• Title/Summary/Keyword: Visual fixation

Search Result 189, Processing Time 0.022 seconds

Clinical Results of Lateral-Posterior Internal Fixation for the Treatment of Scapular Body Fractures (견갑골 체부 골절에서 외측 후방 금속판 고정술의 치료 결과)

  • Lee, Yoon-Min;Yeo, Joo-Dong;Song, Seok-Whan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.46-53
    • /
    • 2020
  • Purpose: Scapular body fractures have generally been treated with non-surgical methods. This study reports the clinical and radiological outcomes after lateral-posterior internal fixation for treating displaced scapular body fractures. Materials and Methods: From March 2007 to May 2017, out of 40 patients who underwent internal fixation for scapular fractures, 13 cases of lateral plate fixation of a scapular body fracture were reviewed retrospectively. Preoperative and postoperative displacement, angulation and glenopolar angle (GPA) were measured. The range of shoulder motion, visual analogue scale (VAS), and disabilities of the arm, shoulder, and hand (DASH), and Constant score were assessed at the last follow-up. Results: The mean follow-up period was 17.7 months (range, 6-45 months). The mean preoperative GPA was 23.3°±3.96° (range, 17.8°-28.1°) and the postoperative GPA was 31.1°±4.75° (range, 22.5°-40.1°). Injury to the suprascapular nerve, nonunion, fracture redisplacement, metallic failure, or infection did not occur. At the last follow-up, the mean range of motion was 150.5°±19.3° in forward flexion, 146.6°±2.34° in lateral abduction, 66.6°±19.1° in external rotation, and 61.6°±18.9° in internal rotation. The VAS, DASH, and Constant scores were 1.7±1.3, 6.2±2.4, and 86±7.9 points, respectively. Conclusion: A scapular body fracture with severe displacement, angulation and marked decreased GPA can be stabilized by lateralposterior plate fixation using the appropriate surgical technique with good functional and radiological results.

A Comparison between Minimally Invasive Percutaneous Plate Osteosynthesis and Plate Fixation in the Treatment of Clavicle Midshaft Fracture (쇄골 간부 골절의 최소 침습적 경피적 금속판 고정술과 관혈적 수술 비교)

  • Yoo, Seong-Ho;Kang, Suk-Woong;Kim, Bu-Hwan;Song, Moo-Ho;Kim, Yeong-Joon;Park, Gyu-Taek;Kwack, Chang-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Purpose: To retrospectively compare minimally invasive percutaneous plate osteosynthesis (MIPPO) with open plate fixation for the treatment of clavicle midshaft fracture. Materials and Methods: Between November 2011 to May 2014, 40 cases that were followed for more than 1 year-among all cases of MIPPO and open plate fixation-were analyzed. The study population was divided into two groups: group A included 20 cases of MIPPO and group B included 20 open plate fixation cases. The comparative analysis between the two groups was based on the operative time, bone union, functional evaluation (American Shoulder and Elbow Society score), incision length, pain relief (visual analogue scale, VAS), and complication. Results: The bone union was successful for all the cases, and the functional evaluation scores of the shoulder joint were satisfactory for both groups (p>0.05). The operative time was 47.5 minutes and 58.7 minutes for group A and B, respectively (p<0.05). The incision length for group A was 6.2 cm and that for group B was 10.7 cm with statistical significance (p<0.05). Pain relief (VAS) after surgery for group A showed a quick recuperation in the early stages. For complications, there were 2 cases of dysesthesia and 1 case of malunion due to metal fixation failure in group A. There were 6 cases of dysesthesia and 2 cases of cosmetic problem due to hypertrophic scar in group B. Conclusion: Surgical results of clavicle shaft fracture were satisfactory for both groups, but group A had advantages of shorter operative time, minimal incision length, and better pain relief in the early stages compared with group B. However, we need further evaluations with long-term follow-up results and complications, such as malunion and exposure on radiation.

Aided Distance Visual Acuity and Refractive Error Changes by Using Smartphone (스마트폰 사용이 원거리 교정시력과 굴절 이상 변화에 미치는 영향)

  • Kim, Bong-Hwan;Han, Sun-Hee;Shin, Young Gul;Kim, Da Yeong;Park, Jin Young;Sin, Won Chul;Yoon, Jeong Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.305-309
    • /
    • 2012
  • Purpose:This study was conducted to research any effect on aided distance visual acuity and refractive error changes by using smartphone at near for long term. Methods: 20($20.6{\pm}0.9$ years) young adults subjects with no ocular diseases, over 0.8 of aided distance visual acuity, normal amplitude of accommodation and normal accommodative facility agreed to participate in this study. The subjects were divided into two group, Group 1 (15 cm fixation distance) included 10 subjects and Group 2(40 cm fixation distance) included 10 subjects. Aided distance visual acuity and refractive error were measured before and after using smartphone for 30 minutes by auto-chart project (CP-1000, Dongyang, Korea), phoropter (VT-20, Dongyang, Korea), auto refractor-keratometer (MRK-3100, Huvitz, Korea). After then, the subjects looked at distance with wearing spectacles. Refractive error was measured at 5 minutes, 10 minutes, and 15 minutes later, respectively. Results: After using smartphone at 15 cm for 30 minutes, there was statistically significant reduction of aided distance visual acuity (p=0.030) and increasing myopia (p=0.001). The increased myopia was not statistically significant after 5 minutes rest (p${\geq}$0.464). However there was no statistically significant changes in aided distance visual acuity (p=0.163) and refractive error (p=0.077) after using smartphone at 40 cm for 30 minutes. Conclusions: It is recommend to keep 40 cm off the smartphone from eyes to avoid any aided distance visual acuity and refractive error changes. If smartphone is used closer than 40 cm, a rest for 5 minutes is also recommend after every 30 minutes use with smartphone to avoid any aided distance visual acuity and refractive error changes.

A Study on the Property of Visual Perception of Interior Space - By revising the observation time of the design element - (실내공간의 주시특성에 관한 연구 - 전회공간의 주시시간 보정을 통해 -)

  • Choi, Gae-Young;Kim, Jong-Ha;Lee, Jeong-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.128-136
    • /
    • 2009
  • This study analyzed and defines the property of visual perception throughout the revision of the observation time of the original space and the rotating space. The conclusions of this study are as fellows: First, based on the existing theory and experiment, the study obtained the basis which decides the sector data originating fixation-gaze after staring the specific sector over 300ms time. It will become the turning point hereafter for our research to fix the time in this way. Second, in analyzing the minute data, the study built a revision method of the observation time by analyzing the meanings and the reasons of the revision of the original data. Third, according to the difference of revision quantity, female testee have more increases in the amount of data than male testee from the original screen. On the other hand, the opposite tendency appears from the previous data. This shows there is a difference in the observation properly by sex. Last, we could grasp Information about the property of the observation time throughout eyeball fixations, and the revision and analysis of the 'controlled observation data'. These data can be used in design element arrangement of interior space, hereafter.

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

A COMPARATIVE STUDY ON POST-OPERATIVE ANALGESIC EFFECT FOR PATIENT-CONTROLLED AND INTRAMUSCULAR ANALGESIA IN MANDIBULAR FRACTURE PATIENTS (하악골 골절환자에서 술후 자가통증조절장치와 근주용 진통제의 효과에 관한 비교)

  • Lee, Seok-Jae;Kim, Kyung-Wook;Kim, Chul-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.1
    • /
    • pp.42-48
    • /
    • 2006
  • Open reduction and rigid internal fixation is the most popular treatment method for maxillofacial fracture patients, and it is unevitable that postoperative pain can be developed. Many surgeons including oral & maxillofacial surgeons have made constant efforts to decrease postoperative pain. This study is a comparison of postoperative analgesia and intramuscular analgesia in patients with mandibular fractures. In this study, twenty-one patients (Experimental group) were randomly selected and they were injected with IV patient-controlled analgesia (PCA; Walkmed$^{(R)}$, USA). For control group another twenty-one patients were injected with intramusclar non-steroid anti-inflammatory drugs (Rheoma$^{(R)}$, Samsung Pharm. Co.). And then, we measured visual analogue scale (VAS) scores from first postoperative day to second day at regular time interval. The following results were uptained; 1. In patient group who with open reduction and rigid internal fixation, there was significant difference of postoperative analgesic effect during the first postoperative day(p<0.05). 2. In patient group with over 90 minutes surgery time, there was significant difference of postoperative analgesic effect during the first and second postoperative day when compared between experimental group and control group(p<0.05). 3. In patient group with less than 90 minutes surgery time, there was no significant difference of postoperative analgesic effect during the first and second postoperative day when compared between experimental group and control group(p>0.05). 4. In patient group with surgery of open reduction using rigid internal fixation at single fractured site, there was no significant difference of postoperative analgesic effect during the first and second postoperative day when compared between experimental group and control group(p>0.05). 5. In patient group with surgery at two fractured sites, there was significant difference of postoperative analgesic effect during the first postoperative day when compared between experimental group and control group(p<0.05). As mentioned above, it suggest that patient-controlled analgesia is more effective for postoperative pain relief than intramuscular injection in patients with rigid internal fixation by open reduction after mandibular fracture occurred. Especially, it is considered that in patient with more than 90 minutes surgery time or in cases with multiple fractured sites had more effective results with PCA therapy than conventional intramuscular analgesics.

A Study on Reconciliation of Observation Data of Interior Space and Feasibility of its Analysis Process (실내공간 주시 데이터의 보정과 분석과정 타당성에 관한 연구)

  • Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.135-142
    • /
    • 2011
  • There occurs subtle shaking in our eyes while in looking at objects and this study sets up the standard of reconciliation from the property of observation and organizes the property of data reconciliation by the observation range to secure the feasibility of reconciliation range and method of the original data obtained from observation experiment and its analysis process. The results from above study can be concluded as in the followings: First, it made clear the process to exclude eye blink and data out of image range from the original data so to set up the range of available data. Second, on the basis of existing theory, it was possible to define the minimum attention time as 0.1 second (3 times of observation) and the visual understanding time of space as 0.3 second (9 times of observation) in the study on the property of observation, and this definition of observation time of sight fixation becomes an important indicator in the analysis of observation data. Third, based on the observation theory of continuity securing and attention, it was able to arrange the standard of reconciliation by carrying out reconciliation works only when fixed data with more than three times of observation showed consecutively before and behind the data with intermittent movements. Fourth, In the sector whether visual understanding occurred (more than 9 times), it increased by 12% for the frequency of observation and by 7.8% for the times of observation compared with the ones before the reconciliation. These results showed to have a constant change by subjects so that it was able to arrange a foundation to secure objective data in the analysis of the observation range and its extent.

Web Usability Testing by Using Scanpath Similarity Analysis (탐색경로 일치도 분석을 이용한 웹사이트 사용성 평가)

  • Kim, Youngjun;Kim, Youngjin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.793-803
    • /
    • 2013
  • This study was performed to determine the usefulness of scanpath similarity analysis as one of new web usability testing. The 5 websites of public institutions were used and 15 students participated. First of all, eye movements were tracked and visual appeal ratings were measured as participants freely viewed each website for 3 seconds. Subsequently in continuously tracking the eye movements we asked the participants to perform 17 missions. Finally, in interview the participants rated on satisfaction, awareness, and mission difficulty. Results of this study showed that scanpath similarity had a significant relationship with both the visual appeal ratings(first impression) and the satisfaction. In other words, higher the visual appeal ratings were related to higher scanpath similarity. This result showed that measurement such as scanpath similarity of eye movements could become an objective index for usability testing instead of subjective evaluation such as the satisfaction. We discussed possibility that the usability testing by using the scanpath similarity with both fixation and duration on eye movements will find more appropriately inference on observers' experiences in websites.

Study of Eye-Fixation Analysis Method for Convergence Point Adjustment (컨버전스 포인트 조정을 위한 주시특성 분석방법에 관한 연구)

  • Ha, JongSoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.426-429
    • /
    • 2015
  • 입체카메라에서 줌 사용시 컨버전스 포인트의 움직임에 따라 발생되는 시각적 불편의 문제와 거리감의 변동을 해결하기 위해 컨버전스 포인트 조정기법을 제시했었다. 본 연구에서는 이러한 조정기법의 우수성을 입증하기 위해 정량적 평가인 주시특성 분석을 설계했다. 입체영상에 대한 주관평가를 사용자의 시선움직임을 통해 정량적으로 파악하게 된다면 입체에 대한 사용자의 감성이미지를 보다 정확하게 파악할 수 있으며 이러한 자료를 통해 사용자 중심의 입체영상을 제작할 수 있는 환경을 제공하는 것이 가능할 것이다. 이를 통해 제시된 기법의 우수성을 정성과 정량적으로 입증한다.

  • PDF

Application of Monitored Anesthesia Care Using Dexmedetomidine to Common Oral and Maxillofacial Trauma Cases

  • Lee, Deok-Won;Shin, Min Cheol;Hong, Sung ok
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.82-86
    • /
    • 2017
  • Oral and maxillofacial surgery (OMFS) trauma cases are commonly treated under general anesthesia. The purpose of this case report is to introduce an alternative method of anesthesia in patients who refuse general anesthesia. A combination of dexmedetomidine and ketamine for sedation anesthesia in 3 frequent fracture types in the field of OMFS-Le Fort I fracture, mandibular fracture, and alveolar bone fracture-was used. Dexmedetomidine as the single agent has not shown stable success rates for invasive procedures. To overcome some of the pitfalls with dexmedetomidine, combination sedation using ketamine was performed. Visual analogue scale scores were recorded postoperatively. Dexmedetomidine combined with ketamine administration provided safe and effective sedation and anxiolysis for surgical reduction and internal fixation of OMFS fractures. It showed advantages of decreased admission time, reduced expenses, minimal pain, and reduced anesthetic burden for the patient thus ultimately increasing overall satisfaction.