and void fraction profiles along the channels are compared with experimental data of Super Moby Dick and BNL Reasonable agreements have been achieved and this shows the applicability of the present model to flashing flow analysis.

  • PDF

A Numerical Study on the Two-Phase Natural Circulation Flow in Reactor Cavity under External Vessel Cooling (원자로 외벽냉각시 원자로공동에서의 자연순환 이상유동에 대한 수치적 연구)

  • Kim, Hong-Min;Seo, Jun-Woo;Kim, Kwang-Yong;Park, Rae-Joon;Ha, Kwang-Soon;Kim, Sang-Baik
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.781-785
    • /
    • 2003
  • This work presents a numerical analysis of two-phase natural circulation flow in reactor cavity under external vessel cooling. Steady, incompressible, three-dimensional Reynolds-averaged Navier-Stokes equations for multiphase flows with zero equation turbulence model are solved to predict the shear key effect on the circulation rate of cooling water and the distribution of void fraction according to the different mass flow of inlet air. Results show that shear key has a positive effect on the circulation rate of cooling water and induce a local increase of void fraction below the shear key, but not remarkably.

  • PDF

Measurements of Void Concentration Parameters in the Drift-Flux Model (상대유량 모델내의 기포분포계수 측정에 관한 연구)

  • Yun, B.J.;Park, G.C.;Chung, C.H.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.91-101
    • /
    • 1993
  • To predict accurately the thermal hydraulic behavior of light water reactors during normal or abnormal operation, the accurate estimation of the void distribution is required. Up to date, many techniques for predicting void fraction of two-phase flow systems have been suggested. Among these techniques, the drift-flux model is widely used because of its exact calculation ability and simplicity. However, to get more accurate prediction of void fraction using drift-flux model, slip and flow regime effects must be considered more properly In the drift-flux method, these two effects are accounted for by two drift-flux parameters ; $C_{o}$ and (equation omitted). At earlier stage, $C_{o}$ is measured in a circular tube. In this study, $C_{o}$ is experimentally determined by measuring local void fraction and vapor velocity distribution in a rectangular subchannel having 4 heating rods which simulates nuclear subchannels. The measurements are peformed with two-electrical conductivity probes which are known to be adequate for measuring local parameters. The experiments are performed at low flow rate and the system pressure less than 3 atmo spheric pressure. In this experiment, (equation omitted), is not measured, but quoted from well-known empirical correlation to formulate $C_{o}$. Finally, $C_{o}$ is expressed as a function of channel averaged void fraction. fraction.

  • PDF

A Study on Coolant Mixing in Multirod Bundle Subchannels

  • Cha, Jong-Hee;Cho, Moon-Haeng
    • Nuclear Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.19-25
    • /
    • 1970
  • A study was conducted on the coolant mixing between water flowing in two adjacent subchannels. Measurements were made of the quantity of mass transferred between a larger rectangular channel and a smaller triangular channel in a 19-rod fuel bundle under the conditions of single phase flow and air-water two-phase flow. The results of the experiments showed that the low mixing rate appears in single phase flow, and high mixing rate was measured in air-water two-phase flow Mixing rate decreases with the increasing of air void fraction during the air-water flow. It seems that the high mixing rate in the air-water flow was caused due to adequate agitation of the chaotic air void.

  • PDF

IDENTIFICATION OF TWO-DIMENSIONAL VOID PROFILE IN A LARGE SLAB GEOMETRY USING AN IMPEDANCE MEASUREMENT METHOD

  • Euh, D.J.;Kim, S.;Kim, B.D.;Park, W.M.;Kim, K.D.;Bae, J.H.;Lee, J.Y.;Yun, B.J.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.613-624
    • /
    • 2013
  • Multi-dimensional two-phase phenomena occur in many industrial applications, particularly in a nuclear reactor during steady operation or a transient period. Appropriate modeling of complicated behavior induced by a multi-dimensional flow is important for the reactor safety analysis results. SPACE, a safety analysis code for thermal hydraulic systems which is currently being developed, was designed to have the capacity of multi-dimensional two-phase thermo-dynamic phenomena induced in the various phases of a nuclear system. To validate the performance of SPACE, a two-dimensional two-phase flow test was performed with slab geometry of the test section having a scale of $1.43m{\times}1.43m{\times}0.11m$. The test section has three inlet and three outlet nozzles on the bottom and top gap walls, respectively, and two outlet nozzles installed directly on the surface of the slab. Various kinds of two-dimensional air/water flows were simulated by selecting combinations of the inlet and outlet nozzles. In this study, two-dimensional two-phase void fraction profiles were quantified by measuring the local gap impedance at 225 points. The flow conditions cover various flow regimes by controlling the flow rate at the inlet boundary. For each selected inlet and outlet nozzle combination, the water flow rate ranged from 2 to 20 kg/s, and the air flow rate ranged from 2.0 to 20 g/s, which corresponds to 0.4 to 4 m/s and 0.2 to 2.3 m/s of the superficial liquid and gas velocities based on the inlet port area, respectively.

Flow Measurement in Bubbly and Slug Flow Regimes Using The Electromagnetic Flowmeter Developed (전자기유량계를 이용한 기포 및 슬러그 유동 측정방법 연구)

  • Cha, Jae-Eun;Ahn, Yeh-Chan;Seo, Kyung-Woo;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1559-1569
    • /
    • 2002
  • In order to investigate the characteristics of electromagnetic flowmeter in two -phase flow, an AC electromagnetic flowmeter was designed and manufactured. In various flow conditions, the signals and noises from the flowmeter were obtained and analyzed by comparison with the observed flow patterns with a high speed CCD camera. The experiment with the void simulators in which rod shaped non-conducting material was used was carried out to investigate the effect of the bubble position and the void fraction on the flowmeter. Based on the results from the void simulator, two -phase flow experiments encompassed from bubbly to slug flow regime were conducted. The simple relation $\Delta$ $U_{TP}$ = $\Delta$ $U_{SP}$ (l-$\alpha$) was verified with measurements of the potential difference and the void fraction. Due to the lack of homogeneity in a rent two -phase flow, the discrepancy between the relation and the present measurement was slightly increased with void fraction and also liquid volumetric flux jf. Whereas there is no difference in the shape of the raw signal between single-phase flow and bubbly flow, the signal amplitude for bubbly flow is higher than that for single -phase flow at the same water flow rate, since the passage area of the water flow is reduced. In the case of slug flow, the phase and the amplitude of the flowmeter output show dramatically the flow characteristics around each slug bubble and the position of a slug bubble itself. Therefore, the electromagnetic flowmeter shows a good possibility of being useful for identifying the flow regimes.ul for identifying the flow regimes.