• Title/Summary/Keyword: Vision Analysis

Search Result 1,637, Processing Time 0.028 seconds

A Study on the Analysis of the Vision Achievement and Social Status of the ABEEK (한국공학교육인증원의 2020 비전 달성도 및 사회적 위상 분석)

  • Han, Jiyoung
    • Journal of Engineering Education Research
    • /
    • v.27 no.2
    • /
    • pp.3-12
    • /
    • 2024
  • The purpose of this study was to evaluate how well the 2020 vision presented by the Accreditation Board for Engineering Education of Korea(ABEEK) had been achieved, and to objectively examine the social status. It was very necessary for the development of engineering education in Korea to provide room for improvement by diagnosing how well the ABEEK, one of the major engineering education communities, was achieving its own vision. In order to achieve the objectives of the study, research methods such as literature review, survey research, and expert advisory committee were used. To evaluate the level of achievement of the Vision 2020 of the ABEEK, the analysis was based on the response results of 61 people who had experience as a member of the steering committe. In addition, the vision and mission of the 23 countries that are currently signatory members of the Washington Accord were surveyed, and the social responsibility and financial independence of the 20 countries that joined the signatory member countries before 2020 were compared with each other. As a result of the analysis, the item of securing international equivalence in engineering education received the most positive evaluation, and the social compensation efforts for accreditied graduates received the least evaluation. The ABEEK was evaluated as having a medium level of social responsibility and a low level of financial independence. Based on the results of this research, we proposed ways the ABEEK to contribute to the improvement of Korean engineering education.

Design Vision Box base on Embedded Platform (Embedded Platform을 기반으로 하는 Vision Box 설계)

  • Kim, Pan-Kyu;Hoang, Tae-Moon;Park, Sang-Su;Lee, Jong-Hyeok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.1103-1106
    • /
    • 2005
  • The purpose of this research is design of Vision Box which can capture an image which inputs through the camera and understand movement of object included in captured image. In design, we tried to satisfy user's requirements. We made Vision Box can analyze movement of object in image captured by camera without additional instruments. In addition, it is possible that communicate with PLC and operate Vision Box by remote control. We could verify the Vision Box capability by using it to automobile engine pattern analysis. We expect the Vision Box will be used various industrial fields.

  • PDF

An Optimal Combination of Illumination Intensity and Lens Aperture for Color Image Analysis

  • Chang, Y. C.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.35-43
    • /
    • 2002
  • The spectral color resolution of an image is very important in color image analysis. Two factors influencing the spectral color resolution of an image are illumination intensity and lens aperture for a selected vision system. An optimal combination of illumination intensity and lens aperture for color image analysis was determined in the study. The method was based on a model of dynamic range defined as the absolute difference between digital values of selected foreground and background color in the image. The role of illumination intensity in machine vision was also described and a computer program for simulating the optimal combination of two factors was implemented for verifying the related algorithm. It was possible to estimate the non-saturating range of the illumination intensity (input voltage in the study) and the lens aperture by using a model of dynamic range. The method provided an optimal combination of the illumination intensity and the lens aperture, maximizing the color resolution between colors of interest in color analysis, and the estimated color resolution at the combination for a given vision system configuration.

  • PDF

Comparative Analysis of Cost Aggregation Algorithms in Stereo Vision (스테레오 비전에서 비용 축적 알고리즘의 비교 분석)

  • Lee, Yong-Hwan;Kim, Youngseop
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Human visual system infers 3D vision through stereo disparity in the stereoscopic images, and stereo visioning are recently being used in consumer electronics which has resulted in much research in the application field. Basically, stereo vision system consists of four processes, which are cost computation, cost aggregation, disparity calculation, and disparity refinement. In this paper, we present and evaluate the existing various methods, focusing on cost aggregation for stereo vision system to comparatively analyze the performance of their algorithms for a given set of resources. Experiments show that Normalized Cross Correlation and Zero-Mean Normalized Cross Correlation provide higher accuracy, however they are computationally heavy for embedded system in the real time systems. Sum of Absolute Difference and Sum of Squared Difference are more suitable selection for embedded system, but they should be required on improvement to apply to the real world system.

Analysis of Requirements for Night Vision Imaging System (야시조명계통 요구도 분석)

  • Kwon, Jong-Kwang;Lee, Dae-Yearl;Kim, Whan-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.51-61
    • /
    • 2007
  • This paper concerns about the requirement analysis for night vision imaging system(NVIS), whose purpose is to intensify the available nighttime near infrared(IR) radiation sufficiently to be caught by the human eyes on a miniature green phosphor screen. The requirements for NVIS are NVIS radiance(NR), chromaticity, daylight legibility/readability, etc. The NR is a quantitative measure of night vision goggle (NVG) compatibility of a light source as viewed through goggles. The chromaticity is the quality of a color as determined by its purity and dominant wavelength. The daylight legibility/readability is the degree at which words are readable based on appearance and a measure of an instrument's ability to display incremental changes in its output value. In this paper, the requirements of NR, chromaticity, and daylight legibility/readability for Type I and Class B/C NVIS are analyzed. Also the rationale is shown with respect to those requirements.

Development of Computer Vision System for Individual Recognition and Feature Information of Cow (II) - Analysis of body parameters using stereo image - (젖소의 개체인식 및 형상 정보화를 위한 컴퓨터 시각 시스템 개발(II) - 스테레오 영상을 이용한 체위 분석 -)

  • 이종환
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.65-76
    • /
    • 2003
  • The analysis of cow body parameters is important to provide some useful information fur cow management and cow evaluation. Present methods give many stresses to cows because they are invasive and constrain cow postures during measurement of body parameters. This study was conducted to develop the stereo vision system fur non-invasive analysis of cow body features. Body feature parameters of 16 heads at two farms(A, B) were measured using scales and nineteen stereo images of them with walking postures were captured under outdoor illumination. In this study, the camera calibration and inverse perspective transformation technique was established fer the stereo vision system. Two calibration results were presented for farm A and fm B, respectively because setup distances from camera to cow were 510 cm at farm A and 630cm at farm B. Calibration error values fer the stereo vision system were within 2 cm for farm A and less than 4.9 cm for farm B. Eleven feature points of cow body were extracted on stereo images interactively and five assistant points were determined by computer program. 3D world coordinates for these 15 points were calculated by computer program and also used for calculation of cow body parameters such as withers height. pelvic arch height. body length. slope body length. chest depth and chest width. Measured errors for body parameters were less than 10% for most cows. For a few cow. measured errors for slope body length and chest width were more than 10% due to searching errors fer their feature points at inside-body positions. Equation for chest girth estimated by chest depth and chest width was presented. Maximum of estimated error fur chest girth was within 10% of real values and mean value of estimated error was 8.2cm. The analysis of cow body parameters using stereo vision system were successful although body shape on the binocular stereo image was distorted due to cow movements.

Vision-based Guidance for Loitering over a Target

  • Park, Sanghyuk
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.366-377
    • /
    • 2016
  • This paper presents a vision-based guidance method that allows a fixed-wing aircraft to orbit around a target at a given radius. The guidance method uses a simple formula that regulates a relative side-bearing angle estimated by a vision system. The global asymptotic stability of the associated guidance law is demonstrated, and a linear analysis is performed to facilitate the proper selection of the relevant control parameters. A flight experiment is presented to demonstrate the feasibility and performance of the proposed guidance method.

Inhibition of HIV-1 Protease by isoflavonoids from Erythrina senegalensis

  • Lee, Ji-Suk;Ma , Chao-Mei;Hattori Masao;Oh, Won-Keun;Ahn, Jong-Seog;Kim, Yong-Hae;Tanyi Mbaforj;Wandji Jean;Tanee FomumZ
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.377.3-378
    • /
    • 2002
  • Eight compounds were isolated from the MeOH extracts of Erythrina senegalensis for HIV-1 protease inhibitors. Their structures were elucidated as eight isoflavonoids by spectroscopic analysis. These compounds showed dose dependent inhibitory activities on HIV-l protease with $IC_{50}$ values from 0.5 to 30.0 ${\mu}$M. (omitted)

  • PDF

Effects of the Sensory Impairment on Functioning Levels of the Elderly (노인의 감각장애와 기능상태에 관한 연구)

  • 송미순
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.4
    • /
    • pp.678-693
    • /
    • 1993
  • The purposes of this study were to describe the level of vision and hearing impairments, depression and functional capacity, among Korean institutionalized elderly and to examine the relation-ship between sensory impairments, depression, and functional capacity in these people. The final pupose was to test the cognitive function path model using sensory competencies as predictors. A convenience sample of thirty nine male and 90 female subjects with a mean age of 80.5 were the subjects of this study. The subjects were tested for cognitive function, and vision and hearing impairments. Physical function and social function were measured by observation of designated task performance by the subjects. Their level of de-pression was measured using a Geriatric Depression Scale administered through an interview. Individual subjective ratings of hearing and vision were marked by the subjects, on a ladder scale. The results of the study showed that 48.8% of the subjects had a hearing impairment, 63.5% had a vision impairement, and 36.4% had both a vision and hearing impairement. The four sensory groups (no sensory impairement, hearing impairement, vision impairement, hearing and vision impairement) were tested for differences in depression, physical function, social behavior and cognitive function. The only significant difference that was found was in cognitive function, between the no sensory impairement group and the hearing and vision impairement group(F=3.25, P<.05), Subjective ratings of hearing showed a significant correlation with cognitive function(r=.34, p<.001) and with social behavior(r=.31, p<.001). There was no correlation between subjective vision ratings and cognitive function or social behavior. However there was a significant correlation between vision and hearing(r=.49, p<.001). There was also a significant negative correlation between age and vision(r=-.21, p<.01) and between age and hear-ing(r=-.34, p<.001). There was a significant correlation between depression and physical function (r=-.32, p<.001) but there was no correlation between depression and cognitive function or social behavior. Based on the literature review and the result, this study, a path model of sensory competence-> cognitive function- >social behavior was developed and tested : Perceived vision and perceived hearing were the exogenous variahles and cognitive function and social behavior were the endogeneous variables in the model. The path analysis result demonstrated an accept-able fit (GFI=.997, AGFI=.972, X$^2$=.72 (p=.396), RMSR=.019) between the data and the model. There was a significant direct effect($\beta$=.38) of perceived hearing on cognitive function. There was a significant direct effect ($\beta$=.32) of cognitive function on social behavior. The total effect of hearing on social behavior was $\beta$=.32 including the indirect effect ($\beta$=.12) . However perceived vsion had little effect ($\beta$=-.08) on cognitive function. The result of path analysis confirms that hearing levels influence cognitive function, and both hearing and cognitive function levels influence social behavior. However, vision has little effect on cognitive function or on social behavior. For the next study, a combined model of the pre viously developed environment - >depression- > physical and social function model, and the present cognitive function model, should be tested to further refine the functional capacity model. There also a need for longitudinal study of functional capacity and sencory competence in order to better understand how declining sensory competence influences functional capacity and how it effects in-creasing dependency and nursing needs in the elderly.

  • PDF

Comparative Analysis of the Training Fidelity of Vision Training Trainee (시기능 훈련 대상자의 훈련 충실도 비교 분석)

  • Kim, Ki-Hong;Lee, Chang-Seon;Lee, Jae Yoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.47-51
    • /
    • 2009
  • Purpose: The purpose of this case study is to analyze of the training fidelity of vision training trainee. Mehtods: The vision training observation group included 75 clients (male=40, female=35) who had binocular vision disorders without opthalmic diseases or vertical phoria. Results: A high degree of visiting rate and training fidelity showed improvement of binocular vision function, sensation and symptoms. It had a high degree of success rate and preference rate. Conclusions: We suggest that high training fidelity is an effective and alternative method for binocular vision disorder therapy.

  • PDF