• Title/Summary/Keyword: Visual Axis

Search Result 215, Processing Time 0.027 seconds

Generation of a practical visual field for the design and evaluation (제품설계와 평가를 위한 시각영역의 생성)

  • 기도형
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Depending upon the eye and head movement, the visual field is often classified into three categories ; stationary field, eye field and head and eye field. To investigate the effect of background condition on the size of the visual field, an experiment was conducted, in which the subject was instructed to search a target with distinct orientations. In each trial, a single target was presented on the perimeter modified to cover the range of 330 .deg. around the fixation point, with the visual angle subtended 1.4 .deg. vertically and horizontally. Nontarget density, meridian, size contrast and subject showed a significant effect on the visual field at .alpha. =0.01, where density was inversely proportional to the size of the visual field, and size contrast linearly proportional to the size of the visual field. The size of the visual field on horizontal axis was larger than that on vertical axis, and that on right and upper meridian was also larger than on left and lower meridian. The shape was found to be horizontally oriented oval and statistically asymmetric with respect to horizontal and vertical axes. In addition, the regression equations to predict the visual field on the given background condition were suggested. These results were expected to be used as a design guideline when arranging displays and controls on panels such as automobile display panels, cockpits, etc.

  • PDF

5 Axis Picomotor Control for Pixel matching in Holographic Data Storage (홀로그래픽 저장장치의 픽셀 매칭을 위한 5 축 피코모터 제어)

  • Lee Jae-Seung;Choi Jin-Young;Yang Hyun-Seok;Park Young-Pil
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1099-1102
    • /
    • 2005
  • In this paper, a new visual servo method, which uses 5 axis picomotor to compensate the misalignment generated between a SLM and a CCD in a holographic storage device, was proposed and the effectiveness of it was proved by the experiment. In a holographic storage device, the data processing is done by the SLM and the CCD, and the shape of data is 2 dimensional binary patterns. Therefore, the exact image matching between the SLM and the CCD is very important, and the mismatching of it causes the errors in the data reconstruction. First, the brief introduction of a holographic data storage is given, then, BER concept which is errors caused by pixel mismatch between the SLM and the CCD is defined. Second, the geometric relation between 5 axis picomotor and the CCD movement is studied. Finally, the visual servo method using 5 axis picomotor to reduce the BER in a holographic storage device is proposed and experimented. From the experiment, we find that about 3% BER improvement is obtained by the proposed method.

  • PDF

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF

Amblyopia Derived from Astigmatism in a Child Improved by Long-term Acupuncture Treatment: A Case Report (난시로 발생된 약시를 가진 소아에 대한 장기간 침 치료 1례)

  • Kim, Jun-Dong;Seo, Gwang-Yeel;Kim, Joong-Ho;Kim, Bong-Hyun
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.35 no.1
    • /
    • pp.58-62
    • /
    • 2022
  • Objectives : The aim of this study is to report the effect of long-term acupuncture on a amblyopia derived from astigmatism. Methods : A 39-month-old-female child presented with decreased visual acuity with simple astigmatism and amblyopia in the left eye. She took long-term acupuncture treatment once or twice a week for almost four years. And the autorefractor follow-up were conducted per every 6 months. Results : At the initial visit, naked eye visual acuity was 0.1/0.7(OD/OS), Sph. +0.00D, Cyl. -2.25D, AXIS 148° in the right eye, and Sph. +0.00D, Cyl. -0.25D, AXIS 49° in the left eye. After acupuncture treatment for about 4 years without correctional glasses, the visual acuity of the right eye was 1.0, the right eye had Sph. +0.00D, Cyl -0.50D, AXIS 146°, and the left eye had Sph. -0.25D, Cyl -0.50D, AXIS 154°. The visual acuity was maintained until 1 year follow up as 0.9/1.0(OD/OS). Conclusions : This study shows the possibility of using acupuncture treatment for amblyopia derived from astigmatism.

A study of Frequency Distributions by the Action styles (작업환경에서 오는 시력분포 및 고찰)

  • Kang, Hyang Nyeo;Kim, Sung Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.99-105
    • /
    • 2000
  • The classifying distribution by the action style was opticion 100, photoartist 100, college student 100 for the simple myopic 35%, for the simple myopic astigmatism 2%, for the compound myopic astigmatism 30.6% for the mixed astigmatism 62.6% for the compound hyperopic astigmatism 37.4% for the ratio of emmetropia 22.4% respectively. The retractive erroreye were -0.50~-2.00Dptr for the simple myopia 14%, -2.00~-6.00Dptr 16%, -6.00Dptr 5%, C-0.25(90.180)~C-2.00DptrAxis(90, 180) 2% for the simple myopicastigmatismS-0.25C-0.25DptrAxis(90, 180)~S-1.00C-1.00DptrAxis (90, 180) 22.6%, S-1.00C-1.00 DptrAxis (90, 180)~S-2.00C-2.00DptrAxis(90, 180) 8% for the compound myopic astigmatism. S+0.25C -0.25DptrAxis(90, 180)~S+2.00C-2.00DptrAxis(90,180) 6.2% for the mixed astigmatism. S+0.25C+0.25DptrAxis(90,180)~S+1.00C+1.00DptrAxis(90,180) 3.4%, S+1.00C+1.00DptrAxis(90,180)~S+2.00C+2.00DptrAxis(90,180) 0.34% for the compound hyperopic astigmatism.

  • PDF

Development of the Off-vertical Rotary Chair and Visual Stimulation system for Evaluation of the Vestibular Function (전정기능 평가를 위한 탈수직축 회전자극 시스템 및 HMD 시스템의 개발)

  • Kim Gyu-Gyeom;Ko Jong-Sun;Park Byung-Rim
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.377-380
    • /
    • 2001
  • The vestibular system located in the inner ear controls reflex body posture and movement. It has the semicircular canals sensing an angular acceleration and the otolith organs sensing a linear acceleration. With this organic signal, medical doctor decide if a person has disease or not. To obtain this data, a precision stimular system is considered. Robust control is needed to obtain eye signals induced by off-vertical axis rotation because of an unbalanced load produced by tilting the axis of the system upto 30 degrees. In this study, off-vertical axis rotatory system with visual stimulation system are developed. This system is consisted of head mounted display for generating horizontal, vertical, and three dimensional stimulus patterns. Furthermore wireless recording system using RF modem is considered for noiseless data transmission.

  • PDF

A Study of Selecting Sequential Viewpoint and Examining the Effectiveness of Omni-directional Angle Image Information in Grasping the Characteristics of Landscape (경관 특성 파악에 있어서의 시퀀스적 시점장 선정과 전방위 화상정보의 유효성 검증에 관한 연구)

  • Kim, Heung Man;Lee, In Hee
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.81-90
    • /
    • 2009
  • Relating to grasping sequential landscape characteristics in consideration of the behavioral characteristics of the subject experiencing visual perception, this study was made on the subject of main walking line section for visitors of three treasures of Buddhist temples. Especially, as a method of obtaining data for grasping sequential visual perception landscape, the researcher employed [momentum sequential viewpoint setup] according to [the interval of pointers arbitrarily] and fisheye-lens-camera photography using the obtained omni-directional angle visual perception information. As a result, in terms of viewpoint selection, factors like approach road form, change in circulation axis, change in the ground surface level, appearance of objects, etc. were verified to make effect, and among these, approach road form and circulation axis change turned out to be the greatest influences. In addition, as a result of reviewing the effectiveness via the subjects, for the sake of qualitative evaluation of landscape components using the VR picture image obtained in the process of acquiring omni-directional angle visual perception information, a positive result over certain values was earned in terms of panoramic vision, scene reproduction, three-dimensional perspective, etc. This convinces us of the possibility to activate the qualitative evaluation of omni-directional angle picture information and the study of landscape through it henceforth.

Nonlinear Analysis of Steel Frames Using Visual Basic (Visual Basic을 이용한 강뼈대 구조물의 비선형 해석)

  • 윤영조;김선희;이종석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.403-410
    • /
    • 1999
  • General1y, H-section is used for columns and beams in the middle and low steel building, But it has a strong and weak axis. Thus if H-section is used for columns, the structure needs reinforcement on the weak axis. Therefore recently, square holler section(S.H.S) is used for columns because it is able to coiler the vulnerability of H-section. Structural analysis is usually executed under the assumption that connections are either ideally pinned joint or fully rigid joint. Actually all connections are semi-rigid which possess a rotational stiffness. Therefore it can be designed economically as using the property of connections which has a rotational stiffness. This paper presents a prediction model curve which is fitted Kishi-Chen power Model about the behavior of connection between H-beam and S.H.S column. Non-linear analysis program was considered the non-linearity of semi-rigid connection and the geometrical non-linearity under the effect of axial force. It was programed by FORTRAN90 and Visual Basic.

  • PDF

An Analysis of Optical Performance of the Finite Schematic Eye According to Iris Eccentricity and Visual Axis change (시축 변화와 홍채 편심에 따른 정밀모형안의 광학적 성능 분석)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.151-154
    • /
    • 2010
  • Purpose: We investigated how the movement of iris and visual axis affects the finite schematic eye Methods: Using the schematic eye with the crystalline lens in the existing forms of the radial GRIN and the spherical GRIN, the iris centre was moved 0.5 mm in nasal direction and visual axis was tilted $5^{\circ}$ in same direction, with the additional degree of 2.5 down to locate the focal point in fovea. This study analyzed performance change of the optical system, designing it same as the real eye. Results: The whole aberration distribution showed a considerable difference in performance in comparison with the real eye; the biggest difference shown at the central field of optical system. The spherical aberration showed the biggest difference, and a peripheral power error and field curvature leaned toward (+) direction in aberration distribution. Conclusions: When designing the schematic eye with the performance similar with that of the real eye by taking into consideration the iris centre and visual axis, the aberration at the center field of optical system in particular should be corrected. Spherical aberration which showed the biggest difference should be corrected in the first place. In addition, a peripheral power error and field curvature that leaned toward (+) direction should be moved toward (-) direction.