Korean Journal of Air-Conditioning and Refrigeration Engineering
/
v.11
no.4
/
pp.549-559
/
1999
An experimental study was peformed to measure the viscosity of microencapsulated PCM slurries as the functions of its concentration and temperature, and also influence to its fluid dynamics. For the viscosity measurement, a rotary type viscometer, which was equipped with temperature control system, was adopted. The slurry was mixed with water and Sodium Lauryl Sulphate as a surfactant by which its suspended particles were dispersed well without the segregation of particles during the experiment. The viscosity was increased as the concentration of MicroPCM particle added. The surfactant increased 5% of the viscosity over the working fluid without particles. Experiments were proceeded by changing parameters such as PCM particles'concentration as well as the temperature of working fluid. As a result, a model to the functions of temperature for the working fluid and its particle concentration is proposed. The proposed model, for which its standard deviation shows 0.8068, is agreed well with the reference's data. The pressure drop was measured by U-tube manometer, and then the friction factor was obtained. It was noted that the pressure drop was not influenced by the state of PCM phase, that is solid or liquid in its core materials at their same concentration. On the other hand, it was described that the pressure drop of the slurry was much increased over the working fluid without particles. A friction factor was placed on a straight line in all working fluids of the laminar flow regardless of existing particles as we expected.
Journal of the Korean Society of Food Science and Nutrition
/
v.28
no.5
/
pp.1082-1086
/
1999
Dried vegetables, white ginseng and spices, which were exposed to gamma and electron beam irradiation, were used in a detection study by measuring their starch content and viscosity change. The samples tested showed different levels of starch content(15.64~60.86%), which was not directly proportional to the viscosity of the samples. The correlation coefficients between irradiation dose and viscosity change were lower in the samples, such as cabbage, carrot, clean vegetable(chunggyungchae), garlic, mushroom, green onion, and red pepper, while some higher coefficients were found in ginger(R2=0.9271), white ginseng (R2=0.6223) and onion (R2=0.7909). Thus, dried ginger and white ginseng were selected to be used for a detection of irradiated samples using specific parameters(threshold values). Specific parameter for the nonirradiated ginger and ginseng were 13.31 and 13.93, respectively. On the other hand, gamma and electron beam irradiated samples at 2.5 kGy, the lowest dose for a commercial purpose, showed decreased values, 11.92 and 11.15 in ginger, and moreover 4.40 and 5.10 in ginseng. It is expected that a proportional decrease in a specific parameter with the absorbed doses will be a potentially useful index for detecting whether starchy foods have been irradiated or not.
This research was conducted to analyze the change of surface tension, viscosity, streaming current and conductivity of transformer oil when it were injected with the interface active substances.(anionic:S-111, cationic:S-121, amphoteric:S-131) The changes properties of the surface tension and viscosity of the oil which were injected with the interface active substances were divided into the changes area and the minimum reduction area. The surface tension and viscosity of the oil which were injected with three different kinds of interface active substances showed remarkable change at the point where the concentration of the substance in anionic, in cationic and in amphoteric were 100[ppm], 10[ppm] and 1[ppm] respectively. The streaming current and conductivity of the same sample oil were also changed at the same densities of the surface tension and viscosity. For this factor, it was possibile for us to interpret the mechanism of the streaming current and conductivity. Therefore the interface active substances of the three kinds were injected into the oil within the limit of optimal volume, prevention effects of electrification were showed more excellence than unmixed insulating oil.
A newly designed mass-detecting capillary viscometer uses a novel concept to continuously measure non-Newtonian fluids viscosity over a range of shear rates. A single measurement of liquid-mass variation with time replaces the now rate and pressure drop measurements that are usually required by capillary tube viscometers. Using a load cell and a capillary, we measured change in the mass flow rate through a capillary tube with respect to the time, m(t), from which viscosity and shear rate were mathematically calculated. For aqueous polymer solutions, excellent agreement was found between the results from the mass-detecting capillary viscometer and those from a commercially available rotating viscometer. This new method overcomes the drawbacks of conventional capillary viscometers meassuring non-Newtonian fluid viscosity. First, the mass-detecting capillary viscometer can accurately and consistently measure non -Newtonian viscosity over a wide range of shear rate extending as low as 1 s$\^$-1/. Second, this design provides simplicity (i. e., ease of operation, no moving parts), and low cost.
Proceedings of the Korean Institute of Building Construction Conference
/
2017.05a
/
pp.171-172
/
2017
In order to meet the high performance of the concrete, the viscosity increases with water binder ratio and amount of powder. because of these problems, we use high performance water reducing agent and low viscosity water reducing agent, but side effects may occur when using large amount of water reducing agent. Therefore, in this research, in order to increase the viscosity, I would like to analyze the change in viscosity and flow characteristics of paste by utilizing fly ash and lung limestone which are generally thrown away without using high performance water reducing agent.
I selected the theory of blood stasis and wetness-phlegm among the major 4 causes of Joong Poong(C.V.A.)(wind. fire. deficiency of vital energy and wetness-phlegm) and recent etiology of blood stasis. An experimental studies were done to investigate the effects of Danggieum (removing blood stasis and promoting blood circulation) and Ijintang(dissipating wetness-phlegm) on thrombosis and elevated blood viscosity. The results were as follows; 1. The number of platelets were significantly increased in only Danggieum group. 2. Related to the amount of fibrinogen. only Danggieum group revealed some increase. but both groups revealed no significance. 3. Related to the prothrombin time. Danggieum and Ijintang groups had significant decrease. but Danggieum group revealed more significance. 4. Related to the degree of concentration of FDP, only Danggieum group had significant decrease. 5. Whole blood viscosity and plasma viscosity in lower shear rates. both groups of Danggieum and Ijintang had significant decrease. 6. Related to the amount of RBC. both groups of Danggieum and Ijintang had significant decrease. 7. Related to the change of hematocrit. only Danggieum group, and the change of hemoglobin. only Ijintang group had significant decrease. 8. Related to the change of body temperature. only Ijintang group had significant raise. 9. Related to the changes of WBC. glucose, albumin, total protein and body weight. Danggieum and Ijintang groups had each increase or decrease. but no significance. According to the above results, Danggieum had more significant effect than Ijintang on the thrombosis. and Ijintang had more significant effect than Danggieum on the elevated blood viscosity. And it is considered that it might be more effective in treating Joong-Poong(C.V.A) to take medicines regarding patient's constitution and symptoms as well as the causes of Joong-Poong(C.V.A)
A study was carried out to establish a detection method for irradiated black pepper using amylograph characteristics. The maximum viscosity, viscosity at $93^{\circ}C$, viscosity after 15 min at $93^{\circ}C$, viscosity at $45^{\circ}C$, viscosity after 30 min at $45^{\circ}C$, and viscosity after 60 min at $45^{\circ}C$ decreased with increasing irradiation doses, but initial pasting temperatures, maximum viscosity temperatures, breakdown, setback, and consistency did not show great changes. The high correlation coefficients $(R^2>0.97)$ were shown between irradiation doses and amylograph characteristics except for breakdown $(R^2>0.75)$, setback $(R^2>0.88)$ and consistency $(R^2>0.31)$. These results suggest that detection of irradiated black pepper is possible using amylograph characteristics.
The relative viscosity was measured at different filler loadings for a cycloaliphatic epoxy resin and hexahydro-4-methylphthalic anhydride hardener system filled with micro/nano hybrid silica. Various empirical models were fitted to the experimental data and a fitting parameter such as critical filler fractions (${\phi}_{max}$) was estimated. Among the models, the Zhang-Evans model gave the best fit to the viscosity data. For all the silica loadings used, ln (relative viscosity) varied linearly with filler loadings. Using the Zhang-Evans model and the linearity characteristics of the viscosity change, simple methods to predict the relative viscosity below ${\phi}_{max}$ are presented in this work. The predicted viscosity values from the two methods at hybrid silica fractions of $\phi$ = 0.086 and 0.1506 were confirmed for a micro:nano = 1:1 hybrid filler. As a result, the difference between measured and predicted values was less than 11%, indicating that the proposed predicting methods are in good agreement with the experiment.
International Journal of Industrial Entomology and Biomaterials
/
v.33
no.2
/
pp.138-143
/
2016
In the present study, silk fibroin (SF) was dissolved in $CaCl_2/H_2O/EtOH$ solution at $85^{\circ}C$. After the dissolution, the SF solution was cooled down and stored at $4^{\circ}C$ for 28 d. The stability of the solution's viscosity and electrospinnability was observed to examine the stability of SF molecules during storage in $CaCl_2/H_2O/EtOH$ solution. The viscosities of $SF/CaCl_2/H_2O/EtOH$ solution and SF formic acid solution did not change during 28 days' storage of SF in $CaCl_2/H_2O/EtOH$ solution. The electrospinnability of the SF solution, mean diameter of the electrospun SF fiber, and crystallinity index of electrospun SF web did not change, regardless of the length of the storage period. These results imply that SF molecules do not degrade during 28 days' storage in $CaCl_2/H_2O/EtOH$ solution.
Journal of the Korean Graphic Arts Communication Society
/
v.19
no.2
/
pp.49-57
/
2001
This thesis attempts to study ink transition for on the polycarbonate multicalculator plate for automobile. For this study, the change of weight by screen printed ink transition on polycarbonate material by ink viscosity(be diluted ; 0%, 5%, 10%, 20%) was observed. The weight by screen printed ink is depended on amount of added solvent. We have studied change of the weight by the transition of the ink that was screen-printed on polycarbonate which is to be printed according to the viscosity of the ink (diluent: undiluted solution 5%, 10%, 15%, 20%). This shows that ink transition become activated since the amount of ink(or/and the viscosity of ink) is increased.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.