• Title/Summary/Keyword: Visual imaging

Search Result 626, Processing Time 0.025 seconds

Computational Integral Imaging Reconstruction of 3D Object Using a Depth Conversion Technique

  • Shin, Dong-Hak;Kim, Eun-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.131-135
    • /
    • 2008
  • Computational integral imaging(CII) has the advantage of generating the volumetric information of the 3D scene without optical devices. However, the reconstruction process of CII requires increasingly larger sizes of reconstructed images and then the computational cost increases as the distance between the lenslet array and the reconstructed output plane increases. In this paper, to overcome this problem, we propose a novel CII method using a depth conversion technique. The proposed method can move a far 3D object near the lenslet array and reduce the computational cost dramatically. To show the usefulness of the proposed method, we carry out the preliminary experiment and its results are presented.

Wide Field-of-View Imaging Using a Combined Hyperbolic Mirror

  • Yi, Sooyeong;Ko, Youngjun
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.336-343
    • /
    • 2017
  • A wide field-of-view (FOV) image contains more visual information than a conventional image. This study proposes a new type of hyperbolic mirror for wide FOV image acquisition. The proposed mirror consists of a hyperbolic cylindrical section and a bowl-shaped hyperbolic omnidirectional section. Using an imaging system with this mirror, it is possible to achieve a $213.8^{\circ}$ horizontal and a $126.94^{\circ}$ vertical maximum FOV. Parameters of each section of the mirror are designed to be continuous at the junction of the two parts, and the resultant image is seamless. The image-acquisition model is obtained using ray-tracing optics. To rectify the geometrical distortion of the original image due to the mirror, an image-restoration algorithm based on conformal projection is presented in this study. The performance of the proposed imaging system with the hyperbolic mirror and its image-restoration algorithm are verified by experiments.

Three Dimensional Volume Reconstruction of Polyhedral Objects Using X-ray Stereo Images

  • Roh, Young-Jun;Kim, Byung-Man;Cho, Hyung-Suck
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.28.2-28
    • /
    • 2001
  • Three dimensional shape measurement techniques are widely needed in industries for product quality monitoring and control. X-ray imaging method is a promising technology to achieve three-dimensional Information, both the surface and inner structure of an object, since it can overcome the limitations of conventional visual or optical methods such as an occlusion problem or surface reflection properties. In this paper, we propose three dimensional volume reconstruction method based on x-ray stereo imaging technology. Here, the stereo images of an object from two different views are taken by changing the object pose rather than moving imaging plane as in conventional stereo vision method. We propose a series of image processing techniques to extract the features efficiently from x-ray images, where the occluded features in case of normal camera vision could be found ...

  • PDF

Coronary Artery Calcium Data and Reporting System (CAC-DRS): A Primer

  • Parveen Kumar;Mona Bhatia
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • The Coronary Artery Calcium Data and Reporting System (CAC-DRS) is a standardized reporting method for calcium scoring on computed tomography. CAC-DRS is applied on a per-patient basis and represents the total calcium score with the number of vessels involved. There are 4 risk categories ranging from CAC-DRS 0 to CAC-DRS 3. CAC-DRS also provides risk prediction and treatment recommendations for each category. The main strengths of CAC-DRS include a detailed and meaningful representation of CAC, improved communication between physicians, risk stratification, appropriate treatment recommendations, and uniform data collection, which provides a framework for education and research. The major limitations of CAC-DRS include a few missing components, an overly simple visual approach without any standard reference, and treatment recommendations lacking a basis in clinical trials. This consistent yet straightforward method has the potential to systemize CAC scoring in both gated and non-gated scans.

The Effect of Background Grey Levels on the Visual Perception of Displayed Image on CRT Monitor (CRT 모니터의 배경(背景) 계조도(階調度)가 영상의 시각인식(視覺認識)에 미치는 영향)

  • Kim, Jong-Hyo;Park, Kwang-Suk;Min, Byoung-Goo;Lee, Choong-Woong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.18-21
    • /
    • 1991
  • In this paper, the effect of background grey levels on the visual perception of target image displayed on CRT monitor has been investigated. The purpose of this study is to investigate the efficacy of CRT monitor as a display medium of image information especially in medical imaging field. Three sets of experiments have been performed in this study; the first was to measure the luminance response of CRT monitor and to find the best fitting equation, and the second was the psychophysical experiment measuring the threshold grey level difference between the target image and the background required for visual discrimination for various background grey levels, and the third was to develop a visual model that is predictable of the threshold grey level difference measured in the psychophysical experiment. The result of psycophysical experiment shows that the visual perception performance is significantly degraded in the range of grey levels lower than 50, which is turned out due to the low luminance change of CRT monitor in this range while human eye has been adapted to relatively bright ambient illumination.

  • PDF

Convergence Point Adjustment Methods for Minimizing Visual Discomfort Due to a Stereoscopic Camera

  • Ha, Jong-Soo;Kim, Dae-Woong;Kim, Dong Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.4
    • /
    • pp.246-251
    • /
    • 2014
  • The recent rise of the three-dimensional television (3DTV) industry has led to a wide exploitation of the dual-lens stereoscopic camera. However, when the zoom-in function is used, it is possible that a camera object is magnified only with a fixed convergence point, thereby leading to visual discomfort. In this paper, we propose several methods based on which a convergence point can be adjusted to prevent visual discomfort during zoom-in for a dual-lens stereoscopic camera. Further, we produce 3D contents by applying the proposed methods to certain cases and at certain distances and conduct a subjective evaluation. On the subjective evaluation, 48 subjects watch the 3D contents created by the proposed methods and score the stages of the visual comfort. The result of the subjective evaluation shows that some of the proposed methods are more efficient than the others. We hope that these proposed high-efficiency methods can be applied to produce a dual-lens stereoscopic camera that allows convenient stereoscopic photography.

Traffic Estimation Method for Visual Sensor Networks (비쥬얼 센서 네트워크에서 트래픽 예측 방법)

  • Park, Sang-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1069-1076
    • /
    • 2016
  • Recent development in visual sensor technologies has encouraged various researches on adding imaging capabilities to sensor networks. Video data are bigger than other sensor data, so it is essential to manage the amount of image data efficiently. In this paper, a new method of video traffic estimation is proposed for efficient traffic management of visual sensor networks. In the proposed method, a first order autoregressive model is used for modeling the traffic with the consideration of the characteristics of video traffics acquired from visual sensors, and a Kalman filter algorithm is used to estimate the amount of video traffics. The proposed method is computationally simple, so it is proper to be applied to sensor nodes. It is shown by experimental results that the proposed method is simple but estimate the video traffics exactly by less than 1% of the average.

Difference of total activation depends on stimulation paradigm at motor and visual cortices and cerebellum (운동과 시각 피질, 소뇌에서 자극변화에 따른 총활성화의 차이)

  • Chung, S.C.;Song, I.C.;Chang, K.H.;Yu, B.K.;Mun, C.W.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.289-290
    • /
    • 1998
  • Purpose To investigate the difference of total activation in visual area, motor area, and cerebellum according to the stimulation paradigm. Materials and Methods Functional MR imaging was performed in 5 healthy volunteers with visual and motor activity using EPI technique. LED and Checker-Board stimulation were performed for visual activity. Thumb motion and Finger tapping were performed for motor and cerebellum activity. Time course data was obtained by calculating the total activation which was defined as the number of activated pixels x averaged pixel intensity. Results In the case of visual activity with LED stimulation, we found increased total activity of more than 100% compared with Checker-Board stimulation. In the case of motor area and cerebellum with Finger tapping stimulation, we found increased total activity of more than 100% and 150%, respectively compared with Thumb motion stimulation.

  • PDF

A Case of Pituitary Metastasis from Breast Cancer That Presented as Left Visual Disturbance

  • Kim, Young-Ha;Lee, Beom-Jun;Lee, Kyung-Jin;Cho, Jin-Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.2
    • /
    • pp.94-97
    • /
    • 2012
  • Tumors that metastasize to the pituitary gland are unusual, and are typically seen in elderly patients with diffuse malignant disease. The most common metastases to the pituitary are from primary breast and lung cancers. We report a 65-year-old woman with pituitary metastasis from breast cancer who presented with recent-onset left progressive deterioration of visual acuity and visual field. The clinical diagnosis was made after brain and sellar magnetic resonance imaging showed a large sellar mass compressing the optic chiasm and invading the pituitary stalk. An otorhinolaryngology and neurosurgery team removed the tumor via a transsphenoidal approach, and this procedure obtained symptomatic relief. Postoperatively, metastasis from breast invasive ductal adenocarcinoma was confirmed histologically. We report this unusual case with a review of the relevant literature.

The Analysis of Information Transfer Efficiency in Medical Image Display

  • Kim, Jong-Hyo;Min, Byoung-Goo;Han, Man-Cheong;Lee, Choong-Woong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.55-57
    • /
    • 1992
  • Image display is the last step of imaging chain in which the diagnostic information is transformed into perceivable intensities and transformed to observer's eye-brain system. In this process, a certain part of information may be efficiently transfered and another part may be inefficiently transfered leading to information loss. In this study, the visual perceptual properties of image display on CRT monitor has been investigated. Psychophysical experiment of target image detection has been performed using CRT monitor for various background grey levels, and the threshold difference grey levels required for visual discrimination have been predicted by computer simulation with visual model.

  • PDF