• Title/Summary/Keyword: Visual Access and Exposure Model

Search Result 2, Processing Time 0.015 seconds

A Study on the Visibility Analysis Model for the Ward of General Hospital Considering Nurse's Circulation (종합병원 병동부 간호 이동 동선을 고려한 가시 특성 분석 모델에 관한 연구)

  • Kim, Seo-Yeong;Kweon, Jihoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.71-80
    • /
    • 2018
  • The path and visibility of nurses in general hospital wards have been treated as architectural planning factors. However, the analysis approach of existing studies shows limitations that only fixed physical elements are considered without considering the behavior of users using space. Consider factors for analysis of ward and models based on this study model. Select a case hospital to apply the analysis technique and conduct the nurse questionnaire and route survey of the hospital. Establish a framework for analysis model applied with the path of nurse movements. The analysis model applies to the case hospital. The analysis results are aggregated to derive design suggestion for reference to the spatial improvement of the ward. Visible visibility to observe the bedside in the nursing station, visibility to observe the beds in the nurse's path, and visibility to observe patients moving in the nurse's path were derived from visual access frequency and exposure frequency. The survey of nurses' movements at the site allowed the nurses to calculate the distance required to move. Reflecting the path of nurse movement, a model was presented for a comprehensive analysis of nursing distance and nursing visibility, which could lead to improvement in the observation and visibility of nurses and the layout of patient rooms or day rooms.

Variation Analysis of Distance and Exposure Dose in Radiation Control Area and Monitoring Area according to the Thickness of Radiation Protection Tool Using the Calculation Model: Non-Destructive Test Field (계산 모델을 활용한 방사선방어용 도구 두께에 따른 방사선관리구역 및 감시구역의 거리 및 피폭선량 변화 분석 : 방사선투과검사 분야 중심으로)

  • Gwon, Da Yeong;Park, Chan-hee;Kim, Hye Jin;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.279-287
    • /
    • 2020
  • Recently, interest in radiation protection is increasing because of the occurrence of accidents related to exposure dose. So, the nuclear safety act provides to install the shields to avoid exceeding the dose limit. In particular, when the worker conducts the non-destructive testing (NDT) without the fixed shielding structure, we should monitor the access to the workplace based on a constant dose rate. However, when we apply for permits for NDT work in these work environments, the consideration factors to the estimation of the distance and exposure dose are not legally specified. Therefore, we developed the excel model that automatically calculates the distance, exposure dose, and cost if we input the factors. We applied the assumption data to this model. As a result of the application, the distance change rate was low when the thickness of the lead blanket and collimator is above 25 mm, 21.5 mm, respectively. However, we didn't consider the scattering and build-up factor. And, we assumed the shape of the lead blanket and collimator. Therefore, if we make up for these limitations and use the actual data, we expect that we can build a database on the distance and exposure dose.