• Title/Summary/Keyword: Visual Distance

Search Result 736, Processing Time 0.033 seconds

Building a Robust 3D Statistical Shape Model of the Mandible (견고한 3차원 하악골 통계 형상 모델 생성)

  • Yoo, Ji-Hyun;Hong, Helen
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.2
    • /
    • pp.118-127
    • /
    • 2008
  • In this paper, we propose a method for construction of robust 3D statistical shape model in the mandible CT datasets. Our method consists of following four steps. First, we decompose a 3D input shape Into patches. Second, to generate a corresponding shape of a floating shape, all shapes in the training set are parameterized onto a disk similar to the patch topology. Third, we generate the corresponding shape by one-to-one mapping between the reference and the floating shapes. We solve the problem failed to generate the corresponding points near the patch boundary Finally, the corresponding shapes are aligned with the reference shape. Then statistical shape model is generated by principle component analysis. To evaluate the accuracy of our 3D statistical shape model of the mandible, we perform visual inspection and similarity measure using average distance difference between the floating and the corresponding shapes. In addition, we measure the compactness of statistical shape model using the modes of variation. Experimental results show that our 3D statistical shape model generated by the mandible CT datasets with various characteristics has a high similarity between the floating and corresponding shapes and is represented by the small number of modes.

Automation of Bio-Industrial Process Via Tele-Task Command(I) -identification and 3D coordinate extraction of object- (원격작업 지시를 이용한 생물산업공정의 생력화 (I) -대상체 인식 및 3차원 좌표 추출-)

  • Kim, S. C.;Choi, D. Y.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2001
  • Major deficiencies of current automation scheme including various robots for bioproduction include the lack of task adaptability and real time processing, low job performance for diverse tasks, and the lack of robustness of take results, high system cost, failure of the credit from the operator, and so on. This paper proposed a scheme that could solve the current limitation of task abilities of conventional computer controlled automatic system. The proposed scheme is the man-machine hybrid automation via tele-operation which can handle various bioproduction processes. And it was classified into two categories. One category was the efficient task sharing between operator and CCM(computer controlled machine). The other was the efficient interface between operator and CCM. To realize the proposed concept, task of the object identification and extraction of 3D coordinate of an object was selected. 3D coordinate information was obtained from camera calibration using camera as a measurement device. Two stereo images were obtained by moving a camera certain distance in horizontal direction normal to focal axis and by acquiring two images at different locations. Transformation matrix for camera calibration was obtained via least square error approach using specified 6 known pairs of data points in 2D image and 3D world space. 3D world coordinate was obtained from two sets of image pixel coordinates of both camera images with calibrated transformation matrix. As an interface system between operator and CCM, a touch pad screen mounted on the monitor and remotely captured imaging system were used. Object indication was done by the operator’s finger touch to the captured image using the touch pad screen. A certain size of local image processing area was specified after the touch was made. And image processing was performed with the specified local area to extract desired features of the object. An MS Windows based interface software was developed using Visual C++6.0. The software was developed with four modules such as remote image acquisiton module, task command module, local image processing module and 3D coordinate extraction module. Proposed scheme shoed the feasibility of real time processing, robust and precise object identification, and adaptability of various job and environments though selected sample tasks.

  • PDF

Comparison of high molecular coating type dentine hypersensitivity desensitizers (고분자 기반 코팅형 상아질 지각 과민 처치제의 효과에 대한 비교 연구)

  • Roh, Young-Hoon;Lee, Joo-Yeon;Park, Hyun-Jung;Choi, Cha-Nam;Park, Yoon-Jeong;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung
    • The Journal of the Korean dental association
    • /
    • v.46 no.11
    • /
    • pp.683-688
    • /
    • 2008
  • Purpose : The aim of this study was to evaluate the clinical efficacy of two commercially available desensitizing agents over 3 weeks on patients with dentin hypersensitivity. Materials and Methods : An oxalate-based solution, Sensblok (NIBEC Inc. Seoul, Korea) & Superseal (Pheonix Inc. Michigan, USA), and a distilled water placebo were compared in a clinical setting. Seven volunteers exhibiting three or more teeth that were sensitive to tactile & air were enrolled in the study (35 teeth total). A visual analog scale (VAS) was used for recording each patient s level of sensitivity to tactile & air stimuli. A Florida probe was rubbed across the exposed dentin three times with a constant pressure 20 grams to measure the tactile stimulus. The air stimulus was generated by dental unit air syringe for 1-second blast from 1/2 inch distance. The desensitizing agents were applied according manufacture s guideline. VAS scores were recorded at baseline, 1 minute after treatment, at 1 week, 2weeks, 3weeks. VAS score were analyzed using a repeated measures ANOVA ( =0.05). Results : The Sensblok, Superseal, and distilled water placebo all decreased dentin sensitivity. A statistically significant difference existed between Sensblok and placebo when tactile stimulus was applied (P<0.05), but no significant difference was found among other desensitizing agents and tactile and air stimuli.

  • PDF

Efficacy and Safety of Geochangmanryeung-dan and Acupuncture on Patient with Spinal Stenosis Treated by Epidural Steroid Injection: a Study Protocol for a Randomized Controlled Pilot Trial (경막외신경차단술로 치료 중인 척추관 협착증 환자에서 거창만령단과 침의 효능 및 안전성 연구(예비임상연구))

  • Lee, Hyun-jong;Lee, Cho In;Lee, Saram;Kwak, Min-Ah;Kwak, Sang Gyu;Roh, Woon-seok;Jung, Jin-yong
    • Korean Journal of Acupuncture
    • /
    • v.32 no.3
    • /
    • pp.99-107
    • /
    • 2015
  • Objectives : This study was designed to obtain basic data for a further large-scale trial as evaluating the efficacy and safety of Geochangmanryeung-dan(GMD) and acupuncture on patient with spinal stenosis treated by epidural steroid injection. Methods: The study is a randomized controlled pilot clinical trial, conducted over 8 weeks. Twenty participants will be recruited and randomly allocated to 2 groups: an experimental(GMD and acupuncture with epidural steroid injection) group and a control(only epidural steroid injection) group. The epidural steroid injection will be administered once per 2 weeks for 6 weeks(3 times in total). GMD will be administered as a dose of 5 pills, 3 times per day, for 6 weeks. Acupuncture will be performed 2 times per week for 6 weeks(12 times in total). The primary outcome will be measured by visual analogue scale and self-rated walking distance. The secondary outcome will be measured by PainVision, short-form McGill Pain Questionnaire, and Oswestry Disability Index. Both primary and secondary outcomes will be measured at baseline, 2, 4, 6, and 8 weeks. The last assessment(at 8 weeks) will be performed 2 weeks after treatment cessation. Conclusions : This clinical trial, as the pilot study for a future large-scale trial, will provide clinical information for evaluating the efficacy and safety of GMD and acupuncture treatment in combination with epidural steroid injection for the treatment of spinal stenosis.

Development of 3X Scope with Objective Configured with Doublet+Meniscus Lens (더블렛+메니스커스렌즈 대물부를 가지는 3X 스코프 개발)

  • Lee, Dong-Hee;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.487-492
    • /
    • 2014
  • Purpose: This study relates to the development of the 3X scope, whose objective part is configured with a doublet + a meniscus lens. Methods: By the initial condition of the objective part having a configuration of a doublet + a singlet, we could optimize the optical system of scope in order to minimize the finite ray aberrations of the objective part and the whole optical system of scope, and so we could develope a new type 3X scope. Results: On the condition of the objective part having a configuration of a doublet + a singlet, when the optical system of scope was optimized in order to minimize the finite ray aberrations, we could find that the singlet became the meniscus type lens having the concave shape to the direction of the doublet, and the longer the distance between the doublet and the meniscus lens is, the more the finite ray aberrations are minimized. Conclusions: In this study, we could develope a new type 3X scope of which finite ray aberrations can be reduced to 1/14 than the existing scope by adopting the objective part of the 3X scope having a configuration of three lenses composed of a doublet + a singlet. We could confirm that this reduction of aberrations can be a means to increase the effective aperture than the existing scope and to shorten the length of the optical system.

The Effects of Lumbar Sympathetic Ganglion Block in the Patients with Spinal Stenosis and the Skin Temperature Changes according to the Contrast Spread Patterns (요척주관 협착증 환자의 요부 교감신경 차단술의 효과 및 조영 양상에 따른 피부 체온의 변화)

  • Hong, Ji Hee;Kim, Jin Mo;Kim, Ae Ra;Lee, Yong Chul;Kim, Sae Young;Kwon, Seung Ho;Oh, Min Ju
    • The Korean Journal of Pain
    • /
    • v.22 no.2
    • /
    • pp.151-157
    • /
    • 2009
  • Background: We hypothesized that if a fluoroscopic image of the lumbar sympathetic ganglion block (LSGB) showed the spread patterns of contrast at both the L2/3 and L4/5 disc areas, then this would demonstrate a more profound blockade effect because the spread patterns are close to sympathetic ganglia. In addition, we compared the effects of LSGB and transforaminal epidural steroid injection (TFESI) for the patients suffering with spinal stenosis. Methods: Eighty patients were divided into two groups (Group S: the patients treated with TFESI, Group L: the patients treated with LSGB). The patients of group L were classified into three groups (groups A, B and, C) according to their contrast spread pattern. The preblock and postblock temperature difference between the ipsilateral and contralateral great toe ($DT^{pre}$, $DT^{post}$, $^{\circ}C$), and the DTnet were calculated as follows. $DT^{net}$ = $DT^{post}$ - $DT^{pre}$. Results: Both group showed a significant reduction of the visual analogue score (VAS) and the Oswestry disability index (ODI) score. Only the patients of group L showed a significant increase of their walking distance (WD). Group A showed the most significant changes in the $DT^{post}$ ($6.1{\pm}1.2^{\circ}C$, P = 0.021), and the DTnet ($6.0{\pm}1.0^{\circ}C$, p = 0.023), as compared to group C. Conclusions: LSGB showed a similar effect on the VAS, and ODI, and a significant effect, on WD, compared with TFESI. Group A showed a significant sympatholytic effect, as compared to group C.

Subjective Evaluation about Ideal Position of the Subnasale on Lateral Photos (측모 사진상에서 Subnasale의 이상적인 위치에 관한 주관적 평가)

  • Kim, Yi-Dong;Chung, Dong-Hwa;Cha, Kyung-Suk;Lee, Jin-Woo;Lee, Sang-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.347-358
    • /
    • 2013
  • When analyzing soft tissue of the profile, Subnasale is often used as an important reference point. But there are few studies on the ideal position of the Subnasale. Therefore, the purpose of this study is to present an objective reference of the esthetic face relating to the change of Subnasale position in Koreans' profile, and also to determine whether there is concordance between professionals and laypersons in their perception of facial attractiveness. The one determined as appropriate profile portion by experts of pictures taken in women in 20s was selected. The photograph was modified changing the Subnasale anteroposteriorly on the plane perpendicular to the true vertical line, while maintaining the nasolabial angle. The photographs were presented to a group of professionals (9 orthodontists) and 126 laypersons, who were asked to assess the facial attractiveness of the photographs on a VAS independently. The conclusion was obtained. 1. The ideal position of the Subnasale is when the ratio of the distance Lateral canthus~Subnasale : Subnasale~Pronasale is 1.769 : 1. 2. The ideal degrees between the true vertical line passing through Nasion and Subnasale is $5.5^{\circ}$ 3. The professionals recognized every change in the ratio, but the laypersons couldn't differentiate between the change from 1.571 : 1 to 1.769 : 1.

The Study on the Property of The Heterophoria and Fusional Reserve in Adults in Jeon-buk Area (전북지역 성인의 사위와 융합여력 특성에 관한 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Sim, Sang-Hyun;Choi, Sun Mi;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.661-666
    • /
    • 2013
  • The aim of this study was to evaluate the property of heterophoria and fusional reserve in Adults in Jeon-buk Area. We examined the corrected visual acuity, corrected refractive error, heterophoria and fusional reserve of 116 healthy myopes aged from 20 to 44 old who had no strabismus no ocular and phyisical diseases. Using Von Graefe test of horizontal heterophoria Measurement, we measured orthophoria(26.7%), exophoria(52.5%) and esophoria(20.7%) for at near distance. The subjects who had exophoria of 0-6${\Delta}$ in the range of normal state was 38.8%, while the subjects who had exophoria in the range of abnormal state was 61.2%. Reducing fusional reserve was associated with increasing phoria. We found a relationship between asthenopia and fusional reserve of heterophoria and considered that fusional reserve must be examined when we preserve for a patient with heterophoria. Furthermore, Gradient method AC/A ratio was found 4.03 and its relationship to refractive error could not be determined.

Experimental Observation of Instability of Supersonic Submerged Jets (수중초음속제트의 불안정성에 대한 실험적 고찰)

  • 정재권;이대훈;차홍석;박승오;권세진
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.45-52
    • /
    • 2002
  • An experimental investigation on the structure and dynamic behavior of two dimensional over-expanded air jets exiting into water was carried out. The hish speed digital video imaging and static pressure distribution measurement were made to characterize the structure and time-dependant behavior of the jets. Mach number at the jet exit was 2.0 and was slightly less than the value predicted by the ideal nozzle calculation. Variance of jet spreading angle at different stagnation condition was measured as a function of mass flow rate. Periodic nature of the air jet distortion in water was observed and the frequency of the repetition was approximately 5-6 Hz for all cases tested. Three characteristic length scales were defined to characterize jet structure. $L_1$, maximum width of the plume when the periodic instability occurs, $L_2$, width of the jet where secondary reverse flow entrained jet flow and $L_3$, distance from the jet exit to the location where entrainment of the secondary reverse flow occurs. The ratio of $L_1$ and $L_2$ decreased with increasing stagnation pressure, i.e. mass flow rate. $L_3$ increased with increasing stagnation pressure. The temporal behavior of static pressure measurements also showed peak around frequency of 5, which corresponds the frequency obtained by visual measurements

An Investigation on the Effects of Wet Cupping on Wisu (BL21) for Non-acute Low Back Pain: A Pilot Randomized Controlled Trial (비급성 요통에 대한 위수혈 자락관법의 효과 탐색: 예비 무작위 대조군 시험)

  • Kim, Hyungsuk;Cho, Jae-Heung;Kim, Koh-Woon;Chung, Won-Seok;Park, Jae-Hyun;Shin, Woo-Chul;Chung, Seok-Hee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.4
    • /
    • pp.21-32
    • /
    • 2018
  • Objectives This study was designed to investigate the effects of wet cupping on Wisu (BL12) in non-acute low back pain patients. Methods We recruited 30 participants for this study. Fifteen patients were randomly assigned to the Wisu (BL21) treatment group (WT group) and 15 were assigned to the non-acupoint treatment group (NT group). Both groups were treated with the pricking-cupping bloodletting method three times. Values at baseline and follow-up were analyzed by Wilcoxon signed rank test and the differences between the two groups were determined by Wilcoxon rank sum test. p-values less than 0.05 were considered significant. The primary outcome was the visual analogue scale (VAS), and secondary outcomes were the Oswestry disability index (ODI), Rolland-Morris disability questionnaire (RMDQ), Euroqol-5 dimension questionnaire (EQ-5D) and finger-to-ground distance (FTGD). These outcomes were measured on the day of first treatment before the procedure and on follow-up 7 days after the last treatment. Results Significant changes were identified in the VAS for pain and ODI in each group after wet cupping treatment on Wisu (p<0.05). However, no significant changes were found between groups. Meanwhile, RMDQ and EQ-5D were significantly decreased only in the NT group (p<0.05) without any differences between groups. FTGD was decreased in both groups, but not significantly. Conclusions Wet cupping with both Wisu treatment and non-acupoint had significant effects on non-acute low back pain, although there were no differences between the two groups. A large-scale study is needed to identify the effect of wet cupping on Wisu.