• Title/Summary/Keyword: Vital power

Search Result 272, Processing Time 0.026 seconds

Vital Area Identification Analysis of A Hypothetical Nuclear Facility Using VIPEX (VIPEX를 이용한 가상 원자력시설의 핵심구역 파악 분석)

  • Lee, Yoon-Hwan;Jung, Woo-Sik;Lee, Jin-Hong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.87-95
    • /
    • 2011
  • The urgent VAI(Vital Area Identification) method development is required since 'The Act of Physical Protection and Radiological Emergency' that is established in 2003 requires an evaluation of physical threats in nuclear facilities and an establishment of physical protection in Korea. The KAERI(Korea Atomic Energy Research Institute) has developed the VAI methodology and VAI software called as VIPEX(Vital area Identification Package EXpert) for identifying the vital areas. This study is to demonstrate the applicability of KAERI's VAI methodology to a hypothetical facility, and to identify the importance of information of cable and piping runs when identifying the vital areas. It is necessarily needed to consider cable and piping runs to determine the accurate and realistic TEPS(Top Event Prevention Set). If the information of cable and piping runs of a nuclear power plant is not considered when determining the TEPSs, it is absolutely impossible to acquire the complete TEPSs, and the results could be distorted by missing it. The VIPEX and FTREX(Fault Tree Reliability Evaluation eXpert) properly calculate MCSs and TEPSs using the fault tree model, and provide the most cost-effective method to save the VAI and physical protection costs.

Performance Analysis of Multiple-Hop Wireless Body Area Network

  • Hiep, Pham Thanh;Hoang, Nguyen Huy;Kohno, Ryuji
    • Journal of Communications and Networks
    • /
    • v.17 no.4
    • /
    • pp.419-427
    • /
    • 2015
  • There have been increases in the elderly population worldwide, and this has been accompanied by rapid growth in the health-care market, as there is an ongoing need to monitor the health of individuals. Wireless body area networks (WBANs) consist of wireless sensors attached on or inside the human body to monitor vital health-related problems, e.g., electrocardiograms (ECGs), electroencephalograms (EEGs), and electronystagmograms (ENGs). With WBANs, patients' vital signs are recorded by each sensor and sent to a coordinator. However, because of obstructions by the human body, sensors cannot always send the data to the coordinator, requiring them to transmit at higher power. Therefore, we need to consider the lifetime of the sensors given their required transmit power. In the IEEE 802.15.6 standard, the transmission topology functions as a one-hop star plus one topology. In order to obtain a high throughput, we reduce the transmit power of the sensors and maintain equity for all sensors. We propose the multiple-hop transmission for WBANs based on the IEEE 802.15.6 carrier-sense multiple-access with collision avoidance (CSMA/CA) protocol. We calculate the throughput and variance of the transmit power by performing simulations, and we discuss the results obtained using the proposed theorems.

A FSK Radio-telemetry System for Monitoring Vital Signs in UHF Band (UHF 대역 FSK에 의한 생체신호 무선 전송장치의 개발)

  • Park D.C.;Lee H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.255-260
    • /
    • 2000
  • This paper presents a radio-telemetry patient monitor. which is used for intensive cal?e units. emergency and surgical operation rooms to monitor continuously patients' vital signs. The radio-telemetry patient monitor consists of a vital sign acquisition unit. wireless data transmission units and a vital sign-monitoring unit. The vital sign acquisition unit amplifies biological signals, performs analog signal to serial digital data conversion using the one chip micro-controller. The converted digital data is modulated FSK in UHF band using low output power and transmitted to a remote site in door. In comparison with analog modulation. FSK has major advantages to improve performance with respect to noise resistance with fower error and the potential ability to process and Improve quality of the received data. The vital sign-monitoring unit consists of the receiver to demodulate the modulated digital data, the LCD monitor to display vital signs continuously and the thermal head printer to record a signal.

  • PDF

Analysis on operating trends of Protective relay (보호계전기 동작실태 분석)

  • Jang, Sung-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.188-190
    • /
    • 2000
  • Protective Relays are vital components of power systems. The role of the protective relaying device is more important than ever. Therefore, We have investigated the operating trends of protective relay from 1991 to 1999. we anticipate that reliability in the power systems increases by improving design, manufacture, construction technology and maintenance method of the protective relay.

  • PDF

Remote Vital Signal Monitoring System Based on Wireless Sensor Network Using Ad-Hoc Routing

  • Walia Gaurav;Lee Young-Dong;Chung Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.2
    • /
    • pp.67-70
    • /
    • 2006
  • A distributed healthcare monitoring system prototype for clinical and trauma patients was developed, using wireless sensor network node. The proposed system aimed to measure various vital physiological health parameters like ECG and body temperature of patients and elderly persons, and transfer his/her health status wirelessly in Ad-hoc network to remote base station which was connected to doctor's PDA/PC or to a hospital's main Server using wireless sensor node. The system also aims to save the cost of healthcare facility for patients and the operating power of the system because sensor network is deployed widely and the distance from sensor to base station was shorter than in general centralized system. The wireless data communication will follow IEEE 802.15.4 frequency communication with ad-hoc routing thus enabling every motes attached to patients, to form a wireless data network to send data to base-station, providing mobility and convenience to the users in home environment.

Non-Contact Vital Signal Sensor Based on Impedance Variation of Resonator (공진기의 임피던스 변화에 근거한 비접촉 생체 신호 센서)

  • Kim, Kee-Yun;Kim, Sang-Gyu;Hong, Yunseog;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.813-821
    • /
    • 2013
  • In this paper, a vital signal sensor based on impedance variation of resonator is presented. Proposed vital signal sensor can detect the vital signal, such as respiration and heart-beat signal. System is composed of resonator, oscillator, surface acoustic wave (SAW) filter, and power detector. The cyclical movement of a dielectric such as a human body, causes the impedance variation of resonator within the near-field range. So oscillator's oscillation frequency variation is effected on resonator's resonant frequency. SAW filter's skirt characteristic of frequency response can be transformed a small amount of frequency deviation to a large variation. Aim to enhance the existing sensor detection range, proposed sensor operates in 870 MHz ISM band, and detect respiration and heart-beat signal at distance of 120 mm.

Vital Signal Monitoring Simulation System by Various Visual Stimulus (다양한 시각자극에 따른 생체신호 모니터링 시뮬레이션 시스템)

  • Chung, Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • With the development of next IT convergence technology and the construction of infrastructure for personalized services, the importance of services based on user's sensibility status and vital signal is being spotlighted. It is the most crucial factor for the strategy of sensibility engineering to investigate student's vital signal according to the sensibility. In this paper, we proposed the vital signal monitoring simulation system by the various visual stimulus. The proposed method obtained the student's vital signal by the various visual stimulus. And the power spectrum analysis using the fast fourier transform is evaluated the activity level between the sympathetic and the parasympathetic. The analyzed result is monitoring the sensibility by displaying the heath signal light. To evaluate the sensibility between the high school's students and the university's students, we conducted SD profile and paired T-tests so as to verify usefulness. This evaluation found that the difference of sensibility activity by positive and negative stimulus was statistically meaningful. Ultimately, this paper suggests empirical application to verify the adequacy and the validity.

A Study on the Diagnosis and Failure Mode of AOV Actuators (공기구동밸브 구동기의 고장진단에 관한 연구)

  • Jeong, Gyeong-Yeol;Kim, Byeong-Deok;O, Sang-Hun
    • 연구논문집
    • /
    • s.34
    • /
    • pp.47-58
    • /
    • 2004
  • Power plants rely on air operated valves for the proper operation of many plant system. Many significant problems arise in vital systems of power plants due to air operated valve failures. This paper deals with the diagnosis technique and data acquisition method of an AOV actuator peformance. We constructed AOV diagnosis system and performed some tests to find out whether an AOV actuator was properly designed.

  • PDF

Communications Protocol Used in the Wireless Token Rings for Bird-to-Bird

  • Nakajima, Isao;Juzoji, Hiroshi;Ozaki, Kiyoaki;Nakamura, Noboru
    • Journal of Multimedia Information System
    • /
    • v.5 no.3
    • /
    • pp.163-170
    • /
    • 2018
  • We developed a multicast communication packet radio protocol using a time-sharing tablet system ("wireless token ring") to achieve the efficient exchange of files among packet radio terminals attached to swans. This paper provides an overview of the system and the protocol of the packet communications. The packet device forming the main part of the transceiver developed is the Texas Instruments CC2500. This device consists of one call-up channel and one data transmission channel and could improve error frame correction using FEC (forward error correction) with 34.8 kbps MSK and receiving power of at least -64 dBm (output 1 dBm at distance of 200 m using 3 dBi antenna). A time-sharing framework was determined for the wireless token ring using call sign ordinals to prevent transmission right loss. Tests using eight stations showed that resend requests with the ARQ (automatic repeat request) system are more frequent for a receiving power supply of -62 dBm or less. A wireless token ring system with fixed transmission times is more effective. This communication protocol is useful in cases in which frequency resources are limited; the energy consumed is not dependent on the transmission environment (preset transmission times); multiple terminals are concentrated in a small area; and information (position data and vital data) is shared among terminals under circumstances in which direct communication between a terminal and the center is not possible. The method allows epidemiological predictions of avian influenza infection routes based on vital data and relationships among individual birds based on the network topology recorded by individual terminals. This communication protocol is also expected to have applications in the formation of multiple in vivo micromachines or terminals that are inserted into living organisms.