• Title/Summary/Keyword: Void Distribution

Search Result 271, Processing Time 0.023 seconds

A Study on the partial Discharge Characteristics according to the Distribution pattern of voids within LDPE (보이드 분포 형태에 따른 LDPE의 부분 방전 특성 연구)

  • Shin, Doo-Seong;Jeon, Seung-Ik;Lee, Jun-Ho;Yun, Do-Hong;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1081-1084
    • /
    • 1995
  • Internal voids located within an insulation will arise partial discharge that causes local breakdown and even the entire insulation breakdown. For HV apparatuses, it is usual case that several voids are formed within non-uniform electric field condition rather than single void within uniform field, which can be solved analitically. The purpose of this work is to study partial discharge and breakdown characteristics of an insulation according to the distribution pattern of two disc-type voids that are located within non-uniform field. The results from numerical field analysis and experiments show that the electric field within the voids decreases as they are arranged more serially, which accordingly results in the increase of partial discharge inception field(PDIF) much higher than that of single void model. With parallel arranged voids, PDIF is almost the same as that of single void model. On the other hand, AC breakdown strength decreases as voids are arranged more serially, which is a natural result considering the reduction of effective insulation thickness. For parallel voids, this effect cannot he noticed where as they show different pattern compared with single void and serial void models in $\Phi$-Q-N analysis. Considering these results may leads us to the conclusion that, in the evaluation of insulating products through PD test, it is not sufficient to determine only PDIV or existence of PD at predetermined voltage level. We could evaluate more accurately by considering all the available data such as PDIV, PD magnitude, PD occurring phase, number of PD pulses, and etc.

  • PDF

Prediction of the Degree of Saturation Using the Soil-Water Characteristic Curves on an Unsaturated Soil (흙-수분 특성곡선 방정식을 이용한 포화도의 예측)

  • Song, Chang-Seob
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.6
    • /
    • pp.61-69
    • /
    • 2004
  • The aim of the work described in this paper was to confirm the application of the equation of the soil-water characteristic curves on an unsaturated soil. A series of suction test for unsaturated soils was conducted on the selected 4 kinds of soil using modified pressure extractor apparatus. And it was carried out to analyse The experimental parameters which can be describe the soil-water characteristics, were determined by using the data obtained from the experiment. From the results, it was found that The matric suction varied according to the grain size distribution, amount of fine grain particles and void ratio. Also it was found that the residual degree of saturation was decreased with in crease of the void ratio, but the pore size distribution index and air entry value were increased with in crease of the void ratio. And The application of the soil-water characteristic curve equation was confirmed for the various conditions and the various state by the comparison between the measured degree of saturation and the predicted degree of saturation.

A Study on the Ship Wake Model under the Ocean Environment (해상 환경을 고려한 수상함 항적 모델 연구)

  • Bae, Ho Seuk;Kim, Won-Ki;Son, Su-Uk;Kim, Woo-Shik;Park, Joung-Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.22-30
    • /
    • 2021
  • The ship wake generated by rotation of the propeller yields changes of characteristics of sound wave such as attenuation and scattering. To develope a battle field environment simulator for military purposes, it is very important to understand acoustical properties of ship wake. Existing research results have limitations in direct application because they performed under simple conditions or model ships were applied. In this study, we developed a ship wake generation model based on the ship's geometric wake distribution theory. The model can provide spatial distribution and void fraction with various marine environments as well as ship size. Through the developed model, geometric distribution features of ship wake according to the ship's maneuvering conditions were successfully simulated. In addition, changes of the bubble void fraction with time at any location within the battle field environment were identified. Therefore, the developed model is expected to be used in the development of a simulator to measure the acoustic characteristics of the ship wake.

Evaluation of Air Void System and Permeability of Latex-Modified Concrete by Image Analysis Method

  • Jeong, Won-Kyong;Yun, Kyong-Ku;Hong, Seung-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • v.19 no.1E
    • /
    • pp.41-48
    • /
    • 2007
  • Addition of latex to concrete is known to increase its durability and permeability. The purpose of this study is to analyze air void systems in latex-modified concretes using a reasonable and objective method of image analysis with such experimental variables as water-cement (w/c) ratios, latex contents (0%, 15%) and cement types (ordinary portland cement (OPC), high-early strength (HES) cement and very-early strength (VES) cement). The results are analyzed by spacing factor, air volume (content) after hardening, air void distribution and structure. Additionally, air void systems and permeability of latex-modified concrete (LMC) are compared by a correlation analysis. The results are as follows. The LMC of the same w/c ratio showed better air entraining (AE) effect than OPC with AE water reducer. The VES-LMC showed that the quantity of entrained air below $100{\mu}m$ increased more than four times. For the case of HES-LMC, microscopic entrained air between the range of 50 to $500{\mu}m$ increased greater than 7 times even in the absence of anti-foamer. Although spacing factor was measured rather low, the permeability of latex-modified concrete was good. It is construed that air void system does not have a considerable effect on the property of latex-modified concrete, but latex film (membrane) has a definite influence on the durability of LMC.

Relationship between void fraction and mixing in bubble column flow (기포탑 유동에서의 기포분율과 혼합정도의 상관관계)

  • Zahidul, Islam MD;Lee, Jubeom;Park, Hyungmin
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.1
    • /
    • pp.41-46
    • /
    • 2017
  • Control of mixing and transport processes are the key areas that can be benefited by understanding the hydrodynamics in gas-liquid two-phase flows. In particular, the enhanced bubble-induced liquid-phase mixing is known to be a function of void fraction distribution, gas phase velocity and so on. To further our insight on the characteristics of the liquid-phase mixing induced by the bubbles, in the present study, we experimentally investigate the mixing performance of a rectangular bubble column while changing the void fraction from 0.006 to 0.075%. A shadowgraphy technique is used to measure the gas-phase properties such as void fraction and size/velocity of bubbles. On the other hand, we use dye visualization with low diffusive buoyant dye to directly measure the level of mixing. Finally, we confirm that the time taken for full mixing scales with the inverse of volume void fraction.

Comprehensive Analysis on Wrinkled Patterns Generated by Inflation and Contraction of Spherical Voids

  • Lim, Min-Cheol;Park, Jaeyoon;Jung, Ji-Hoon;Kim, Bongsoo;Kim, Young-Rok;Jeong, Unyong
    • International Journal of Precision Engineering and Manufacturing-Green Technology
    • /
    • v.5 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • We comprehensively investigated the wrinkles of a stiff layer covering a spherical void embedded in a rubber matrix after the void experienced inflation or contraction. We developed an easy experimental way to realize the inflation and contraction of the voids. The inflation took place in a void right beneath the surface of the matrix and the contraction happened in a void at the bottom of the rubber matrix. In the inflation, the wrinkle at the center of the deformation was random, and the pattern propagated into rabyrinthine, herringbone, and then oriented parallel lines as the position was away from the center of the inflation to the edge. The cracks were concentric, which were perpendicular to the parallel wrinkled pattern. In the contraction, the wrinkle was simply concentric around the surface of the void without any crack. The cracks were found only near the center of the deformation. The strain distribution in the stiff layer after the inflation and contraction was theoretically analyzed with simulations that were in excellent agreement with the experimental results.

Experimental study of the effect of microstructure on the permeability of saturated soft clays

  • Chen, Bo;Sun, De'an;Jin, Pan
    • Geomechanics and Engineering
    • /
    • v.18 no.1
    • /
    • pp.49-58
    • /
    • 2019
  • The effect of microstructure on the permeability of two saturated marine clays was studied through a series of falling head permeability tests and mercury intrusion porosimetry (MIP) tests. The key findings from this experimental study include the following results: (1) The permeability of undisturbed specimens is larger than that of reconstituted specimens at the same void ratio due to different soil fabrics, i.e., the pore size distributions (PSDs), even though they have the similar variation law in the permeability versus void ratio. (2) Different permeabilities of undisturbed and reconstituted specimens at the same void ratio are mainly caused by the difference in void ratio of macro-pores based on the MIP test results. (3) A high relevant relation between $C_k$ ($C_k$ is the permeability change index) and $e*_{10}$, can be found by normalizing the measured data both on undisturbed or reconstituted specimens. Hence, the reference void ratio $e*_{10}$, can be used as a reasonable parameter to identify the effect of soil fabric on the permeability of saturated soft clays.

Influence of Air Void Characteristic on Chloride Diffusion Coefficient and Compressive Strength of Concrete using Urea and Sulfur (요소와 유황을 첨가한 콘크리트의 압축강도와 염화물 확산계수에 대한 공극특성의 영향)

  • Kim, Jae Hyun;Hong, Ki Nam;Jeon, Byeong Gu
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.75-81
    • /
    • 2016
  • This study presents the effect of urea and sulfur admixture on compressive strength, chloride diffusion coefficient, and internal void distribution of concrete. Compressive strength of concretes with urea admixture by 5% increased by 5% relative to Control. However, that of concretes with urea admixture over 10% decreased. Chloride diffusion coefficient of concrete with urea and sulfur admixture decreased by 40% relative to Control. Additionally, the volume of internal void of concrete with urea and sulfur admixture decreased by 20% relative to Control. Therefore, it can be mentioned from test results that the use of adequate urea and sulfur admixture improves the mechanical properties and durability of concrete.

Dyeing Study on DMF-Modified Polyesters for Morphology Characterization

  • Park, Myung-Ja
    • The International Journal of Costume Culture
    • /
    • v.5 no.2
    • /
    • pp.53-65
    • /
    • 2002
  • Morphology of polyester fiber was physically modified by solvent treatment. PET fiber was treated with N,N-dimethylformamide (DMF) at 100, 120, $140^{circ}C$ for 10 minutes without tension. The structural changes in the morphology of DMF-induced modified PET fiber were FTIR and SEM analysis. Also dyeing behavior of DMF-treated polyester fibers with various disperse dyes was studied to detect changes of amorphous area in fine structure. DMF treatment resulted in increases in total void content, degree of crystallinity, trans isomer content, chain folding, segmental mobility and molecular packing, but it resulted in decreases in amorphous orientation, intermolecular forces and individual void size through longitudinal shrinkage, lateral welling and removal of oligomers. Void-size distribution could be estimated from the dye uptake with various sizes of disperse dyes. In contrast to the large increases in dye uptake with small dye molecules, there is no and little dye uptake with the bulkiest dye, which means that void size is bigger or smaller than the volume of each dye. Diffusion rates of dye molecules showed increases. This dyeing study revealed that the disperse dyeing is very effective method for characterizing the internal morphology of polyester fiber.

  • PDF

Enthalpy and Void Distributions in Subchannels of PHWR Fuel Bundles

  • Park, J.W.;Choi, H.;Rhee, B.W.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.502-507
    • /
    • 1998
  • Two different types the CANDU fuel bundles hue been modeled for the ASSERT-IV code subchannel analysis. From calculated values of mixture enthalpy and void paction distributions in the fuel bundles, it is found that net buoyancy effect is pronounced in the central region of the DUPIC fuel bundle when compared with the standard CANDU fuel bundle. It is also found that the central region of the DUPIC fuel bundle can be cooled more efficiently than that of the standard fuel bundle. From calculated mixture enthalpy distribution at the exit of fuel channel, it is found that the mixture enthalpy and void fraction can be highest in the peripheral region of the DUPIC fuel bundle. On the other hand, the enthalpy and the void fraction were found to be highest in the central region of the standard CANDU fuel bundle at the exit of the fuel channel. This study shows that the subchannel analysis is very useful assessing thermal behavior of the fuel bundle that could be used in CANDU reactors.

  • PDF