• Title/Summary/Keyword: Visible Image

Search Result 501, Processing Time 0.029 seconds

Image Enhancement of an Infrared Thermal Camera Using Edge Detection Methods (에지 검출 방법을 이용한 열화상 카메라의 영상 개선)

  • Jung, Min Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.51-56
    • /
    • 2016
  • This paper proposes a new image enhancement method for an infrared thermal image. The proposed method uses both Laplacian and Prewitt edge detectors. Without a visible light, it uses an infrared image for the edge detection. The method subtracts contour images from the infrared thermal image. It results black contours of objects in the infrared thermal image. That makes the objects in the infrared thermal image distinguished clearly. The proposed method is implemented using C language in an embedded Linux system for a high-speed real-time image processing. Experiments were conducted by using various infrared thermal images. The results show that the proposed method is successful for image enhancement of an infrared thermal image.

Integration of Multiple Segmentation Methods based on Evaluation Functions for Segmentation of Visible Human Color Images (평가함수에 의해 혼합된 다수의 분할 방법을 적용한 Visible Human컬러 영상의 분할)

  • 김한영;김동성;강흥식
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.3_4
    • /
    • pp.308-315
    • /
    • 2003
  • This paper proposes an approach integrating multiple segmentation methods in a systematic way, which can improve overall accuracy without deteriorating accuracy of highly confident segments of boundaries generated by constituent methods. A segmentation method produces boundary segments, which are then evaluated with an evaluation function considering pros/cons of the current and next methods to apply. Boundary segments with low confidence are replaced by a next method while the other segments are kept. These steps are repeated until all segmentation methods are applied. The proposed approach is implemented for the segmentation of muscles in the Visible Human color images. A Balloon method, a minimum cost path finding method, and a Seeded Region Growing method are integrated. The final segmentation results showed improvements in both overall evaluation and segment-based evaluation.

Wavelet Transform based Image Registration using MCDT Method for Multi-Image

  • Lee, Choel;Lee, Jungsuk;Jung, Kyedong;Lee, Jong-Yong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.1
    • /
    • pp.36-41
    • /
    • 2015
  • This paper is proposed a wavelet-based MCDT(Mask Coefficient Differential and Threshold) method of image registration of Multi-images contaminated with visible image and infrared image. The method for ensure reliability of the image registration is to the increase statistical corelation as getting the common feature points between two images. The method of threshold the wavelet coefficients using derivatives of the wavelet coefficients of the detail subbands was proposed to effectively registration images with distortion. And it can define that the edge map. Particularly, in order to increase statistical corelation the method of the normalized mutual information. as similarity measure common feature between two images was selected. The proposed method is totally verified by comparing with the several other multi-image and the proposed image registration.

A highly integrable p-GaN MSM photodetector with GaN n-channel MISFET for UV image sensor system

  • Lee, Heon-Bok;Hahm, Sung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.346-349
    • /
    • 2008
  • A metal-semiconductor-metal (MSM) ultraviolet (UV) photodetector (PD) is proposed as an effective UV sensing device for integration with a GaN n-channel MISFET on auto-doped p-type GaN grown on a silicon substrate. Due to the high hole barrier of the metal-p-GaN contact, the dark current density of the fabricated MSM PD was less than $3\;nA/cm^2$ at a bias of up to 5 V. Meanwhile, the UV/visible rejection ratio was 400 and the cutoff wavelength of the spectral responsivity was 365 nm. However, the UV/visible ratio was limited by the sub-bandgap response, which was attributed to defectrelated deep traps in the p-GaN layer of the MSM PD. In conclusion, an MSM PD has a high process compatibility with the n-channel GaN Schottky barrier MISFET fabrication process and epitaxy on a silicon substrate.

Post-Processing for Reducing Corner Outliers (Corner outlier 제거를 위한 후처리 기법)

  • 홍윤표;전병우
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.11-14
    • /
    • 2003
  • In block-based lossy video compression, severe quantization causes discontinuities along block boundaries so that annoying blocking artifacts are visible in decoded video imases. These blocking artifacts significantly decrease the subjective image quality. In order to reduce the blocking artifacts in decoded images, many algorithms have been proposed However studies on so called, corner outliers, have been very limited. Corner outliers make image edges look disconnected from those of neighboring blocks at cross block boundary. In order to solve this problem, we propose a corner outlier detection and compensation algorithm as post-processing in spatial domain The experiment results show that the proposed method provides much improved subjective image quality.

  • PDF

Comparison between Colour Intensity of Tongue Body and That of Tongue Coat under the Ultraviolet Light in RGB system of Peeling Tongue Coat Image (RGB 컬러모델에서 자외선 조명하 박락태(剝落苔)의 설태와 설질 사이의 색 강도 차이에 관한 연구)

  • Nam, Dong-Hyun;Kim, Ji-Hye;Lee, Woo-Beom;Lee, Sang-Suk;Hong, You-Sik
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.2
    • /
    • pp.149-158
    • /
    • 2011
  • Objectives: The objective of this study is to compare the colour intensity of tongue body and that of tongue coat under the visible light and the ultraviolet light. Methods: We selected 7 subjects with completely or partially peeled tongue coat among the recruited 94 adults for the experiment. We took each tongue picture under the visible light and the ultraviolet light (315-400 nm) and then extracted sample images from the tongue body and tongue coat regions. Mean, median and mode of colour intensity from the sample images were calculated in 256 RGB system. Results: The green and the blue colour intensities of the tongue coats were significantly higher than those of the tongue bodies under the visible light. In all channels, the red, green and blue, the colour intensities of the tongue coats were significantly higher than those of the tongue bodies under the ultraviolet light. The colour differences between tongue coats and tongue bodies under the ultraviolet light were significantly higher than the colour differences under the visible light. Especially the colour difference under the ultraviolet light was highest in the green channel. Conclusions: We suggested that green colour image of the RGB system taken under the ultraviolet light could be used for more easy separating tongue coat region from tongue body.

Visual Analysis for Detection and Quantification of Pseudomonas cichorii Disease Severity in Tomato Plants

  • Rajendran, Dhinesh Kumar;Park, Eunsoo;Nagendran, Rajalingam;Hung, Nguyen Bao;Cho, Byoung-Kwan;Kim, Kyung-Hwan;Lee, Yong Hoon
    • The Plant Pathology Journal
    • /
    • v.32 no.4
    • /
    • pp.300-310
    • /
    • 2016
  • Pathogen infection in plants induces complex responses ranging from gene expression to metabolic processes in infected plants. In spite of many studies on biotic stress-related changes in host plants, little is known about the metabolic and phenotypic responses of the host plants to Pseudomonas cichorii infection based on image-based analysis. To investigate alterations in tomato plants according to disease severity, we inoculated plants with different cell densities of P. cichorii using dipping and syringe infiltration methods. High-dose inocula (${\geq}10^6cfu/ml$) induced evident necrotic lesions within one day that corresponded to bacterial growth in the infected tissues. Among the chlorophyll fluorescence parameters analyzed, changes in quantum yield of PSII (${\Phi}PSII$) and non-photochemical quenching (NPQ) preceded the appearance of visible symptoms, but maximum quantum efficiency of PSII ($F_v/F_m$) was altered well after symptom development. Visible/near infrared and chlorophyll fluorescence hyperspectral images detected changes before symptom appearance at low-density inoculation. The results of this study indicate that the P. cichorii infection severity can be detected by chlorophyll fluorescence assay and hyperspectral images prior to the onset of visible symptoms, indicating the feasibility of early detection of diseases. However, to detect disease development by hyperspectral imaging, more detailed protocols and analyses are necessary. Taken together, change in chlorophyll fluorescence is a good parameter for early detection of P. cichorii infection in tomato plants. In addition, image-based visualization of infection severity before visual damage appearance will contribute to effective management of plant diseases.

Hierarchical Non-Rigid Registration by Bodily Tissue-based Segmentation : Application to the Visible Human Cross-sectional Color Images and CT Legs Images (조직 기반 계층적 non-rigid 정합: Visible Human 컬러 단면 영상과 CT 다리 영상에 적용)

  • Kim, Gye-Hyun;Lee, Ho;Kim, Dong-Sung;Kang, Heung-Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.259-266
    • /
    • 2003
  • Non-rigid registration between different modality images with shape deformation can be used to diagnosis and study for inter-patient image registration, longitudinal intra-patient registration, and registration between a patient image and an atlas image. This paper proposes a hierarchical registration method using bodily tissue based segmentation for registration between color images and CT images of the Visible Human leg areas. The cross-sectional color images and the axial CT images are segmented into three distinctive bodily tissue regions, respectively: fat, muscle, and bone. Each region is separately registered hierarchically. Bounding boxes containing bodily tissue regions in different modalities are initially registered. Then, boundaries of the regions are globally registered within range of searching space. Local boundary segments of the regions are further registered for non-rigid registration of the sampled boundary points. Non-rigid registration parameters for the un-sampled points are interpolated linearly. Such hierarchical approach enables the method to register images efficiently. Moreover, registration of visibly distinct bodily tissue regions provides accurate and robust result in region boundaries and inside the regions.

Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging (웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발)

  • Ahn, Misook;Han, Yong-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.

Inter-vehicular Distance Estimation Scheme Based on VLC using Image Sensor and LED Tail Lamps in Moving Situation (후미등의 가시광통신을 이용한 이동상황에서의 영상센서 기반 차량 간 거리 추정 기법)

  • Yun, Soo-Keun;Jeon, Hui-Jin;Kim, Byung Wook;Jung, Sung-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.935-941
    • /
    • 2017
  • This paper proposes a method for estimating the distance betweeen vehicles in a moving situation using the image ratio of the distance between the tail lamps of a front vehicle. The actual distance between the tail lamps of a front vehicle was transmitted by LED tail lamps using visible light communication. As the distance between the front vehicle and the rear vehicle changes, it calculates the ratio of the pixel width between the tail lamps of the front vehicle projected on the image. The calculated values are used to derive a distance-mapping function through non-linear regression technique. Then, the distance between vehicles in the moving situation is estimated based on this function.