• 제목/요약/키워드: Visual Axis

검색결과 215건 처리시간 0.024초

Predicting Powers of Spherical Rigid Gas-permeable Lenses Prescription (구면 RGP 렌즈의 처방 굴절력 예측)

  • Yu, Dong-Sik;Yoo, Jong-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제15권3호
    • /
    • pp.219-225
    • /
    • 2010
  • Purpose: Usefulness in predicting the power of spherical rigid gas-pearmeable (RGP) lenses prescription using dioptric power matrices and arithmetic calculations was evaluated in this study. Noncycloplegic refractive errors and over-refractions were performed on 110 eyes of 55 subjects (36 males and 19 females, aged $24.60{\pm}1.55$years) in twenties objectively with an auto-refractometer (with keratometer) and subjectively. Tear lenses were calculated from keratometric readings and base curves of RGP lenses, and the power of RGP lenses were computed by a dioptric power matrix and an arithmetic calculation from the manifest refraction and the tear lens, and were compared with those by over-refractions in terms of spherical (Sph), spherical quivalent (SE) and astigmatic power. Results: The mean difference (MD) and 95% limits of agreement (LOA=$MD{\pm}1.96SD$) were better for SE (0.26D, $0.26{\pm}0.70D$) than for Sph (0.61D, $0.61{\pm}0.86D$). The mean difference and agreement of the cylindrical power between matrix and arithmetic calculation (-0.13D, $-0.13{\pm}0.53D$) were better than between the others (-0.24D, $0.24{\pm}0.84D$ between matrix and over-refraction; -0.12D, $0.12{\pm}1.00D$ between arithmetic calculation and over-refraction). The fitness of spherical RGP lenses were 54.5% for matrix, 66.4% for arithmetic calculation and 91.8% for over-refraction. Arithmetic calculation was close to the over-refraction. Conclusions: In predicting indications and powers of spherical RGP lens fitting, although there are the differences of axis between total (spectacle) astigmatism and corneal astigmatism, Spherical equivalent using an arithmetic calculation provides a more useful application than using a dioptric power matrix.

Cause Analysis in Decrease of Body Stability According to The Induced Astigmatic Blur (유발된 난시성 흐림에 의한 신체 안정성 감소의 원인분석)

  • Kim, Sang-Yeob;Yu, Dong-Sik;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제21권3호
    • /
    • pp.259-264
    • /
    • 2016
  • Purpose: To establish the cause of decrease in body stability and to analyze the effects on sensory organs maintaining static balance according to the induced astigmatic blur. Methods: Twenty subjects (10 males, 10 females; mean age, $23.40{\pm}2.70years$) were participated in this study. To induce myopic simple astigmatism, the axis directions of cylindrical lenses were placed $180^{\circ}$ on both eyes (with-the-rule), $90^{\circ}$ on both eyes (against-the-rule), and $45^{\circ}$ on both eyes (oblique). Cylindrical lenses of +0.50, +1.00, +1.50, +2.00, +3.00, +4.00, and +5.00 D were used to increase astigmatic blur in each astigmatism types. General stability (ST) and sway power (SP) in frequencies by each sensory organs were analyzed using the TETRAX biofeedback system. Results: ST in the all astigmatism types were raised with increase of astigmatic blur compared to full corrected condition, but a significant difference only showed in the induced oblique astigmatism. According to the results of correlation analysis between ST and SP in the each frequencies with increase of astigmatic blur, the causes of increased ST in the induced oblique astigmatism showed to have a high correlation in order of somatosensory system (high-medium frequency), central nervous system (high frequency), peripheral vestibular system (low-medium frequency), and visual system (low frequency). Conclusions: The visual information by uncorrected oblique astigmatism may disturb the normal functions of all sensory organs maintaining body balance, consequently, the body stability can be reduced. Therefore, optimal correction of astigmatism can play an important role for reducing the instability of body balance.

Implementation of a Self Controlled Mobile Robot with Intelligence to Recognize Obstacles (장애물 인식 지능을 갖춘 자율 이동로봇의 구현)

  • 류한성;최중경
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제40권5호
    • /
    • pp.312-321
    • /
    • 2003
  • In this paper, we implement robot which are ability to recognize obstacles and moving automatically to destination. we present two results in this paper; hardware implementation of image processing board and software implementation of visual feedback algorithm for a self-controlled robot. In the first part, the mobile robot depends on commands from a control board which is doing image processing part. We have studied the self controlled mobile robot system equipped with a CCD camera for a long time. This robot system consists of a image processing board implemented with DSPs, a stepping motor, a CCD camera. We will propose an algorithm in which commands are delivered for the robot to move in the planned path. The distance that the robot is supposed to move is calculated on the basis of the absolute coordinate and the coordinate of the target spot. And the image signal acquired by the CCD camera mounted on the robot is captured at every sampling time in order for the robot to automatically avoid the obstacle and finally to reach the destination. The image processing board consists of DSP (TMS320VC33), ADV611, SAA7111, ADV7l76A, CPLD(EPM7256ATC144), and SRAM memories. In the second part, the visual feedback control has two types of vision algorithms: obstacle avoidance and path planning. The first algorithm is cell, part of the image divided by blob analysis. We will do image preprocessing to improve the input image. This image preprocessing consists of filtering, edge detection, NOR converting, and threshold-ing. This major image processing includes labeling, segmentation, and pixel density calculation. In the second algorithm, after an image frame went through preprocessing (edge detection, converting, thresholding), the histogram is measured vertically (the y-axis direction). Then, the binary histogram of the image shows waveforms with only black and white variations. Here we use the fact that since obstacles appear as sectional diagrams as if they were walls, there is no variation in the histogram. The intensities of the line histogram are measured as vertically at intervals of 20 pixels. So, we can find uniform and nonuniform regions of the waveforms and define the period of uniform waveforms as an obstacle region. We can see that the algorithm is very useful for the robot to move avoiding obstacles.

A Study on the Characteristics of Museum Projects by Richard Meier (리챠드 마이어의 미술관 특성에 관한 연구)

  • 김용립
    • Archives of design research
    • /
    • 제12권4호
    • /
    • pp.231-241
    • /
    • 1999
  • This study propose to analyze the design method and the form elements of museums, of works by Richard Meier, and through the analysis, spacial characteristics of museums will be understood. The museum works of Richard Meier, as an exhibition space, not only display the art works efficiently, but they also offer visitors the opportunity to experience the art of architecture, as a cultural space. Richard Meier, when working on the projects, has utilized the design methods and the architectural language, learned from Mies van der Rohe and Le Corbusier, resourcefully. Having the structural grid as basis, the rational rectangular forms were intended for exhibition space, while the circular and partial circular forms of geometry were utilized in formative space. This was able to maintain the balance between functional and formative space. In the museums of his works, the ramp and the glass wall separated from the structure become very important means of expression. The ramps, not only make people to enjoy the interior and exterior of museum, but also able them to see the works of art from different distances and angles repeatedly and the large glass wall reveals the various shapes of interior to exterior. In comparing with the design method and language of two masters mentioned, the design principles and elements, developed by Meier were applied to the site plans, exhibition space planning and elevations to manifest its originality. The design concept, derived from the urban fabric and historical buildings around, gave harmony to the museum with its surroundings, and employing the deformed axis brought variation and the effect of diversion to the site plan. The exhibition space is much vitalized by the well arrangement of various exhibition fixtures in the museum. The exhibion fixtures, which the partitions, shelves, miches, and stages were put together in flexibility, play multiple roles as partitions dividing spaces, as furniture displaying art works, and as elements creating forms. The systematically arranged fixtures, also produce several visual axes and centers, which have visitors appreciate the works of art in various perspectives, hence create a unique environment.

  • PDF

Comparision of Trans-Tibial and Anteromedial Portal Approach in Femoral Tunneling of Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술의 대퇴골 터널 굴착시 경경골 접근법과 전내측통로 접근법의 비교)

  • Sohn, Sung-Keun;Chang, Yun-Suk;Chung, ll-Kwon;Kim, Kyung-Taek
    • Journal of the Korean Arthroscopy Society
    • /
    • 제8권2호
    • /
    • pp.75-81
    • /
    • 2004
  • Purpose: Recent development and advances in arthroscopic surgical techniques for Anterior Cruciate Ligament(ACL) reconstruction have led to the ideal location for the etric point from 10 o'clock (in right knee) and 13:30 (in left knee) to 10:30 (in right knee) and 14 o'clock (in left knee) in the frontal plane. This study was performed to compare operative methods and the radiologic results of femoral tunnels made through the tibial tunnel(trans-tibial approach) and the anteromedial portal. Material and Methods: From January 2003 to May 2004, one-hundred reconstructions of anterior cruciate ligament were performed. Group I (femoral tunnel through tibial tunnel) was composed of 50 cases and group ll (femoral tunnel through anteromedial portal) was consisted of 50 cases. The study was performed to compare the radiographic results of femoral tunnels made through the tibial tunnel and the anteromedial portal and operative methods. Results: In operative methods at Group II, femoral tunnel was made more easily at isometric point than Group I, a good visual field was achived because 100$^{\circ}$ flxion of knee, they can be reduced risk of posterior cortical breakage and tunnel-graft mismatching and decreased divergence of femoral interference screw in radiology (P<0.05). The angle between femoral tunnel and longitudinal axis of ACL wae increased at Group ll. Conclusion: Aanteromedial portal technique was more useful in ACL reconstruction for femoral tunnel toward 10 o'clock to10:30(in right) or 1:30 to 2 o'clock(in left).

  • PDF