• Title/Summary/Keyword: Visible Frequency

Search Result 303, Processing Time 0.033 seconds

Variation of Agronomic Traits of Rice Mutant Lines Induced by Sodium Azide

  • Shin, Young-Seop;Jeon, Yong-Hee;Kang, Kyung-Ho;Seo, Yong-Weon;Jeung, Ji-Ung
    • Korean Journal of Breeding Science
    • /
    • v.41 no.2
    • /
    • pp.92-100
    • /
    • 2009
  • To investigate the mutagenecity of sodium azide (SA) and to select mutants having various agronomic characteristics in rice (Oryza sativa L. ssp. japonica), dry seeds of rice variety 'Suweon 472' were treated with 0, 0.5, 1.0, 2.0, and 4.0 mM SA solutions prepared in 0.1 M phosphate buffer (pH 3.0). Germination rate, seedling height and sterility were investigated in $M_1$ generation and chlorophyll mutations were observed in $M_3$ generation. Germination rate and seedling height decreased as the increase of SA concentration in $M_1$ generation, the maximum seed sterility (40.8%) was found at 4.0 mM SA concentration. Chlorophyll mutants were occurred in $M_3$ generation and the frequency calculated on a line basis was 13.5% at the same treatment. Many kinds of mutations for morphological and agronomic characters were observed and mutations with short culm and glabrous leaf were frequently found in $M_3$ generation. Interestingly, five mutant lines resistant to blast or bacterial blight (BB) were selected and evaluated with several isolates in $M_3$ generation although Suweon 472 has been known to be susceptible to blast and BB. These mutants showed all resistance to seven isolates of blast and a total of 76 lines among 2,567 lines evaluated showed resistant to race K1 of bacterial blight. Two mutant lines (440172 and 41272) showed different reaction to BB isolates from the other resistant mutants. A few kinds of endosperm mutants were also identified and most of them were waxy mutants.

Intraoperative Neurophysiologic Testing of the Perigastric Vagus Nerve Branches to Evaluate Viability and Signals along Nerve Pathways during Gastrectomy

  • Kong, Seong-Ho;Kim, Sung Min;Kim, Dong-Gun;Park, Kee Hong;Suh, Yun-Suhk;Kim, Tae-Han;Kim, Il Jung;Seo, Jeong-Hwa;Lim, Young Jin;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.19 no.1
    • /
    • pp.49-61
    • /
    • 2019
  • Purpose: The perigastric vagus nerve may play an important role in preserving function after gastrectomy, and intraoperative neurophysiologic tests might represent a feasible method of evaluating the vagus nerve. The purpose of this study is to assess the feasibility of neurophysiologic evaluations of the function and viability of perigastric vagus nerve branches during gastrectomy. Materials and Methods: Thirteen patients (1 open total gastrectomy, 1 laparoscopic total gastrectomy, and 11 laparoscopic distal gastrectomy) were prospectively enrolled. The hepatic and celiac branches of the vagus nerve were exposed, and grabbing type stimulation electrodes were applied as follows: 10-30 mA intensity, 4 trains, $1,000{\mu}s/train$, and $5{\times}$frequency. Visible myocontractile movement and electrical signals were monitored via needle probes before and after gastrectomy. Gastrointestinal symptoms were evaluated preoperatively and postoperatively at 3 weeks and 3 months, respectively. Results: Responses were observed after stimulating the celiac branch in 10, 9, 10, and 6 patients in the antrum, pylorus, duodenum, and proximal jejunum, respectively. Ten patients responded to hepatic branch stimulation at the duodenum. After vagus-preserving distal gastrectomy, 2 patients lost responses to the celiac branch at the duodenum and jejunum (1 each), and 1 patient lost response to the hepatic branch at the duodenum. Significant procedure-related complications and meaningful postoperative diarrhea were not observed. Conclusions: Intraoperative neurophysiologic testing seems to be a feasible methodology for monitoring the perigastric vagus nerves. Innervation of the duodenum via the celiac branch and postoperative preservation of the function of the vagus nerves were confirmed in most patients.

Behavior of the Ultrasonically-atomized Liquid-fuel Flame Injected through a Slit-jet Nozzle (Slit-jet 노즐을 통해 분사되는 초음파 무화 액체연료 화염의 거동)

  • Kim, Min Cheol;Kim, Min Sung;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.1-10
    • /
    • 2018
  • An experimental study was performed for the behavior of the burner flame which results from burning of the liquid hydrocarbon fuel atomized by an ultrasonic transducer. Configurations of the flame and combustion-field were caught by both high-speed camera and thermo-graphic camera, and those images were analyzed in detail through a image post-processing. As a result, the combustion-field grew and reaction-temperature rose due to the strengthening of combustion reaction with the increasing flow-rate of carrier-gas. In addition, a phenomenon of flame flickering was discussed through the comparative analysis of the variational behavior between the visible flame and IR (Infrared) flame-field. Also, the flickering frequency of the flame was confirmed through FFT (Fast Fourier Transform) analysis employing the flame area.

Effect of Deposition Temperature on the Optical Properties of La2MoO6:Dy3+,Eu3+ Phosphor Thin Films (증착 온도에 따른 La2MoO6:Dy3+,Eu3+ 형광체 박막의 광학 특성)

  • Cho, Shinho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.5
    • /
    • pp.387-392
    • /
    • 2019
  • $Dy^{3+}$ and $Eu^{3+}$-co-doped $La_2MoO_6$ phosphor thin films were deposited on sapphire substrates by radio-frequency magnetron sputtering at various growth temperatures. The phosphor thin films were characterized using X-ray diffraction (XRD), scanning electron microscopy, ultraviolet-visible spectroscopy, and fluorescence spectrometry. The optical transmittance, absorbance, bandgap, and photoluminescence intensity of the $La_2MoO_6$ phosphor thin films were found to depend on the growth temperature. The XRD patterns demonstrated that all the phosphor thin films, irrespective of growth temperatures, had a tetragonal structure. The phosphor thin film deposited at a growth temperature of $100^{\circ}C$ indicated an average transmittance of 85.3% in the 400~1,100 nm wavelength range and a bandgap energy of 4.31 eV. As the growth temperature increased, the bandgap energy gradually decreased. The emission spectra under ultraviolet excitation at 268 nm exhibited an intense red emission line at 616 nm and a weak emission line at 699 nm due to the $^5D_0{\rightarrow}^7F_2$ and $^5D_0{\rightarrow}^7F_4$ transitions of the $Eu^{3+}$ ions, respectively, and also featured a yellow emission band at 573 nm, resulting from the $^4F_{9/2}{\rightarrow}^6H_{13/2}$ transition of the $Dy^{3+}$ ions. The results suggest that $La_2MoO_6$ phosphor thin films can be used as light-emitting layers for inorganic thin film electroluminescent devices.

Optically Transparent ITO Film and the Fabrication of Plasma Signboard (투명 전극 ITO 박막의 열처리 영향과 플라즈마 응용 표시소자 제작에 관한 연구)

  • Jo, Young Je;Kim, Jae-Kwan;Han, Seung-Cheol;Kwak, Joon-Seop;Lee, Ji-Myon
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • Indium tin oxide(ITO) thin films were deposited on the glass substrates by radio-frequency (RF) magnetron sputtering method. The influence of rapid thermal annealing (RTA) treatment on the optical and electrical properties of the films were investigated for the purpose of fabricating plasma display signboard. Structural properties, surface roughness, sheet resistance and transmittance of the ITO film were analysed by using x-ray diffraction method, atomic force microscopy (AFM), four point prove, and ultraviolet-visible spectrometer, respectively. It was found that the RTA treatment increased the transmittance and decreased the resistivity of the ITO film, respectively. Furthermore, we successfully demonstrated the direct-current plasma signboard by using ITO electrode and phosphors.

Diagnosis of split fractures of the mandible in adults

  • Taesik Kim;Sung Gyun Jung;In Pyo Hong;Young Joong Hwang
    • Archives of Craniofacial Surgery
    • /
    • v.24 no.4
    • /
    • pp.167-173
    • /
    • 2023
  • Background: Mandibular split fractures, in which the fracture occurs exclusively in the posterior wall, are uncommon. This study aimed to enhance clinicians' understanding of mandibular split fractures and offer insights for future research. Methods: This study included six patients who visited our hospital between January 2020 and June 2023 and were diagnosed with mandibular split fractures. We retrospectively collected data from patients' medical records on their age, sex, symptoms, mechanism, impact site, associated injuries, and treatment method, as well as the location, pattern, and number of fractures observed on computed tomography (CT) and panoramic images. The frequency of split fractures among all mandibular fractures was calculated. Results: The six patients included three men (50%) and three women (50%), ranging in age from 20 to 71 years (mean age, 49.8 years). The split fractures were located in the symphysis in one patient (16.7%), symphysis to parasymphysis in two patients (33.3%), parasymphysis in one patient (16.7%), and parasymphysis to the body in two patients (33.3%). Four patients (66.7%) had condylar head fractures, while two patients (33.3%) had single split fractures. The mechanism of trauma was a slip-down incident in four cases (66.7%), while two cases (33.3%) were caused by motorcycle traffic accidents. Four patients (67%) underwent intermaxillary fixation, while two patients (33%) improved with conservative treatment. Split fractures were diagnosed in all six patients on CT, whereas the fracture line was not clearly visible on panoramic images. Mandibular split fractures accounted for 5.6% of all mandibular fractures. Conclusion: This study provides insights into the clinical characteristics of rare mandibular split fractures and the diagnostic imaging findings. Furthermore, CT scans and three-dimensional image synthesis-instead of panoramic images-may be essential for accurately diagnosing mandibular fractures, including mandibular split fractures, in the future.

Fabrication of IZO thin films for flexible organic light emitting diodes by RF magnetron sputtering

  • Jun, D.G.;Cho, H.H.;Jo, D.B.;Lee, K.M.
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.260-264
    • /
    • 2012
  • We have investigated the effect of ambient gases on the structural, electrical, and optical characteristics of IZO thin films intended for use as anode contacts in the organic light emitting diodes (OLED) devices. These IZO thin films were deposited on the PES film by radio frequency (RF) magnetron sputtering under different ambient gases (Ar, Ar + O2, and Ar + H2) at room temperature. In order to investigate the influences of the ambient gases, the flow rate of oxygen and hydrogen in argon has been changed from 0.1 sccm to 0.5 sccm, respectively. All the IZO thin film has an (222) preferential orientation regardless of ambient gases. The electrical resistivity of the IZO film increased with increasing O2 flow rate, whereas the electrical resistivity decreased sharply under an Ar + H2 atmosphere and was nearly similar regardless of the H2 flow rate. The change of electrical resistivity with changes in the ambient gas composition was mainly interpreted in terms of the charge carrier concentration rather than the charge carrier mobility. All the films showed the average transmittance over 85% in the visible range. The OLED device was fabricated with different IZO substrates made with the configuration of IZO/α-NPD/DPVB/Alq3/LiF/Al in order to elucidate the performance of the IZO substrate. The current density and the luminance of OLED devices with IZO thin films deposited in 0.5 sccm H2 ambient gas are the highest amongst all other films.

A Study on the Experience of Physical Therapy Accident in The Physiotherapist (물리치료사에 있어서 물리치료 사고의 경험에 관한 연구)

  • Kim, Jong-Dae
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.1
    • /
    • pp.69-80
    • /
    • 2002
  • The objective of research provides the physical therapy of good quality to the patients to search for the problem pant against a physical therapy accident and it simultaneously respects physical therapy company law, the possibility of preparing a system defensive ability in order to be. The data were collected from 2000 October 1 to December 30th, and analyzed by a frequency and a percentage, oneway ANOVA, Scheffe method, $x^2$ official approvals. Conclusion (1) the accident where the patient falls from inside the treatment 'room is many and occasionally' 29.3% (63 people) with was many most. (2) Because of a mistake by a part-time therapist in holiday or a colleague therapist to do, the fracture or bum accident happens 12.5% (27 people), by a assist nurse due to more showed 12.1% (26 people) experience degree in the patient. (3) From physical therapy process breakdown of the medical treatment machinery and tools or it is in malfunction to do and the experience which has a failure to physical therapy is one enemy 68.1% (147 people) was in item. Also it treats and the patient or in the protector it sends an explanation in advance not to be, the experience which it enforces 50% (108 people), of service hour treatment equipment the medical treatment directives broad way of the doctor is accurate in insufficiency and does not enforce the experience is 45.4% (98 people), the patient whom I am treating Hot Pack (electricity has pack inclusion) with to do, the art dealer (over at 1 buffoonery) the experience which it puts on 27.1% (58 people), The patient whom I am treating is the electrotherapy flag (electricity has pack exclusion) with to do, the art dealer (1 degree art dealer over) the experience which it puts on 16.3% (35 people), the experience boat song the patient against a fracture from physical therapy process 9 person (4.2%) was visible an experience degree. (4) With hospital infection to do, from the patient the experience and the therapist which receive a problem proposal were caused by with hospital infection and the answer back regarding the experience which tries to receive a treatment appeared 6% (13 people), 42% (9 people) with each. (5) It listened to the treatment hour patient or the appeal of the protector and especially it does not appear to be being important it was not and and the management which is special it did not take, also the experience where the condition of the patient is deteriorated after that was 10.3% (22 people). (6) The condition or state of the patient does not agree with the medical treatment instruction of the doctor not to be, amendment one experience was 67.5% (145 people). (7) The experience degree of the physical therapy accident which relates with physical therapy recording and a secret maintenance 59.7% (129 people) 'is many and occasionally it is,' it showed an answer back and e it showed a most high accident experience degree. (8) The business overweight of physical therapy company 43.3% (93 people) with was high most from recognition degree of the physical therapy company against a physical therapy accident. (9) Against the question which asks the responsibility subject matter of physical therapy accident the whole answer back volition 42.8% did it is a joint responsibility where the multi person relates. (10) The accident occurs most the hour unit which plentifully in the afternoon 64.3% (133 people) with appeared from the recognition degree against the frequency hour unit of physical therapy accident. (11) Physical therapy it bought and after the various medical treatment accident which relates against the attitude of the, patient side against the physical therapy company it understood and trillion it was many most with 33.3% to be finished. (12) After physical therapy accident the management against the physical therapy company of the hospital authorities concerned above all do not experience 70.6% (149 people), from event right and wrong submission 22.7% (48 people), warning management 2.8% (6 people), the event report requirement and money compensation were each 0.5% (1 person). (13) As the prevention book of physical therapy accident most it is important, the fact which it thinks that, the persons supplement of physical therapy company 58.8% (127 people) with was high most. (14) It related with a physical therapy accident and the medical law 43.5%, civil law 23.9%, was visible the answer back ratio of the criminal law 13.7% from the degree which probably is a relation law.

  • PDF

Response of circular footing on dry dense sand to impact load with different embedment depths

  • Ali, Adnan F.;Fattah, Mohammed Y.;Ahmed, Balqees A.
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.323-336
    • /
    • 2018
  • Machine foundations with impact loads are common powerful sources of industrial vibrations. These foundations are generally transferring vertical dynamic loads to the soil and generate ground vibrations which may harmfully affect the surrounding structures or buildings. Dynamic effects range from severe trouble of working conditions for some sensitive instruments or devices to visible structural damage. This work includes an experimental study on the behavior of dry dense sand under the action of a single impulsive load. The objective of this research is to predict the dry sand response under impact loads. Emphasis will be made on attenuation of waves induced by impact loads through the soil. The research also includes studying the effect of footing embedment, and footing area on the soil behavior and its dynamic response. Different falling masses from different heights were conducted using the falling weight deflectometer (FWD) to provide the single pulse energy. The responses of different soils were evaluated at different locations (vertically below the impact plate and horizontally away from it). These responses include; displacements, velocities, and accelerations that are developed due to the impact acting at top and different depths within the soil using the falling weight deflectometer (FWD) and accelerometers (ARH-500A Waterproof, and Low capacity Acceleration Transducer) that are embedded in the soil in addition to soil pressure gauges. It was concluded that increasing the footing embedment depth results in increase in the amplitude of the force-time history by about 10-30% due to increase in the degree of confinement. This is accompanied by a decrease in the displacement response of the soil by about 40-50% due to increase in the overburden pressure when the embedment depth increased which leads to increasing the stiffness of sandy soil. There is also increase in the natural frequency of the soil-foundation system by about 20-45%. For surface foundation, the foundation is free to oscillate in vertical, horizontal and rocking modes. But, when embedding a footing, the surrounding soil restricts oscillation due to confinement which leads to increasing the natural frequency. Moreover, the soil density increases with depth because of compaction, which makes the soil behave as a solid medium. Increasing the footing embedment depth results in an increase in the damping ratio by about 50-150% due to the increase of soil density as D/B increases, hence the soil tends to behave as a solid medium which activates both viscous and strain damping.

Environmental Test Results of a Flight Model of a Compact Imaging Spectrometer for a Microsatellite STSAT-3 (과학기술위성3호 소형영상분광기 발사모델 환경시험 결과)

  • Lee, Sang-Jun;Kim, Jung-Hyun;Lee, Jun-Ho;Lee, Chi-Won;Jang, Tae-Sung;Kang, Kyung-In
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.184-190
    • /
    • 2011
  • A compact imaging spectrometer (COMIS) was developed for a microsatellite STSAT-3. The satellite is now rescheduled to be launched into a low sun-synchronous Earth orbit (~700 km) by the end of 2012. Its main operational goal is the imaging of the Earth's surface and atmosphere with ground sampling distance of 27 m and 2 - 15 nm spectral resolution over visible and near infrared spectrum (0.4 - 1.05 ${\mu}m$). A flight model of COMIS was developed following an engineering model that had successfully demonstrated hyperspectral imaging capability and structural rigidity. In this paper we report the environmental test results of the flight model. The mechanical stiffness of the model was confirmed by a small shift of the natural frequency i.e., < 1% over 10 gRMS random vibration test. Electrical functions of the model were also tested without showing any anomalies during and after vacuum thermal cycling test with < $10^{-5}$ torr and $-30^{\circ}C\;-\;35^{\circ}C$. The imaging capability of the model, represented by a modulation transfer function (MTF) value at the Nyquist frequency, was also kept unvaried after all those environmental tests.