• Title/Summary/Keyword: Visual Field Testing

Search Result 49, Processing Time 0.025 seconds

The Effect of Gaze Fixation Induction Method on Visual Field Testing (시선 고정 유도방법이 시야 검사에 미치는 영향)

  • Lee, Jihyung;Choi, Younggeun;Yang, Xiaopeng;Lee, Nahyun;Oh, Gunhee;Kim, Young Gyun;Kang, Jaheon;You, Heecheon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.42 no.6
    • /
    • pp.412-420
    • /
    • 2016
  • A visual field tester using a fixation target with a lack of distinctiveness decreases accuracy and usability in visual field testing. The present study is intended to develop various induction methods of gaze fixation for effective visual field testing. Proposed were four new gaze fixation induction methods (color changing dot; alphanumeric characters; flashing black dot; and bulls eye and cross hair, BECH) by considering visual attention factors such as color, meaning, flashing, and shape and the proposed methods were compared with the existing black dot (BD) method in terms of gaze fixation performance and subjective satisfaction by 32 participants in their 20s to 30s. BECH was found most preferred by increasing gaze fixation performance by 4.8% and subjective satisfaction by 0.4 to 2.0 in a 7-point scale compared to BD. BECH can be applied to tests such as visual field testing and macular pigment optical density testing in which gaze fixation is crucial for accuracy and usability.

Implementation of dynamic visual acuity testing system using optical see through head mounted display

  • Son, Hojun;Yun, Deokyoung;Kim, Jungho;Lee, Seunghyun;Kwon, Soonchul
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.3
    • /
    • pp.70-77
    • /
    • 2017
  • Dynamic visual acuity is used as an important factor to measure athletic performance in sports field. A study on visual acuity testing system using non-see head mounted display (NST-HMD) was conducted recently. However, the NST-HMD has a problem that the sense of space felt by the subject differs from the actual environment. This is because the view is blocked so that it is only implemented in a virtual space. This paper proposes a dynamic visual acuity testing system using optical see through head mounted display (OST-HMD). To do this, OST-HMD and NST-HMD comparative tests were conducted using existing K-D (King-Devick) charts. Experiments were performed on 30 subjects and their visual acuity was measured and analyzed by parametric statistics and one-sample T-test. The results of the study demonstrate the effectiveness of the proposed OST-HMD. This study is expected to use the visual inspection and training equipment of OST-HMD.

Modified Trans-Middle Temporal Gyrus Approach for Trigonal Tumor to Preserve Visual Field

  • Choi, Jeong-Wook;Jung, Shin;Jung, Tae-Young;Jang, Woo-Youl;Moon, Kyung-Sub;Kim, In-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.6
    • /
    • pp.538-541
    • /
    • 2011
  • Objective : We evaluated a modified trans-middle temporal gyrus (MTG) approach with good postoperative visual preservation for patients with trigonal tumors. Methods : Three patients with a trigonal tumor were treated via the modified trans-MTG approach guided by a neuro-navigator. Modified trans-MTG approach involve the incision at the MTG within 5 mm to the superior temporal sulcus. This approach makes a proper trajectory to the trigone but also reduces the retraction injury of MTG as little as possible to prevent postoperative visual field defect. Preoperative and postoperative visual field examination using perimetry was performed to evaluate the visual field. Results : Three patients underwent surgery for lymphoma in the right trigone, meningioma in the left trigone, and focal enhancing nodule in the right paratrigonal area, respectively. In case of lymphoma, preoperative examination showed a left homonymous hemianopsia : one week later after surgery, a visual field examination was performed and revealed improvement of the visual field defect. In case of the meningioma, the preoperative examination showed no visual field defect : one month later, the visual field had no defect. In case of the enhancing nodule, preoperative visual field testing revealed a partial left homonymous hemianopsia. Visual examination within one month after surgery showed no visual field defect. All three patients treated with the modified trans-MTG approach showed no visual deterioration after surgery. Conclusion : The modified trans-MTG approach provides a safe and useful technique for trigonal tumors without postoperative visual field deterioration and affords adequate exposure of the trigonal tumor with a short trajectory.

Structural Performance of an Advanced Compsites Bridge Superstructure for Rapid Installation (급속시공용 복합신소재 교량상부구조의 구조 성능)

  • Ji, Hyo-Seon
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.1
    • /
    • pp.34-45
    • /
    • 2010
  • This paper describes the design, manufacturing process, testing, application, and assessment of capacity-ratings of the first all advanced composites bridge on a public highway system. In order to verify the bridge design prior to the field application, a sub-scale bridge superstructure was built and tested in the laboratory. The field load test results were compared with those of the finite element analysis for the verification of validity. To investigate its in-service performance, field load testing and visual inspections were conducted under an actual service environment. The paper includes the presentation and discussion for advanced composites bridge capacity rating based on the stress modification coefficients obtained from the test results. The test result indicates that the advanced composites bridge has no structural problems and is structurally performing well in-service as expected. Since these composite materials are new to bridge applications, reliable data is not available for their in-service performance. The results may provide a baseline data for future field advanced composites bridge capacity rating assessments and also serve as part of a long-term performance of advanced composites bridge.

  • PDF

Experience in Visual Testing of the Main Feed Water Piping Weld for Hanul Unit 3 (한울 3호기 주급수 배관 용접부 육안검사 경험)

  • Yoon, Byung Sik;Moon, Gyoon Young;Kim, Yong Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.74-78
    • /
    • 2015
  • Nuclear power plant steam generator that is one of the main component has several thousands of thin tubes. And the steam generator tube is subject to damage because of the severe operation conditions such as the high temperature and pressure. Therefore periodic inspections are conducted to ensure the integrity of steam generator component. Hanul unit 3 also has been inspected in accordance with in-service inspection program and is scheduled to be replaced for exceeding the plugging rate which was recommended by manufacturer. During the steam generator replacement activity, we found several clustered porosity on inner surface of main feed water pipe. Additionally crack-like indications were found at weld interface between base material and weld of main feed water pipe. This paper describes the field experience and visual testing results for inner surface of main feed water pipes. The destructive test result had shown that these indications were porosities which were caused by manufacturing process not by operation service.

A Large Ruptured Anterior Communicating Artery Aneurysm Presenting with Bitemporal Hemianopsia

  • Seung, Won-Bae;Kim, Dae-Yong;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.291-293
    • /
    • 2015
  • Anterior communicating artery (ACoA) aneurysms sometimes present with visual symptoms when they rupture or directly compress the optic nerve. Giant or large ACoA aneurysms producing bitemporal hemianopsia are extremely rare. Here we present an unusual case of bitemporal hemianopsia caused by a large intracranial aneurysm of the ACoA. A 41-year-old woman was admitted to our neurosurgical department with a sudden-onset bursting headache and visual impairment. On admission, her vision was decreased to finger counting at 30 cm in the left eye and 50 cm in the right eye, and a severe bitemporal hemianopsia was demonstrated on visual field testing. A brain computed tomography scan revealed a subarachnoid hemorrhage at the basal cistern, and conventional cerebral catheter angiography of the left internal carotid artery demonstrated an $18{\times}8mm$ dumbbell-shaped aneurysm at the ACoA. Microscopic aneurysmal clipping was performed. An ACoA aneurysm can produce visual field defects by compressing the optic chiasm or nerves. We emphasize that it is important to diagnose an aneurysm through cerebrovascular study to prevent confusing it with pituitary apoplexy.

Compact near-eye display for firefighter's self-contained breathing apparatus

  • Ungyeon Yang
    • ETRI Journal
    • /
    • v.45 no.6
    • /
    • pp.1046-1055
    • /
    • 2023
  • We introduce a display for virtual-reality (VR) fire training. Firefighters prefer to wear and operate a real breathing apparatus while experiencing full visual immersion in a VR fire space. Thus, we used a thin head-mounted display (HMD) with a light field and folded optical system, aiming to both minimize the volume for integration in front of the face into a breathing apparatus and maintain adequate visibility, including a wide viewing angle and resolution similar to that of commercial displays. We developed the optical system testing modules and prototypes of the integrated breathing apparatus. Through iterative testing, the thickness of the output optical module in front of the eyes was reduced from 50 mm to 60 mm to less than 20 mm while maintaining a viewing angle of 103°. In addition, the resolution and image quality degradation of the light field in the display was mitigated. Hence, we obtained a display with a structure consistent with the needs of firefighters in the field. In future work, we will conduct user evaluation regarding fire scene reproducibility by combining immersive VR fire training and real firefighting equipment.

An Analysis of Visual Fatigue Caused From Distortions in 3D Video Production (3D 영상의 제작 왜곡이 시청 피로도에 미치는 영향 분석)

  • Jang, Hyung-Jun;Kim, Yong-Goo
    • Journal of Broadcast Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-16
    • /
    • 2012
  • In order to improve the workflow of 3D video production, this paper analyzes the visual fatigue caused from distortions in 3D video production stage through a set of subjective visual assessment tests. To establish a set of objective indicators for subjective visual tests, various distortions in production stage are investigated to be categorized into 7 representative visual-fatigue-producing factors, and to conduct visual assessment tests for each selected category, 4 test video clips are produced by combining the extent of camera movement as well as the object(s) movement in the scene. Each produced test video is distorted to reflect each of the selected 7 visual-fatigue-producing factors, and we set 7 levels of distortion for each factor, resulting in 196 5-second-long video clips for testing. Based on these test materials and the recommendation of ITU-R BT.1438, subjective visual assessment tests are conducted by 101 applicants. The test results provide a relative importance and the tolerance limit of each visual-fatigue-producing factor, which corresponds to various distortions in 3D video production field.

Noncontact techniques for monitoring of tunnel linings

  • White, Joshua;Hurlebaus, Stefan;Shokouhi, Parisa;Wittwer, Andreas;Wimsatt, Andrew
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.2
    • /
    • pp.197-211
    • /
    • 2014
  • An investigation of tunnel linings is performed at two tunnels in the US using complimentary noncontact techniques: air-coupled ground penetrating radar (GPR), and a vehicle-mounted scanning system (SPACETEC) that combines laser, visual, and infrared thermography scanning methods. This paper shows that a combination of such techniques can maximize inspection coverage in a comprehensive and efficient manner. Since ground-truth is typically not available in public tunnel field evaluations, the noncontact techniques used are compared with two reliable in-depth contact nondestructive testing methods: ground-coupled GPR and ultrasonic tomography. The noncontact techniques are used to identify and locate the reinforcement mesh, structural steel ribs, internal layer interfaces, shallow delamination, and tile debonding. It is shown that this combination of methods can be used synergistically to provide tunnel owners with a comprehensive and efficient approach for monitoring tunnel lining conditions.

Calibration of Detection System of Crack in Concrete Structure by Using Image Processing Technology

  • Kim, Su-Un;Shin, Sung-Woo;Park, Jeong-Hak;Choi, Man-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.6
    • /
    • pp.626-634
    • /
    • 2011
  • The investigation of concrete structure typically relies on visual inspection which is one of the basic inspection techniques. Image processing techniques play a crucial role in the growing field of automatic surface inspection technique. However, kinds of inspection equipment, environmental condition and detection algorithm have much influence on the reliability of inspection result. This paper proposes a verification method and testing procedure for the reliability of inspection results and surveys characteristics of image acquisition systems and crack inspection algorithms.